BOILER DE UZ CASNIC PE BAZĂ DE COMBUSTIBIL SOLID STROPUVA MANUAL DE INSTALARE ȘI ÎNTREȚINERE CERTIFICAT NR. SPSC-672

Upload: alexandru-nastase

Post on 07-Nov-2015

36 views

Category:

Documents


3 download

DESCRIPTION

centrale termice stropuva

TRANSCRIPT

  • BOILER DE UZ CASNIC PE BAZ DE

    COMBUSTIBIL SOLID

    STROPUVA

    MANUAL DE INSTALARE I NTREINERE

    CERTIFICAT NR. SPSC-672

  • SUMAR

    1. DIMENSIUNI I CARACTERISTICI ................................................................................................... 4

    1.1 BOILERE CU NCLZIRE PE LEMNE ................................................................................................ 4

    1.2 BOILERE CU NCLZIRE PE BAZ DE CRBUNE ........................................................................ 5

    2. DESCRIEREA STRUCTURII ............................................................................................................... 6

    3. TRANSPORT I DEPOZITARE ........................................................................................................... 7

    4. MONTAJ BOILER ................................................................................................................................. 7

    4.1. CERINE FLACR ............................................................................................................................ 8

    4.2. CERINE CANAL DE CONDUCERE A GAZELOR SPRE CO ...................................................... 8

    4.3. CERINE PENTRU CONECTAREA LA SISTEMUL DE NCLZIRE ............................................ 9

    4.4 FOTOGRAFIA DE ASAMBLARE A BOILERULUI PE BAZ DE COMBUSTIBIL SOLID STROPUVA S40 CU LISTA DE PIESE .................................................................................................... 10

    4.5. DESCRIEREA SCHEMEI DE FUNCIONARE A SISTEMULUI DE NCLZIRE ....................... 12

    4.6. FOTOGRAFIA DE ASAMBLARE A BOILERULUI PE BAZ DE COMBUSTIBIL SOLID STROPUVA S40 ......................................................................................................................................... 12

    4.7. DESCRIEREA SCHEMEI DE FUNCIONARE FR UN BOILER SUPLIMENTAR SAU NCLZIRE PRIN PARDOSEAL ........................................................................................................... 15

    5. ARDEREA I APRINDEREA BOILERULUI .................................................................................... 16

    5.1. CELE MAI ECONOMICE ARDERI DE COMBUSTIBIL N CADRUL BOILERULUI ATUNCI CND ACESTA ESTE COMPLET NCRCAT ...................................................................................... 16

    5.2. AJUSTAREA REGULATORULUI BITERMIC DE TIRAJ .......................................................... 18

    5.3. EVALUAREA FUNCIONRII BOILERULUI ................................................................................ 20

    5.4. CURAREA I NTREINEREA BOILERULUI ........................................................................... 20

    6. CERINE N VEDEREA PREVENIRII ACCIDENTELOR .............................................................. 21

    7. EVALUAREA RISCULUI ................................................................................................................... 23

    7.1. PERICOLE REFERITOARE LA NCLZIRE ................................................................................... 23

    7.2. PERICOLE REFERITOARE LA PRESIUNE ..................................................................................... 23

    7.3. POSIBIL INTOXICARE .................................................................................................................. 23

    7.4. CERINE PENTRU CONECTAREA PIESELOR ELECTRICE ....................................................... 24

  • STIMATE CLIENT,

    Suntem ncntai c ai avut ndredere n noi.

    V prezentm boilerul pentru uz casnic pe baz de combustibil

    solid n deschiderea cruia timpul de ardere pentru o singur

    ncrctur se msoar n zile. Cu o singur arj de lemn, turb i

    brichet de rumegu, boilerul arde timp de 30 de ore iar, cu

    crbune, timpul de ardere este de aproximativ 7 zile.

    Caracteristicile excepionale ale produselor fabricate, care

    prelungesc timpul de ardere al boilerului pe baz de combustibil lichid,

    sunt distribuia de aer din partea superioar i arderea solid

    fracionat din cadrul principiului de candel.

    nainte de instalare i utilizare, v rugm s citii cu atenie acest

    Manual i s urmai strict instruciunile, acest lucru garantnd rezultate

    mai bune n cadrul utilizrii.

    Pstrai acest Manual de Instruciuni ntr-un loc sigur la care s

    putei ajunge uor, respectnd astfel condiiile de garanie.

    Trebuie s pstrai Certificatul de Garanie sau, unde este cazul,

    fia de date tehnice, mpreun cu Manualul de Instruciuni, pe durata

    de via a produsului. Acesta conine informaii tehnice importante cu

    privire la acesta.

    Boilerele termice pe baz de combustibil solid STROPUVA (ncontinuare denumit boiler) sunt

    concepute anume pentru diverse cldiri / camere unde este instalat un sistem de nclzire cu calorifere,

    boiler cu nclzire pe ap n scopuri casnice sau nclzire prin pardoseal, sau toate acestea mpreun.

    Sistemul poate funciona cu tiraj natural i forat, nchis sau deschis.

  • 1. DIMENSIUNI I CARACTERISTICI

    1.1 BOILERE CU NCLZIRE PE LEMNE

    Tabel 1.1. Dimensiuni i caracteristici ale boilerelor cu nclzire pe lemne. Combustibil solid: trunchiuri de lemn pentru foc, deeuri lemnoase, brichete de rumegu. (umezeal recomandat - 30%)*

    MODEL

    PARAMETRI S7 S10 S20 S40 Energie (kW) 7 10 20 40 Zona nclzit (m2) 20-80 50-100 100-250 200-450 Capacitate combustibil (dm3) 150 200 350 500 Cantitatea de lemn pentru foc (kg) 15 25 50 80 Lungime lemn pentru foc (cm) 30-35 30-35 35-45 45-55 Cantitatea de ap din boiler (l) 26 34 45 58 Temperatura apei din boiler (C) 70 70 70 70 Coeficientul de operare util (%) 91,6 Debit de ap cald (m3/h) 0,2 0,25 0,5 1,0 Dimensiunea deschiderii de

    ncrcare (mm) 250x210 250x210 260x220 280x240

    nlime (mm) 1250 1900 1900/2100 1900/2100 Diametru (mm) 450 450 560 680 Mas (kg) 100 185 231 315

    * - Lemnul de foc ce conine mai mult de 30 % umezeal nu va arde complet i dac arde nu va ajunge la temperatura dorit, iar arderea va fi instabil. Durata de ardere a combustibilului ncrcat depinde de calitatea acestuia, de temperatura exterioar i interioar, de calitatea cldirii i de ali factori.

    Tabel 1.2. Informaii pentru instalatori.

    MODEL

    Distana

    ntre

    podea i

    coul de tiraj

    (mm)

    Diametrul

    Coului (mm)

    Distana ntre podea i cuplajul

    inferior

    32 (mm)

    Distana ntre podea i cuplajul superior

    32 (mm)

    Supapa de

    presiune

    (bar)

    Presiunea

    apei nu mai

    mare dect (bar)

    S7 1010 140 27.5 1187.5 1,5 2

    S10 1430 160 12.5 1717.5 1,5 2

    S20 1550 180 23.5 1936.5 1,5 2

    S20 (1.9m) 1410 180 27.5 1727.5 1,5 2

    S40 1550 200 38 1913 1,5 2

    S40 (1.9 m) 1400 200 40 1710 1.5 2

  • 1.2 BOILERE CU NCLZIRE PE BAZ DE CRBUNE

    Table 1.3. Dimensiuni i caracteristici ale boilerelor cu nclzire pe

    crbune. Combustibil solid: trunchiuri de lemn pentru foc, deeuri

    lemnoase, brichete de rumegu i turb, crbune.

    MODEL PARAMETRI S10 U S20 U S40 U Energie (kW) 10 20 40 Zona nclzit (m2) 50-100 100-200 180-400 Capacitate combustibil (dm3) 200 350 500 Cantitatea de crbuni (kg) Cantitatea de lemn pentru foc (kg)

    75 25

    130 50

    220 80

    Lungime lemn pentru foc (cm) 30-35 35-45 45-55 Cantitatea de ap din boiler (l) 34 45 58 Temperatura apei din boiler (C) 85 85 85 Coeficientul de operare util (%) 91,6 Debit de ap cald (m3/h) 0,25 0,5 1,0 Dimensiunea deschiderii de ncrcare (mm)

    250x210 260x220 280x240

    nlime (mm) 1900 1900/2100 1900/2100 Diametru (mm) 450 560 680 Mas (kg) 196 246 333

    * - Lemnul de foc ce conine mai mult de 30 % umezeal nu va arde complet i dac arde nu va ajunge la temperatura dorit, iar arderea va fi instabil. Durata de ardere a combustibilului ncrcat depinde de calitatea

    acestuia, de temperatura exterioar i interioar, de calitatea cldirii i de ali factori.

    Tabel 1.4 . Informaii pentru instalatori.

    MODEL

    Distana

    ntre podea i

    coul de tiraj

    ( mm )

    Diametrul coului

    ( mm )

    Distana

    ntre podea i

    cuplajul inferior

    ( 32 mm )

    Distana

    ntre podea i

    Cuplajul superior

    32 ( mm )

    Supapa de

    presiune ( bar )

    Presiunea apei nu mai mare

    dect

    ( bar )

    S10 U 1550 160 57.5 1737.5 1.5 2

    S20 U 1695 160 57.5 1947.5 1.5 2

    S20 U (1.9m)

    1530 160 57.5 1747.5 1.5 2

    S40 U 1675 180 57.5 1947.5 1.5 2

    S40 U (1 .9 m )

    1520 180 57.5 1747.5 1.5 2

  • 6

    2. DESCRIEREA STRUCTURII

    Boilerul (vezi figura 2.1.) este un

    cilindru de oel acoperit de un cilindru

    de oel de dimensiuni mai mari, care

    izoleaz structura. Regulatorul bitermic

    de tiraj (2) cu reglet de lemn (3) se afl

    n partea din fa a boilerului (pentru

    detalii vezi articolul nr 5.2). Apa cald

    se afl ntre cilindri. O structur are

    deschideri (8) pentru ncrcarea cu

    combustibil solid (10), pentru scoaterea

    cenuii (11) i pentru tirajul coului de

    fum (5). De asemenea, exist

    deschideri (14-15) pentru alimentarea

    cu ap, termometru (16) i supap de

    siguran pentru presiune (17).

    Compartimentul de nclzire a aerului

    (4) pentru mbuntirea calitii

    combustibilului i a transmisiei de

    cldur este montat n partea superioar

    a compartimentului de ardere. Boilerul

    poate fi configurat cu bare de grtar i

    supap de comutare (6) pentru arderea

    cu turb sau crbune.

    Exist o distan ntre

    compartimentul de nclzire i

    pereii boilerului prin care trece

    fumul, astfel nct cldura este mai

    bine transmis. O conduct

    telescopic de alimentare cu aer (7)

    este montat ntr-un compartiment la

    captul cruia este fixat distribuitorul

    de aer (9). Fig. 2.1.Diagrama boilerului

  • 7

    n partea superioar a unui compartiment se afl o deschidere pentru injecie cu aer i supapa de

    reglare (1). La cerere, boilerul este configurat cu o baz din beton cu o band izolatoare (18). Cablul de

    ridicare cu inel (12) al mecanismului de alimentare cu aer se afl n partea dreapt a boilerului n faa uii

    (crlig de fixare) (13).

    Scopul distribuitorului de aer este acela de a distribui corect aerul n zonele de generare de

    dedesubt i de lnga distribuitorul de aer, n zona de combustie de lng i de deasupra

    distribuitorului. Distribuitorul de aer se nclin pe partea trunchiurilor de lemn care nu se ncing la

    temperatur mare.

    Nu se permite deplasarea distribuitorului pe durata arderii: dup deplasarea distribuitorului de aer n

    sus i n jos, se rotete i se adncete n locul de ardere, funcionarea boilerului fiind neeconomic, piesele

    sale uzndu-se mai mult.

    3. TRANSPORT I DEPOZITARE

    Boilerele pot fi transportate nelegate doar n poziie orizontal. Dac nu plou, se permite transportul

    deschis, n alte cazuri trebuie transportat acoperit. Atunci cnd se transport n poziie vertical, trebuie

    luate msuri suplimentare de protecie, astfel nct boilerul s nu cad i s nu se zgrie. Boilerele pot fi

    depozitate n zone uscate, fr ageni chimici activi.

    4. MONTAJ BOILER

    Boilerul este montat n locaii care corespund cerinelor stabilite pentru locaiile unor case cu

    boilere. Locaiile n care trebuie montat un boiler trebuie s aib cel puin 215 cm nlime, podea de beton

    (cel puin n locul n care va fi montat boilerul). Locaiile trebuie s fie impermeabile i protejate de

    camerele de locuit nclzite, trebuie s aib un canal de ventilare pe vertical i o fereastr sau o

    deschidere pe peretele exterior astfel nct aerul din afar s intre n boiler i n canalul de ventilare. Cu

    ajutorul unei oglinzi, examinai interiorul canalului pentru conducerea gazelor spre co prin deschiderea

    acestuia. Canalul pentru conducerea gazelor spre co trebuie s fie curat. Nu trebuie s existe piese rmase

    sau cuiburi de psri sau deschideri neacoperite care s duc ctre golul din tavan sau ctre puurile

    adiacente. Se verific canalul pentru conducerea gazelor spre co pentru a nu avea deschideri sau sprturi

    pe exterior prin care poate intra aer contaminat care s rceasc canalul i s i reduc curentul de aer.

    Sprturile, deschiderile i locul n care boilerul este conectat la canal trebuie sigiliate. Dac exist

    deschideri interioare n canal care duc la tavan sau n puuri/mine adiacente i nu exist posibilitatea s le

    reparai, trebuie montat un oval sau o inserie cilindric din oel inoxidabil. (Inseriile dreptunghiulare nu

    sunt potrivite din cauza sprturilor formate n locurile de conectare din cauza schimbrilor de

    temperatur). Boilerul este ridicat drept pe o suprafa de beton; orice sprtur ntre pardoseal i boiler va

  • 8

    fi sigilat cu silicon rezistent la cldur sau cu o soluie din ciment cu nisip sau alte materiale. Boilerul

    poate fi ridicat pe o plac de beton special pentru montaj, cu un cablu de izolare.

    Cteodat, pe durata transportului, unele pri ale boilerului se deformeaz, drept pentru care atunci

    cnd sunt montate pe canalul de conducere a gazelor spre co i dup nchiderea tuturor uilor i

    deschiderea canalului, verificai funcionarea supapei superioare, potrivirea pe suprafaa deschiderii prizei

    de aer i a uilor de izolare, folosind flacra unei lumnri sau un chibrit.

    4.1. CERINE FLACR

    Boilerul este ridicat pe o baz neinflamabil. Conectarea metalic a boilerului lng co trebuie s se

    efectueze printr-un metal nu mai subire de 1,5 mm acoperit cu materiale izolante. Starea canalului de

    conducere a gazelor spre co trebuie verificat odat pe lun (prin examinarea sa pe durata zile prin

    deschiderea folosit pentru curare, cu ajutorul unei oglinzi), n caz de nevoie curai-l deoarece cenua

    i catranul depozitate pe deschidere se pot aprinde din cauza scnteilor, cauznd pericol de incendiu,

    supranclzirea sau avarierea pieselor de racord. Cnd folosii un canal de conducere (din oel inoxidabil

    sau ceramic), studiai manualul utilizatorului i ndeplinii cerinele, n special curarea periodic. Dup

    ce canalul de conducere a gazelor spre co este curat, trebuie curat i canalul dintre boiler i coul de

    fum.

    4.2. CERINE CANAL DE CONDUCERE A GAZELOR SPRE CO

    Limea transversal a deschiderii canalului de conducere a gazelor spre co poate fi cu 10% mai

    mic dect este menionat n cerinele tehnice minime, dar nu mai mare. Boilerul necesit un canal de

    conducere a gazelor spre co; niciun alt dispozitiv nu poate fi conectat la acesta. Astfel nct condensul

    format n canalul de conducere a gazelor spre co s nu intre n boiler, trebuie s existe un canal dinspre

    boiler nspre coul de fum, orizontal i nu mai lung de 1.5 m sau mai scurt de 0.20 m, bine sigilat i izolat

    cu un material de izolare n locurile de conectare. Canalul de conducere a gazelor spre co i coul vor fi

    periodic curate, respectnd cerinele de mai sus.

    Se recomand:

    S montai n co un racord din oel inoxidabil; un racord curat i bine montat protejeaz coul

    mpotriva efectului de condens sau a umezelii;

    Racordul nu trebuie s diminueze semnificativ seciunea transversal a deschiderii coului; piesele

    racordului trebuie strnse (cu nituri din oel inoxidabil);

    Colectorul de cenu trebuie montat jos, la 15-20 cm dedesubtul conexiunea canalului la coul de

    fum; apoi acesta poate fi curat cu uurin;

  • 9

    Golul coului ntre racord i pereii coului, cel puin n afara coului, trebui umplut cu materiale

    izolatoare. n partea de sus, fisurile trebuie sigilate ermetic i cositorite (din deschiderea coului);

    n seciunea de rcile, coul trebuie sigilat cu materiale de izolare.

    4.3. CERINE PENTRU CONECTAREA LA SISTEMUL DE NCLZIRE

    Boilerul trebuie montat de tehnicieni calificai, care cunosc toate cerinele i care garanteaz

    lucrarea, consultnd de fiecare dat manualul de operare a boilerului. Produsul nostru nu este similar

    structurilor anterioare. Prin urmare ceea ce se potrivete altor boilere, nu se potrivete acestuia.

    De exemplu, pentru boilerele n care arderea se desfoar dedesubtul unui focar, se recomand un

    circuit invers al debitului nclzit. Nu se potrivete n cazul boilerului nostru.

    Dac elemente actualizate ale sistemelor de nclzire din diagramele de conectare ale boilerelor sunt

    divers i variat folosite, recomandndu-se diagrame diverse i complicate, noi recomandm mai multe

    diagrame simple, ieftine i justificate.

    Pe durata procedurii de montaj a elementelor suplimentare, v rugm s citii i s respectai cu

    atenie cerinele productorului:

    1. Conform recomandrilor productorilor de supape termice, setai supapele pre-debit conform

    instruciunilor modelului sistemului de nclzire (dac nu este cazul, atunci la 1.5 sau 1).

    2. Nu depii debitul de cldur prin temperatura podelei cu ajutorul elementelor de nclzire

    automat prin podea (recomandrile productorilor: 28 35C).

    3. Dup montarea supapelor mixte cu trei sau patru trepte i a unei pompe circulare astfel nct

    elementele boilerului i nclzirea s nu fie legate n paralel, montai un inel larg al sistemului de nclzire

    al casei. De preferaat pe o conduct de presiune reversibil.

    4. Dup cum se ntmpl n mod normal, nu legai n paralel elemente ale boilerului de o surs de

    nclzire a apei conectat la boiler (este nevoie de o supap de echilibrare la conectarea dispozitivului de nclzire

    a apei n paralel).

    5. Meninei temperatura optim pentru funcionarea boilerului (70 85C).

    6. Respectai recomandrile productorului de racorduri pentru canalul de conducere a gazului spre co.

    7. Nu se permite montarea unei supape de nchidere pe canal de conducere a gazului spre co. Pentru

    a reduce umezeala, folosii supapele de admisie produse de noi sau de ali productori.

    8. Atenie, n camera boilerului ventiliia trebuie s fie suficient.

    9. Oridecteori montai boilerul nostru pe baz de combustibil solid, verificai certificatul tehnic (acolo este posibil s gsii informaii utile).

  • 10

    4.4 FOTOGRAFIA DE ASAMBLARE A BOILERULUI PE BAZ DE COMBUSTIBIL SOLID STROPUVA S40 CU LISTA DE PIESE

    F de la/spre nclzirea prin pardoseal, B - de la/spre boiler, K2 - de la/spre alt boiler pe baz de combustibil solid.

    Nodurile pentru boilere S7, S10, S20 se fac ntre piese D20. Nodul pentru boiler S40 se face din piese D25. ATENIE: supapa de siguran presiune de 1,5 bar se implic n deschidere (17) (fig. 2.1.). n loc de trident (5), folosii un cot D25 SME (10).

    Nr. Detalii evrie Unitate

    1 * - Supap de siguran

    presiune 1

    2 Ventil de aerisire automat 1

    3 Supap de echilibrare D15 1

    4 Tranziie D25 15 3

    5 Trident D25 11

    6 Trident D25 15 2

    7 Manon D25 1

    8 Niplu D25 18

    9 Conector reversibil D25

    SME 2

    10 Cotitur D25 SME 3

    11 Tranziie D32 25 2

    12 Supap sferic D25 SME 3

    13 Cotitur D25 2

    14 Supap termostat DT25 1

    15 Set subjugare pomp de

    circulare 7

    16 Pomp de circulare 1

    17 Disc cu bol de alam D25 2

    18

    Supape de evacuare i complementare

    D15

    2

    19

    Supap cu trei ci pentru

    distribuia debitului

    D25

    1

    Fig . 4 . 1 . Nod evrie. R - de la/spre radiator,

  • 11

    Fig. 4.2. Schema sistemului de nclzire cu un boiler suplimentar i cu nclzire prin pardoseal.

  • 12

    4.5. DESCRIEREA SCHEMEI DE FUNCIONARE A SISTEMULUI DE NCLZIRE

    Pompa (P) pompeaz apa n afara elemenilor de nclzire i o mpinge prin boiler prin elementele de

    nclzire (vezi figura 4.2). Prin robinetul de compensare (bk 1), apa cald se scurge n cel mai apropiat

    radiator, care poate funciona autonom pentru a proteja boilerul de supranclzire (radiator fr o supap

    termic) n cazul n care se oprete alimentarea cu energie electric.

    De acum nainte, apa cald curge prin boilerul pe baz de combustibil solid 2k (dac aceast opiune

    este disponibil), care pornete dac boilerul 1k nu mai arde sau se oprete cnd boilerul 1k furnizeaz ap

    cald mulumit automatizrii interne. Dac boilerul 2k este disponibil, nchiztorul (3) se oprete, dac

    nu, acesta este pornit.

    De acum nainte, apa cald curge prin dispozitivul de nclzire a apei (B) i nchiztor (3). Dac

    intrarea are un diametru insuficient, nchiztorul (3) este oprit deoarece apa curge prin nclzitor, se

    nclzete mai mult ap. Dup ce a nclzit apa menajer, apa de termoficare curge prin sistemul radiator

    i prin supapa termostat (T2-20-50) dac este nevoie i intr n sistemul de nclzire prin pardoseal.

    Senzorul supapei termostat deschide supapa dac apa este mai rece dect este indicat (35C) i o nchide

    dac apa este mai cald.

    Mulumit pompei (P), apa circul abundent prin evile de nclzire prin pardoseal (F) i de

    asemenea curge n boiler prin supapa de distribuie a debitului (T-3-20-50), care, datorit senzorului,

    direcioneaz o parte a debitului rece n sistemul radiator deoarece debitul de retur este mai cald dect se

    indic (40), meninnd o cldur stabil n locuin chiar dac nu este disponibil nicio supap termic,

    protejnd podeaua de supranclzire. (bk2) i (bk3) sunt supape de nchidere (nu robinei cu nchidere

    sferic rotund) sau supape cu determinare mbuntit a debitului, prin care debitul pompei este

    distribuit astfel nct s fie suficient pentru nclzirea pardoselei i corespunztor pentru pomp. Debitul

    general depinde de pompa de circulare i poate fi controlat prin comutarea poziiei vitezei pompei.

    Dac sistemul nu are un sistem de nclzire prin pardoseal T2, nu este necesar s instalai

    termostatul pe durata verii. Ca s creeze un boiler solid pe baz de combustibil solid, boilerul, radiatorul i

    tubulatura de pardoseal deschid i nchid T2 prin deurubarea capacului sau prin nlturarea

    termostatului.

    O pomp de circulare alimentat cu 25 60 W este suficient pentru un boiler de 10kW, 40 - 80 W

    pentru un boiler de 20kW i 50 100 W pentru un boiler de 40 kW. (bk1) un robinet de echilibrare a

    unui radiator cu auto debit de siguran, prin care debitul este determinat s fac eava de retur de 40C

    mai rece dect eava de intrare. (7) conectorii reversibili prin eliberarea lor, nodul poate fi comutat

    ctre o alt parte a boilerului.

  • 13

    Nodurile pentru boilere s7, s10, s20 se fac ntre piese D20. Nodul pentru boilerul s40 se face din piesele D25. ATENIE: supapa de siguran presiune de 1,5 bar se implic n deschidere (17) (fig. 2.1.). n loc de trident (5), folosii un cot D25 SME (10)

    Nr. Detalii evrie Unitate

    1 * - Supap de siguran

    presiune 1

    2 Ventil de aerisire automat 1

    3 Supap de echilibrare D15 1

    4 Tranziie D25 15 2

    5 Trident D25 7

    6 Trident D25 15 3

    7 Manon D25 1

    8 Niplu D25 11

    9 Conector reversibil D25

    SME 2

    10 Cotitur D25 SME 3

    11 Tranziie D32 25 2

    12 Supap sferic D25 SME 3

    13 Cotitur D25 2

    14

    15 Set subjugare pomp de

    circulare 7

    16 Pomp de circulare 1

    17 Disc cu bol de alam D25 2

    18

    Supape de evacuare i complementare

    D15

    2

    19

    Supap cu trei ci pentru

    distribuia debitului

    D25

    1

    4.6 FOTOGRAFIA DE ASAMBLARE A BOILERULUI PE BAZ DE COMBUSTIBIL

    SOLID STROPUVA S40 CU LISTA DE PIESE

    Fig 4.3. Nodul de instalare R ctre/ de la Radiatoar, B ctre/ de la boiler

  • 14

    Fig. 4.4. Schema sistemului de nclzire cu un boiler suplimentar i fr nclzire prin pardoseal.

  • 15

    4.7. DESCRIEREA SCHEMEI DE FUNCIONARE FR UN BOILER SUPLIMENTAR SAU

    NCLZIRE PRIN PARDOSEAL

    Pompa (P) pompez apa n afara elemenilor de nclzire i o mpinge prin boiler prin elementele de

    nclzire (vezi figura 4.4). Prin robinetul de compensare (bk 1), apa cald se scurge n cel mai apropiat

    radiator, care poate funciona autonom pentru a proteja boilerul de supranclzire (radiator fr o supap

    termic) n cazul n care se oprete alimentarea cu energie electric.

    De acum nainte, apa cald curge prin boilerul pe baz de combustibil solid 2k (dac aceast opiune

    este disponibil), care pornete dac boilerul 1k nu mai arde sau se oprete cnd boilerul 1k furnizeaz ap

    cald mulumit automatizrii interne. Dac boilerul 2k este disponibil, nchiztorul (3) se oprete, dac

    nu, acesta este pornit.

    De acum nainte, apa cald curge prin dispozitivul de nclzire a apei (B) i nchiztor (3). Dac

    intrarea are un diametru insuficient, nchiztorul (3) este oprit deoarece apa curge prin nclzitor, se

    nclzete mai mult ap.

    Dup ce a nclzit apa menajer, apa de termoficare curge prin sistemul radiator.

    Mulumit pompei (P), apa circul abundent prin supapa de distribuie a debitului (T-320-50), care,

    datorit senzorului, direcioneaz o parte a debitului rece n sistemul radiator deoarece debitul de retur este

    mai cald dect se indic (40), partea mai rece a debitului referindu-se la sistemul radiator, meninnd o

    cldur stabil la interior, chiar i n absena supapelor termice.

    O pomp de circulare alimentat cu 25 60 W este suficient pentru un boiler de 10kW, 40 - 80

    W pentru un boiler de 20kW i 50 100 W pentru un boiler de 40 kW.

    (bk1) un robinet de echilibrare a unui radiator cu auto debit de siguran, prin care debitul este

    determinat s fac eava de retur de 40C mai rece dect eava de intrare.

    (7) conectorii reversibili prin eliberarea lor, nodul poate fi comutat ctre o alt parte a

    boilerului.

  • 16

    5. ARDEREA I APRINDEREA BOILERULUI

    5.1. CELE MAI ECONOMICE ARDERI DE COMBUSTIBIL N CADRUL BOILERULUI ATUNCI CND ACESTA ESTE COMPLET NCRCAT Supapa de comutare (6) atunci cnd lemnul de foc trebuie cobort (vezi figura 5.1.A), cnd

    crbunele arde trebuie ridicat (fig. 5.1. B). Cnd combustibilul se ncarc, distribuitorul de aer (9) trebuie

    ridicat; prin urmare montai un inel la captul cablului (12) de deasupra uilor focarului, tragei n jos i

    asigurai cu un crlig (13)

    Folosii distribuitorul de aer (9)

    (vezi figura 5.2. A.) i apoi lemnul de

    foc. ncrcai lemnul pe orizontal:

    cele mai lungi pe mijloc i cel emai

    scurte pe lateral. Este util s umplei

    spaiile dintre lemne cu rumegu sau

    deeuri fine de lemn. Folosii un

    distribuitor de aer (figura 5.2. B.)

    pentru arderea crbunelui mic, un

    boiler pe crbune funcioneaz la 50

    70% din capacitate, prin urmare

    folosii crbune mic n zilele mai

    calde. Cnd ncrcai turb, ncrcai

    mai nti brichete mai mari i apoi

    buci mici de brichete de turb. B

    distribuitor tubular de aer pentru brichete

    de crbune sau turb.

    Fig. 5.1. Supapa de comutare dinuntrul boilerului.

    Fig. 5.2. A - Distribuitor aer pentru f lemn deeuri de lemn, rumegu

  • 17

    Dup ncrcarea lemnului, facei imediat focul, astfel nct ncrctura s nu se aprind de la

    cenua fierbinte rmas!

    Cnd ncrcai crbune, folosii grilajul (vezi fig. 5.3.), deschidei prin tragerea n sus a supapei de

    aer pentru crbune i turb pentru a cura cenua i crusta depuse.

    Fig. 5.3. Grilaj pentru aprinderea cu crbune i turb.

    ncrcai bulgri de crbune, un crbune mai mare ct un mouse de computer tiat n buci mici. Nu

    ncrcai i alt combustibil;

    doar deasupra ncrcturii de

    crbune putei aduga n jur

    de 2 kg de achii mici de

    lemn.

    Prin nvrtirea

    urubului de reglare (vezi

    figura 5.4. A) se deschide o

    supap de control a aerului de

    3-5 cm. Aprindei partea de

    deasupra a ncrcturii (fig.

    5.4. B), nchidei uor ua,

    lsnd o deschiztur de 1-3

    cm. Cnd combustibilul se

    aprinde, nchidei ua i

    scoatei din crlig un inel cu

    ajutorul unui cablu de

    ridicare. Fluidul lichid folosit

    pentru aprinderea emineelor

    sau a cuptoarelor poate fi

  • 18

    folosit pentru aprinderea boilerului, dar nu poate fi folosit drept combustibil.

    Deschidei o fereastr sau o surs de ieire spre exterior n afara peretelui boilerului pe durata arderii

    astfel nct boilerul s primeasc aer de afar. Cnd arde crbunele, nu aprindei boilerul. Cnd ardei

    lemn, pe durata arderii boilerul poate fi ncrcat cu lemn de foc i deeu de lemn: nainte de acest lucru,

    ridicai distribuitorul de aer i deschidei ua. Dup ncrcarea suplimentar, calitatea combustibilului i

    economia slbesc o perioad, prin urmare v recomandm s o facei astfel nct s extindei durata de

    ardere pn la urmtoarea ncrcare sau ardere. Dac folosii lemn umed sau alt tip de rumegu pe post de

    combustibil sau deeuri lemnoase, se recomand folosirea unui colector de aer (fig. 5.4. C) i

    mbuntirea arderii prin adugarea de rumegu mpreun cu lemnul. Cnd ardei crbune sau turb, este

    nevoie de un colector prin injecie. ntotdeauna ncrctura unui alt tip de combustibil este aprins prin

    uile superioare (8).

    ATENIE!

    1. Colectorul prin injecie de aer este comutat doar dup ce uile sunt nchise i focul este fcut.

    Senzorul canalului de conducere a gazelor spre co (cu un capilar subire 200-300C) trebuie

    montat pe un canal i pe o surs de ap (70C) ntre corp i materialul de etanare.

    2. Pe durata utilizrii boilerului, este periculos s deschidei larg uile flacra v poate

    arde faa. Prin urmare, la nceput nu v uitai nuntrul boilerului i stai departe, deschidei

    uile focarului doar 2-3 cm i abia dup 20-30 sec. deschidei uile i ncrcai lemnul pentru

    foc dar nu mai mult de dou arje (20-30cm), nchidei ua i tragei n jos distribuitorul de

    aer.

    3. Nu este permis trecerea aerului prin uile inferioare prin care se face accesul pentru

    curarea cenuei.

    5.2. AJUSTAREA REGULATORULUI BITERMIC DE TIRAJ

    Metoda de funcionare a acestui regulator se bazeaz pe faptul c atunci cnd corpul boilerului se

    ncinge se dilat, corpul se strnge lng o supap de control (1) printr-o manet (4), iar cnd se rcete,

    se contract i se deschide.

    Cnd boilerul este adus n camera boilerului i este conectat la evria sistemului de nclzire,

    verificai dac piesele de reglare a tirajului nu sunt deformate: bara de susinere (3) montat pe boiler,

    presa prii sale metalice (5) trebuie s fie pe partea neizolat a manetei supapei (4) i urubul de setare a

    temperaturii (2) pivotul pe sgeata manetei (4). Sgeata i partea neizolat se afl una lng cealalt la o

    distan de 3.5 mm. Verificai dac supapa nchide complet conductele de aer, dac urubul su este slbit,

    nu-l nurubai. Cu ajutorul unei urubelnie setai supapa la o distan de 3-5 cm de deschiderea pe

    injecie, i abia apoi aprindei boilerul.

  • 19

    Cnd metalul i apa se nclzesc, cilindrul boilerului se alungete i coboar supapa. Cnd indicatorul de

    temperatur arat nu mai puin de 80 C, deschidei supapa cu ajutorul unei urubelnie de reglaj (2); iar n

    cazul n care se indic mai mult nchidei uor pn ce temperatura atinge 80 C. Dac dorii s setai

    ulterior o temperatur mai joas, rotii inelul ctre o cifr mai mic. Un inel nu poate fi rotit n spatele unei

    cifre mai mari (dac este rotit mai mult, sunt posibile supranclzirea i fierberea apei).

    Fig. 5.5 . Regulatorul bitermal de umezeal.

  • 20

    5.3. EVALUAREA FUNCIONRII BOILERULUI

    Dac dup aprindere boilerul funcioneaz bine, i mai apoi capacitatea sa i tirajul descresc,

    nseamn c este insuficient strns canalul de conducere a gazelor spre co: verificai dac uile prin care

    se asigur curenia canalului de conducere a gazelor spre co sunt nchise sau dac exist alte probleme

    de strngere nlturai-le.

    Dac dup ardere se aude un zgomot ritmic nuntrul boilerului i uneori iese fum, nseamn c

    tirajul canalului de conducere a gazelor spre co este prea puternic boilerul nu are capacitate i

    funcionarea sa nu este economic. n acest caz, aerul trebuie introdus n canalul de conducere a gazelor

    spre co prin deschiderile speciale. Rotii maneta n sensul acelor de ceasormic astfel nct zgomotul

    boilerului s dispar.

    n cazul n care combustibilul arde bine dar indicatorul de temperatur se ridic uor i condensul se

    scurge prin canalul de conducere a gazelor spre co, nseamn c debitul de ap cald este depit: pornii

    o pomp circular n cea mai de jos poziie i reducei debitul prin banda de echilibrare a boilerului din

    cadrul elemenilor de nclzire pn ce condensul nu mai picur de pe canal iar temperatura boilerului

    ajunge la 70 80C.

    5.4. CURAREA I NTREINEREA BOILERULUI

    Cnd sunt arse lemne, cenua acestora trebuie ndeprtat lunar din boiler. Cnd sunt ari crbuni

    sau turb, cenua trebuie nlturat lunar, nainte de fiecare ardere. Este normal ca pereii boilerului s fie

    acoperii de un strat de gudron, dar dac tirajul este slab, dac aerul trece prin partea inferioar a uilor,

    dac pe durata arderii boilerul este amorsat iar distribuitorul de aer este deplasat, dac debitul de ap cald

    este prea intens, nseamn c este posibil ca prea mult gudron s se fi depus, iar boilerul s fie mbcsit.

    Prin urmare, toate aceste defecte trebuie eliminate.

    Cnd tirajul este redus, destuparea dintre compartimentul de nclzire a aerului (2) i pereii interiori

    ai boilerului trebuie verificat. Curarea se poate face cu o perie flexibil prin deschiderea superioar

    pentru degajarea fumului de deasupra uii focarului. Este mai convenabil s se curee printr-un orificiu de

    evacuare a fumului (dup dezasamblarea conexiunii cu canalul de conducere a gazelor spre co) sau printr-

    o deschidere special din conexiune.

    Boilerul nu se va mbcsi dac sistemul de nclzire este corect montat; canalul de conducere a

    gazelor spre co este n stare bun i este folosit conform recomandrilor din manual. Distribuitorul

    de aer este cobort, poate aduna cenu veche, de aceea trebuie verificat i curat.

    Dac o sprtur dintre plcile inferioare este redus sau dispare, trebuie reparat dup dezasamblarea

    distribuitorului. Cablul mecanismului de ridicare trebuie gresat astfel nct s nu se uzeze, iar distribuitorul

  • 21

    va fi ridicat mai uor. Recomandm gresarea uii prin nchiderea ambelor crlige. Uneori trebuie s se

    verifice dac nchiderea uilor i locul dintre podelele de ciment i boiler se afl n stare bun. nlturai

    problemele nchiderii folosind materialele rezistente la cldur menionate mai sus. Pentru a uile s fie

    nchise ermetic, materialele de etanare trebuie nlocuite.

    6. CERINE N VEDEREA PREVENIRII ACCIDENTELOR

    Boilerul este o zon cu potenial crescut de pericol. Dac v comportai iresponsabil, este posibil s v rnii, s v intoxicai, s provocai un incendiu, s defectai boilerul sau sistemul de nclzire.

    CERINE DE SIGURAN I INTERZICERI CONSECINELE NERESPECTRII

    INTERZICERILOR I A MSURILOR

    Nu fierbei apa din boiler.

    Dac apa fierbe, boilerul se va supranclzi i va ceda.

    Dac boilerul va fierbe din motive necunoscute, stai

    cu faa departe de ui, deschidei-le i turnai ap n

    focar.

    Nu aprindei boilerul fr ap. Nu permitei ca

    presiunea din sistem s fie mai mare de 1.5 bar. Nu

    turnai ap foarte rece n sistemul de nclzire i n

    boiler.

    Defectarea boilerului i a altor piese din

    sistemul de nclzire.

    Aerul de afar trebuie s intre n camera

    boilerului.

    Este posibil s v intoxicai lng boiler chiar dac

    acesta nu funcioneaz deschidei o fereastr n

    camera boilerului sau introducei aer n camer prin

    alte mijloace.

    Nu introducei aer prin ua de jos i nu ncrcai lemne prin partea de jos

    Condensul se va scurge; se va consuma i mai mult

    lemn. Apa va fierben boiler, crbunele va cdea.

    Nu depozitai combustibil n boiler (dup

    ncrcarea lemnului, acesta trebuie aprins)

    Lemnul de foc va lua foc din cauza cenuii fierbini i

    va fumega producnd condens i gudron.

    Nu deplasai distribuitorul de aer pe durata arderii.

    Cnd cobori distribuitorul de aer, se va plia, iar dac

    este introdus mai adnc n combustibil se va uza mai

    repede de la cldur.

  • 22

    CELE MAI FRECVENTE GREELI DE

    MONTAJ CONSECINE/ NLTURARE

    Este montat conform schielor altor productori de boilere pentru c exist

    posibilitatea de retur a unei cantiti mari de ap cald, aducnd dup sine un efect

    negativ precum condensul.

    Debitul intens rcete suficient compartimentele de ardere i pereii plini de fum, astfel nct umezeala se va prelinge pe perei dei uscat pe durata nclzirii, dar poate lipi cenua pe perei, ducnd la mbcsirea

    periodic a boilerului i a coului de fum. Setai debitul recomandat umezeala se va

    acumula sub focarul de combustie crpturile de fum vor fi mereu curate.

    Pompa circular mpreun cu boilerul este montat pe vechiul sistem unde

    elementele nu sunt reglate

    Datorit unui debit intens de ap rece, se descarc mult condens, un mirox puternic intoxicant intr n camera boilerului, iar

    acesta funcioneaz la o capacitate neeconomic ce i poate diminua capacitatea. Montai un robinet de

    echilibrare n faa boilerului sau nuntrul acestuia.

    GREELI COMUNE DE UTILIZARE

    Se arde cnd tirajul canalului de

    conducere a gazelor spre co este prea

    puternic

    Se aude un puls n boiler. Uneori aerul din supape sare. Boilerul funcionez foarte

    neeconomic, condensul se scurge,

    capacitatea scade. Rotii supapa de reglare a manetei n sus i fixai-o astfel nct tirajul s deschid uor supapa de injecie. Dac ai achiziionat boilerul fr un canal de

    conducere a fumului spre co, este suficient s tiai o seciune n form de U n grinda orizontal i s ndreptai gradat limba

    format pn ce funcionarea boilerului se stabilizeaz.

    Cablul de distribuie a aerului nu este gresat.

    Distribuitorul de aer este rigicat cu greutate,

    cablul se uzeaz. Trebuie gresat cu un

    lubrefiant WD 40 sau vaselin.

    Ambalaje de plastic sau de carton sunt arse

    n boiler

    Dac arderea este ntrziat de bucile de carton, atunci plasticul sau ambalajele

    sunt periculoase deoarece genereaz gaze, nu ard unifrom, excesul acumulat poate

    genera explozie, sprgnd conectorii canalului de conducere a fumului spre

    co.

    Se menine o temperatur de 60C a boilerului

    Boilerul i canalul de conducere a fumului

    spre co sunt mbcsite din cauza

    condensului.

  • 23

    7. EVALUAREA RISCULUI

    7.1. PERICOLE REFERITOARE LA NCLZIRE

    Este posibil s v alegei cu arsuri din cauza atingerii elementelor boilerului. Suprafaa boilerului

    care poate fi nclzit pn la o temperatur de 40 C i alte pri conform caracteristicilor tehnice, este

    izolat dar mai exist pri precum mnerele uilor i uile care sunt fierbini i periculoase. Astfel de

    locuri sunt marcate printr-o inscripie internaional. evile cu ap fierbinte ale sistemului de nclzire

    trebuie izolate, dup testul hidraulic. Supapa de presiune a conductei de evacuare trebuie s duc la

    canalizare. Trebuie lsat o deschiztur de 10 cm pentru monitorizare i izolare.

    7.2. PERICOLE REFERITOARE LA PRESIUNE

    Creterea presiunii este posibil: cnd tensiunea cade i pompa circular se oprete, boilerul nu este

    reumplut cu ap rece din sistem iar temperatura atinge nivelul periculos cnd regulatorul de tiraj este

    activat prin nchiderea unei supape la setarea modului de temperatur, nepermind aerului s intre i

    stingnd boilerul. Temperatura poate atinge nivelul critic de 100 C din inerie dar apa nu va fierbe n

    boiler deoarece mulumit unei metode de ardere. Dac supapa de nchidere este deformat sau din cauza

    altor nclcri ale regulilor de funcionare (de exemplu ua compartimentului de cenu este deschis), apa

    din boiler poate ncepe s fiarb. Totui supapa de protecie a presiunii montat pe conducta superioar a

    debitului de alimentare elibereaz vapori i nu depete presiunea, permind boilerului s se umple cu

    ap dintr-o conduct a sistemului, pentru a se rci.

    n caz utilizare necorespunztoare: de exemplu, dei aerul este introdus printr-o u inferioar n

    boiler, datorit arderii intensive din boiler, capacitatea sa este depit de mai multe ori, astfel c boilerul

    poate fierbe apa, iar dac este supranclzit, se poate fisura din cauza presiunii normale.

    Boilerul se poate fisura i din cauza unei presiuni prea mari, dac supapa de protecie a presiunii este

    montat ntr-un loc necorespunztor sau este mbcsit. Dup cum o dovedesc calculele i practica,

    boilerul nu va exploda n afar ci va crpa pe dinuntru, prin urmare nu exist pericol pentru sntatea sau

    viaa oamenilor.

    7.3. POSIBIL INTOXICARE

    Cnd canalul de conducere a gazelor spre co este mbcsit sau cnd este curat de cenu, n

    camera boilerului se poate acumula monoxid de carbon, prin urmare este nevoie de o ventilaie natural,

    iar pentru funcionarea sa aceast ventilaie afluent este necesar prin deschiderea unei mici ferestre pe

    peretele lateral al camerei boilerului. Dac nu exist o ventilaie afluent, boilerul nu a funciona. Prin

    urmare nu uitai s instalai un sistem de ventilare interioar a boilerului n peretele acestuia sau n camer,

    direct de afar. Ua camerei boilerului trebuie strns bine astfel nct unitatea sanitar de urgen saau

  • 24

    ventilaia buctriei sunt pornite, funcionarea boilerului nu va fi afectat, iar praful sau monoxidul de

    carbon nu vor trece din camera boilerului n cas.

    7.4. CERINE PENTRU CONECTAREA PIESELOR ELECTRICE

    Pompele circulare sunt montate pe sistem i folosesc curent electric. Acestea trebuie conectate de o

    persoan care are calificarea de tehnician i permis pentru o astfel de lucrare. Lucrrile de montaj trebuie

    efectuate conform proiectului (lund n considerare capacitatea general de intrare). Curentul electric

    poate afecta omul! Conexiunile electrice trebuie izolate, trebuie s aib mpmntare, iar instalaia trebuie

    fcut conform standardelor valabile n ara respectiv.

    JSC "STROPUVA ir KO", Cod de identificare fiscal: 300149972, Adres: Vaduvos str., 2A,

    LT-02304 Vilnius, telefon: +370 5 255 1763, fax. +370 5 232 2525, mob. +370 656 16223, E-

    mail: [email protected] or [email protected], www.stropuva.lt

    CONFIGURARE

    1. Supapa de alimentare cu aer (montat n partea superioar a boilerului);

    2. Stand de lemn pentru controlerul termic (montat cu ajutorul unei benzi lng ua prin care se realizeaz ncrcarea);

    3. Supap de protecie a presiunii, 1.5 bar;

    4. Termometru;

    5. Co de fum cu alimentare regulat cu aer;

    6. Colector injecie cu aer (pentru boilerele adaptate s ard crbunele);

    7. Distribuitor tubular aer (pentru boilerele adaptate s ard crbunele).

    Recomandm achiziionarea unui generator de rezerv n cazul n care survine o pan de curent.

    ATENIE: Eliberai regulatorul de tiraj din prinderile sale; tragei-l deasupra barei de pe laterala boilerului, indicatorul superior al regulatorului de tiraj montat n deschiztura injeciei cu aer.

    TERMENI DE GARANIE A PRODUSULUI

    Productorul garanteaz c produsul corespunde cerinelor documentaiei tehnice.

    Productorul ofer o garanie de doi ani boilerului.

    Productorul ofer o garanie de cinci ani schimbtorului de cldur al boilerului.

    Productorul se oblig s rezolve defectele datorate unei avarii a productorului.

    Utilizatorul, prin achiziionarea boilerului se oblig:

    1. S monteze boilerul i s-l utilizeze conform recomandrilor din acest manual.

    2. S studieze & s nvee acest manual de utilizare! 3. S pstreze acest document de garanie i notiele n siguran!

    Productorul nu i asum nicio obligaie pentru funcionarea boilerului i consecinele ulterioare i nu va oferi garanie n urmtoarele cazuri:

    1. Alimentarea cu energie electric nu ntrunete cerinele casei,

    2. Boilerul este montat n neconcordan cu recomandrile acestei fie de date,

    3. Boilerul funcioneaz n neconformitate cu recomandrile acestui Manual,

    4. Garania produsului nu este valabil fr un document de garanie.

  • 25

    CERTIFICAT DE GARANIE

    Boilerul termic are o garanie de doi ani.

    Schimbtorul de cldur are o garanie de cinci ani.

    Boiler ______________________________________________________________________________

    Produs numrul ____________________________________________________________________

    Data nceperii perioadei de garanie _______________________________________________

    Semntura vnztorului, tampila, data

  • 26

  • 27

    CERTIFICAT

    Certificat de examinare de tip EC

    (certificat de conformitate)

    Conform Directivei Echipamentelor sub Presiune 97/23/EC

    Certificat nr. 0662/0288/05

    Numele i adresa productorului:

    UAB STROPUVA Vaduvos g. 2A

    LT-02304 Vilinius

    Prin prezentul se atest faptul c modelul ansamblurilor de generare a apei calde conform articolului 3, paragraf 2.3 de mai jos, ntrunete cerinele Directivei Echipamentelor sub Presiune 97/23/EC, Anexa I, seciunile 2.10, 2.11, 3.4, 5(a) i 5 (d).

    Descrierea echipamentului sub presiune: Tipuri nr S7, S10, S20 i S40

    Categorie: Articolul 3, paragraful 3

    Raport de examinare nr LT08/056/05

    Schia nr: VR 00.00.SB

    Cod de fabricaie: EN 303-5, EN 12828

    Gera, 18.05.2005 tampila TUV Thuringen e.V Organism notificat

    Semntur indescifrabil TUV CERT Organism de certificare pentru echipamentele sub presiune ale TUV

    Thuringen e.V

    Organism notificat 0090, 97/23/EC

    Melchendorfer Str. 64, D-990096 Erfurt