manual stropuva
DESCRIPTION
centrale termice stropuvaTRANSCRIPT
-
BOILER DE UZ CASNIC PE BAZ DE
COMBUSTIBIL SOLID
STROPUVA
MANUAL DE INSTALARE I NTREINERE
CERTIFICAT NR. SPSC-672
-
SUMAR
1. DIMENSIUNI I CARACTERISTICI ................................................................................................... 4
1.1 BOILERE CU NCLZIRE PE LEMNE ................................................................................................ 4
1.2 BOILERE CU NCLZIRE PE BAZ DE CRBUNE ........................................................................ 5
2. DESCRIEREA STRUCTURII ............................................................................................................... 6
3. TRANSPORT I DEPOZITARE ........................................................................................................... 7
4. MONTAJ BOILER ................................................................................................................................. 7
4.1. CERINE FLACR ............................................................................................................................ 8
4.2. CERINE CANAL DE CONDUCERE A GAZELOR SPRE CO ...................................................... 8
4.3. CERINE PENTRU CONECTAREA LA SISTEMUL DE NCLZIRE ............................................ 9
4.4 FOTOGRAFIA DE ASAMBLARE A BOILERULUI PE BAZ DE COMBUSTIBIL SOLID STROPUVA S40 CU LISTA DE PIESE .................................................................................................... 10
4.5. DESCRIEREA SCHEMEI DE FUNCIONARE A SISTEMULUI DE NCLZIRE ....................... 12
4.6. FOTOGRAFIA DE ASAMBLARE A BOILERULUI PE BAZ DE COMBUSTIBIL SOLID STROPUVA S40 ......................................................................................................................................... 12
4.7. DESCRIEREA SCHEMEI DE FUNCIONARE FR UN BOILER SUPLIMENTAR SAU NCLZIRE PRIN PARDOSEAL ........................................................................................................... 15
5. ARDEREA I APRINDEREA BOILERULUI .................................................................................... 16
5.1. CELE MAI ECONOMICE ARDERI DE COMBUSTIBIL N CADRUL BOILERULUI ATUNCI CND ACESTA ESTE COMPLET NCRCAT ...................................................................................... 16
5.2. AJUSTAREA REGULATORULUI BITERMIC DE TIRAJ .......................................................... 18
5.3. EVALUAREA FUNCIONRII BOILERULUI ................................................................................ 20
5.4. CURAREA I NTREINEREA BOILERULUI ........................................................................... 20
6. CERINE N VEDEREA PREVENIRII ACCIDENTELOR .............................................................. 21
7. EVALUAREA RISCULUI ................................................................................................................... 23
7.1. PERICOLE REFERITOARE LA NCLZIRE ................................................................................... 23
7.2. PERICOLE REFERITOARE LA PRESIUNE ..................................................................................... 23
7.3. POSIBIL INTOXICARE .................................................................................................................. 23
7.4. CERINE PENTRU CONECTAREA PIESELOR ELECTRICE ....................................................... 24
-
STIMATE CLIENT,
Suntem ncntai c ai avut ndredere n noi.
V prezentm boilerul pentru uz casnic pe baz de combustibil
solid n deschiderea cruia timpul de ardere pentru o singur
ncrctur se msoar n zile. Cu o singur arj de lemn, turb i
brichet de rumegu, boilerul arde timp de 30 de ore iar, cu
crbune, timpul de ardere este de aproximativ 7 zile.
Caracteristicile excepionale ale produselor fabricate, care
prelungesc timpul de ardere al boilerului pe baz de combustibil lichid,
sunt distribuia de aer din partea superioar i arderea solid
fracionat din cadrul principiului de candel.
nainte de instalare i utilizare, v rugm s citii cu atenie acest
Manual i s urmai strict instruciunile, acest lucru garantnd rezultate
mai bune n cadrul utilizrii.
Pstrai acest Manual de Instruciuni ntr-un loc sigur la care s
putei ajunge uor, respectnd astfel condiiile de garanie.
Trebuie s pstrai Certificatul de Garanie sau, unde este cazul,
fia de date tehnice, mpreun cu Manualul de Instruciuni, pe durata
de via a produsului. Acesta conine informaii tehnice importante cu
privire la acesta.
Boilerele termice pe baz de combustibil solid STROPUVA (ncontinuare denumit boiler) sunt
concepute anume pentru diverse cldiri / camere unde este instalat un sistem de nclzire cu calorifere,
boiler cu nclzire pe ap n scopuri casnice sau nclzire prin pardoseal, sau toate acestea mpreun.
Sistemul poate funciona cu tiraj natural i forat, nchis sau deschis.
-
1. DIMENSIUNI I CARACTERISTICI
1.1 BOILERE CU NCLZIRE PE LEMNE
Tabel 1.1. Dimensiuni i caracteristici ale boilerelor cu nclzire pe lemne. Combustibil solid: trunchiuri de lemn pentru foc, deeuri lemnoase, brichete de rumegu. (umezeal recomandat - 30%)*
MODEL
PARAMETRI S7 S10 S20 S40 Energie (kW) 7 10 20 40 Zona nclzit (m2) 20-80 50-100 100-250 200-450 Capacitate combustibil (dm3) 150 200 350 500 Cantitatea de lemn pentru foc (kg) 15 25 50 80 Lungime lemn pentru foc (cm) 30-35 30-35 35-45 45-55 Cantitatea de ap din boiler (l) 26 34 45 58 Temperatura apei din boiler (C) 70 70 70 70 Coeficientul de operare util (%) 91,6 Debit de ap cald (m3/h) 0,2 0,25 0,5 1,0 Dimensiunea deschiderii de
ncrcare (mm) 250x210 250x210 260x220 280x240
nlime (mm) 1250 1900 1900/2100 1900/2100 Diametru (mm) 450 450 560 680 Mas (kg) 100 185 231 315
* - Lemnul de foc ce conine mai mult de 30 % umezeal nu va arde complet i dac arde nu va ajunge la temperatura dorit, iar arderea va fi instabil. Durata de ardere a combustibilului ncrcat depinde de calitatea acestuia, de temperatura exterioar i interioar, de calitatea cldirii i de ali factori.
Tabel 1.2. Informaii pentru instalatori.
MODEL
Distana
ntre
podea i
coul de tiraj
(mm)
Diametrul
Coului (mm)
Distana ntre podea i cuplajul
inferior
32 (mm)
Distana ntre podea i cuplajul superior
32 (mm)
Supapa de
presiune
(bar)
Presiunea
apei nu mai
mare dect (bar)
S7 1010 140 27.5 1187.5 1,5 2
S10 1430 160 12.5 1717.5 1,5 2
S20 1550 180 23.5 1936.5 1,5 2
S20 (1.9m) 1410 180 27.5 1727.5 1,5 2
S40 1550 200 38 1913 1,5 2
S40 (1.9 m) 1400 200 40 1710 1.5 2
-
1.2 BOILERE CU NCLZIRE PE BAZ DE CRBUNE
Table 1.3. Dimensiuni i caracteristici ale boilerelor cu nclzire pe
crbune. Combustibil solid: trunchiuri de lemn pentru foc, deeuri
lemnoase, brichete de rumegu i turb, crbune.
MODEL PARAMETRI S10 U S20 U S40 U Energie (kW) 10 20 40 Zona nclzit (m2) 50-100 100-200 180-400 Capacitate combustibil (dm3) 200 350 500 Cantitatea de crbuni (kg) Cantitatea de lemn pentru foc (kg)
75 25
130 50
220 80
Lungime lemn pentru foc (cm) 30-35 35-45 45-55 Cantitatea de ap din boiler (l) 34 45 58 Temperatura apei din boiler (C) 85 85 85 Coeficientul de operare util (%) 91,6 Debit de ap cald (m3/h) 0,25 0,5 1,0 Dimensiunea deschiderii de ncrcare (mm)
250x210 260x220 280x240
nlime (mm) 1900 1900/2100 1900/2100 Diametru (mm) 450 560 680 Mas (kg) 196 246 333
* - Lemnul de foc ce conine mai mult de 30 % umezeal nu va arde complet i dac arde nu va ajunge la temperatura dorit, iar arderea va fi instabil. Durata de ardere a combustibilului ncrcat depinde de calitatea
acestuia, de temperatura exterioar i interioar, de calitatea cldirii i de ali factori.
Tabel 1.4 . Informaii pentru instalatori.
MODEL
Distana
ntre podea i
coul de tiraj
( mm )
Diametrul coului
( mm )
Distana
ntre podea i
cuplajul inferior
( 32 mm )
Distana
ntre podea i
Cuplajul superior
32 ( mm )
Supapa de
presiune ( bar )
Presiunea apei nu mai mare
dect
( bar )
S10 U 1550 160 57.5 1737.5 1.5 2
S20 U 1695 160 57.5 1947.5 1.5 2
S20 U (1.9m)
1530 160 57.5 1747.5 1.5 2
S40 U 1675 180 57.5 1947.5 1.5 2
S40 U (1 .9 m )
1520 180 57.5 1747.5 1.5 2
-
6
2. DESCRIEREA STRUCTURII
Boilerul (vezi figura 2.1.) este un
cilindru de oel acoperit de un cilindru
de oel de dimensiuni mai mari, care
izoleaz structura. Regulatorul bitermic
de tiraj (2) cu reglet de lemn (3) se afl
n partea din fa a boilerului (pentru
detalii vezi articolul nr 5.2). Apa cald
se afl ntre cilindri. O structur are
deschideri (8) pentru ncrcarea cu
combustibil solid (10), pentru scoaterea
cenuii (11) i pentru tirajul coului de
fum (5). De asemenea, exist
deschideri (14-15) pentru alimentarea
cu ap, termometru (16) i supap de
siguran pentru presiune (17).
Compartimentul de nclzire a aerului
(4) pentru mbuntirea calitii
combustibilului i a transmisiei de
cldur este montat n partea superioar
a compartimentului de ardere. Boilerul
poate fi configurat cu bare de grtar i
supap de comutare (6) pentru arderea
cu turb sau crbune.
Exist o distan ntre
compartimentul de nclzire i
pereii boilerului prin care trece
fumul, astfel nct cldura este mai
bine transmis. O conduct
telescopic de alimentare cu aer (7)
este montat ntr-un compartiment la
captul cruia este fixat distribuitorul
de aer (9). Fig. 2.1.Diagrama boilerului
-
7
n partea superioar a unui compartiment se afl o deschidere pentru injecie cu aer i supapa de
reglare (1). La cerere, boilerul este configurat cu o baz din beton cu o band izolatoare (18). Cablul de
ridicare cu inel (12) al mecanismului de alimentare cu aer se afl n partea dreapt a boilerului n faa uii
(crlig de fixare) (13).
Scopul distribuitorului de aer este acela de a distribui corect aerul n zonele de generare de
dedesubt i de lnga distribuitorul de aer, n zona de combustie de lng i de deasupra
distribuitorului. Distribuitorul de aer se nclin pe partea trunchiurilor de lemn care nu se ncing la
temperatur mare.
Nu se permite deplasarea distribuitorului pe durata arderii: dup deplasarea distribuitorului de aer n
sus i n jos, se rotete i se adncete n locul de ardere, funcionarea boilerului fiind neeconomic, piesele
sale uzndu-se mai mult.
3. TRANSPORT I DEPOZITARE
Boilerele pot fi transportate nelegate doar n poziie orizontal. Dac nu plou, se permite transportul
deschis, n alte cazuri trebuie transportat acoperit. Atunci cnd se transport n poziie vertical, trebuie
luate msuri suplimentare de protecie, astfel nct boilerul s nu cad i s nu se zgrie. Boilerele pot fi
depozitate n zone uscate, fr ageni chimici activi.
4. MONTAJ BOILER
Boilerul este montat n locaii care corespund cerinelor stabilite pentru locaiile unor case cu
boilere. Locaiile n care trebuie montat un boiler trebuie s aib cel puin 215 cm nlime, podea de beton
(cel puin n locul n care va fi montat boilerul). Locaiile trebuie s fie impermeabile i protejate de
camerele de locuit nclzite, trebuie s aib un canal de ventilare pe vertical i o fereastr sau o
deschidere pe peretele exterior astfel nct aerul din afar s intre n boiler i n canalul de ventilare. Cu
ajutorul unei oglinzi, examinai interiorul canalului pentru conducerea gazelor spre co prin deschiderea
acestuia. Canalul pentru conducerea gazelor spre co trebuie s fie curat. Nu trebuie s existe piese rmase
sau cuiburi de psri sau deschideri neacoperite care s duc ctre golul din tavan sau ctre puurile
adiacente. Se verific canalul pentru conducerea gazelor spre co pentru a nu avea deschideri sau sprturi
pe exterior prin care poate intra aer contaminat care s rceasc canalul i s i reduc curentul de aer.
Sprturile, deschiderile i locul n care boilerul este conectat la canal trebuie sigiliate. Dac exist
deschideri interioare n canal care duc la tavan sau n puuri/mine adiacente i nu exist posibilitatea s le
reparai, trebuie montat un oval sau o inserie cilindric din oel inoxidabil. (Inseriile dreptunghiulare nu
sunt potrivite din cauza sprturilor formate n locurile de conectare din cauza schimbrilor de
temperatur). Boilerul este ridicat drept pe o suprafa de beton; orice sprtur ntre pardoseal i boiler va
-
8
fi sigilat cu silicon rezistent la cldur sau cu o soluie din ciment cu nisip sau alte materiale. Boilerul
poate fi ridicat pe o plac de beton special pentru montaj, cu un cablu de izolare.
Cteodat, pe durata transportului, unele pri ale boilerului se deformeaz, drept pentru care atunci
cnd sunt montate pe canalul de conducere a gazelor spre co i dup nchiderea tuturor uilor i
deschiderea canalului, verificai funcionarea supapei superioare, potrivirea pe suprafaa deschiderii prizei
de aer i a uilor de izolare, folosind flacra unei lumnri sau un chibrit.
4.1. CERINE FLACR
Boilerul este ridicat pe o baz neinflamabil. Conectarea metalic a boilerului lng co trebuie s se
efectueze printr-un metal nu mai subire de 1,5 mm acoperit cu materiale izolante. Starea canalului de
conducere a gazelor spre co trebuie verificat odat pe lun (prin examinarea sa pe durata zile prin
deschiderea folosit pentru curare, cu ajutorul unei oglinzi), n caz de nevoie curai-l deoarece cenua
i catranul depozitate pe deschidere se pot aprinde din cauza scnteilor, cauznd pericol de incendiu,
supranclzirea sau avarierea pieselor de racord. Cnd folosii un canal de conducere (din oel inoxidabil
sau ceramic), studiai manualul utilizatorului i ndeplinii cerinele, n special curarea periodic. Dup
ce canalul de conducere a gazelor spre co este curat, trebuie curat i canalul dintre boiler i coul de
fum.
4.2. CERINE CANAL DE CONDUCERE A GAZELOR SPRE CO
Limea transversal a deschiderii canalului de conducere a gazelor spre co poate fi cu 10% mai
mic dect este menionat n cerinele tehnice minime, dar nu mai mare. Boilerul necesit un canal de
conducere a gazelor spre co; niciun alt dispozitiv nu poate fi conectat la acesta. Astfel nct condensul
format n canalul de conducere a gazelor spre co s nu intre n boiler, trebuie s existe un canal dinspre
boiler nspre coul de fum, orizontal i nu mai lung de 1.5 m sau mai scurt de 0.20 m, bine sigilat i izolat
cu un material de izolare n locurile de conectare. Canalul de conducere a gazelor spre co i coul vor fi
periodic curate, respectnd cerinele de mai sus.
Se recomand:
S montai n co un racord din oel inoxidabil; un racord curat i bine montat protejeaz coul
mpotriva efectului de condens sau a umezelii;
Racordul nu trebuie s diminueze semnificativ seciunea transversal a deschiderii coului; piesele
racordului trebuie strnse (cu nituri din oel inoxidabil);
Colectorul de cenu trebuie montat jos, la 15-20 cm dedesubtul conexiunea canalului la coul de
fum; apoi acesta poate fi curat cu uurin;
-
9
Golul coului ntre racord i pereii coului, cel puin n afara coului, trebui umplut cu materiale
izolatoare. n partea de sus, fisurile trebuie sigilate ermetic i cositorite (din deschiderea coului);
n seciunea de rcile, coul trebuie sigilat cu materiale de izolare.
4.3. CERINE PENTRU CONECTAREA LA SISTEMUL DE NCLZIRE
Boilerul trebuie montat de tehnicieni calificai, care cunosc toate cerinele i care garanteaz
lucrarea, consultnd de fiecare dat manualul de operare a boilerului. Produsul nostru nu este similar
structurilor anterioare. Prin urmare ceea ce se potrivete altor boilere, nu se potrivete acestuia.
De exemplu, pentru boilerele n care arderea se desfoar dedesubtul unui focar, se recomand un
circuit invers al debitului nclzit. Nu se potrivete n cazul boilerului nostru.
Dac elemente actualizate ale sistemelor de nclzire din diagramele de conectare ale boilerelor sunt
divers i variat folosite, recomandndu-se diagrame diverse i complicate, noi recomandm mai multe
diagrame simple, ieftine i justificate.
Pe durata procedurii de montaj a elementelor suplimentare, v rugm s citii i s respectai cu
atenie cerinele productorului:
1. Conform recomandrilor productorilor de supape termice, setai supapele pre-debit conform
instruciunilor modelului sistemului de nclzire (dac nu este cazul, atunci la 1.5 sau 1).
2. Nu depii debitul de cldur prin temperatura podelei cu ajutorul elementelor de nclzire
automat prin podea (recomandrile productorilor: 28 35C).
3. Dup montarea supapelor mixte cu trei sau patru trepte i a unei pompe circulare astfel nct
elementele boilerului i nclzirea s nu fie legate n paralel, montai un inel larg al sistemului de nclzire
al casei. De preferaat pe o conduct de presiune reversibil.
4. Dup cum se ntmpl n mod normal, nu legai n paralel elemente ale boilerului de o surs de
nclzire a apei conectat la boiler (este nevoie de o supap de echilibrare la conectarea dispozitivului de nclzire
a apei n paralel).
5. Meninei temperatura optim pentru funcionarea boilerului (70 85C).
6. Respectai recomandrile productorului de racorduri pentru canalul de conducere a gazului spre co.
7. Nu se permite montarea unei supape de nchidere pe canal de conducere a gazului spre co. Pentru
a reduce umezeala, folosii supapele de admisie produse de noi sau de ali productori.
8. Atenie, n camera boilerului ventiliia trebuie s fie suficient.
9. Oridecteori montai boilerul nostru pe baz de combustibil solid, verificai certificatul tehnic (acolo este posibil s gsii informaii utile).
-
10
4.4 FOTOGRAFIA DE ASAMBLARE A BOILERULUI PE BAZ DE COMBUSTIBIL SOLID STROPUVA S40 CU LISTA DE PIESE
F de la/spre nclzirea prin pardoseal, B - de la/spre boiler, K2 - de la/spre alt boiler pe baz de combustibil solid.
Nodurile pentru boilere S7, S10, S20 se fac ntre piese D20. Nodul pentru boiler S40 se face din piese D25. ATENIE: supapa de siguran presiune de 1,5 bar se implic n deschidere (17) (fig. 2.1.). n loc de trident (5), folosii un cot D25 SME (10).
Nr. Detalii evrie Unitate
1 * - Supap de siguran
presiune 1
2 Ventil de aerisire automat 1
3 Supap de echilibrare D15 1
4 Tranziie D25 15 3
5 Trident D25 11
6 Trident D25 15 2
7 Manon D25 1
8 Niplu D25 18
9 Conector reversibil D25
SME 2
10 Cotitur D25 SME 3
11 Tranziie D32 25 2
12 Supap sferic D25 SME 3
13 Cotitur D25 2
14 Supap termostat DT25 1
15 Set subjugare pomp de
circulare 7
16 Pomp de circulare 1
17 Disc cu bol de alam D25 2
18
Supape de evacuare i complementare
D15
2
19
Supap cu trei ci pentru
distribuia debitului
D25
1
Fig . 4 . 1 . Nod evrie. R - de la/spre radiator,
-
11
Fig. 4.2. Schema sistemului de nclzire cu un boiler suplimentar i cu nclzire prin pardoseal.
-
12
4.5. DESCRIEREA SCHEMEI DE FUNCIONARE A SISTEMULUI DE NCLZIRE
Pompa (P) pompeaz apa n afara elemenilor de nclzire i o mpinge prin boiler prin elementele de
nclzire (vezi figura 4.2). Prin robinetul de compensare (bk 1), apa cald se scurge n cel mai apropiat
radiator, care poate funciona autonom pentru a proteja boilerul de supranclzire (radiator fr o supap
termic) n cazul n care se oprete alimentarea cu energie electric.
De acum nainte, apa cald curge prin boilerul pe baz de combustibil solid 2k (dac aceast opiune
este disponibil), care pornete dac boilerul 1k nu mai arde sau se oprete cnd boilerul 1k furnizeaz ap
cald mulumit automatizrii interne. Dac boilerul 2k este disponibil, nchiztorul (3) se oprete, dac
nu, acesta este pornit.
De acum nainte, apa cald curge prin dispozitivul de nclzire a apei (B) i nchiztor (3). Dac
intrarea are un diametru insuficient, nchiztorul (3) este oprit deoarece apa curge prin nclzitor, se
nclzete mai mult ap. Dup ce a nclzit apa menajer, apa de termoficare curge prin sistemul radiator
i prin supapa termostat (T2-20-50) dac este nevoie i intr n sistemul de nclzire prin pardoseal.
Senzorul supapei termostat deschide supapa dac apa este mai rece dect este indicat (35C) i o nchide
dac apa este mai cald.
Mulumit pompei (P), apa circul abundent prin evile de nclzire prin pardoseal (F) i de
asemenea curge n boiler prin supapa de distribuie a debitului (T-3-20-50), care, datorit senzorului,
direcioneaz o parte a debitului rece n sistemul radiator deoarece debitul de retur este mai cald dect se
indic (40), meninnd o cldur stabil n locuin chiar dac nu este disponibil nicio supap termic,
protejnd podeaua de supranclzire. (bk2) i (bk3) sunt supape de nchidere (nu robinei cu nchidere
sferic rotund) sau supape cu determinare mbuntit a debitului, prin care debitul pompei este
distribuit astfel nct s fie suficient pentru nclzirea pardoselei i corespunztor pentru pomp. Debitul
general depinde de pompa de circulare i poate fi controlat prin comutarea poziiei vitezei pompei.
Dac sistemul nu are un sistem de nclzire prin pardoseal T2, nu este necesar s instalai
termostatul pe durata verii. Ca s creeze un boiler solid pe baz de combustibil solid, boilerul, radiatorul i
tubulatura de pardoseal deschid i nchid T2 prin deurubarea capacului sau prin nlturarea
termostatului.
O pomp de circulare alimentat cu 25 60 W este suficient pentru un boiler de 10kW, 40 - 80 W
pentru un boiler de 20kW i 50 100 W pentru un boiler de 40 kW. (bk1) un robinet de echilibrare a
unui radiator cu auto debit de siguran, prin care debitul este determinat s fac eava de retur de 40C
mai rece dect eava de intrare. (7) conectorii reversibili prin eliberarea lor, nodul poate fi comutat
ctre o alt parte a boilerului.
-
13
Nodurile pentru boilere s7, s10, s20 se fac ntre piese D20. Nodul pentru boilerul s40 se face din piesele D25. ATENIE: supapa de siguran presiune de 1,5 bar se implic n deschidere (17) (fig. 2.1.). n loc de trident (5), folosii un cot D25 SME (10)
Nr. Detalii evrie Unitate
1 * - Supap de siguran
presiune 1
2 Ventil de aerisire automat 1
3 Supap de echilibrare D15 1
4 Tranziie D25 15 2
5 Trident D25 7
6 Trident D25 15 3
7 Manon D25 1
8 Niplu D25 11
9 Conector reversibil D25
SME 2
10 Cotitur D25 SME 3
11 Tranziie D32 25 2
12 Supap sferic D25 SME 3
13 Cotitur D25 2
14
15 Set subjugare pomp de
circulare 7
16 Pomp de circulare 1
17 Disc cu bol de alam D25 2
18
Supape de evacuare i complementare
D15
2
19
Supap cu trei ci pentru
distribuia debitului
D25
1
4.6 FOTOGRAFIA DE ASAMBLARE A BOILERULUI PE BAZ DE COMBUSTIBIL
SOLID STROPUVA S40 CU LISTA DE PIESE
Fig 4.3. Nodul de instalare R ctre/ de la Radiatoar, B ctre/ de la boiler
-
14
Fig. 4.4. Schema sistemului de nclzire cu un boiler suplimentar i fr nclzire prin pardoseal.
-
15
4.7. DESCRIEREA SCHEMEI DE FUNCIONARE FR UN BOILER SUPLIMENTAR SAU
NCLZIRE PRIN PARDOSEAL
Pompa (P) pompez apa n afara elemenilor de nclzire i o mpinge prin boiler prin elementele de
nclzire (vezi figura 4.4). Prin robinetul de compensare (bk 1), apa cald se scurge n cel mai apropiat
radiator, care poate funciona autonom pentru a proteja boilerul de supranclzire (radiator fr o supap
termic) n cazul n care se oprete alimentarea cu energie electric.
De acum nainte, apa cald curge prin boilerul pe baz de combustibil solid 2k (dac aceast opiune
este disponibil), care pornete dac boilerul 1k nu mai arde sau se oprete cnd boilerul 1k furnizeaz ap
cald mulumit automatizrii interne. Dac boilerul 2k este disponibil, nchiztorul (3) se oprete, dac
nu, acesta este pornit.
De acum nainte, apa cald curge prin dispozitivul de nclzire a apei (B) i nchiztor (3). Dac
intrarea are un diametru insuficient, nchiztorul (3) este oprit deoarece apa curge prin nclzitor, se
nclzete mai mult ap.
Dup ce a nclzit apa menajer, apa de termoficare curge prin sistemul radiator.
Mulumit pompei (P), apa circul abundent prin supapa de distribuie a debitului (T-320-50), care,
datorit senzorului, direcioneaz o parte a debitului rece n sistemul radiator deoarece debitul de retur este
mai cald dect se indic (40), partea mai rece a debitului referindu-se la sistemul radiator, meninnd o
cldur stabil la interior, chiar i n absena supapelor termice.
O pomp de circulare alimentat cu 25 60 W este suficient pentru un boiler de 10kW, 40 - 80
W pentru un boiler de 20kW i 50 100 W pentru un boiler de 40 kW.
(bk1) un robinet de echilibrare a unui radiator cu auto debit de siguran, prin care debitul este
determinat s fac eava de retur de 40C mai rece dect eava de intrare.
(7) conectorii reversibili prin eliberarea lor, nodul poate fi comutat ctre o alt parte a
boilerului.
-
16
5. ARDEREA I APRINDEREA BOILERULUI
5.1. CELE MAI ECONOMICE ARDERI DE COMBUSTIBIL N CADRUL BOILERULUI ATUNCI CND ACESTA ESTE COMPLET NCRCAT Supapa de comutare (6) atunci cnd lemnul de foc trebuie cobort (vezi figura 5.1.A), cnd
crbunele arde trebuie ridicat (fig. 5.1. B). Cnd combustibilul se ncarc, distribuitorul de aer (9) trebuie
ridicat; prin urmare montai un inel la captul cablului (12) de deasupra uilor focarului, tragei n jos i
asigurai cu un crlig (13)
Folosii distribuitorul de aer (9)
(vezi figura 5.2. A.) i apoi lemnul de
foc. ncrcai lemnul pe orizontal:
cele mai lungi pe mijloc i cel emai
scurte pe lateral. Este util s umplei
spaiile dintre lemne cu rumegu sau
deeuri fine de lemn. Folosii un
distribuitor de aer (figura 5.2. B.)
pentru arderea crbunelui mic, un
boiler pe crbune funcioneaz la 50
70% din capacitate, prin urmare
folosii crbune mic n zilele mai
calde. Cnd ncrcai turb, ncrcai
mai nti brichete mai mari i apoi
buci mici de brichete de turb. B
distribuitor tubular de aer pentru brichete
de crbune sau turb.
Fig. 5.1. Supapa de comutare dinuntrul boilerului.
Fig. 5.2. A - Distribuitor aer pentru f lemn deeuri de lemn, rumegu
-
17
Dup ncrcarea lemnului, facei imediat focul, astfel nct ncrctura s nu se aprind de la
cenua fierbinte rmas!
Cnd ncrcai crbune, folosii grilajul (vezi fig. 5.3.), deschidei prin tragerea n sus a supapei de
aer pentru crbune i turb pentru a cura cenua i crusta depuse.
Fig. 5.3. Grilaj pentru aprinderea cu crbune i turb.
ncrcai bulgri de crbune, un crbune mai mare ct un mouse de computer tiat n buci mici. Nu
ncrcai i alt combustibil;
doar deasupra ncrcturii de
crbune putei aduga n jur
de 2 kg de achii mici de
lemn.
Prin nvrtirea
urubului de reglare (vezi
figura 5.4. A) se deschide o
supap de control a aerului de
3-5 cm. Aprindei partea de
deasupra a ncrcturii (fig.
5.4. B), nchidei uor ua,
lsnd o deschiztur de 1-3
cm. Cnd combustibilul se
aprinde, nchidei ua i
scoatei din crlig un inel cu
ajutorul unui cablu de
ridicare. Fluidul lichid folosit
pentru aprinderea emineelor
sau a cuptoarelor poate fi
-
18
folosit pentru aprinderea boilerului, dar nu poate fi folosit drept combustibil.
Deschidei o fereastr sau o surs de ieire spre exterior n afara peretelui boilerului pe durata arderii
astfel nct boilerul s primeasc aer de afar. Cnd arde crbunele, nu aprindei boilerul. Cnd ardei
lemn, pe durata arderii boilerul poate fi ncrcat cu lemn de foc i deeu de lemn: nainte de acest lucru,
ridicai distribuitorul de aer i deschidei ua. Dup ncrcarea suplimentar, calitatea combustibilului i
economia slbesc o perioad, prin urmare v recomandm s o facei astfel nct s extindei durata de
ardere pn la urmtoarea ncrcare sau ardere. Dac folosii lemn umed sau alt tip de rumegu pe post de
combustibil sau deeuri lemnoase, se recomand folosirea unui colector de aer (fig. 5.4. C) i
mbuntirea arderii prin adugarea de rumegu mpreun cu lemnul. Cnd ardei crbune sau turb, este
nevoie de un colector prin injecie. ntotdeauna ncrctura unui alt tip de combustibil este aprins prin
uile superioare (8).
ATENIE!
1. Colectorul prin injecie de aer este comutat doar dup ce uile sunt nchise i focul este fcut.
Senzorul canalului de conducere a gazelor spre co (cu un capilar subire 200-300C) trebuie
montat pe un canal i pe o surs de ap (70C) ntre corp i materialul de etanare.
2. Pe durata utilizrii boilerului, este periculos s deschidei larg uile flacra v poate
arde faa. Prin urmare, la nceput nu v uitai nuntrul boilerului i stai departe, deschidei
uile focarului doar 2-3 cm i abia dup 20-30 sec. deschidei uile i ncrcai lemnul pentru
foc dar nu mai mult de dou arje (20-30cm), nchidei ua i tragei n jos distribuitorul de
aer.
3. Nu este permis trecerea aerului prin uile inferioare prin care se face accesul pentru
curarea cenuei.
5.2. AJUSTAREA REGULATORULUI BITERMIC DE TIRAJ
Metoda de funcionare a acestui regulator se bazeaz pe faptul c atunci cnd corpul boilerului se
ncinge se dilat, corpul se strnge lng o supap de control (1) printr-o manet (4), iar cnd se rcete,
se contract i se deschide.
Cnd boilerul este adus n camera boilerului i este conectat la evria sistemului de nclzire,
verificai dac piesele de reglare a tirajului nu sunt deformate: bara de susinere (3) montat pe boiler,
presa prii sale metalice (5) trebuie s fie pe partea neizolat a manetei supapei (4) i urubul de setare a
temperaturii (2) pivotul pe sgeata manetei (4). Sgeata i partea neizolat se afl una lng cealalt la o
distan de 3.5 mm. Verificai dac supapa nchide complet conductele de aer, dac urubul su este slbit,
nu-l nurubai. Cu ajutorul unei urubelnie setai supapa la o distan de 3-5 cm de deschiderea pe
injecie, i abia apoi aprindei boilerul.
-
19
Cnd metalul i apa se nclzesc, cilindrul boilerului se alungete i coboar supapa. Cnd indicatorul de
temperatur arat nu mai puin de 80 C, deschidei supapa cu ajutorul unei urubelnie de reglaj (2); iar n
cazul n care se indic mai mult nchidei uor pn ce temperatura atinge 80 C. Dac dorii s setai
ulterior o temperatur mai joas, rotii inelul ctre o cifr mai mic. Un inel nu poate fi rotit n spatele unei
cifre mai mari (dac este rotit mai mult, sunt posibile supranclzirea i fierberea apei).
Fig. 5.5 . Regulatorul bitermal de umezeal.
-
20
5.3. EVALUAREA FUNCIONRII BOILERULUI
Dac dup aprindere boilerul funcioneaz bine, i mai apoi capacitatea sa i tirajul descresc,
nseamn c este insuficient strns canalul de conducere a gazelor spre co: verificai dac uile prin care
se asigur curenia canalului de conducere a gazelor spre co sunt nchise sau dac exist alte probleme
de strngere nlturai-le.
Dac dup ardere se aude un zgomot ritmic nuntrul boilerului i uneori iese fum, nseamn c
tirajul canalului de conducere a gazelor spre co este prea puternic boilerul nu are capacitate i
funcionarea sa nu este economic. n acest caz, aerul trebuie introdus n canalul de conducere a gazelor
spre co prin deschiderile speciale. Rotii maneta n sensul acelor de ceasormic astfel nct zgomotul
boilerului s dispar.
n cazul n care combustibilul arde bine dar indicatorul de temperatur se ridic uor i condensul se
scurge prin canalul de conducere a gazelor spre co, nseamn c debitul de ap cald este depit: pornii
o pomp circular n cea mai de jos poziie i reducei debitul prin banda de echilibrare a boilerului din
cadrul elemenilor de nclzire pn ce condensul nu mai picur de pe canal iar temperatura boilerului
ajunge la 70 80C.
5.4. CURAREA I NTREINEREA BOILERULUI
Cnd sunt arse lemne, cenua acestora trebuie ndeprtat lunar din boiler. Cnd sunt ari crbuni
sau turb, cenua trebuie nlturat lunar, nainte de fiecare ardere. Este normal ca pereii boilerului s fie
acoperii de un strat de gudron, dar dac tirajul este slab, dac aerul trece prin partea inferioar a uilor,
dac pe durata arderii boilerul este amorsat iar distribuitorul de aer este deplasat, dac debitul de ap cald
este prea intens, nseamn c este posibil ca prea mult gudron s se fi depus, iar boilerul s fie mbcsit.
Prin urmare, toate aceste defecte trebuie eliminate.
Cnd tirajul este redus, destuparea dintre compartimentul de nclzire a aerului (2) i pereii interiori
ai boilerului trebuie verificat. Curarea se poate face cu o perie flexibil prin deschiderea superioar
pentru degajarea fumului de deasupra uii focarului. Este mai convenabil s se curee printr-un orificiu de
evacuare a fumului (dup dezasamblarea conexiunii cu canalul de conducere a gazelor spre co) sau printr-
o deschidere special din conexiune.
Boilerul nu se va mbcsi dac sistemul de nclzire este corect montat; canalul de conducere a
gazelor spre co este n stare bun i este folosit conform recomandrilor din manual. Distribuitorul
de aer este cobort, poate aduna cenu veche, de aceea trebuie verificat i curat.
Dac o sprtur dintre plcile inferioare este redus sau dispare, trebuie reparat dup dezasamblarea
distribuitorului. Cablul mecanismului de ridicare trebuie gresat astfel nct s nu se uzeze, iar distribuitorul
-
21
va fi ridicat mai uor. Recomandm gresarea uii prin nchiderea ambelor crlige. Uneori trebuie s se
verifice dac nchiderea uilor i locul dintre podelele de ciment i boiler se afl n stare bun. nlturai
problemele nchiderii folosind materialele rezistente la cldur menionate mai sus. Pentru a uile s fie
nchise ermetic, materialele de etanare trebuie nlocuite.
6. CERINE N VEDEREA PREVENIRII ACCIDENTELOR
Boilerul este o zon cu potenial crescut de pericol. Dac v comportai iresponsabil, este posibil s v rnii, s v intoxicai, s provocai un incendiu, s defectai boilerul sau sistemul de nclzire.
CERINE DE SIGURAN I INTERZICERI CONSECINELE NERESPECTRII
INTERZICERILOR I A MSURILOR
Nu fierbei apa din boiler.
Dac apa fierbe, boilerul se va supranclzi i va ceda.
Dac boilerul va fierbe din motive necunoscute, stai
cu faa departe de ui, deschidei-le i turnai ap n
focar.
Nu aprindei boilerul fr ap. Nu permitei ca
presiunea din sistem s fie mai mare de 1.5 bar. Nu
turnai ap foarte rece n sistemul de nclzire i n
boiler.
Defectarea boilerului i a altor piese din
sistemul de nclzire.
Aerul de afar trebuie s intre n camera
boilerului.
Este posibil s v intoxicai lng boiler chiar dac
acesta nu funcioneaz deschidei o fereastr n
camera boilerului sau introducei aer n camer prin
alte mijloace.
Nu introducei aer prin ua de jos i nu ncrcai lemne prin partea de jos
Condensul se va scurge; se va consuma i mai mult
lemn. Apa va fierben boiler, crbunele va cdea.
Nu depozitai combustibil n boiler (dup
ncrcarea lemnului, acesta trebuie aprins)
Lemnul de foc va lua foc din cauza cenuii fierbini i
va fumega producnd condens i gudron.
Nu deplasai distribuitorul de aer pe durata arderii.
Cnd cobori distribuitorul de aer, se va plia, iar dac
este introdus mai adnc n combustibil se va uza mai
repede de la cldur.
-
22
CELE MAI FRECVENTE GREELI DE
MONTAJ CONSECINE/ NLTURARE
Este montat conform schielor altor productori de boilere pentru c exist
posibilitatea de retur a unei cantiti mari de ap cald, aducnd dup sine un efect
negativ precum condensul.
Debitul intens rcete suficient compartimentele de ardere i pereii plini de fum, astfel nct umezeala se va prelinge pe perei dei uscat pe durata nclzirii, dar poate lipi cenua pe perei, ducnd la mbcsirea
periodic a boilerului i a coului de fum. Setai debitul recomandat umezeala se va
acumula sub focarul de combustie crpturile de fum vor fi mereu curate.
Pompa circular mpreun cu boilerul este montat pe vechiul sistem unde
elementele nu sunt reglate
Datorit unui debit intens de ap rece, se descarc mult condens, un mirox puternic intoxicant intr n camera boilerului, iar
acesta funcioneaz la o capacitate neeconomic ce i poate diminua capacitatea. Montai un robinet de
echilibrare n faa boilerului sau nuntrul acestuia.
GREELI COMUNE DE UTILIZARE
Se arde cnd tirajul canalului de
conducere a gazelor spre co este prea
puternic
Se aude un puls n boiler. Uneori aerul din supape sare. Boilerul funcionez foarte
neeconomic, condensul se scurge,
capacitatea scade. Rotii supapa de reglare a manetei n sus i fixai-o astfel nct tirajul s deschid uor supapa de injecie. Dac ai achiziionat boilerul fr un canal de
conducere a fumului spre co, este suficient s tiai o seciune n form de U n grinda orizontal i s ndreptai gradat limba
format pn ce funcionarea boilerului se stabilizeaz.
Cablul de distribuie a aerului nu este gresat.
Distribuitorul de aer este rigicat cu greutate,
cablul se uzeaz. Trebuie gresat cu un
lubrefiant WD 40 sau vaselin.
Ambalaje de plastic sau de carton sunt arse
n boiler
Dac arderea este ntrziat de bucile de carton, atunci plasticul sau ambalajele
sunt periculoase deoarece genereaz gaze, nu ard unifrom, excesul acumulat poate
genera explozie, sprgnd conectorii canalului de conducere a fumului spre
co.
Se menine o temperatur de 60C a boilerului
Boilerul i canalul de conducere a fumului
spre co sunt mbcsite din cauza
condensului.
-
23
7. EVALUAREA RISCULUI
7.1. PERICOLE REFERITOARE LA NCLZIRE
Este posibil s v alegei cu arsuri din cauza atingerii elementelor boilerului. Suprafaa boilerului
care poate fi nclzit pn la o temperatur de 40 C i alte pri conform caracteristicilor tehnice, este
izolat dar mai exist pri precum mnerele uilor i uile care sunt fierbini i periculoase. Astfel de
locuri sunt marcate printr-o inscripie internaional. evile cu ap fierbinte ale sistemului de nclzire
trebuie izolate, dup testul hidraulic. Supapa de presiune a conductei de evacuare trebuie s duc la
canalizare. Trebuie lsat o deschiztur de 10 cm pentru monitorizare i izolare.
7.2. PERICOLE REFERITOARE LA PRESIUNE
Creterea presiunii este posibil: cnd tensiunea cade i pompa circular se oprete, boilerul nu este
reumplut cu ap rece din sistem iar temperatura atinge nivelul periculos cnd regulatorul de tiraj este
activat prin nchiderea unei supape la setarea modului de temperatur, nepermind aerului s intre i
stingnd boilerul. Temperatura poate atinge nivelul critic de 100 C din inerie dar apa nu va fierbe n
boiler deoarece mulumit unei metode de ardere. Dac supapa de nchidere este deformat sau din cauza
altor nclcri ale regulilor de funcionare (de exemplu ua compartimentului de cenu este deschis), apa
din boiler poate ncepe s fiarb. Totui supapa de protecie a presiunii montat pe conducta superioar a
debitului de alimentare elibereaz vapori i nu depete presiunea, permind boilerului s se umple cu
ap dintr-o conduct a sistemului, pentru a se rci.
n caz utilizare necorespunztoare: de exemplu, dei aerul este introdus printr-o u inferioar n
boiler, datorit arderii intensive din boiler, capacitatea sa este depit de mai multe ori, astfel c boilerul
poate fierbe apa, iar dac este supranclzit, se poate fisura din cauza presiunii normale.
Boilerul se poate fisura i din cauza unei presiuni prea mari, dac supapa de protecie a presiunii este
montat ntr-un loc necorespunztor sau este mbcsit. Dup cum o dovedesc calculele i practica,
boilerul nu va exploda n afar ci va crpa pe dinuntru, prin urmare nu exist pericol pentru sntatea sau
viaa oamenilor.
7.3. POSIBIL INTOXICARE
Cnd canalul de conducere a gazelor spre co este mbcsit sau cnd este curat de cenu, n
camera boilerului se poate acumula monoxid de carbon, prin urmare este nevoie de o ventilaie natural,
iar pentru funcionarea sa aceast ventilaie afluent este necesar prin deschiderea unei mici ferestre pe
peretele lateral al camerei boilerului. Dac nu exist o ventilaie afluent, boilerul nu a funciona. Prin
urmare nu uitai s instalai un sistem de ventilare interioar a boilerului n peretele acestuia sau n camer,
direct de afar. Ua camerei boilerului trebuie strns bine astfel nct unitatea sanitar de urgen saau
-
24
ventilaia buctriei sunt pornite, funcionarea boilerului nu va fi afectat, iar praful sau monoxidul de
carbon nu vor trece din camera boilerului n cas.
7.4. CERINE PENTRU CONECTAREA PIESELOR ELECTRICE
Pompele circulare sunt montate pe sistem i folosesc curent electric. Acestea trebuie conectate de o
persoan care are calificarea de tehnician i permis pentru o astfel de lucrare. Lucrrile de montaj trebuie
efectuate conform proiectului (lund n considerare capacitatea general de intrare). Curentul electric
poate afecta omul! Conexiunile electrice trebuie izolate, trebuie s aib mpmntare, iar instalaia trebuie
fcut conform standardelor valabile n ara respectiv.
JSC "STROPUVA ir KO", Cod de identificare fiscal: 300149972, Adres: Vaduvos str., 2A,
LT-02304 Vilnius, telefon: +370 5 255 1763, fax. +370 5 232 2525, mob. +370 656 16223, E-
mail: [email protected] or [email protected], www.stropuva.lt
CONFIGURARE
1. Supapa de alimentare cu aer (montat n partea superioar a boilerului);
2. Stand de lemn pentru controlerul termic (montat cu ajutorul unei benzi lng ua prin care se realizeaz ncrcarea);
3. Supap de protecie a presiunii, 1.5 bar;
4. Termometru;
5. Co de fum cu alimentare regulat cu aer;
6. Colector injecie cu aer (pentru boilerele adaptate s ard crbunele);
7. Distribuitor tubular aer (pentru boilerele adaptate s ard crbunele).
Recomandm achiziionarea unui generator de rezerv n cazul n care survine o pan de curent.
ATENIE: Eliberai regulatorul de tiraj din prinderile sale; tragei-l deasupra barei de pe laterala boilerului, indicatorul superior al regulatorului de tiraj montat n deschiztura injeciei cu aer.
TERMENI DE GARANIE A PRODUSULUI
Productorul garanteaz c produsul corespunde cerinelor documentaiei tehnice.
Productorul ofer o garanie de doi ani boilerului.
Productorul ofer o garanie de cinci ani schimbtorului de cldur al boilerului.
Productorul se oblig s rezolve defectele datorate unei avarii a productorului.
Utilizatorul, prin achiziionarea boilerului se oblig:
1. S monteze boilerul i s-l utilizeze conform recomandrilor din acest manual.
2. S studieze & s nvee acest manual de utilizare! 3. S pstreze acest document de garanie i notiele n siguran!
Productorul nu i asum nicio obligaie pentru funcionarea boilerului i consecinele ulterioare i nu va oferi garanie n urmtoarele cazuri:
1. Alimentarea cu energie electric nu ntrunete cerinele casei,
2. Boilerul este montat n neconcordan cu recomandrile acestei fie de date,
3. Boilerul funcioneaz n neconformitate cu recomandrile acestui Manual,
4. Garania produsului nu este valabil fr un document de garanie.
-
25
CERTIFICAT DE GARANIE
Boilerul termic are o garanie de doi ani.
Schimbtorul de cldur are o garanie de cinci ani.
Boiler ______________________________________________________________________________
Produs numrul ____________________________________________________________________
Data nceperii perioadei de garanie _______________________________________________
Semntura vnztorului, tampila, data
-
26
-
27
CERTIFICAT
Certificat de examinare de tip EC
(certificat de conformitate)
Conform Directivei Echipamentelor sub Presiune 97/23/EC
Certificat nr. 0662/0288/05
Numele i adresa productorului:
UAB STROPUVA Vaduvos g. 2A
LT-02304 Vilinius
Prin prezentul se atest faptul c modelul ansamblurilor de generare a apei calde conform articolului 3, paragraf 2.3 de mai jos, ntrunete cerinele Directivei Echipamentelor sub Presiune 97/23/EC, Anexa I, seciunile 2.10, 2.11, 3.4, 5(a) i 5 (d).
Descrierea echipamentului sub presiune: Tipuri nr S7, S10, S20 i S40
Categorie: Articolul 3, paragraful 3
Raport de examinare nr LT08/056/05
Schia nr: VR 00.00.SB
Cod de fabricaie: EN 303-5, EN 12828
Gera, 18.05.2005 tampila TUV Thuringen e.V Organism notificat
Semntur indescifrabil TUV CERT Organism de certificare pentru echipamentele sub presiune ale TUV
Thuringen e.V
Organism notificat 0090, 97/23/EC
Melchendorfer Str. 64, D-990096 Erfurt