sectiune transversala propunere volumetrica transversale rete… · sectiune transversala propunere...

1
NOTĂ NAVIGATOR ORIENTARE SISTEMUL DE MANAGEMENT CERTIFICAT CONFORM STANDARDUL DE REFERINȚĂ SR EN ISO 9001: 2001 Nr. Certificat: UIG-1014-EJ-761 N ARH. CRISTIAN LASCU ARH. CIPRIAN LIPOVAN www.apbenta.ro PROIECT ORADEA, STR. EFORIEI,NR. 3-5, JUD. BIHOR NR. CAD.:196434; NR. CF.: 196434 280/14.06.2017 1305/2017 BENEFICIAR ADRESĂ OBIECTIV NUMĂR CONTRACT NUMĂR PROIECT RECONVERSIE FUNCTIONALA DIN ZONA DE ACTIVITATI ECONOMICE - Et in zona mixta - M3 S.C. ISTIALIS S.R.L. FAZĂ PROIECT DATA SCARA NR. PLANȘĂ PLANȘĂ SECTIUNE - VOLUMETRIE PROPUSA P.U.Z. 01 / 2018 1:500 U08 PROIECTANT ATELIER DE PROIECTARE BENȚA 410057 - ORADEA, JUD. BIHOR, STR. GENERAL MAGHERU, NR. 21 / 125 T./F. +4 0359.80.08.17 | E: offi[email protected] PROIECTAT ȘEF PROIECT DESENAT ARH. OVIDIU BENTA ARH. ADRIAN PEREDERCU ARH. CIPRIAN LIPOVAN ARH. ADRIAN PEREDERCU ARH. CRISTIAN LASCU 4.55 1.10 4.94 5.22 5.00 2.62 4.87 3.00 38.00 3.00 5.00 6.00 5.00 3.00 38.00 1.50 22.00 19.00 28.00 38.00 18.00 24.00 27.00 15.00 3.00 6.00 3.00 3.00 3.00 15.00 9.00 2.00 4.00 1.00 28.00 30.00 16.00 19.00 25.00 19.00 1.50 5.00 3.00 3.00 5.00 1.50 17.50 1.50 1.00 5.00 2.50 2.50 5.00 variabil 1.80 5.00 (variabil) 11.00 (variabil) variabil 1.80 6.00 5.00 1.50 6.00 (variabil) 27.00 VARIABIL 31.30 1.70 13.00 3.00 2.75 6.00 5.00 variabil 3.00 5.00 6.00 1.50 15.50 5.00 6.00 5.00 1.00 3.00 20.00 1.00 3.00 3.00 1.00 8.00 variabil 6.00 2.501.00 1.00 10.50 12.00 2.25 5.50 2.00 2.25 2.25 2.00 5.50 2.25 16.75 LARGIRE PROFIL DRUM P E1 E2 E3 E4 E5 E6 E7 E8 P E1 E2 E3 E4 E5 E6 E7 E8 D C C P/V T T P/V C - CAROSABIL T - TROTUAR P - PARCARI V - S. VERZI Acest desen se va citi în corelație cu restul proiectului tehnic înainte de începerea execuției, se vor verifica dimensiunile din acte ale terenului, de către un topograf autorizat. Proiectantul nu isi asuma responsabilitatea pentru modificarile aduse proiectului, fără acceptul în prealabil al acestuia. Înainte de executarea tâmplariilor se va verifica pe șantier dimensiunea reală a golurilor pentru uși și ferestre. Proiectantul trebuie anunțat imediat despre orice neregulă a proiectului tehnic descoperită în timpul execuției. Proiectantul își asumă responsabilitatea asupra proiectului doar în situația în care construcția este executată cu constructor autorizat, respectând legile în vigoare. Dreptul de autor al acestui proiect aparține: S.C. ATELIER DE PROIECTARE BENȚA S.R.L. Sectiune transversala propunere volumetrica C C P/V T T P/V PROFIL(2) DRUM PUBLIC PROPUS - 19.00m C C P P T V C - CAROSABIL T - TROTUAR P - PARCARI V - S. VERZI PROFIL(3) DRUM DE INCINTA PROPUS - 17.50m C C T V VP I C - CAROSABIL T - TROTUAR VP - PARC V - VERZI PROFIL EXISTENT STR. NASAUDULUI - 5.00m (variabil) I - RETELE TERMOFICARE T P VP I C - CAROSABIL T - TROTUAR VP - PARC V - VERZI PROFIL(1) STR. NASAUDULUI PROPUS - 6.00m I - RETELE TERMOFICARE C C V P+4 C C T T P P V V V EXISTENT Nota: Profilul drumului existent (Str. Nasaudului) in dreptul parcelei se va largi la un profil de 6.00m iar infrastructura (retele termoficare) se propun a se introduce in subteran. T V P C C P T C - CAROSABIL T - TROTUAR P - PARCARI V - S. VERZI PROFIL(4) DRUM PUBLIC PROPUS - 16.75m T P/V C C V C - CAROSABIL T - TROTUAR P - PARCARI V - S. VERZI PROFIL(5) DRUM PUBLIC PROPUS - 15.50m V C C T P P PROFIL(6) DRUM PUBLIC PROPUS - 20.00m C - CAROSABIL T - TROTUAR P - PARCARI V - S. VERZI C C T T PROFIL(8) DRUM PUBLIC PROPUS ZONA M4 - 8.00m C - CAROSABIL T - TROTUAR C C T V V P/V PROFIL(9) DRUM PUBLIC PROPUS ZONA M4 - 10.50m C - CAROSABIL T - TROTUAR P -PARCARI T T P C/B C/B PROFIL(7) DRUM PUBLIC PROPUS ZONA M4 - 12.00m B - PISTA PENTRU BICICLISTI

Upload: others

Post on 18-Oct-2020

22 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sectiune transversala propunere volumetrica transversale rete… · Sectiune transversala propunere volumetrica T P/V C C P/V T PROFIL(2) DRUM PUBLIC PROPUS - 19.00m T V P C C P C

NOTĂ

NAVIGATOR ORIENTARE

SISTEMUL DE MANAGEMENT CERTIFICAT CONFORMSTANDARDUL DE REFERINȚĂ SR EN ISO 9001: 2001

Nr. Certificat: UIG-1014-EJ-761

N

ARH. CRISTIAN LASCUARH. CIPRIAN LIPOVAN

www.apbenta.ro

PROIECT

ORADEA, STR. EFORIEI,NR. 3-5, JUD. BIHORNR. CAD.:196434; NR. CF.: 196434

280/14.06.2017 1305/2017

BENEFICIAR

ADRESĂ OBIECTIV

NUMĂR CONTRACT NUMĂR PROIECT

RECONVERSIE FUNCTIONALA DIN ZONA DEACTIVITATI ECONOMICE - Et in zona mixta - M3

S.C. ISTIALIS S.R.L.

FAZĂ PROIECT DATASCARA NR. PLANȘĂ

PLANȘĂ

SECTIUNE - VOLUMETRIE PROPUSA

P.U.Z. 01 / 20181:500 U08

PROIECTANT

ATELIER DE PROIECTARE BENȚA410057 - ORADEA, JUD. BIHOR,STR. GENERAL MAGHERU, NR. 21 / 125T./F. +4 0359.80.08.17 | E: [email protected]

PROIECTAT

ȘEF PROIECT

DESENAT

ARH. OVIDIU BENTAARH. ADRIAN PEREDERCUARH. CIPRIAN LIPOVAN

ARH. ADRIAN PEREDERCU

ARH. CRISTIAN LASCU

4.55 1.10 4.94 5.22 5.00 2.62 4.87 3.00 38.00 3.00 5.00 6.00 5.00 3.00 38.00 1.50

22.00

19.00

28.00

38.00

18.00 24.00

27.00

15.00

3.00

6.00

3.00

3.003.00

15.00

9.00

2.00

4.00

1.00

28.00

30.00

16.00

19.0025.00

19.001.50 5.00 3.00 3.00 5.00 1.50

17.501.50 1.00 5.00 2.50 2.50 5.00variabil

1.80 5.00(variabil)

11.00(variabil)

variabil1.80 6.00 5.00 1.506.00

(variabil)

27.00VARIABIL

31.30

1.70

13.00

3.00 2.75 6.00 5.00 variabil

3.00 5.00 6.00 1.5015.50

5.00 6.00 5.00 1.00 3.0020.00

1.00 3.00 3.00 1.00

8.00

variabil 6.00 2.501.00 1.0010.5012.00

2.25 5.50 2.002.252.25 2.00 5.50 2.25

16.75

LARGIRE PROFIL DRUM

PE1E2E3E4E5E6E7E8

PE1E2E3E4E5E6E7E8

DC C P/V TT P/V

C - CAROSABIL T - TROTUARP - PARCARI V - S. VERZI

Acest desen se va citi în corelație cu restul proiectului tehnicînainte de începerea execuției, se vor verifica dimensiunile din acte aleterenului, de către un topograf autorizat. Proiectantul nu isi asumaresponsabilitatea pentru modificarile aduse proiectului, fără acceptul înprealabil al acestuia. Înainte de executarea tâmplariilor se va verifica peșantier dimensiunea reală a golurilor pentru uși și ferestre. Proiectantultrebuie anunțat imediat despre orice neregulă a proiectului tehnicdescoperită în timpul execuției. Proiectantul își asumă responsabilitateaasupra proiectului doar în situația în care construcția este executată cuconstructor autorizat, respectând legile în vigoare.

Dreptul de autor al acestui proiect aparține:S.C. ATELIER DE PROIECTARE BENȚA S.R.L.

Sectiune transversalapropunere volumetrica

C C P/V TT P/V

PROFIL(2) DRUM PUBLIC PROPUS - 19.00m

C C PPT V

C - CAROSABIL T - TROTUARP - PARCARI V - S. VERZI

PROFIL(3) DRUM DE INCINTA PROPUS - 17.50m

C CT VVP

I

C - CAROSABIL T - TROTUARVP - PARC V - VERZI

PROFIL EXISTENT STR. NASAUDULUI - 5.00m (variabil)

I - RETELE TERMOFICARE

T PVP I

C - CAROSABIL T - TROTUARVP - PARC V - VERZI

PROFIL(1) STR. NASAUDULUI PROPUS - 6.00m

I - RETELE TERMOFICARE

C C V

P+4

C C TT P P VVV

EXISTENT

Nota:Profilul drumului existent (Str. Nasaudului) in dreptul parceleise va largi la un profil de 6.00m iar infrastructura(retele termoficare) se propun a se introduce in subteran.

T VPCCPT

C - CAROSABIL T - TROTUARP - PARCARI V - S. VERZI

PROFIL(4) DRUM PUBLIC PROPUS - 16.75m

T P/V C C V

C - CAROSABIL T - TROTUARP - PARCARI V - S. VERZI

PROFIL(5) DRUM PUBLIC PROPUS - 15.50m

VCC TP P

PROFIL(6) DRUM PUBLIC PROPUS - 20.00m

C - CAROSABIL T - TROTUARP - PARCARI V - S. VERZI

C C TT

PROFIL(8) DRUM PUBLICPROPUS ZONA M4 - 8.00m

C - CAROSABIL T - TROTUAR

C C T VV P/V

PROFIL(9) DRUM PUBLICPROPUS ZONA M4 - 10.50m

C - CAROSABIL T - TROTUARP -PARCARI

T TPC/B C/B

PROFIL(7) DRUM PUBLIC PROPUS ZONA M4 - 12.00m

B - PISTA PENTRU BICICLISTI