-SE UTILIZEAZA DOAR LA INDICATIA MEDICULUI -TREBUIE OMOLOGATE -IES DIN GARANTIE DACA SUNT IMPROPRIU FOLOSITE -TREBUIE INCERCATE INAINTE DACA SUNT COMPLETE SI FUNCTIONALE, PENTRU A SE PROTEJA PERSONALUL SI BOLNAVII, -REPARATIILE SE FAC DUPA DE CONTA -MINARE

ECHIPAMENTELE CELIOSCOPICE

ECHIPAMENTE CELIOSCOPICE TREBUIE TINUTE FARA UMEZEALA SE FOLOSESC DOAR ACCESORII ORIGINALE SE CITESTE CARTEA DE ISTRUCTIUNI MEDICUL ESTE RESPONSABIL DE TOATE VOLTAJUL LA PRIZA ESTE CEL BUN? CELE ELECTRICE NU SE FOLOSESC IN VAPORI INFLAMABILI SE FOLOSESC SIGURANTE DE ACELASI TIP ACCESORIILE MEDICALE SE FOLOSESC

ECHIPAMENTE CELIOSCOPICE TESTUL DE FUNCTIONARE SE FACE INAINTE DE FIECARE OPERATIE SE LUCREAZA CU SOLUTII STERILE SE CURATA, DAR SE STERILIZEAZA DOAR PARTEA CARE INTRA IN CIMPUL OPERATOR TREBUIE UN SET DE REZERVA GATA DE FUNCTIO- NARE IN CAZ DE SUSPICIUNE DE DEFICIENTA,SE OPRESTE ECHIPAMENTUL PT.A FI VERIFICAT DE PERSONALUL AUTORIZAT POMPA DE ASPIRATOR ARE PRESIUNE DE 400MM

ECHIPAMENTE CELIOSCOPICE A SE VERIFICA DACA TUBURILE NU SUNT IMPLETITE SAU INTORTOCHIATE A SE UTILIZA FILTRE BIOLOGICE SI HIDROFOBICE INTRE PACIENT SI APARAT SE UTILIZEAZA RECIPIENTE FLEXIBILE DE ASPIRATIE (CELE DE STICLA POT EXPLODA) POATE APARE EMBOLIE GAZOASA DACA SE INSTILEAZA AER IN LOC DE LICHID TREBUIE IN ORICE MOMENT UN RECIPIENT DE REZERVA,PLIN

ECHIPAMENTE CELIOSCOPICE A SE FOLOSI ACCESORII DECONTAMINTE TEMPERATURA AMBIENTALA ESTE DE 10-40 DE GRADE CELSIUS UMIDITATEA ADMISA ESTE DE ESTE DE 30-75% ALIMENTAREA CU CURENT SE FACE IN PRIZA FIXA LA PERETE SCHIMBAREA RECIPIENTELOR DOAR CU APARATUL INCHIS ASPIROLAVORUL SE AUTOOPRESTE CIND PRESIUNEA ESTE MAI MARE DE 500 MM Hg

ECHIPAMENTE CELIOSCOPICE DACA POMPA ASPIROLAVORULUI NU PORNESTE,ESTE O FISURA IN SISTEM TUBURILE SUNT UMPLUTE INANTE DE OPERATIE SISTEMUL SE PORNESTE PE ASPIRATIE SAU LAVAJ CAND APASAM CLAPELE TIJEI TUBURILE SE CLATESC CU APA CURENTA, DEMINERALI ZATA STERILIZAREA SE FACE CU ECHIPAMENTUL ASAMBLAT TUBURILE SE AUTOCLAVEAZA LA 134 GRADE, 5 MIN LA 3 BARI SAU CU OXID DE ETILENA

ECHIPAMENTE CELIOSCOPICE DEZINFECTIA LA RECE SE FACE PRIN IMERSIE COMPLETA IN SOLUTII APROBATE DE PRODUCA -TOR, DUPA CARE SE CLATESC CU APA STERILA APARATELE SE VERIFICA DE SPECIALISTI,ANUAL CONTAINERUL DE ASPIRARE ESTE DE 3 L,IAR DE INSTILARE DE 2 LITRI, FLUXUL DE ASPIRARE/LAVAJ ESTE 1,8L/MIN VOLTAJUL ESTE DE 220-240 V,SIGURANTA DE 500mA DEPOZITAREA SE FACE INTRE -40 SI 70 GRADE

ECHIPAMENTE CELIOSCOPICE COMPONENTELE CONTIN SUBSTANTE NOCIVE CARE POLUEAZA FIRELE DE ALIMENTARE CU CURENT SUNT TREI : - FIRUL GALBEN CU VERDE IMPAMANTAREA, - ALBASTRU-NEUTRALUL, - MARO-FAZA MONITORUL POATE FI INTERFERAT DE RADIO- UNDE DATORATE ACTIVITATII ALTOR APARATE TREBUIE RESPECTAT STANDARDUL ISO CAND SUNT MULTE APARATE IN ARIA BOLNAVULUI (1,5 MIN JURUL LUI), ELE TRBUIE SA AIBA IMPAMANTARI SEPARATE

ECHIPAMENTE CELIOSCOPICE PERSONALUL NU TREBUIE SA ATINGA CONCOMITENT BOLNAVUL SI APARATUL SE SCOATE APARATUL DIN PRIZA INTRE FUNCTIONARI (TRAS DE STECHER, NU DE FIR) A SE LASA SPATIU DE RACIRE PENTRU APARAT A NU SE BLOCA ORIFICIILE DE AERISIRE ALE APARATULUI A NU SE LASA APARATUL LANGA SURSE DE CALDURA, LA LUMINA SOLARA,IN VIBRATII SAU SOCURI

ECHIPAMENTE CELIOSCOPICE TUBUL SONY TRINITRON ARE:600 LINII ORIZONTALE, FILTRU ANTIDISTORSIUNE A IMAGINII,BALANTA DE ALB STABILA,CORECTARE RGB,SINCRONIZARE,DEMAGNETI- ZARE SURSA DE LUMINA ARE INTENSITATEA LUMINII INTRE 0 SI 100%;ARE OBTURATOR AUTOMATIC IN FUNCTIE DE APROPIEREA TELESCOPULUI DE SITUSUL OPERATOR SAU DE LUMINOZITATEA CAMPULUI OPERATOR PT.SISTEMUL MANUAL,LUMINOZITATEA ESTE 30-70% CU CAT INTENSITATEA LUMINII ESTE MAI MARE ,CU ATAT CRESTE SI TEMPERATURA LA CAPATUL TELESCOPULUI

ECHIPAMENTE CELIOSCOPICE INTERCONEXIUNI :PANOUL POSTERIOR AL UNITATII DE CONTROL A CAMEREI VIDEO (VIDEO OUT) LA SURSA DE LUMINA (VIDEO IN);CABLUL S-VHS DE LA IESIREA S-VHS A PANOULUI POSTERIOR A UNITATII DE CONTROL A CAMEREI VIDEO LA INTRAREA Y/C DIN SPATELE MONITO -RULUI LAMPA DE XENON ARE 300W SI FUNCTIONEA ZA 500 ORE BECUL TREBUIE SA FUNCTIONEZE MACAR 5 MIN EXISTA LAMPA DE AVARIE CU CARE SE CONTINUA

ECHIPAMENTE CELIOSCOPICE CAMERA VIDEO: -GAIN:MARESTE LUMINOZITATEA; -SHUTTER AUTO : ISI AJUSTEAZALUMINOZITATEA -ZOOM:MARESTE IMAGINEA; -CAPUL CAMEREI SE ACOPERA IN REPAUS; -BUCLA FIRULUI OPTIC ARE MINIMUM 25MM DIAMETRU STERILIZAREA SE FACE CU GLUTARALDEHIDA 2 %, 10MIN, LA 25 DE GRADE,IAR CU

ECHIPAMENTE CELIOSCOPICE PT. A PRELUNGI DURATA DE VIATA A CAMEREI VIDEO,ACEASTA SE TINE MAXIM 3 ORE IN OXID DE ETILENA LA MAX. 60 DE GRADE,IAR IN GLUTARALDEHI- DA MAX.24 ORE;A NU SE AUTOCLAVA TELESCOAPELE MAI INGUSTE TRANSMIT LUMINA MAI PUTIN INSUFLATORUL ARE DEBIT 16-40 L/MIN;DA UN ZGOMOT DE SUB 40 DECIBELI,PRESIUNEA PRESELECTA -TA ESTE DE 5-25 MM Hg, LUNGIMEA TUBULUI DE TREI METRI;TUBUL DE PRESIUNE ARE 1M,ARE INCALZITOR DE CO2 SI AC VERESS DE 120

ECHIPAMENTE CELIOSCOPICE CAMERA VIDEO RASPUNDE LA O ILUMINARE DE 1 LUX, ARE 752(H)/582(V) LINII , MARIMEA PIXELULUI ESTE DE 8,6(H)X8,3(V)MICROMETRI, REZOLUTIA ORIZONTALA ARE >480 LINII TV SI ZOOMUL OBIECTIV ESTE f=25-40 MM LAMPA DE AVARIE A SURSEI DE LUMINA ARE 24V, 250W SI 50 ORE DE FUNCTIONARE CABLUL DE FIBRE OPTICE ESTE INCASTRAT IN SILICON,ESTE AUTOCLAVABIL LA 134 GRADE,LA 2-3

ECHIPAMENTE CELIOSCOPICE BISTURIUL ELECTRIC ARE P 400 W,POATE FI MONO-SAU BI-POLAR,POATE FI: -DE SECTIUNE-400W,300 OHMI,2300Vpp; -DE COAGULARE 250 W,200 OHMI,3200Vpp; -DE SPRAY-120 W,6000 Vpp; -BIPOLAR-100 W,600 Vpp MONITORUL ESTE DE 15 SAU 21 INCH, CU >600 LINII, FARA REFLEXIE, FARA RADIATIE, ESTE AUTOMAT PAL,NTSC,SECAM ARE MICROPROCESOR,REZISTENTA DE 75 OHMI,ARE 2xVHS,2xBNC,2xAUDIO,UN CONSUM DE 80-100 W, ARE 16 MILIOANE DE CULORI SI ESTE CU SINCRONIZARE AUTOMATA

ECHIPAMENTE CELIOSCOPICE TREBUIE EVITATA PRESIUNEA INTRAABDOMINA- LA MAI MARE DE 20 MM Hg,CARE POATE DUCE LA MOBILITATE REDUSA A DIAFRAGMULUI,RETUR VENOS SCAZUT, DEBIT CARDIAC SCAZUT, ACIDOZA, INSUF. PULMONARA SI DEZECHILIBRU METABOLIC,CORELAT CU ABSORBTIA EXCESIVA A CO2 (RISC DE EMBOLIE) INSUFLATORUL SE ASEAZA DEASUPRA NIVELULUI ABDOMENULUI INSUFLATORUL SE AUTOOPRESTE CAND PRESIUNEA INTRA-ABDOMINALA AJUNGE LA PRES.PRESELECTATA IN APARAT

ECHIPAMENTE CELIOSCOPICE LA BIST.ELECTRIC, ELECTRODUL NEUTRU SE APLICA PE BOLNAV LA MICA DISTANTA DE ZONA DE LUCRU ELECTRODUL ACTIV SE FOLOSESTE NU MAI APROAPE DE 15 CM DE INIMA SAU DE PACE MAKER CABLURILE DE MONOPOLAR SI BIPOLAR, ACTIVE CONCOMITENT,TREBUIE SA FIE LA DISTANTA DE MINIM 10 CM INTRE ELE SI NU PE PIELEA BOLNAVULUI FRECVENTA UDELOR PRODUSE DE BIST.ELECTRIC ESTE DE 450 KHZ,IAR CELE PULSATILE DE 30 KHZ SONOTOM=BISTURIU CU ULTRASUNETE= ARE TREI COMENZI SI FUNCTII:CAVITATIE+ASPIRATIE+IRIGATIE;ESTE

ECHIPAMENTE CELIOSCOPICE INSTRUMENTARUL TREBUIE ULEIAT INAINTE DE STERILIZARE CU ULTRASUNETE;NU SE STERILIZEAZA CU ACID PERACETIC STERILIZAREA LA VAPORI (AUTOCLAV) SE FACE LA 134 GRADE,IAR STERILIZAREA PLASTICULUI LA 120 GRADE INSTRUMENTARUL SE SPALA IMEDIAT DUPA ATINGEREA DE SUBSTANTE COROZIVE (CHIAR SI DE SERUL FIZIOLOGIC) INSTRUMENTELE NU TREBUIE LOVITE (CARBURA DE TUNGSTEN DE LA LIPITURI POATE SARI) INSTRUMENTELE TREBUIE TINUTE USCATE

ECHIPAMENTE CELIOSCOPICE -INSTRUMENTELE ARTICULATE SE PUN DESFACUTE IN SOL.DEZINFECTANTA -REZIDUURILE COAGULATE SE SPALA CU APA OXIGENATA -SE PREFERA SOLUTIA DECAT CALDURA -SE SPALA IN MASINI SPECIALE -SE ASTEAPTA DIZOLVAREA PUDREI DE STERILIZANT -PLASTICUL SI CAUCIUCUL SE SPALA FARA DECAPANT,FARA PERII DE SARMA -SE SPALA CU APA DEMINERALIZATA SI SE USUCA CU PISTOL DE AER -DETERGENTII AU pH NEUTRU -DEZINFECTIA SI SPALAREA NU SE FAC LA TEMP.>60 GRADE

ECHIPAMENTE CELIOSCOPICE -A NU SE USCA LA TEMP.>95 GRADE -ULTRASUNETELE POT STERILIZA INSTR.DIN OTEL INOX;ELE ACTIONEAZA CU 35KHZ,3MIN -FRICTIUNILE DUC LA COROZIUNE -STERILIZAREA LA AER CALD (POUPINEL) NU SE FACE LA TEMP.> SAU < DE 180 GRADE -O SOL. DE CLORURA DE SODIU >200 ml/L(120 mg/L CLOR) FACE APA CORODANTA -PRINCIPALUL METAL DIN INSTR.ESTE CROMUL(13%) SI Ni-Cr(REZISTENT LA ACIZI DAR NU LA SOCURI),ALUMINIUL

ECHIPAMENTE CELIOSCOPICECONTROLUL OPTIC AL INSTRUMENTELOR -PETELE GALBEN-BRUNE (RUGINA) CONTIN CLORIT,SI TREBUIE INDEPARTAT CAT MAI REPEDE-SE TRANSMITE SI LA CELELALTE INSTR. -CAUCIUCUL SI LATEXUL IMBATRANESC MAI REPEDE LA : TEMP.>80 GRADE,ULTRAVIOLETE,HALOTAN,ULEI DE PARAFINA,ULEI SILICONIC

ECHIPAMENTE CELIOSCOPICELA SONOTOM -UNGHIUL DE INCLINATIE