  • 8/12/2019 Dantec Dynamic

    1/8

    SMART SOFTWARE FOR IMAGING SOLUTIONS

    Complex Tasks Made Easy With DynamicStudio

  • 8/12/2019 Dantec Dynamic

    2/8

    A magnetic mixing experiment in micro scale, displaying the fingeringpattern of the Labyrinthine instability between the magnetic fluid (blue)and solvent (red). Courtesy of University of Latvia, Department of Physics.

  • 8/12/2019 Dantec Dynamic

    3/8

    DynamicStudio is the revolutionary software platform foradvanced imaging experiments, including easy set-up and

    control of hardware, data acquisition and storage, fastanalysis and presentation of results. The user interface is

    intuitive with plug-and-play connection of cameras, synchro-nization devices and other hardware.

    Increasing camera resolution, frame rate and the simultane-ous use of multiple cameras generate huge amounts of data.

    DynamicStudio handles the data intelligently by distributingdata acquisition, storage and processing to GPUs and any

    number of PCs over a network.This combined with a flexible database structure and

    advanced analysis, post-processing and visualization modulesincluding support for 3D vision displays and glasses make

    DynamicStudio capable of covering the widest range of

    applications.

    Modern Imaging Applications Require the Most Advanced Software

    Platform - DynamicStudio Is the Solution

    DynamicStudio

    Rising bubble column visualization.

  • 8/12/2019 Dantec Dynamic

    4/8

    Fluid Dynamics

    Velocity and turbulence mapping, 2 or 3 velocity compo-

    nents by 2D Least Squares Matching (LSM), Particle Image

    Velocimetry (PIV), Time Resolved PIV (TR-PIV), VolumetricParticle Tracking Velocimetry (PT)V, Tomographic PTV

    and 3D LSM Fluid temperature or concentration measurements by

    Laser-Induced Fluorescence (LIF)

    Mixing Phenomena

    Liquid mixing by LIF

    Gas mixing by LIF

    Particle Diagnostics

    Particle size and velocity by Interferometric Particle

    Imaging (IPI), Shadow Sizing and PTV

    Sauter Mean Diameter mapping by LIF/Mie scattering

    Combustion Diagnostics

    Species concentrations (CO, NO, OH, CH, HCHO and others)

    by combustion LIF (C-LIF) Flame front visualization

    Soot concentration by Laser-Induced Incandescence (LII) Gas temperature by Rayleigh Scattering

    DynamicStudio Covers All Your Applications

    Results of a wake flow measured by stereo-scopic Particle Image Velocimetry.

    Visualization of a travelling ring vortex asa result of a time resolved volumetricparticle tracking experiment (Courtesy ofChristoph Brcker, TU Freiberg).

    Interference fringes that can be processed todroplet diameters using InterferometricParticle Imaging (IPI).

  • 8/12/2019 Dantec Dynamic

    5/8

    Stability Analysis and Detection of Coherent Structures

    Get more out of your scalar and vector data by stability

    analysis and uncovering of dynamically relevant spatial and

    temporal coherent structures using the most advanceddecomposition technique Oscillating Pattern

    Decomposition (OPD) Identification of coherent structures also from non time

    resolved data. Uncover the structures containing the most

    energy in your flow using Proper OrthogonalDecomposition (POD)

    Visualization

    New integrated Visualization module with advanced

    capabilities

    Create publishing quality 2D and 3D graphics and anima-tions from your measured data

    No need for expensive third party graphics programs No exporting and re-importing of data; all data is retained

    in DynamicStudio

    OH LIF image of the same gas burner flame as to the left.

    Spray droplets from an agricul-tural spray nozzle visualized byfluorescent background illumina-tion and Shadow Imaging(Courtesy of Lechler GmbH).

    OH* chemiluminescence from a slightly turbulent atmospheric flame ataround 309 nm with gate times 100 s, 1 ms and 10 ms respectively.

  • 8/12/2019 Dantec Dynamic

    6/8

    DynamicStudio Makes Complex Measurements Easy

    Diagram showing how to connect synchronization cables betweenthe auto-detected devices.

    User interface to the Acquisition Manager allowing control oftraverses and definition of complex automated measurements.

    Easy Set-up with Plug-and-Play

    Forget about setting up your system and typing complicated

    system parameters. DynamicStudio automatically recognizes

    devices plugged into a PC in the network, and configuresthem.

    Cable Connection Wizard

    The cable connection diagram guides you through thecabling of the system.

    Automated Measurements

    With the Acquisition Manager you can set up a series ofmeasurements each with different settings (e.g. traversing

    position, laser pulse separation or frame rate). This automati-

    cally controls attached devices such as cameras, lasers and

    traversing systems.

    Maximum Frame Rate with Distributed Acquisition

    Full frame rate on all cameras in multi-camera set-ups suchas stereo PIV or Volumetric Velocimetry, LIF or large area

    applications with image stitching Long measurement series - each PC has storage capacity for

    the camera connected to it Remote control - the image acquisition system can be in

    the lab and the control PC in a different room

    Scalable performance - number of cameras, or storagecapacity easily upgraded by adding PCs

    Different camera types can be combined

  • 8/12/2019 Dantec Dynamic

    7/8

    Instantaneous concentrationmap derived from Laser-Induced Fluorescence (LIF)measurements of a jet in crossflow.

    Even the most complex analysis sequences can be defined and applied to different ensembles andhanded over to Distributed Analysis using batch processing.

    Fast Data Access with Distributed Database

    Data can be stored on separate PCs in a network, yet

    accessed from one PC. The master database keeps track of

    the distribution of the data. State-of-the-art database toolsprovide these advantages:

    Capacity to store thousands of images as required for goodstatistics or long time series

    Simple and robust data management

    All set-up parameters are stored with each experiment Full documentation of hardware and data processing

    parameters

    Fast Results with Distributed Analysis

    The distributed architecture is very powerful for data

    analysis; the data is analyzed on the PC that has stored the

    data. This has several advantages: Reduction of data processing time by parallel computing

    Reduction of data transfer time

    Batch Processing for Automated Analysis

    Analyze vast amounts of data swiftly and consistently:

    Pre-define analysis sequences Re-use analysis sequences on new data sets

  • 8/12/2019 Dantec Dynamic

    8/8

    About Dantec Dynamics

    Worldwide representation

    Dantec Dynamics is the leading provider of laser optical measurement systems and sensors.

    Since 1947 we have provided solutions for customers to optimize their component testing

    and products. Our large number of customers benefit from our quality solutions within:

    From our six offices and more than 30 representatives worldwide we

    approach our customers individually. We examine the specific needs

    and find the best solution for you. For us you are a long-term partner

    in improving efficiency, safety and quality of life.

    A list of representatives is available at our website.

    DENMARK (headquarters)

    Dantec Dynamics A/S

    [email protected]

    FRANCE

    Dantec Dynamics S.A.S.

    [email protected]

    GERMANY

    Dantec Dynamics GmbH

    [email protected]

    JAPAN

    Dantec Dynamics K.K.

    [email protected]

    UNITED KINGDOM

    Dantec Dynamics Ltd.

    [email protected]

    USA

    Dantec Dynamics Inc.

    [email protected]

    www.dantecdynamics.com

    The specifications in this document are subject to change

    without notice.

    Dantec Dynamics is trademark of Dantec Dynamics A/S.

    Publication No.: 260_v4

    Fluid Mechanics

    Particle Characterization

    Combustion Diagnostics

    Thermal Comfort

    Microfluidics

    Paper Process Optimization

    Strain, Stress & Vibration

    Non-destructive Testing

    Disatac Tachometers