ater configuration failure

3
ATER CONFIGURATION FAILURE. 1 st step: alarma apare in FO CORE: MGW02 - ATER CONFIGURATION FAILURE. 2 nd step: detaliile necesare pentru investigatie in partea de RAN (vin de la FO CORE sau BO CORE) Please check BSC's Ater configuration (circuit type, pool, and codec) on BSC ZH9924 (SPC 11AE) for APCM 14545, 14662, 14822 14545 - 19 4043 13 6 16 28 EFR&DR&AMR&D144 14662 - 10 4074 19 4 16 28 EFR&DR&AMR&D144 14822 - 23 4137 22 6 16 28 EFR&DR&AMR&D144 14545 - CCSPCM=45 TSL=19 14662 - CCSPCM=2 TSL=10 14822 - CCSPCM=86 TSL=23 14545: MSC number = MSS01 14662: MSC number = MSS03 14822: MSC number = MSS02 3 rd step: te conectezi pe BSC-ul subliniat de Core cu MML (puty sau hit) 4 th step: printezi toate SPC-urile: NVI:NA0,:; FlexiBSC BSCZH9924 2013-05-08 15:46:18 SIGNALLING ROUTE STATES DESTINATION: SP RS ROUTES: NET SP CODE H/D NAME STATE SP CODE H/D STATE PRIO

Upload: ealfora

Post on 15-Dec-2015

216 views

Category:

Documents


4 download

DESCRIPTION

Nokia Flexi BSC

TRANSCRIPT

Page 1: Ater Configuration Failure

ATER CONFIGURATION FAILURE.

1st step: alarma apare in FO CORE: MGW02 - ATER CONFIGURATION FAILURE.

2nd step: detaliile necesare pentru investigatie in partea de RAN (vin de la FO CORE sau BO CORE)

Please check BSC's Ater configuration (circuit type, pool, and codec) on BSC ZH9924 (SPC 11AE) for APCM 14545, 14662, 14822

14545 - 19 4043 13 6 16 28 EFR&DR&AMR&D144

14662 - 10 4074 19 4 16 28 EFR&DR&AMR&D144

14822 - 23 4137 22 6 16 28 EFR&DR&AMR&D144

14545 - CCSPCM=45 TSL=1914662 - CCSPCM=2 TSL=1014822 - CCSPCM=86 TSL=23

14545: MSC number = MSS0114662: MSC number = MSS0314822: MSC number = MSS02

3rd step: te conectezi pe BSC-ul subliniat de Core cu MML (puty sau hit)

4th step: printezi toate SPC-urile:

NVI:NA0,:;

FlexiBSC BSCZH9924 2013-05-08 15:46:18

SIGNALLING ROUTE STATES

DESTINATION: SP RS ROUTES: NET SP CODE H/D NAME STATE SP CODE H/D STATE PRIO--- ------------------ ---------------- ----- ------------------ ------- ----NA0 088B/02187 MSS01 AV 088B/02187 AV-EX 7

NA0 088C/02188 MSS03 AV 088C/02188 AV-EX 7

NA0 108B/04235 MSS02 AV 108B/04235 AV-EX 7

NA0 11AE/04526 BZH24 - OWN SP AS SEP

COMMAND EXECUTED

Page 2: Ater Configuration Failure

5th step: printezi ETPCM-ul echivalent in BSC. Pentru asta ai nevoie de: a. SPC-ul MMSS-uluib. CCSPCMc. TSL

RCI:SEA=7:NET=NA0,SPC=088B,CCSPCM=45,TSL=19:;

FlexiBSC BSCZH9924 2013-05-08 15:59:36

CGR : 10 NCGR : MSS12V ETPCM-TCPCM-TSL : 75-2-19 ORD : 1370 CTRL : Y LSI : AINA0 HGR : 1-1370 STATE : WO-EX NET : NA0 SPC(H/D) : 088B/02187 CCSPCM : 45

COMMAND EXECUTED

6th step: printezi statusul si configuratia lui

USI:ET,75::;

EXECUTION STARTED

FlexiBSC BSCZH9924 2013-05-08 16:03:44

WORKING STATE OF UNITS UNIT PHYS STATE LOCATION INFO ET-75 WO-EX SET-0 BCSU-4 -

WGO:75:ALL:;

EXECUTION STARTED

ET_PCM 75 TC_PCM POOL TYPE ET_PCM_TSLS 1 28 AMR&EFR&DR&D144 1 && 8 2 28 AMR&EFR&DR&D144 9 && 16 3 28 AMR&EFR&DR&D144 17 && 24 4 28 AMR&EFR&DR&D144 25 && 31 THROUGH CONNECTIONS -

COMMAND EXECUTED