lifturi parcare
TRANSCRIPT
-
8/13/2019 lifturi parcare
1/5
CONFORMITY
Klaus Multiparking GmbHHermann-Krum-Strae 2D-88319 Aitrach
Phone +49-7565-508-0Fax +49-7565-508-88
E-Mail [email protected] www.multiparking.com
ge 1
ction
mensions
r data
ge 2
dthmesions
ge 3
proach
ad plan
tallation
ge 4
ctricaltallation
chnicalta
ge 5
be perfor-d by the
stomer
scription
Page 1 of 5
StackParkerG63
|Codenumber583.9
1.
490-004|
Version09.
2009
Product Data
Stack Parker
G63
Dimensions:
All space requirements are minimumfinished dimensions. Tolerances for spacerequirements . Dimensions in cm.
EB (single platform) = 3 vehiclesDB (double platform) = 6 vehicles
+30
145160
92
12595500 (520)
100
156
13
65
140
seetable
30160
95
125100500 (520)
105
15 613
seetable
Standard passenger car
Standard station wagon
Standard passenger cars are vehicleswithout any sports options such asspoilers, low-profile tyres etc.
Garage with door in front of thecar parking system
Notes
4580
Free space
Free space
520for vehicle up to 5.00m = 164 long
(540for vehicle up to 5.20m 17 long)
210
805
0
(DH)
Cuttingthrough
355
350
Height
(H)
1
3
Clearheight
Grounding
50
4
5
Delimitation
2% 2%
Drainage channelwith sump
50
Standard Type G63-350
Exklusive Type G63-370
375
370
Height(H)
Typ H DH**
G63-350* 510 165
540 175G63-370
480 155G63-330
Type H upper/middle/lower
car height
G63-350* 510
540G63-370
160
170
480G63-330 150
1.90 mwidth
max. 2000 kg ***weight
max. 500 kg ***wheel load
Suitable for:
Standard passenger car and station wagon.Height and length according to contur.
* = Standard Type
* = Standard Type ** = without car
For dividing walls: cutting through10x 10 cm (for pipes).
Dimensions A1, A2 and A3 must becoordinated with the door supplier.
If the total height is greater, the max.vehicle height for the upper parkingspace increases accordingly.
Potential equalization from foundationgrounding connection to system(provided by the customer).
In compliance with DIN EN 14010,10cm wide yellow-black markings
compliant to ISO 3864 must be appliedby the customer to the edge of the pitin the entry area to mark the dangerzone (see load plan page 3).
Load increase possible only for EBagainst surcharge.
1
2
3
4
5
6
Compact Type G63-330
335
330
Height(H)
Height(H)
50
A1 Free space forroller door
A3
80
2
2125
2
A2 2
3
2% 2%
Drainagechannelwith sump
6
*** = Special design: EB max. 2500 kg/wheel load max. 625kg
-
8/13/2019 lifturi parcare
2/5
Stack Parker G63 | Code number 583.91.490-004 | Version 09.2009
ge 1
ction
mensions
r data
ge 2
dthmesions
ge 3
proach
ad plan
tallation
ge 4
ctricaltallation
chnicalta
ge 5
be perfor-d by the
stomer
scription
Page 2 of 5
End parking spaces are generally more difficult to drive into. Therefore we recommended for end parking spaces our wider platforms.For the greatest possible ease-of-use, we recommend platform widths of 250 to 270 (EB) or 500 (DB).Parking on standard width platforms with larger vehicles may make getting into and out of the vehicle difficult. This depends on typeof vehicle, approach and above all on the individual drivers skill.
Please note:
Widths for garage with door in front of car parking system
Width for basement garage
Dividing walls
Columns in pit
Columns outside pit
Single platform (EB) Double platform (DB)
B1
EB
B1
DB
B1
EB DB
Carriageway in accordancewith local regulations
Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB) Example
usable platform width230
240250260270
*B1
460
470480490500
*B1 B1
230 + 460
240 + 470250 + 480250 + 500270 + 500
*usable platform width usable platform width
270
280290300310
500
510520530540
770
790810830850
Carriageway in accordancewith local regulations
Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB) Example
B2
EB EB
B3 min. 20
max.
140
max.
220
B2
DB DB
B3 min. 20
max.
140
max.
220
EB EB
B2
DB DB
B3 min. 20
max.
140
max.
220
460
470480490
*
500
B2 B3 B2 B3230 + 460
240 + 470250 + 480250 + 500270 + 500
*230240250260
*
270
B2 B3usable platform width usable platform width usable platform width490
500510520
480
490500510
760
780800820
530 520 840810830
750
770790
260
270280290
250
260270280
300 290
B4
EB EB
B5 min. 20 B4
DB DB
B5 min. 20 B4
DB DB
B5 min. 20
EB EB
Carriageway in accordancewith local regulations
Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB)
460
470480490500
*B4 B5 B5B4
230 + 460
240 + 470250 + 480250 + 500270 + 500
*230240250260270
*B4 B5usable platform width usable platform width usable platform width
490
500510520530
480
490500510520
760
780800820840
750
770790810830
260
270280290300
250
260270280290
DF
EB
A3
L LDF
DB
L LDF
EB
L SDF
S
EB
DF
DB
L SDF
S
DB
Carriageway in accordancewith local regulations
230
240250260270
*L S usable platform width
460
470480490500
*L Sdoor entrance width DF
A3 = seat-engaging
surface (dimensionsrequire coordinationwith door supplier.)
* = standard width (parking space width 2.30m)
Allround doordimensions requirecoordination betweendoor supplier andlocal agency ofKlaus Multiparking.
usable platform width door entrance width DF165
15202020
30
30404040
2375
250250260270
175
125
1520
25
35253040
475
475500500500
125
-
8/13/2019 lifturi parcare
3/5
Stack Parker G63 | Code number 583.91.490-004 | Version 09.2009
ge 1
ction
mensions
r data
ge 2
dthmesions
ge 3
proach
ad plan
tallation
ge 4
ctricaltallation
chnicalta
ge 5
be perfor-d by the
stomer
scription
Page 3 of 5
Approach
Load plan
Units are dowelled to the floor. Drilling depth: approx. 15 cm.Floor and walls below the drive-in level are to be made of concrete (quality minimum C20/25)!
216
520 (540)
Pitdepth
seepage1
Height
seepage1
82
250
225
265
B1
+25 +25
10 10
20+55
20+55
EB
10
+3.5+3.5
+12 +12
+15 +15Markings compliant to ISO 3864*
10B1
10
+35 +35
25+80
25+80
DB
+4+4
+12 +12
+20 +20
Forces in kN
* = Colors used in this illustration are not ISO 3864 compliant
Installation data
Free space for longitudinal and vertical ducts (e.g. ventilation)
10
B1
35103510351035
+50 B1
+2.5 0 B1 B1
+50
(505)(502.5)(272.5)(275)
+2.5 0
20 20
30
B2B3B2(260) 20 (750) 20 (490)
max.200
max.140
EB EB DB DB
Approach level
B1, B2, B3= (see table on page 2)
Free space for vertical pipelines,
ventilation branch canals
Free space for horizontalducting
Free space only applicable if vehicleis parked forwards = FRONT FIRSTand drivers door on the left side.
( ) = Dimensions in bracketsillustrate an example for usableplatform width 230/460cm.
Example for ventilation branchcanal and/or vertical pipelines.
The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will causeserious maneouvring & positioning problems on the parking system for which the local agency of Klausaccepts no responsibility.
maximumdescendingslope 4 %
maximumascendingslope 14 %
-
8/13/2019 lifturi parcare
4/5
Stack Parker G63 | Code number 583.91.490-004 | Version 09.2009
ge 1
ction
mensions
r data
ge 2
dthmesions
ge 3
proach
ad plan
tallation
ge 4
ctricaltallation
chnicalta
ge 5
be perfor-d by the
stomer
scription
Page 4 of 5
Technical data
Low-noise power units mounted to rubber-bonded-to metalmountings are installed. Nevertheless we recommend that parking
systems garage be built separately from the dwelling.
Units
wall recess plans maintenance offer/contract declaration of conformity test sheet on airborne and slid-borne sound
Available documents
Generally, this parking system is not suited for short-time parkers(temporary parkers). Please do not hesitate to contact your localKLAUS agency for further assistance.
Range of application
If the permissible drop opening is exceeded, railings are to bemounted on the systems. If there are traffic routes next to or behindthe installations, railings compliant to DIN EN ISO 13857 must beinstalled by the customer. Railings must also be in place duringconstruction.
Railings
Environmental conditions for the area of multiparking systems:Temperature range 10 to +40 C. Relative humidity 50 % at amaximum outside temperature of + 40 C.If lifting or lowering times are specified, they refer to an environmentaltemperature of +10 C and with the system set up directly next to thehydraulic unit. At lower temperatures or with longer hydraulic lines,these times increase.
Environmental conditions
See separate sheet regarding corrosion protection.
Corrosion protection
According to DIN 4109 (Sound insulation in buildings), para. 4,annotation 4, Klaus Multiparkers are part of the building services(garage systems).
Normal sound insulation:
DIN 4109, para. 4, Sound insulation against noises from buildingservices.
Table 4 in para. 4.1 contains the permissible sound level valuesemitted from building services for personal living and working areas.According to line 2 the maximum sound level in personal living andworking areas must not exceed 30 dB (A).Noises created by users are not subject to the requirements(see table 4, DIN 4109).
The following measures are to be taken to comply with this value:
Sound protection package according to offer/order(Klaus Multiparking GmbH)
Minimum sound insulation of building Rw = 57 dB(to be provided by customer)
Increased sound insulation (special agreement):
DIN 4109, Amendment 2, Information on planning and execution,
proposals for increased sound insulation.Agreement: Maximum sound level in personal living and workingareas 25 dB (A). Noises created by users are not subject to therequirements (see table 4, DIN 4109).
The following measures are to be taken to comply with this value:
Sound protection package according to offer/order(Klaus Multiparking GmbH)
Minimum sound insulation of building Rw = 62 dB(to be provided by customer)
Note: User noises are noises created by individual users in ourMultiparking systems. These can be noises from accessing theplatforms, slamming of vehicle doors, motor and brake noises.
Sound insulation
Electrical installation
Installation diagram Electrical data (to be performed by the customer)
to the nextsystem
1
2
3
4
11
10
9
7
12
14
6
Conduit EN 25 (M25)height: + 1.70m
Conduit EN 25 (M25)height: + 1.10m
5
13
8
180
120
0.00
Supply line 5 x 2.5 mm2
(3PH + N + PE) with marked wireand protective conductor
No. Qunatity Description Position Frequency
to main switch3 1per unit1
in the supplyline
Electricity meter1 1
in the supplyline
Main fuse: 3 x fuse 20A (slow)or circuit breaker 3 x 20A(trigger characteristic K or C)
2 1per unit1
Lockable main switch defined at theplan evaluation
4 1per unit1
Supply line 5 x 2.5 mm2
(3PH + N + PE) with marked wireand protective conductor
from mainswitch to unit
5 1per unit1
Foundation earth connector corner pitfloor
6 every10 m
Equipotential bonding in accordancewith DIN EN 60204 from foundationearth connector to the system
7 1persystem
1
Electrical data (included in delivery of Klaus Multiparking)
No. Description
Terminal box8
Control line 3 x 0.75 mm2(PH + N + PE)9
Control line 7 x 1.5 mm2with marked wire and protective conductor10
Operating device11
Control line 5 x 1.5 mm2
with marked wire and protective conductor12Hydraulic unit 5.2 kW, three-phase current, 400 V / 50 Hz13
Control line 5 x 1.5 mm2with marked wire and protective conductor14
-
8/13/2019 lifturi parcare
5/5
Stack Parker G63 | Code number 583.91.490-004 | Version 09.2009
ge 1
ction
mensions
r data
ge 2
dthmesions
ge 3
proach
ad plan
tallation
ge 4
ctricaltallation
chnicalta
ge 5
be perfor-d by the
stomer
scription
Page 5 of 5
Description Single platform (EB) and Double platform (DB)
We reserve the right to change this specification without further notice
Multiparking system providing independent parking spaces for3 cars (EB), 2 x 3cars (DB), one on top of the other each.
Dimensions are in accordance with the underlying dimensions ofparking pit, height and width
The parking bays are accessed horinzotally (installation deviation 1 %).
Vehicles are positioned on each parking space using wheel stops onthe right side (adjust according to operating instructions).
Operation via operating device with hold-to-run-device usingmaster keys.
The operating elements are usually mounted either in front of thecolumn or on the outside of the door frame
Operating instructions are attached to each operator's stand.
For garages with doors at the front of the parking system the specialdimensional requirements have to be taken into account.
General description
2 steel pillars with base elements (mounted on the floor) 2 sliding platforms (mounted to the steel pillars with
sliding bearings) 2 platforms 1 mechanic synchronization control system (to ensure synchronous
operation of the hydraulic cylinders while lowering and lifting theplatform)
2 hydraulic cylinders 2 rigid supports (connect the platforms) Welded hydraulic lines up to installed globe valve Dowels, screws, connecting elements, bolts, etc. The platforms and parking spaces are end-to-end accessible for
parking!
Multiparking system consisting of:
Platform base sections Adjustable wheel stops
Canted access plates Side members Central side member [only DB] Cross members Safety railings along the upper, middle and lower platform
(if required) Screws, nuts, washers, distance tubes, etc.
Platforms consisting of:
Hydraulic cylinder Solenoid valve Safety valve Hydraulic conduits Screwed joints High-pressure hoses Installation material
Hydraulic system consisting of:
Operating device (Emergency Stop, lock, 1 master key perparking space)
Terminal box at wall valve Reed contact
Electric system consisting of:
Hydraulic power unit (low-noise, installed onto a console with arubber-bonded-to-metal mounting)
Hydraulic oil reservoir Oil filling Internal geared wheel pump Pump holder Clutch 3-phase-AC-motor (5.2 kW, 230/400 V, 50 Hz) Contactor (with thermal overcurrent relay and control fuse) Test manometer Pressure relief valve Hydraulic hoses (which reduce noise transmission onto the
hydraulic pipe
Hydraulic unit consisting of:
The Klaus company reserves the right in the course of technical progress to use newer or other technologies, systems, processes, proceduresor standards in the fulfillment of their obligations other than those originally offered provided the customer derives no disadvantage fromtheir so doing.
To be performed by the customer
7
15
= == =
20
9 9
9
Operating device exposed Operating device concealed
110abovecarriagewaylevel
120abovecarriagewaylevel
Conduit EN25 (M25)
Any constraints that may be necessary according to DIN EN ISO 13857in order to provide protection for the park pits for pathways directly infront, next to or behind the unit. This is also valid during construction.Railings for the system are included in the series delivery whennecessary.
Safety fences
Consecutive numbering of parking spaces.
Numbering of parking spaces
Lighting, ventilation, fire extinguishing and fire alarm systems.
Building services
Any necessary wall cuttings according to page 1.
Wall cuttings
For the front area of the pit we recommend a drainage channel,which you connect to a floor drain system or sump (50 x 50 x 20 cm).The drainage channel may be inclined to the side, however not thepit floor itself (longitudinal incline is available). For reasons ofenvironmental protection we recommend to paint the pit floor, andto provide oil and petrol separators in the connections to the publicsewage network.
Drainage
If due to structural conditions strip footings must be effected, thecustomer shall provide an accessible platform reaching to the topof the said strip footings to enable and facilitate themounting work.
Strip footings
According to DIN EN 14 010, a warning that identifies this dangerarea must be placed in the entrance area that conforms to ISO 3864.This must be done according to EN 92/58/EWG for systems witha pit (platforms within the pit) 10 cm from the edge of the pit.
Marking
Suitable electrical supply to the main switch and the control wire linemust be provided by the customer during installation. The functionalitycan be monitored on site by our fitters together with the electrician.If this cannot be done during installation for some reason for which thecustomer is responsible, the customer must commission an electricianat their own expense and risk.
In accordance with DIN EN 60204 (Safety of Machinery. Electrical
Equipment), grounding of the steel structure is necessary, providedby the customer (distance between grounding max. 10 m).
Electrical supply to the main switch / Foundation earth connector
Mounting of contactor and terminal box to the wall valve, completewiring of all elements in accordance with the circuit diagram
Costs for final technical approval by an authorized body Main switch Control line from main switch to hydraulic unit
If the following are not included in the quotation, they will alsohave to be provided / paid for by the customer:
Cable conduits and recesses for operating device (for double wingdoors: please contact the local agency of Klaus Multiparking).
Operating device