TECHNICAL SPECIFICATION
SPECIAL VEHICLE FOR EXTRICATION OF HEAVY CAPACITY AND QUALIFIED
FIRST AID
1. DESTINATION
The vehicle is designed for extrication and rescue assistance in case of various types of
accidents - traffic (car and train), technological disasters, in order to free those caught and trained
and to administer first aid at the place where the accidents are produced.
2. APPROVALS
2.1. The vehicle prototype, fully equipped, will go through a verification program prepared by
specialists of the General Inspectorate for Emergency Situations and those of the supplier, before
the first delivery, in order to determine whether the truck (including the features mentioned
above) fall in the performance of Technical and tactical specifications of this.
2.2. Truck will be approved at Romanian Auto Registry and will comply with provisions ofGovernment Ordinance no. 43/1997 regarding the roads as amended and supplemented;
2.3.The manufacturer of the vehicle or his authorized representative, will present a CE
declaration of conformity issued for the vehicle under the provisions GD nr.1029/2008
establishing the conditions for introductions on the market of the cars. The vehicle will also bear
the CE mark.
3. QUALITY ASSURANCE
3.1. The bidder will submit a document / documents issued by specialized organizations in the
field (notice) stating that the manufacturer / producers of the vehicle, the chassis (if different
from manufacturer of the vehicle) have implemented quality management systems according to
SR EN ISO 9001 / 2001 or equivalent.
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
2/45
4. GENERAL ORGANIZATION,COMPOSITION
4.1. Extrication and rescue vehicle for heavy capacity must be built on a chassis equippedwith a low-pollution engine and where is mounted a compartment capable of transporting
machinery, equipment, tools, accessories and other equipment needed for these specialized
types of interventions.
4.2. The cab of the vehicle will ensure the safe transportation of crew and equipment
protection;
4.3. The cabin will be equipped with means of opto-acoustic warning and communication;
4.4. Acoustic and optical warning light of the vehicle will be to enable highlighting of the
vehicle both during movement and at the operative site;
4.5. Superstructure made of aluminum alloy, aluminum alloy frame with removable fasteners
of the same material, covered with aluminum alloy sheet applied by adhesion.
4.6. The sides are closed with aluminum shutters, fitted with shelves (to ensure future
relocation possibility, in service at different levels of the shelves depending on the specific
equip), drawers, mounting brackets and in the cabin of the crew.4.7. The compartment will be equipped with supplementary lighting installation that will
allow normal visibility conditions both inside and in close proximity to the vehicle.
5. TECHNICAL SPECIFICATIONS
5.1. Special Vehicle:
5.1.1. Dimension: under O.G. 43/1997 regarding the roads, amended and supplemented;
5.1.2. Maximum operational weight: maxim 14.000 kg.;
5.1.3. Wheel drive 4 x 4
5.1.4. Temperature range that can be used between 290i 400C;
5.1.5. Noise level: as required by R.A.R.
5.2. Chasis: according to technical requirements
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
3/45
5.2.1. Vehicle category N2 sau N3
5.2.2. Engine:
- type: diesel;
- minimum output power provide minim 20 CP/t;
5.2.3. Accepted level of pollution: according to regulations U.E. effect on the date of
deliver
5.2.4. Cabin: double with 4 doors , folding with 1+5 seets
5.2.4.1. The cabin will be equipped with two air-breathing devices mounted on supports
that allow rapid equipment of the operators, according to annex. 9..
5.2.4.2. All seats will be fitted with seat belts as required by law.
5.2.5. Brakes: servo with ABS;
5.2.6. Direction: servo
5.2.7. Suspension: according to the category
5.3. The compartment for materials transport will have spaces for the following
categories of technical means:
5.3.1. Extrication set: annex 1;
5.3.2. . Pneumatic equipment: annex 2
5.3.3. Electical equipment: annex 3;;
5.3.4. Stabilization and passive fixation: annex 4;
5.3.5. Tools and protection: annex 5;
5.3.6. Medical equipment: annex 6
5.4. Command and communications between crew members:
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
4/45
5.4.1. Station dispatch or other mobile communications: technical characteristics listed in
Annex No. 7;
5.4.2. Terminale TETRA portabile de comunicaii pentru fiecare membru al echipajului
(6 complete).
5.4.2. TETRA portable communications terminals for each crew member (6 complete).
5.4.3. Specifications of 5.4.7. : annex 10
5.4.4. Portable communications: should not interfere with other electronic equipment;
5.5. Supplementary lighting installation:
5.5.1. Projector Lighting:1 buc. (attached to the cab, removable);
5.5.2. Lighting equipment installed in all compartments;
5.5.3. Projectors (lamps) to illuminate the area in the immediate vicinity of vehicle: 1-2
on each side and one at the back;
5.6. Acoustic and optical warning installation:
5.6.1. Two rotating blue color beacons with protection system on the cab or ramp signal
and one on the back of the supplies compartment .
Acoustic - optical signal ramp or two blue rotating beacons on the cab fitted / equipped with
protection against accidental bumps and acoustic warning device, or embedded within the cabin.
5.6.2. Installation of acoustic warning;
5.6.3. Acoustic signaling device for reversing;
5.6.4. Optical signaling system type "flash" in color red, mounted to the front of the cabin
6. PERSONAL PROTECTION EQUIPMENT
6.1. Protection equipment list annex
6.2. Technical specification of respiratory protective equipment - annex 9
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
5/45
7. PAINTING AND MARKINGS
Vehicle will be marked on the sides and front with the words "firefighter. Also on the truck side
will be imprinted with the logo "112". Font size will be chosen in proportion to the space
available. Writing reflective color will be white - fluorescent.
Vehicle color will be RAL-3000. Vehicles will be equipped with reflective strips and plates as
RAR, after consultation with the Contracting Authority.
NOTE: Annexes 1 to 10 form an integral part of this technical specification.
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
6/45
Annex no. 1
EXTRICATION SET
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
1. Hydraulic power unit 1 Engine: 4 stroke internal combustion
Weight : max. 30 kg
Couple: 2 for 2 tools simultaneously
operating
Oil and gas level indicators
The possibility of coupling /decoupling of
rapid hoses with working pump
The engine and pump casing protected with
carrying handle Low level of noise
2.Hydraulic power unit
1 Engine: 4 stroke internal combustion
Weight : max. 30 kg
Couple: 1 for 1 tool
The possibility of coupling /decoupling of
rapid hoses with working pump
The engine and pump casing protected with
carrying handle
Low level of noise
3.Hydraulic power unit
and stabilization set
of unstable
structures
3 Weight: max. 15 kg
Couple: 1 for 1 tool
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
7/45
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
4.Spreader
1 Spreading force at 25 mm of: min. 60 kN
(cf. EN 13204)
spreading distance: min. 800 mm
spreading force at the edge of jaws: min.
200 kN
Pulling force: min. 100 kN Weight: max. 25 kg
5.Spreader accesories
set
1 2spare heads, 2 cutting heads, 2 pulling
heads, all in a carrying case
2 pulling chains with hook of 3m and 1,5 m,
both in a carrying case
6.Cutter
1 Cutting force: min. 900 kN
Cutting roand bar: min. 40 mm diameter
Blades opening at edge : min.150 mm
Weight . 20 kg
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
8/45
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
7. Combi tool 1 Cutting force: min. 350 kN
Cutting roand bar: min. 30 mm
Spreading force at 25 mm of edge: min. 30
kN (cf. EN 13204)
Spreading force: min. 100 kN
Spreading distance : min 350 mm Pulling force: min. 40 kN
Weighr : max. 15 kg
8. Accesories for the
combi tool
1 2 pulling heads and 2 pulling chains of 3 m
and 1,5 m, all in a carrying case
9. Short rescue cylinder 2 pulling force over full stroke: min. 100 kN
Extended length: min. 600 mm (can work
in tandem with medium rescue cylinder) Retracted length : max. 450 mm
Weight : max. 12 kg
3 extension pipes with a length of min. 100,
200 and 500 mm
10. Medium rescue
cylinder
2 pulling force over full stroke : min. 130 kN
Extended length: min. 900 mm (can work
in tandem with long rescue cylinder)
Retracted length: max. 600 mm
Pulling force: min. 45 kN
Weigth: max. 15 kg
Command sleeve with automatic update to
the neutral position when it is left open
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
9/45
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
11. Long rescue cylinder 2 pulling force over full stroke: min. 130 kN
Extended length: min. 1600 mm
Retracted length: max. 950 mm
Pulling force: min. 45 kN
Weigth: max. 21 kg
12. Accesories formedium and long
rescue cylinders
1
Adaptation set for lifting heavy vehicle intransport box
1 coupling flange, 2 cross head, 1 chisel
head, 1 cone head, 2 flate heads, 2 pulling
heads, all in a transport box
13. Corner support 2 Support for the positioning of hydraulic
cylinder to the B pillar of the car
Min. 3 support points
Weight: max: 10 kg
14. Mini cutter / foot
lever cutter
1 Cutting force: min. 75 kN
Jaws opening: min. 40 mm
Hose: min. 30 cm
Weigth max: 54 kg
Transport box
15.
Feather lifting-screw
opening where it can be introduced: min. 6
mm
Splitting race: min. 45 mm
Splitting force: min. 230 kN
Weigth : max. 10 kG
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
10/45
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
16.Console lifting screw
1 Lifting force at the end: min. 100 kN
Lifting force on console: min. 90 kN
Height with the retracted plunger: max. 450
mm
Plunger race: min. 240 mm
opening where it can be introduced: min. 60mm
Weight : max. 25 kg
17.Small lifting screw
2 Lifting force: min. 500 kN
Height with the retracted plunger: 190 mm
Plunger race: min. 100 mm
Weight : max. 10 kG
18.Door opener
1 Race: min 120 mm
Pushing force: min. 90 kN
19. Cutter for steel bars 1 Cutting force: min. 130 kN
Blades opening: min. 25 mm
Depth of cut: min. 25 mm
Weight : max. 10 kG
20. Cutter for steel
cables
1 Cutting force: min. 250 kN
Jaws opening : min. 30 mm
Diameter of steel wire cable: min. 19 mm
Diameter of steel single wire cable: 19
Weight max. 12 kG
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
11/45
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
21. Cutter for electric
cables
Cutting force: min. 90 kN
Jaws opening: min. 100 mm
Diameter of electric cable:min. 70 mm
Diameter of telephone cable: min. 90 mm
Weight: max. 15 kG
22. Pipe squeezer
Squeezing force: min. 145 kN Pipe diameter: min. 55 mm
wall thickness pipe: min. 3,5 mm
Weight: max. 9 kG
23. Short hoses system
for coupling the tools
on position: 6, 8, 9,
11 13, 17 si 21
3 Made of lightweight and highly resistant
material
Lenght: min. 5 m different colors
couplings to be self-locking
The possibility of coupling/decoupling
quick with pump/tool, with the pump running
without closing the oil flow
Do not allow decoupling, if oil is at the
maximum working pressure
The possibility of unlimited rotation
between the tool and pump
Equipped with a anti bending sleeve at both
ends
Weight: max. 2,5 kg
Safety report: min. 4:1 (cf. EN 13204 norm)
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
12/45
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
24. Long hoses system
for coupling the tools
on position. 6, 8, 9, 11
13, 17 si 21
3 Made of lightweight and highly resistant
material
Lenght min: 10 m different colors
couplings to be self-locking
The possibility of coupling/decoupling
quick with pump/tool, with the pump runningwithout closing the oil flow
The possibility of unlimited rotation
between the tool and pump
Equipped with a anti bending sleeve at both
ends
Weight max. 5 kg
Safety report: min. 4:1 (cf. EN 13204 norm)
25. Hose reels system for
coupling the tools on
position: 6, 8, 9, 11
13, 17 si 21
1 The length of the hose system: min. 2x15 m
Weight: max. 35 kG
26.
Hose for coupling the
tools on position: 16,18 - 20, 22 24
2 Lenght: min. 3 m
Weight: max. 2 kG
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
13/45
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
27.
Independent
electrical cutter with
accesories
1 Cutting depth: min. 140 mm
Cutting force: min 250 kN
Battery voltage: 24 V
Accesories: 3Ah backup battery, 220V
charger,harness for transport, storage transport
box, support for the battery for the belt, electriccable of min.5m for power supply from an
external power source
Weight : max. 20 kG
28.
Electric combi tool
with accesories
1 Spreading force: min. 250 mm
Spreading force at the base of the blades:
min. 150 kN
Spreading force at 25 mm from edge: min.
25 kN (cf. EN 13204)
Cutting depth: min. 190 mm
Cutting force: min 240 kN
Battery voltage: 24 V
Accesories: 3Ah backup battery, 220V
charger,harness for transport, storage transport
box, support for the battery for the belt, electric
cable of min.5m for power supply from an
external power source
Round bar cutting diameter. de min. 24mm
Weight: max. 18 kG
29.
Independent manual
cutter
1 Cutting depth: min. 140 mm
Cutting force: min 250 kN
Weight : max. 12 kG
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
14/45
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
30.
Independent manual
combi tool
1 Spreading distance: min. 250 mm
Spreading force at the base of the blades:
min. 130 kN
Spreading force at 25 mm from edge: min.
20 kN (cf. EN 13204)
Cutting depth: min. 190 mm Cutting force: min 200 kN
Round bar cutting diameter. 24mm
Weight: max. 12 kG
31.
Stabilization set
(support struts)
1 2 hydraulic cylinder with locking sleeve,
minimum length ( with retracted plunger) of
1000 mm, plunger stroke min.250 mm, pushing
force min.95 kN
Extend elements: 2 of 125 mm, 4 of 250
mm, 4 of 500 mm, 2 of 1.000 mm
Coupling elements : 2
Accesories: 4 bottom flanges,4 spherical
flanges, 4 spherical heads, 2 V2 heads, 2 cross
heads, 2 beam supports, 2 suppoert plates, 4
ropes with rifle, 2 bags for storage / transport of
accesories, 2 bags for storage / transport for
extension elements
32.
Steel wire puller
1 cpl. Lifting force: min. 25 kN
Pulling force: min. 55 kN
Weight: max 30 kg
Includes at least 20m of steel cable with
hook
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
15/45
Annex no. 2
PNEUMATIC EQUIPMENT
Nr.
crt.
NAME QUANTITY TECHNICAL SPECIFICATIONS
0 1 2 3
1.Lifting bags set
hight pressure
1
2 lifting bags min 100 kN i h >200 mm;
2 lifting bags min 200 kN i h >250 mm;
2 lifting bags min 300 kN i h >300 mm;
2 lifting bags min 400 kN i h >400 mm;
The bags must be reinforced with aramid
inssertion, not black color, must have
reflecting labels
Dual Control Unit;
Pressure decelerator;
2 hoses of 10 m color coded;
2 hoses of 5 m color coded;
2 closing hoses;
Tank (cylinder) of compressed air - 6 l/
300 bars
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
16/45
2.Lifting bags set
reduced pressure(with repair kit)
1 2 lifting bags de min. 55 kN;
Lifting height min. 600 mm
Storage bag;
Dual Control Unit;
Pressure decelerator
2 hoses of 5 m;
Tank (cylinder) of compressed air - 6 l/
300 bar.
3.Stopper set for
obturate the leaking
pipes and tubes
1 With the possibility of inflate until
diameter of: 200, 400 i 600 mm; Pressure decelerator with hose
connectionmin. 2 m.;
Control unit with safety valve
3 closing hoses
Tank (cylinder) of compressed air 6
l/300 bar.
4.Obturating system
for the leaks of the
cistern
1 cpl. Minimum sealling surface 450x450 mm
two fastening straps at least 10 m in length
with catch
attachment ham
Hose with safety valve
Temperature -300i +700C
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
17/45
Annex no.3
ECHIPAMENTE ELECTRICE
Nr.
crt.
DENUMIRE CANTI
TATE
CARACTERISTICI TEHNICE
0 1 2 3
1. Transportable
Motogenerator
1 cpl. Power: 5 6 kW;
Pressure : 220-230 V;
Control Panel / distribution:
- measuring and control devices;
- Means of command and operational control
- Monophase suckets: 4 buc.
The fixing of the components will be equipped
with carrying handles and holders for
placement on the ground.2. Halogen Projectors 4 buc. P = 1000 W
Coupling system in rack and mast
3. Choke cable for
projector
4 cpl. L cable : min. 25 m.;
P lamp : 1000 W
4. Rack 4 buc. H = minim 1,5 m
With lamp coupling system
5. Pneumatic telescopic
mast *
1cpl. H = minim 3,5 m (Ground level)
Manual pump;
Discharge valve
Note: * Pneumatic telescopic mast will be able to mount on the truck
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
18/45
Annex no.4
PASSIVE STABILIZATION SET
Nr.
crt.
NAME QUANT
ITY
TECHNICAL SPECIFICATIONS
0 1 2 3
1. Stabilization block
set
1 Formed from at least 2 blocks with stairs
and 4 angle blocks
Material: polyethylene
Admissive pressure area: 100 kg/cm
Anti-slip material and resistant to breakage
2. Stabilization block
set
1 Formed from at least. 6 fixing blocks i 4
angle blocks
Material: polyethylene
Admissive pressure area: 100 kg/cm Anti-slip material and resistant to breakage
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
19/45
Annex no.5
TOOLS AND OTHER MEANS OF PROTECTION
Nr.
crt.
NAME QUANT
ITY
TECHNICAL SPECIFICATIONS
0 1 2 3
1.
Manual glass cutter
2 Includes glass breaker
Includes spare blades
Weight: max 2 kg
2.Airbag protection
2 For wheel
The front does not contain steel
components
Easy to install
Storage bag
3. Protection covers for
the tools
1
Made of PVC ,polyester lined Easy to wash, water proof
Dimensions: cca. 200 x 150 cm
4.Easy protection
covers
1 Water proof
9 with magnets for easy attachment of
metal parts
6 with Velcro for pillar protection
5.Protection shield
2 Made of transparent PVC
Dimensions : cca. 90 x 50 mm
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
20/45
Annex no.6
List of qualified first-aid medical equipment
No Name PcsNo.
pcs
1 Emergency /first aid suitcase include the following: Pcs 1
a. Artificial ventilation ballon for adults / children:
- With the ability to connect to oxygen;
- With oxygen reservoir and pressure valve (1 cpl.);
-
With face masks with at least 2 different sizes for adults and 2different sizes for children (1+1 sets)
Cpl. 1
b. Guedell pipes (sizes 1,2,3, i 4). Set/buc.
c. Portable oxygen tanks ( 5l) with reducer mounted for administering
the oxygen by maskCpl. 1
d. Electrical aspirator for secretions with 20 different sizes:
- Rechargeable battery to 220 V c.a. and to 12 V c.c.
- Container for collecting the secretions of min 500 ml
- Wall support with the possibility of charging
Cpl 1
e. Oxygen masks for children Set 1
f. Oxygen masks for adults Set 1
g. Bandages / dressings Set 1
h. Special burn dressings of various sizes , coated with gel for cooling
(Aquagel).Set 1
2 Suitcase with immobilization materials include the following: Buc 1
a. Adjustable cervical collars. Set/buc. 1/3
b. Non-adjustable cervical collar (pediatric, adult without neck, adult
short neck, throat adult medium adult long neck)Set/buc. 1/5
c. Vacuum splints for upper member (2 buc)
d. Vacuum splints for inferior member (2 buc)
e. Vacuum splints for lower leg and femur (2 buc)
Set 1
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
21/45
f. Manual vacuum pump Buc. 1
3 Semi-automatic defibrillator to the following minimum specifications: Cpl.. 1
a. Base configuration without EKG monitoring
b. Rechargeable battery to 220 V c.a. and to 12 V c.c. Buc. 1
c. Verbal commands in Romanian
d. Wall support with the possibility of charging Buc. 1
e. Protection cover Buc. 1
f. Disposable defibrillation electrodes / defibrillator with a duration of at
least 2 years
Set 20
4 Folding shovel stretcher with fixing system for cephalic extremity Buc. 15 Immobiliser for extrication KED type Buc. 1
6 Aquagel soaked blanket in the original container storage (with a
minimum shelf life of three years), adult
Buc. 1
7 Adult blankets (in soft washable cover) Buc. 2
* Suitcases are made of soft, washable material
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
22/45
Annex no.7
Technical Specification TETRA terminals installed in vehicles
1. Considerations
1.1. TETRA Terminals will be working on TETRA MOTOROLA (Dimetra IP ver. 6.1) and
TETRA EADS infrastructures. In consequence, TETRA terminals:
a. Have to be certified by ISCOM for TETRA MOTOROLA Infrastructure (DIMETRA IP
6.0 or following versions). For each Terminal type the Bidder should be providing first
page the Certificate issued by ISCOM and specify the web link of the ISCOM certificate
on TETRA MoU website.
b. Have to be certified by ISCOM for EADS TETRA infrastructure(NTS 4.5 or followinf
versions). For each type of Terminal, the Bidder should be providing first page the
Certificate issued by ISCOM and specify the web link of the ISCOM certificate on
TETRA MoU website.
c.
Have to be certified by Dimetra IP infrastructure operator implemented in Romania
(S.T.S.). The Procedure is published on S.T.S. website, URL:
www.stsnet.ro/documente/Procedura TETRA.pdf). The winning Bidder (Seller) has to
provide the S.T.S issued certificate before signing the contract. FAILURE TO
PROVIDE THE CERTIFICATE IN DUE TIME OR PROVIDNG A CERTIFICATE
THAT CERTIFIES MISSING SERVICES/FUNCTIONALITY WILL ATTRACT
DISQUALIFICATION OF THE BIDDER
d. Has to support multiple networks (MNC/MCC) based on Terminal programmed list.
2. Technical Requirements
2.1. Standardization
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
23/45
- TETRA terminals provided must comply with ETSI TETRA standards, as
follows:
- 300 392 TETRA V+D air interface;
- 300 394 TETRA V+D conformance testing;
- 300 395 TETRA Speech Codec;
-300 396 TETRADMO.
- TETRA terminals offer will be certified pet. l.a., l.b., 1.c.
2.2. Environment
TETRA terminals provided must have the following environmental characteristics:
- Operating temperature: -20 ..... +55 C
- Storage temperature: -30..+60 C
- Humidity: ETSIETS 300 019
-
Shock and vibration: ETSI ETS 300 019- Dust and water protection: IP 54
2.3. Configuratie
Mobile terminal configuration will be "split" (Panel remote + radio unit).
2.4. RF
TETRA terminals provided must have the following features RF:
a. RF band (TMO&DMO): 380-385 MHz - 390-395 MHz
b. Duplex spacing: 10 MHz
c. Adjacent channel spacing: 25 KHz
d. Static Sensitivity: -112 dBm
e. Dynamic sensitivity: -103 dBm
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
24/45
f. Receiver Class A
g. Terminal Tx Power 3 W
2.5. TETRA services and
functionalities
Voice Services
a. group call (GC) in TMO & DMO (TMO least 100 pre-programmed groups, minimum 50
BMD groups pre-programmed)
b. Emergency Call;
c. Individual Call (IC);
d. Phone call /w// duplex (PABX/PSTN).
Additional Services
a. TPI;
b. CLIP;
c. DGNA;
d.Late entry;
e. Priority Call;
f. Scan groups (at least 3 groups to scan)
g.Ambience Listening.
Data Services
a. SDS/SDS-TL;
b. Status Messages
c. IP PDS;
d. PEI interface for external DTE connection that supports RS232
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
25/45
2.6. Mobility
a. Reselect cell: type 3 or higher
b. support for multiple networks (MNC) from a list of scheduled terminal.
2.7. Security
a. Login. Authentication key must be provided in a format as
TETRA MoU recommendations. Authentication key must be provided respecting the
security rules established by the TETRA MoU SFPG recommendations.
b. Radio interface encryption (algorithms supported: TEA1 and TEA2 ). Terminals shall be
provided with TEA2 algorithm.
c. Safety Class: Class 1, Class 2 and Class 3.
d. Disable / Enable terminal (Remote disable/enable)
e. E2EE supported by upgrading software / hardware.
2.8. Other features.
Tx inhibit
2.8.User Interface
2.9.(MMI) Display
-alphanumeric display with minimum 4x12 character
-Indicators for display on display modes (de ex: TMO, DMO, Tx inhibit, etc)
-Operating intuitive menus;
Keyboard
-Alphanumeric keyboard;
-menu navigation keys;
-button / key for emergency call initiation;
-button / key to select group;
-button / key for volume;
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
26/45
Phonebook
-Phonebook (Capacity: minimum 70);
-
Easy Call (eg by looking in the phone book, last dialed numbers, etc.)
-Possibility to use audio devices;
Multi-purpose interface for programming / data.
3. Integrated GPS Receiver
3.1. TETRA mobile terminal must be equipped with integrated GPS receiver.
3.2. TETRA mobile handset must support LIP ETSI (TS 100 392-18).
3.3. TETRA mobile handset must support transmission of location information
simultaneously (in terms of the user) to use TETRA Packet Data service.
3.4. Specifications for GPS receiver:
Integrated GPS receiver must meet the following specifications:
- satellites simultaneously receive packets: minim 10
- sensitivity: minim-152 dBm
-
Precision: max 5 m (probabilitate 50%)
max 10 m (probabilitate 95%)
4. Accessories and installation
For each terminal seller must provide accessories and installation. These should include:
- Standard Microphone with PTT and mounting bracket;
- speaker connection cable and mounting bracket;
-Power cable provided with safe and connected properly (min. 5m adapted to practical
situations);
-Data cable (for connection to a DTE)
-suport de fixare in autovehicul pentru unitatea radio si panoul de comanda;
-interconnection cable radio unit - control unit;
- omnidirectional car antenna, 380 ... 400 MHz band, VSWR
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
27/45
-converter from 24Vcc to 12Vcc (if the voltage available on vehicles requires);
-Active GPS antenna (are acceptable solutions including integrated GPS antenna on the same
UHF antenna support) band 1,5... 1,6GHz, VSWR
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
28/45
Abbreviations
AL - Ambience Listening
ARL - Automatic Resource Location
AVL - Automatic Vehicle Location
CLIP - Calling Line Identification Presentation
DGNA - Dynamic Group Number Assignment
DMO - Direct Mode Operation
DTE - Data Terminal Equipment
ETSI - European Telecommunications Standards Institute
GC - Group Call
GPS - Global Positioning System
IC - Individual Call
IP - Internet Protocol
ISCOM - Istituto Superiore delle Comunicazioni e delle Tecnologie deirinformazione
(laboratorul Ministerului Italian al Communicatiilor)
LIP - Location Information Protocol
MCC - Mobile Country Code
MIRA - Ministerul Internelor si Reformei Administrative
MNC - Mobile Network Code
MoU - Memorandum of Understanding
PABX - Private Automatic Branch eXchange
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
29/45
PC - Personal Computer
PDS - Packet Data Services
PEI - Peripheral Equipment Interface
PIN - Personal Identification Number
PTT - Push To Talk
PSTN - Public Switched Telephone Network
PSU - Power Supply Unit
RF - Radio Frequency
Rx - Receive
SDS - Short Data Services
SFPG - Security and Fraud Prevention Group
ST -Specificatie Tehnica
SwMI - Switching and Management Infrastructure
TEA - Tetra Encryption Algorithm
TETRA - Terrestrial Trunked Radio
TL - Transport Layer
TMO -Trunk Mode Operation
TPI - Talking Party Identification
Tx - Transmit
URL - Uniform Resource Locator
V+D - Voice + Data
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
30/45
VSWR - Voltage Standing Wave Ratio
WAP - Wireless Application Protocol
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
31/45
Annex no. 8
LISTWITH PERSONAL PROTECTIVE EQUIPMENT
1 Compressed air breathing apparatus with positive pressure (a cylinder)
with a maximum weight of 14 kg (according to EN 137), according to the
Annex. 9
Cpl. 6
2 Compressed air cylinder made of composite material composed of:
- 6,8 l cylinder at working pressure of 300 bar,with maximum weight
unladen of 4,5 Kg;- valve with fillet
Cpl. 6 *
3 PSI helmet with viewfinder (max. Weight 1,5 kg) to allow both the use of
masks from the breathing apparatus and the masks for smoke protection
according to SR EN 443.
Buc. 6
4 Short rubber soled boots with metal inlay according SR EN ISO 20344. Per. 6
5 PSI safety belt with hook according to STAS 5920-89 i STAS 3273-88 Buc. 6
6 Fire protection suit according to SR EN 469+A1+AC, class 2, composed
of:
- Jacket engraved on the back Firefighter, from reflective tape;
- pants
Cpl. 6
7 Protective gloves according to SR EN 659+A1 Per. 6
8 Leather gloves according to SR EN 659+A1 Per. 6
9 Leather boots with reinforced sole and metallic toecap according to SR
EN ISO 20345
Per. 6
10 Anti-caloric protective suit for temperatures up to 2500 C and
temperatures above 2500 C according to SR EN 1486Cpl. 1+1
* NOT: 6 cylinders of compressed air will have racks on the vehicle
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
32/45
Annex no.9
TECHNICAL SPECIFICATION
COMPRESSED AIR
BREATHING DEVICES
1. NAME
Compressed air breathing devices
2.PURPOSE
Insulating breathing apparatus, with compressed air is purposed for intervetion personell
protection during the missions taking place in areas with vitiated atmosphere by the presence of
toxic substances or below normal oxygen concentration.
3. CERTIFICATION, APPROVAL
3.1. The products vill bear CE mark of conformity and will and will be accompanied by SR EN
137 certificate of conformity and by declaration of conformity on oath. Certification has to be
obtained for the product having the requested configuration by the prezent technical
specification.
3.2. Before the first delivery the apparatus is due to go through a verification programme of
technico-tactical performance checking, approved by General Inspectorate of I.G.S.U.. Are
allowed onle the devices matching the technical-tactical performances specifications mentionedabove, after going through verification process earlier mentioned.
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
33/45
4. GENERAL ORGANIZATION
4.1. Compressed air tank from a cylinder, with a nominal capacity of 6.8 liters, tap screwconnection, made according to SR EN 144-2:2003 (stored compressed air at a pressure of 300
bar) made of composite materials;
4.2. Pressure reducer, which connects the cylinder valve, which has a pressure valve can be
adjusted and checked and is provided with separate outputs for these:
4.2.1. Hose assembly with pressure gauge and whistle. Gauge must be calibrated from 0 to 350
bar minimum value, allowing the wearer to read exactly 10 bar, have luminescent dial
(fosforcent) is protected with protective sleeve to shock, and the limit of safety (pressure trigger
audible warning signal) must be marked separately (red staining). Audible warning device
(whistle) must be activated to achieve safety and pressure to be placed near the gauge.
4.2.2. Medium pressure hose for connection to the valve on request. Hose must be equipped with
quick coupling system (mother hose coupling portion coming from the gearbox and coupling
father on the section of hose that leads to the demand valve) pressure bulkhead and allowing the
coupling / decoupling under pressure (hose length must allow the optimum use of the device)
4.2.3. Medium pressure hose (similar with 4.2.2.), for contact with other consumer, equipped
only with a mother tight coupling pressure and allowing the coupling / decoupling under
pressure.
4.3. If the gear due to the constructive solution (solution chosen by the manufacturer)
overpressure valve can not be adjusted (from checking where they were found to malfunction) by
the staff of the beneficiary unit, then the supplier will undertake, by contract, that will restore the
original operating parameters of the valve at its expense throughout the lifespan of these devices,but not less than 10 years.
4.4. Valve type with excess demand, which ensures a positive pressure according to SR EN 137.
4.5. Demand valve will have a purge button (additional flow) will be located frontal (central).
4.6. Demand valve must be able to hook up / disconnect quickly the mask.
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
34/45
4.7. Facial mask with the following characteristics:
4.7.1. The viewfinder must be wide.
4.7.2. Have at least five fastening adjustable straps.
4.7.3. Have valve (valves) of exhalation adjustable
4.7.4. If due to the constructive solution of the mask (solution chosen by the manufacturer) the
exhalation valves can not be adjusted ( where at their verification have found their disorder)
exhalation valves can not be adjusted by the staff of the beneficiary unit, then the supplier will
undertake, by contract, that will restore the original operating parameters of the exhalation valveat its expense throughout the lifespan of these devices, but not less 10 years.
4.7.5. Have acoustic membrane to allow placement of a communications system without
affecting the tightness of the mask mounting system.
4.7.6. Be inspired system that allows the viewfinder demisting operation.
4.7.7. To be equipped with integrated support for frame glasses.
4.8. Dorsal plate with the following characteristics:
4.8.1. To ensure fixation of compressed air cylinder and pressure reducer with the other
components (hoses).
4.8.2. Have provided protection for the balance against lateral movements.
4.9. The harness should:
4.9.1. Provide ergonomic fixing device
4.9.2. It has the following composition:
4.9.2.1. Shoulder straps with pads (cushions made of fireproof materials: leather, para-aramid,
etc.).
4.9.2.2. Ring back cushion (pillow made of fireproof materials: leather, para-aramid, etc.).
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
35/45
4.9.2.3. Elements (fluorescent, reflective, luminescent, etc..) visible in dark places.
5. SPECIFICATIONS.
5.1. Design features
5.1.1. Weight fully equipped with a loaded air cylinder rated pressure: max. 14 kg.;
5.1.2. The materials used in contact with the skin of the wearer must not cause irritation or illness
according to SR EN 136:2002/AC 2004;
5.1.3. The unit will be fitted with a device providing additional air flow for the extreme and
supply of two users simultaneously.
5.2. Functional Features:
5.2.1. Environmental conditions for normal operating temperature:- 300 + 600;
5.2.2. Air flow which is still maintained positive pressure: minim 300 l/min;
5.2.3. Audible warning device must begin to operate at a pressure of 55+5 bars.
5.3. Other conditions
5.3.1. Nominal pressure cylinder load will be 300 bar and the capacity of 6.8 liters per cylinder;
5.3.2. The cylinders will be marked according to the legislation in force;
5.3.3. The quick coupling (mounting medium pressure hoses, which connects the mask to power
and other consumer) must be sealed to atmosphere a maximum working pressure of 15 bar, both
bundled and unbundled position;
6. FINAL REQUIREMENTS
6.1. The guarantee of the equipment to be at least three years;
6.2 Technical documentation and accompanying materials of each product will be following:
6.2.1. Technical Book of knowledge, operation, maintenance and repair;
6.2.2.Book records of maintenance and repair
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
36/45
6.2.3 Classification codes related parts;
6.2.4. The list of units that can provide service during the warranty and post warranty;
6.2.5. Warranty certificate ;
6.2.6. Statutory declaration of conformity
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
37/45
Annex no. 10
TETRA PORTABLE TERMINALS SPECIFICATIONS
1. Terminals certification for national TETRA Platform and AIM support
TETRA Terminals will be working on a TETRA MOTOROLA infrastructure (Dimetra IP ver.
6.1); ocazionally, terminals will be migrating from Dimetra IP infrastructure to the coverage of
another TETRA infrastructure(EADS TETRA).Having the above in consideration, TETRA Terminals:
a. Have to be ISCOM certified for MOTOROLA TETRA infrastructure (DIMETRA IP 6.0 or
following versions). For each terminal type, The Bidder has to provide of first page of ISCOM
issued certification and mention the link-ul (URL) towords ISCOM certification published on
TETRA Association website-ul (ex TETRA MoU).
b. Have to be ISCOM certified for EADS TETRA infrastructure (NTS 4.5 or following
versions). For each terminal type, The Bidder has to provide of first page of ISCOM issued
certification and mention the link-ul (URL) towords ISCOM certification published on TETRA
Association website-ul.
c. Have to be certified by Dimetra IP infrastructure operator, implemented in Romania (S.T.S.).
The procedure is published on S.T.S. website-ul, URL:
www.stsnet.ro/documente/Procedura_TETRA.pdf). For each Terminal type the winning Bidder
(Contracter) will provide S.T.S. issued certifcate.
d. Has to be able to support multiple networks (MNC/MCC) based on a Terminal programmed
list.
e. Has to be able to support AIM (Air Interface Migration signalling), according to ETSI 300
392-2, conditions 15 and 16 (articles regarding migration) and TIP TTR001-06 or subsequent to
(TETRA Association). Before signing the contract, the winning Bidder has to practically attest
this functionallity. Functionallity wil be shown by winning Bidder organized tests , with
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
38/45
equipments (example: TETRA test platforms supporting AIM) made available by the Bidder
during the tests). All due costs will be supported by the winning Bidder.
2. Standardization and Certification
2.1. TETRA terminals provided shall comply with ETSI TETRA standards relevant, including:
a. 300 392 TETRA V+D air interface;
b. 300 394 TETRA V+D conformance testing;
c. 300 395 TETRA speech codec;
d. 300 396 TETRADMO.
2.2. TETRA terminals provided must be certified as required by section 1.
3. Environment
TETRA Terminals must offer the following environmental:
a. Operating temperature: -20..+55oC
b. Storage temperature: -30..+60oC
c. Humidity: ETSI ETS 300 019
d. Shock and vibration: ETSI ETS 300 019
e. Dust and water protection: IP 54
4. RF
TETRA terminals must have the following features RF:
a. RF Band (TMO&DMO): 380-385 MHz 390-395 MHz
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
39/45
b. Duplex spacing: 10 MHz
c. Adjacent channel spacing: 25 KHz
d. Static sensitivity: -112 dBm
e. Dynamic sensitivity: -103 dBm
f. Receiver Class A
g. Power Tx: 1 W
5. TETRA services and features
TETRA Terminals must offer the following services and features to support TETRA:
5.1. Voice Services
a. group call (GC) in TMO & DMO (TMO least 100 pre-programmed groups, minimum 50
BMD groups pre-programmed)
b. Emergency Call
c. Individual Call (IC);
d. Phone call /w// duplex (PABX/PSTN).
5.2. Additional Services
a. TPI;
b. CLIP;
c. DGNA;
d.Late entry;
e. Priority Call;;
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
40/45
f. Scan groups (at least 3 groups to scan)
5.3. Data Services
a. SDS/SDS-TL;
b. Status Messages
c. IP PDS;
d. PEI interface for external DTE connection that supports RS232
5.4. Mobility
a. Terminals must support cell reselection: initial cell selection, undeclared cell reselection,
unanounced cell reselection, announced cell reselection type 3or superior (according to ETSI
TETRA 300 392-2).
b. Must support multiple networks (MNC) from a list of scheduled terminal.
c. Must support AIM.
5.5. Security
a. Login. Authentication key must be provided in a format as recommended by the TETRA
Association. Authentication key must be provided in compliance with safety standards
established by the recommendations of the TETRA Association SFPG.
b. Radio interface encryption (algorithms supported: TEA1 i TEA2). Terminals shall be
provided to the algorithm TEA2.
c. Security Class: class 1, class 2 i class 3.
d. Disable / Enable terminal (Remote disable/enable)
5.6. Other features
a. Tx inhibit
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
41/45
6. Mechanical Specifications:
a. Dimensions (HxWxD): < 150x60x40 mm (with standard battery)
b. Mass : < 290 g (with standard battery)
7. Interfaa cu utilizatorul(MMI)
a. Display
- High-resolution color display: minim 128x128pixels, minim 32k culors, support for displayingpictures;- Indicators for display on display modes (for example TMO, DMO, Tx inhibitetc.)
- Intuitive operating menus;
b. Keyboard
-Alphanumeric keyboard;
-menu navigation keys;
-
button / key for emergency call initiation;-button / key to select group;
-button / key for volume;
- keypad lock;
c. Phonebook
- Phonebook (Capacity: minimum 70 entries)
- Call easy (eg by searching the phonebook, last dialed numbers, etc.).
d. Audio & programming interface / data
- audio amplifier and speaker;
- Audio Mode: Speaker / discreet (loud/discrete);
- possible use audio accessories;
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
42/45
- multipurpose interface for programming / data.
8. Battery
a. Battery Type: Litiu-Ion or Litiu Polimer
b. Autonomy mode 5/5/90 (Tx/Rx/Standby): 16 ore
9.Accessories
For each terminal must be provided with the following accessories:
- handsfree consisting: microphone PTT button (provided with clip attachment to lapel) and
headset (which is inserted into the ear) with coiled cable;
- portable terminal clamp fixing to the belt;
- Travel Charger;
- car charger.
For 20% of the terminals will provide RS232/USB data cable.
10. Be provided for each terminal user's manual in Romanian.
11. Programming terminal
11.1. The programming terminal must be effected using an IBM compatible PC equipped with
RS232/USB port and Windows NT operating system.
11.2. The seller must provide software programming and programming interfaces for terminal 4.
11.3. The seller must instruct staff of the Buyer to schedule terminals, including practical
training will be.
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
43/45
12. Integrated GPS Receiver
12.1. TETRA portable terminal must be equipped with integrated GPS receiver.
12.2. TETRA Portable Terminal with GPS receiver must support ETSI Location Information
Protocol LIP (TS 100-392-18).
13.3. Integrated GPS receiver:
The terminals must be equipped with integrated GPS receiver according to the following
specifications:
a. satellites simultaneously receive: minim 10
b. sensitivity: minim -152 dBm
c. Precision max 5 m (probabilitate 50%)
max 10 m (probabilitate 95%)
d. Active GPS antenna integrated into TETRA antenna.
13. Terminal Warranty: 2 years.
Acronyms
AIM Air Interface Migration signalling
ARL/AVL Automatic Resource/Vehicle Location
CLIP Calling Line Identification Presentation
DMO Direct Mode Operation
DGNA Dynamic Group Number Assignment
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
44/45
DTE Data Terminal Equipment
ETSI European Telecommunications Standards Institut
GC Group Call (apel de grup)
GPS Global Positioning System
IC Individual Call
IP Internet Protocol
ISCOM Istituto Superiore delle Comunicazioni e delle Tecnologie dellInformazione
(Laboratorul Ministerului Italian pentru Communicaii i Tehnologia Informaiei)
LIP Location Information Protocol
MNC Mobile Network Code
MCC Mobile Country Code
PABX Private Automatic Branch eXchange
PC Personal Computer
PDS Packet Data Services
PEI Peripheral Equipment Interface
PIN Personal Identification Number
PPC Pocket PC
PTT Push To Talk
PSTN Public Switched Telephone Network
RF Radio Frequency
SFPG Security and Fraud Prevention Group
SDS Short Data Services
-
7/26/2019 Spec Teh Descarcerarea Grea - Eng
45/45
SwMI Switching and Management Infrastructure
TEA TETRA Encryption Algorithm
TETRA TErrestrial Trunked RAdio
TFT Thin Film Transistor
TL Transport Layer
TMO Trunk Mode Operation
TPI Talking Party Identification
Tx Transmit
V+D Voice + Data
VOX Voice Operated
WAP Wireless Application Protocol