UNITATE ROOF TOPRefrigerent R-410A
Modele:
SKNL - B180NM29E 46.88 kWSKNL - B240NM33E 60.36 kWSKNL - B300NM39E 77.94 kW
Manual Tehnic
2
Cuprins
Caracteristici ale unit`\ii .........................................................................................2Procedura de selec\ie ............................................................................................7Identificarea modelului. Optiuni ..............................................................................9Date Generale .......................................................................................................11Date de performan\` .............................................................................................12Performan\a debit de aer .......................................................................................15Date electrice .........................................................................................................18Dimensiuni .............................................................................................................19Accesorii ................................................................................................................23Specifica\ii mecanice .............................................................................................35Scheme electrice ...................................................................................................42
Caracteristici ale unit`\ii Dotarea standard a unit`\ii include:- refrigerent R-410A HFC;- unitatea este incarcat` cu freon din fabric`, are toate conexiunile electrice efectuate ]i este complet testat`;- compresoare scroll cu protectie electric` la supra[nc`rcare ]i la suprapresiune;- compresoare cu dou` trepte de func\ionare;- debit de aer convertibil - vertical inpartea inferioar` ]i orizontal pe lateral;- sistem de m`surare TVX, a refrigerentului pe fiecare circuit;- protec\ie standard la toate modelele, la [nalt` ]i joas` presiune;- filtru usc`tor pe fiecare linie de lichid;- schimbatoarele de c`ldura ale evaporatorului ]i ale condensatorului sunt cu o singur` trecere, cea ce permite o cur`\are mai u]oar` pentru men\inerea eficien\ei;- poate lucra in regim de r`cire p@n` la temperaturi de 51 oC;- izola\ia termica a unit`\ii este [ncapsulat` cu folie de aluminiu pentru a nu permite poluarea atmosferica cu fibre din izola\ie;- u]i de aces cu balamale rezistente ]i cu garnituri de etan]are pentru condi\ii grele de explo-atare, [ncuietoare cu 1/4 tur`;- se permite demontarea u]oar` a ansamblului ventilator;- vopseaua utilizata corespunde standardului ASTMB 117, foaia de tabll` laterala este galva-nizat` pentru o mai bun` protec\ie;- ]asiul prev`zut cu orificii pentru alimentarea ]i golirea apei;- ]asiul este prev`zut cu loca]uri pentru lamele stivuitorului pentru a putea fi mai u]or de transportat;- alimentarea electric` se face [ntr-un singur punct;- t`vi\` de condens extractibil` cu pant` interioar` conform standardelor ASHRAE 62;- motor electric performant cu curea de transmisie ]i sistem rapid de reglare a intinderii curelei;- motoarele de la ventilatoare sunt de tipul cu ungere permanent`;- motoarele electrice au protec\ie intern`;- filtru de 2 inch extractibil pe sanie;- valv` de gaz cu dou` trepte de func\ionare, aprindere direct` cu sc@nteie ]i tiraj for\at pen-tru eficien\` ]i anduran\`;- controlor electronic al arderii cu afi]area eventualelor mesaje de eroare;
3
- sistem de control pe 24V cu siguran\e resetabile- fire electrice diferit colorate ]i etichetate;- schimb`toarele de c`ldura din tuburi de cupru cu aripioare de aluminiu.
Unit`\ile RHEEM sunt destinate cerin\elor actuale ale pie\ei. Design-ul lor permite atingerea unei calit`\i [nalte, anduran\` mare [n exploatare, instalare ]i [ntre\inere u]oar`. Eticheta, 1, Commercial SeriesTM identific` brand-ul.
Carcasa metalic`, 2, include 20 de componente ]i materiale galvanizate. Pentru prote-jarea eta]eit`\ii carcasei sunt utilizate panouri [n]urubate cu garnituri ]i sisteme de picurare, 3, de 1/8”. Panoul inclinat, 4, protejeaz` schimbatorul de c`ldur`. Fiecare unitate RHEEM este vopsit` prin electrodepunere pentru a corespunde testelor de 1000 de ore de stropire cu ap` s`rat`, cerute de ASTM B 117.
}asiul, 5, are prev`zute gauri de ridicare cu stivuitorul ]i orificii de conectare pentru a u]ura montajul. }asiul este ]tan\at cu forme de dimensiunea de 1 1/8” [n jurul orificiilor de tur ]i retur ]i elimin` posibilitatea p`trunderii apei [n spa\iul condi\ionat, 6. T`vi\a de condens este produs` din material rezistent la ac\iunea bacteriilor ]i are [nclinare pentru a satisface cele mai exigente cerin\e. T`vi\a de condens se poate scoate prin alunecare pentru o mai bun` cur`\are. Izola\ia a fost plasat` in partea de jos a ]asiului, ]mpiedic@nd acumularea de umiditate propice dezvolt`rii bacteriilor. Izola\ia este prins` cu adeziv ]i sisteme mecanice ]i toate muchiile sunt ascunse.
In timpul dezvoltarii produsului, fiecare unitate a fost testat` conform UL 1995, ANSI 21, 47, AHRI 340-360. Unita\ile Rheem sunt produse [ntr-un regim de management al calit`\ii conform ISO 9001. Fiecare unitate este etichetat` UL ]i AHRI, 8.
Accesul la majoritatea compartimentelor sa face pe la partea frontal`, inclusiv la filtre
4
]i la compartimentul electric, compartimentul ventilatoarelor, arz`tor. Fiecare panou este inscriptionat cu numele compartimentului (control/filtru, ventilator, arz`tor etc.).
Accesul la compartimentul electric ]i la filtre este asigurat de o u]a larg`, cu [nchidere cu broasc` ]i cheie. Pe acest` us` se g`se]te o etichet` ce con\ine: modelul, nr. de serie, date electrice ]i o serie de alte informa\ii utile.
Schema de alimentare electric` este localizat` [n interiorul compartimentului electric ]i al filtrelor. Schema electric` este pe capacul unit`\ii de control. Pe partea dreapt` a unit`\ii de control se g`sesc etichetate modelul ]i seria unit`\ii de control. Eticheta aplicat` de labora-torul produc`torului care a testat calitatea unit`\ii este [n pozi\ia 9. Filtrele se pot scoate u]or datorit` sistemului de montaj ]i se pot [nlocui [n loca]ul 10.
{n interiorul controlerului, fiecare component` este clar identificat` prin etichetare astfel [nc@t s` poat` fi localizat u]or pe schema electric`. Toate firele sunt colorate ]i nu-merotate s` corespund` schemei electrice. Unitatea de control a arderii, incorporeaz` un LED care permite identificarea eventualelor erori ap`rute [n func\ionarea arz`torului. Codurile de avarie (modul de pulsare a LED-ului) sunt eviden\iate pe schema electric`. Sistemul de alimentare include ]i un [ntreruptor pe circuitul de tensiune joas`. Tot [n panoul electric exist` c@te un contactor pe fiecare compresor din circuitul de frig.
Exist` posibilitatea mont`rii din fabric` a unui m@ner de deschidere a panoului electric ]i cu func\ie de [ntreruptor general, 12. Firele de tensiune joas` ]i [nalt` pot intra pe la ]asiu. Alimentarea cu tensiune joas` se face la rigleta pentru tensiune joas`. Pentru un aces mai u]or, UL solicit` ca bariera de tensiune joas` s` poat` fi temporar mutat`la terminalele de tensiune joas` ]i apoi s` revin`. Conexiunea firelor de alimentare cu tensiune [nalt` se face la bornele corespunz`toare. U]a exterioar` are prev`zute dou` orificii, 13, pentru instalarea suplimentar` de man-ometre.
5
Compartimentul ventilatoarelor se afl` [n dreapta compartimentului de control. Pen-tru a se asigura un acces u]or la ventilatoare, [ntregul ansamblu poate aluneca afar` pe o sanie dup` ce aceasta va fi deblocat` prin de]urubarea a 4 ]uruburi de M10. Fulia motoru-lui electric,14 ]i [ntinderea curelei se poate regla prin sl`birea ]uruburilor de prindere de pe laturile motorului. Desfacerea complet` a ]uruburilor permite scoaterea u]oar` a fuliei ]i/sau a curelei de transmisie prin [mpingerea motorului p@n` la sl`birea total` a curelei. Odat` ce cureaua de transmisie a fost scoas`, rola motorului poate fi adaptat` pentru 6 m`rimi ce vor da tura\ii diferite c`tre ventilator. Cutia de transmisii este silen\ioas` ]i eficient`. Fulia venti-latorului are prinderea de ax securizat` printr-o ]aib` elastic` tip “H”. Totodat` ]aiba elastic` permite demontarea rapid` a fuliei [n caz de necesitate, comparativ cu sistemul de prindere cu ]urub.
{n interiorul compartimentului ventilatoarelor se poate instala optional controler-ul 16. Acest controler permite operarea compresoarelor la temperaturi ambientale sub 0 oC prin ini\ierea unui ciclu de func\ionare a ventilatoarelor la presiune mare. controler-ul; se poate instala u]or cu ajutorul unor fitinguri ]i a unei cuple electrice polarizate.
Din compartimentul ventilatoarelor se poate vedea o evaporatorul. Evaporatorul are [nglobat` teh-nologia avansat` a tubulaturii cu caneluri interioare pentru a realiza maximum de transfer termic. Sistemul de m`surare TXV asigur` chiar ]i distribu\ia corect` de refrigerent [n evaporator. Toate firele electrice, [n unitate, sunt
[nm`nunchiate ]i au trasee bine stabilite. ori de c@te ori un m`nunchi de fire traverseaz` o pies` metalic`, traversarea,17, este dotat` cu garnituri de cauciuc care s` [mpiedice frecarea si dezizolarea firelor. Compartimentul de ardere [nglobeaz` cea mai modern` tehnologie existent` pe pia\`. Ventilatoarele, 18, introduc for\at aer in camerele de ardere,19, iar gazele fierbin\i schim` cal-dur` cu aerul de [nc`lzit [n schimb`toarele ignitubulare, 20. {n caz de necesitate, aplica\ii cu rat` mare de aer proasp`t sau medii corozive, schimb`toarele de c`ldur` se pot realiza din o\el inox. Fiecare arz`tor este echipat cu o van` de gaz cu dou` trepte de func\ionar, prima treapt` pentru 50% din putere, a doua pentru 100% din putere. Eficien\a de 81% este ob\inut` prin optimizarea combustiei realiz@ndu-se un amestec bun aer/gaz prin injec\ie multipl` ]i mentinerea unui raport c@t mai apropiat de raportul stoechiometric pentru fiecare treapt` [n parte.
6
Aprinderea direct` cu sc@nteie, 22, asigur` aprinderea combustibilului [n cele mai grele condi\ii. Aprinderea este cuplat` cu un senzor de flac`r`, 23, pentru a se controla ca flac`ra s` se dezvolte [n [ntreg volumul camerei de ardere. Conexiunea la alimentarea cu gaz combustil se poate realiza pe lateral sau prin ]asiu. Elementele de siguran\` ale arz`torului:- presostat de gaz, 24, pentru a asigura amestecul combustibil necesar;- presostat de fum, 25, pentru a se asigura c` schim`torul de c`ldur` nu este obstruc\ionat ]i gazele se por evacua corect;- termostat de supratemperatur`.
Compresoarele, 26, sunt compresoare scroll, recunoscute pentru anduran\a lor, pentru func\ionare eficient` ]i silen\ioas`. Traseele de aspira\ie ]i refulare ale compresoare-lor sunt au prev`zute curbe de absorb\ie a ]ocurilor, 27, ce pot apare la pornirea ]i oprirea compresoarelor. Fiecare compresor deserve]te un circuit independent pentru o mai bun` reliabilitate [n func\ionarea ma]inii.Fiecare compresor poate func\iona [n dou` trepete, prima treapt` 50% din totalul puterii, a doua treapt` la 100% putere.
Presostatele de joas` presiune , 28, ]i de [nalt` presiune, 29, sunt montate pe fiecare circuit [n zona condensatorului. Presostatul de [nalt` presiune va opri func\ionarea compre-sorului atunci cand presiunea dep`]e]te 42 bar sau ventilatoarele nu func\ioneaz` normal. presostatul de joas` opre]te func\ionarea compresoarelor [n cazul pierderilor de freon. Este disponibil` dotarea ma]inii cu protec\ie anti[nghe\, aceasta ac\ioneaz` asupra compresorului dac` pe serpentina evaporatorului temperatura coboar` sub limita de [nghe\. Ventilatorul condensatorului, 30, poate fi accesat u]or pentru opera\iile de [ntre\inere prin demontarea grilei ventilatorului. Conectorul polarizat permite alimentarea rapid` a mo-torului ]i elimin` necesitatea [n]iruirii de cabluri de alimentare prin unitate.
Schimb`torul de c`ldura are serpentina, 31, realizat` din \eav` de cupru canelat` pen-tru a ob\ine o eficien\` ridicat` a schimbului termic. Fiecare unitate este proiectat` s` func\ioneze pentru ambele tipuri de aplica\tii, cu jet
7
de aer descendent sau cu ie]ire orizontal`, 32. Compartimentul de retur aer poate fi dotat, la cerere, cu un economizor de temperatur`, 33. Fiecare unitate este cablat` electric [n even-tualitatea mont`rii unui economizor. Optiunea de economizor a fabricii este de economizor cu jet descendent. Economizorul care permite “free cooling”, c@nd temperaturile exterioare o permit, permite ]i alimentarea cu aer proap`t, ca dotare standard cu control al entalpiei. La cerere se poate livra ]i cu controler dual entalpic. Motorul cu ac\ionare direct` combinat cu clapete ac\ionate cu reductor a eliminat necesitatea regl`rii la locul instal`rii. controlorul economizorului are cateva puncte de setare: unul de minim al temperaturii, al doilea ame-stecul de aer ]i al treilea concentra\ia de dioxid de carbon. presiunea de ie]ire este controlat` barometric. Soclu de montaj, 34, este construit asfel [nc@t sa confere flexibilitate ]i simplicitate [n instalare.
Procedura de selec\ie Pentru a selecta una din unit`\ile tip SKNL-B pentru anumite cerin\e, prezent`m mai jos procedura de urmat cu exemplificare:
1. Determinarea necesarului termic pentru [nc`lzire ]i r`cire ]i a condi\iilor specifice de operare conform planurilor ]i specifica\iilor. Exemplu:tensiune 400V - 3 faze - 50HzCapacitate total` r`cire 57.1 kWCapacitate sensibil` r`cire 43.9 kWCapacitate de [nc`lzire 73.3 kWTemp.intrare aer condensator 35 oC bulb uscatTemp.intrare aer mix evaporator 18.3 oC bulb umed 25.6 oC bulb uscatDebit de aer (vertical)* 12232,8 m3/hPresiune static` extern`* 170 Pa
2. Selectarea unit`\ii pentru a [ndeplini cerin\a de r`cire- in tabelul de Date Generale se alege unitatea cu putere nominal` de r`cire egal` sau imedi-at superioar` capacita\ii totale de r`cire solicitat` de proiect. In cazul nostru se alege unitatea SKNL-B240NM33E, cu puterea max. de r`cire de 60.36 kW.- in tabelul de performan\` pentru tipul de unitate aleas` se determin` domeniul de performan\` al unit`\ii func\ie de temperatura aerului exterior (intrare [n condensator), [n cazul nostru 35 oC ]i func\ie de temperatura de intrare a amestecului de aer [n condensator, [n cazul nostru 18.3 oC. Pentru ca temperatura din proiect nu este cea din tabel se determin` valorile cele mai apropiate de temperatur`, respectiv 17.2 oC ]i 19.4 ]i pentru aceste valori se selecteaz` din tabel puterile totale, sensibil` ]i puterea electric` necesar` la valorile medii de debit aer. Datele selectate sunt:
Temperatura 17.2 oCCapacitate total` r`cire = 57.5 kWCapacitate sensibil` r`cire = 52.0 kWPutere electric` necesar` = 15.0 kW
Temperatura 19.4 oCCapacitate total` r`cire = 60.5 kWCapacitate sensibil` r`cire = 45.2 kWPutere electric` necesar` = 15.2 kW
8
Pentru a determina aceste valori la temperatura impus` de proiect se va face interpo-larea pentru 18.3 oC folosind urm`toarele formule:
Putere total` 57.5+(60.5-27.5)*(18.3-17.2)/(19.4-17.2) = 59.0 kW Putere sensibil` 52+(52-45.2)*(18.3-17.2)/(19.4-17.2) = 48.6 kW Putere electric` necesar` 15+(15.2-15)*(18.3-17.2)/(19.4-17.2) = 15.1 kW
3. Corectarea capacit`\ilor de la pct.2 pentru debitul de aer necesarUtiliz@nd tabelul Factori de Corectie func\ie de debitul de aer se selecteaz` factorii de corec-tie pentru unitatea aleas` la punctul 1 ]i pentru debitul de aer din proiect, 12232,8 m3/h. Se corecteaz` valorile puterilor determinate la punctul 2 cu acesti factori rezult@nd:
Capacitate total`= 59.0*1.02 = 60.18 kWCapacitate sensibil`= 48.6*1.06 = 51.52 kWPutere necesar`= 15.10*1.01 = 15.25 kW
4. Determinarea tura\iei ]i puterii ventilatorului pentru a acoperi cererea proiectuluiSe determin` presiunea static` prin ad`ugarea, din tabelul Pierderea de Presiune pe Aer la Componentele Unit`\ii, la presiunea static` data de proiect (170 Pa), 0 Pa pentru serpentina umed` ]i 20 Pa pentru fluxul de aer vertical, rezult` o presiune static` necesar` de 190 Pa.In tabelul Performan\a Unit`\ii func\ie de debitul de aer ]i presiunea static` se detemin` pen-tru valoarea presiunii statice determinat` si pentru debitul de aer din proiect valorile tura\iei ]i puterii ventilatorului:
RPM (tura\ia) = 748Puterea (watt) = 3058Motor = M (7.5 HP motor)
6. Calculati capacitatea de r`cire net`, egal` cu capacitatea grosier`, pasul 3, minus c`ldura dat` de ventilatorul intern.
Capacitate net` total` = 60.18 - 3.058 = 57.122 kW Capacitatea sensibil` net` = 51.52 - 3.058 = 48.462 kW
7. Calcularea puterii necesare ]i a EER
Puterea necesar` = 15.25 + 3.058 = 18.308 kW
EER = Capacitate net` total`/Puterea necesar` = 57.122 / 18.308 = 3.120
8. Selectarea capacit`\ii de [nc`lzireDin tabelul cu Date Generale citi\i c` puterea dat` de arderea gazului (putere necesar` x eficien\`) este:
Capacitate de [nc`lzire: 78.2 kW
9. Alege\i modelul SKNL-B240NM33E
NOT~: Aceste condi\ii de operare sunt tipice pentru aplica\iile comerciale 35/26 oC tempera-
9
turi de proiectare cu date de proiect de interior de 24 oC bulb uscat, 50% umiditate relativ` ]i 10% aer ventilat, cu unitatea rooftop montat` ]i centrat` pe zon` ]i cu leg`turi prin ducturi.
Identificarea modelului. Optiuni
Codurile op\iunilor instalate de fabric` pentru modelele SKNL-B 180/240/300
Cod Schimb`tor c`ldur` o\el inox
F`r` priz` pt.alimentare elec-tric` suplimentar`
Kit de functionare la temperaturi scazute
AA nici o op\iune
AJ x
AH x
AP x
JB x x
CW x x x
Codificarea selec\iei economizoarelor pentru SKNL-B 180/240/300
Cod F`r` economizor
Economizor cu semnal de la 1 senzor entalpic, pentru conectarea tubulaturilor pe
dedesubt
Economizor cu semnal de la 1 senzor entalpic, pentru conectarea tubulaturilor pe dedesubt + detector de fum
A x
B x
C x
10
Mod de codificare a modelelor de comandat: Cele trei caractere de dupa descrierea modelului vor fi utilizate pentru comandarea optiunilor instalate de fabric`. Dup` specificarea modelului de baz` al rooftopului, alege\i op\iunea cu dou` caractere din tabelul Codurile op\iunilor instalate de fabric`. Ultimul caracter este utilizat pentru a desemna tipul de economizor instalat de fabric`.
Exemplu: f`r` op\iuni SKNL-B 240NM33E
Exemplu: f`r` op\iuni, cu economizor instalat din fabric` SKNL-B 240NM33EAAB
Exemplu: Kit de functionare la temperaturi scazute, f`r` priz` pentru alimentare elec-tric` suplimentar` ]i schimb`tor din o\el inox f`r` economizor instalat de fabric` SKNL-B 240NM33ECWA
11
Date Generale
CaracteristiciModel
B180NL29E B240NM33E B300NM39E
Putere totala racire [kW] 46.88 60.36 77.94
Debit max. aer [mc/h] 8704.8 11253.6 13932.0
Putere neta racire [kW] 45.71 58.60 74.42
Putere sensibila neta racire [kW] 34.34 43.31 54.73
Putere latenta neta [kW] 11.37 15.29 19.69
Putere neta sistem [kW] 13.46 17.14 24.07
IncalzirePutere in focar (treapta 1/treapta 2) [kW] 42.48/84.97 48.34/96.69 58.60/117.20
Putere utila incalzire (treapta 1/treapta 2) [kW] 34.43/68.85 39.12/78.23 47.47/94.93
Dif. de temperat. aer (treapta 1/treapta 2) [oC] 16.7/33.3 13.9/30.6 13.9/30.6
Randament nominal arzatoare [%] 81 81 81
Nr. duze 14 14 14
Trepte de functionare arzator 2 2 2
Racord gaz [inch] 3/4 3/4 3/4
CompresorNr./tip compresoare 2/scroll 2/scroll 2/scroll
Putere sonora [dB] 91 91 92
Schimbator de caldura exteriorTipul tevii riflata riflata riflata
Diam. exterior teava [mm] 9.5 9.5 9.5
Suprafata [mp] 4.95 4.95 4.95
Serpentine 1 2 2
Schimbator de caldura interiorTipul tevii riflata riflata riflata
Diam. exterior teava [mm] 9.5 9.5 9.5
Suprafata [mp] 2.48 2.48 2.48
Serpentine 2 3 4
Control refrigerent Valve TX Valve TX Valve TX
Racord condens [nr/mm] 1/25.4 1/25.4 1/25.4
Ventilatoare externNr./diametru in [mm] 4/609.6 6/609.6 6/609.6
Mod actionare/viteze directa/1 directa/1 directa/1
Debit [mc/h] 27180 33638.4 33638.4
Nr. motoare/HP 4 la 1/3HP 6 la 1/3HP 6 la 1/3HP
Turatie motor [rpm] 1075 1075 1075
Ventilatoare intern centrifugal centrifugal centrifugal
Nr./diametru in [mm] 2/(457x229) 2/(457x229) 2/(457x229)
Mod actionare/viteze curea/variab curea/variab curea/variab
Nr. motoare 1 1 1
Putere motor [HP] 3 7 1/2 10
Turatie motor [rpm] 1725 1725 1725
Dimensiune cadru motor 56 213 215
12
Filtru schimbabil schimbabil schimbabil
Dimensiunea [mm x mm x mm] 51x635x508 51x635x508 51x635x508
Incarcare cu refrigerent (sist1/sist2) [g] 5812/5982 11397/9384 9611/10121
MasaNeta [kg] 894 1062 1095
Gross [kg] 939 1107 1140
Date de performan\` pentru modelul - B180
Temperatura aer intrare [n vaporizator 26.7 oC bulb uscat
wbE* 21.7 oC 19.4 oC 17.2 oC
Debit aer mc/h 10195.2 8708.4 6796.8 10195.2 8708.4 6796.8 10195.2 8708.4 6796.8
Fact.cor. putere sens. 0.05 0.08 0.13 0.05 0.08 0.13 0.05 0.08 0.13
TE
MP
ER
AT
UR
A A
MB
IEN
T B
ULB
US
CA
T oC
23.9
Totala kW 57.7 56.0 53.7 54.1 52.5 50.4 51.9 50.3 48.3
Sensib. kW 35.7 31.4 31.4 43.0 38.2 38.2 48.6 43.5 43.5
Putere kW 9.8 9.6 9.5 9.6 9.5 9.3 9.5 9.3 9.2
26.7
Totala kW 56.5 54.8 52.6 52.9 51.3 49.3 50.6 49.1 47.1
Sensib. kW 35.1 30.8 30.8 42.4 37.7 37.7 48.0 42.9 42.9
Putere kW 10.4 10.2 10.0 10.2 10.1 9.9 10.1 9.9 9.7
29.4
Totala kW 55.1 53.4 51.3 51.5 50.0 48.0 49.2 47.8 45.9
Sensib. kW 34.4 30.2 30.2 41.7 37.1 37.1 47.3 42.3 42.3
Putere kW 11.0 10.8 10.6 10.8 10.7 10.5 10.7 10.5 10.3
32.2
Totala kW 53.6 52.0 50.0 50.1 48.6 46.6 47.8 46.4 44.5
Sensib. kW 33.6 29.5 29.5 40.9 36.4 36.4 46.5 41.7 41.7
Putere kW 11.7 11.5 11.3 11.5 11.4 11.1 11.4 11.2 11.0
35.0
Totala kW 52.1 50.5 48.5 48.5 47.1 45.2 46.2 44.8 43.0
Sensib. kW 32.8 28.8 28.8 40.1 35.7 35.7 45.7 40.9 40.9
Putere kW 12.4 12.2 12.0 12.3 12.1 11.9 12.1 11.9 11.7
37.8
Totala kW 50.5 48.9 47.0 46.9 45.5 43.7 44.6 43.2 41.5
Sensib. kW 31.9 28.1 28.1 39.2 34.9 34.9 44.6 40.2 40.2
Putere kW 13.2 13.0 12.8 13.1 12.9 12.6 12.9 12.7 12.5
40.6
Totala kW 48.7 47.2 45.4 45.2 43.8 42.0 42.8 41.5 39.9
Sensib. kW 31.0 27.2 27.2 38.3 34.1 34.1 42.8 39.3 39.3
Putere kW 14.1 13.9 13.6 13.9 13.7 13.4 13.8 13.6 13.3
43.3
Totala kW 49.6 45.4 43.6 43.3 42.0 40.3 41.0 39.8 38.2
Sensib. kW 29.9 26.3 26.3 37.3 33.2 33.2 41.0 38.4 38.2
Putere kW 15.0 14.7 14.5 14.8 14.6 14.3 14.7 14.4 14.2
46.1
Totala kW 44.9 43.6 41.8 41.4 40.1 38.5 39.1 37.9 36.4
Sensib. kW 28.9 25.4 25.4 36.2 32.3 32.3 39.1 37.5 36.4
Putere kW 15.9 15.7 15.4 15.8 15.5 15.2 15.6 15.4 15.1
48.9
Totala kW 42.9 41.6 39.9 39.3 38.1 36.6 37.0 35.9 34.5
Sensib. kW 27.7 24.4 24.4 35.0 31.3 31.3 37.0 35.9 34.5
Putere kW 16.9 16.7 16.4 16.8 16.5 16.2 16.6 16.4 16.1
wbE - temperatura de intrare [n vaporizator, bulb umed
13
Date de performan\` pentru modelul - B240
Temperatura aer intrare [n vaporizator 26.7 oC bulb uscat
wbE* 21.7 oC 19.4 oC 17.2 oC
Debit aer mc/h 14194.8 11257.2 8496 14194.8 11257.2 8496 14194.8 11257.2 8496
Fact.cor. putere sens. 0.09 0.11 0.17 0.09 0.11 0.17 0.09 0.11 0.17
TE
MP
ER
AT
UR
A A
MB
IEN
T B
ULB
US
CA
T oC
23.9
Totala kW 70.2 68.7 65.7 66.2 64.8 62.0 63.1 61.8 59.0
Sensib. kW 41.6 38.0 38.0 50.9 46.9 46.9 57.9 53.6 53.6
Putere kW 12.2 12.1 11.8 12.0 11.9 11.6 11.8 11.7 11.5
26.7
Totala kW 69.4 68.0 65.0 65.5 64.1 63.3 62.3 61.1 58.3
Sensib. kW 41.3 37.8 37.8 50.7 46.7 46.7 57.7 53.4 53.4
Putere kW 12.9 12.8 12.5 12.8 12.6 12.4 12.6 12.5 12.2
29.4
Totala kW 68.5 67.0 64.0 64.5 63.1 60.3 61.4 61.1 57.4
Sensib. kW 41.0 37.4 37.4 50.3 46.3 46.3 57.3 53.1 53.1
Putere kW 13.8 13.6 13.3 13.6 13.4 13.2 13.4 13.3 13.0
32.2
Totala kW 67.2 65.8 62.9 63.3 62.0 59.2 60.2 58.9 56.3
Sensib. kW 40.4 36.9 36.9 49.8 45.9 45.9 56.8 52.6 52.6
Putere kW 14.6 14.5 14.2 14.4 14.3 14.4 14.3 14.1 13.8
35.0
Totala kW 65.8 64.4 61.6 61.8 60.5 57.8 58.7 57.5 54.9
Sensib. kW 39.7 36.3 36.3 49.1 45.2 45.2 56.2 52.0 52.0
Putere kW 15.5 15.4 15.0 15.4 15.2 14.9 15.2 15.0 14.7
37.8
Totala kW 64.1 62.8 60.0 61.1 58.9 56.3 57.0 55.8 53.3
Sensib. kW 38.9 35.5 35.5 48.2 44.5 44.5 55.3 51.2 51.2
Putere kW 16.5 16.3 16.0 16.3 16.2 15.8 16.2 16.0 15.6
40.6
Totala kW 62.2 60.9 58.2 58.2 57.0 54.5 55.1 53.9 51.5
Sensib. kW 37.9 34.7 34.7 47.2 43.6 43.6 54.3 50.3 50.3
Putere kW 17.5 17.3 17.0 17.3 17.2 16.8 17.2 17.0 16.6
43.3
Totala kW 60.0 58.8 56.2 56.1 54.9 52.4 52.9 51.8 49.5
Sensib. kW 36.8 33.6 33.6 46.1 42.5 42.5 52.9 49.3 49.3
Putere kW 18.6 18.4 18.0 18.4 18.2 17.8 18.3 18.1 17.7
46.1
Totala kW 57.6 56.4 53.9 53.7 52.6 50.2 50.5 49.5 47.3
Sensib. kW 35.5 32.3 32.5 44.9 41.4 41.4 50.5 48.1 47.3
Putere kW 19.7 19.5 19.1 19.5 19.3 18.9 19.4 19.2 18.8
48.9
Totala kW 55.0 53.9 51.5 51.0 50.0 47.8 47.9 46.9 44.8
Sensib. kW 34.1 31.2 31.2 43.4 40.1 40.1 47.9 46.8 44.8
Putere kW 20.9 20.7 20.2 20.7 20.5 20.1 20.6 20.3 19.9
wbE - temperatura de intrare [n vaporizator, bulb umed
14
Date de performan\` pentru modelul - B300
Temperatura aer intrare [n vaporizator 26.7 oC bulb uscat
wbE* 21.7 oC 19.4 oC 17.2 oC
Debit aer mc/h 16311.6 13932 10875.6 16311.6 13932 10875.6 16311.6 13932 10875.6
Fact.cor. putere sens. 0.04 0.08 0.13 0.04 0.08 0.13 0.04 0.08 0.13
TE
MP
ER
AT
UR
A A
MB
IEN
T B
ULB
US
CA
T oC
23.9
Totala kW 94.6 91.7 88.1 89.3 86.6 83.2 86.1 83.2 80.2
Sensib. kW 57.9 50.7 50.7 70.0 62.1 62.1 79.0 70.6 70.6
Putere kW 17.0 16.7 16.4 16.7 16.4 16.1 16.4 16.1 15.8
26.7
Totala kW 92.7 89.9 86.3 87.4 84.8 81.4 84.2 81.7 78.4
Sensib. kW 56.9 49.9 49.9 69.0 61.3 61.3 78.0 69.7 69.7
Putere kW 17.9 17.7 17.3 17.6 17.4 17.0 17.3 17.1 16.7
29.4
Totala kW 90.6 87.8 84.4 85.3 82.7 79.4 82.1 79.6 76.4
Sensib. kW 55.8 49.0 49.0 67.9 60.4 60.4 76.9 68.8 68.8
Putere kW 18.9 18.7 18.3 18.6 18.4 18.0 18.4 18.1 17.7
32.2
Totala kW 88.2 85.6 82.2 82.9 80.4 77.2 79.7 77.3 74.2
Sensib. kW 54.7 48.0 48.0 66.7 59.3 59.3 75.8 67.8 67.8
Putere kW 20.0 19.7 19.3 19.7 19.4 19.1 19.4 19.1 18.8
35.0
Totala kW 85.6 83.1 79.8 80.3 77.9 74.8 77.1 74.8 71.8
Sensib. kW 53.4 46.9 46.9 65.5 58.2 58.2 74.5 66.7 66.7
Putere kW 21.2 20.8 20.4 20.9 20.6 20.2 20.6 20.3 19.9
37.8
Totala kW 82.9 80.4 77.1 77.6 75.2 72.2 74.4 72.1 69.2
Sensib. kW 52.1 45.7 45.7 64.2 57.1 57.1 73.2 65.5 65.5
Putere kW 22.4 22.0 21.6 22.1 21.7 21.3 21.8 21.5 21.0
40.6
Totala kW 79.8 77.4 74.3 74.5 72.3 69.4 71.3 69.2 66.4
Sensib. kW 50.6 44.5 44.5 62.7 55.8 55.8 71.3 64.3 64.3
Putere kW 23.6 23.3 22.8 23.3 23.0 22.6 23.1 22.7 22.3
43.3
Totala kW 76.6 74.3 71.3 71.3 69.1 66.4 68.1 66.0 63.4
Sensib. kW 49.1 43.2 43.2 61.2 54.5 54.5 68.1 63.0 63.0
Putere kW 25.0 24.6 24.1 24.7 24.3 23.8 24.4 24.0 23.6
46.1
Totala kW 73.1 70.9 68.1 67.8 65.7 63.1 64.6 62.7 60.2
Sensib. kW 47.5 41.8 41.8 59.5 53.1 53.1 64.6 61.6 60.2
Putere kW 26.4 26.0 25.5 26.1 25.7 25.2 25.8 25.4 24.9
48.9
Totala kW 69.4 67.3 64.6 64.1 62.2 59.7 60.9 59.1 56.7
Sensib. kW 45.7 40.3 40.3 57.8 51.6 51.6 60.9 59.1 56.7
Putere kW 27.8 27.4 26.9 27.5 27.1 26.6 27.3 26.8 26.3
wbE - temperatura de intrare [n vaporizator, bulb umed
15
Deb
itae
rm
c/h
Pres
iune
sta
tica
exte
rna
[Pa]
170
200
220
250
270
300
320
350
370
400
RPM
WRP
MW
RPM
WRP
MW
RPM
WRP
MW
RPM
WRP
MW
RPM
WRP
MW
6796
.865
015
2867
416
1869
817
1072
018
0374
118
9776
219
9378
220
9071
35.2
657
1601
681
1694
704
1788
726
1883
747
1980
767
2078
787
2177
7473
.666
516
7868
817
7371
018
6973
219
6775
320
6677
221
6679
122
6878
15.6
672
1758
695
1855
717
1954
738
2054
758
2156
778
2258
8154
.065
617
4367
918
4270
119
4272
320
4374
421
4576
422
4978
323
5484
92.4
663
1828
686
1929
708
2031
730
2135
750
2240
770
2346
789
2453
8834
.467
119
1769
420
2071
521
2573
622
3175
623
3877
624
4791
72.8
656
1905
679
2009
701
2115
723
2222
743
2300
763
2440
782
2551
9514
.866
419
9868
721
0570
922
1373
023
2375
024
3376
925
4578
826
5998
53.2
649
1988
673
2095
695
2205
716
2315
737
2427
757
2540
776
2654
1019
1.6
658
2086
681
2196
703
2308
724
2420
744
2535
764
2650
783
2767
P
erfo
rman
\a fu
nc\ie
de
debi
tul d
e ae
r -
B18
0
Tip
Act
ion
are
MP
ute
re m
oto
r W
37
28
.5F
ulie
Ven
tila
tor
BK
10
5H
Fu
lie M
oto
r1
VP
-56
Can
al F
ulie
12
34
56
Tu
ra\i
e rp
m7
89
76
47
36
708
67
96
52
Va
lorile
[n
gro
]ate
re
pre
zin
t` s
et`
rile
de
fa
bric`
Ale
ge
rea
altu
i ca
na
l de
fu
lie s
e f
ace
pe
ntr
u o
b\in
ere
a d
eb
itulu
i m
ed
iu la
pre
siu
ne
a s
tatic
` m
inim
` c
eru
t`.
Da
tele
din
ta
be
l su
nt
de
term
ina
te p
en
tru
cu
ren
t d
e a
er
orizo
nta
l cu
se
rpe
ntin
a
usc
at`
. P
en
tru
co
nd
i\iile
de
fu
nc\
ion
are
re
ale
ad
`u
ga
ti p
ierd
-e
rile
de
pre
siu
ne
din
ta
be
lul d
e m
ai j
os.
Pie
rder
i de
pre
siu
ne
pe
com
po
nen
te -
B18
0
Deb
it a
er m
c/h
67
96
.87
13
5.2
74
73
.67
81
5.6
81
54
.08
49
2.4
88
34
.491
78
.29
51
4.8
98
53
.21
019
1.6
Pie
rder
e d
e p
resi
un
e -
Pa
Ser
pen
tin
` u
med
`0
10
20
30
30
40
50
60
60
70
80
Flu
x d
esce
nd
ent
10
10
10
10
10
10
10
10
10
10
10
Flu
x d
esce
nd
ent
Eco
no
miz
or
RA
Cla
pet
a d
esch
isa
20
20
20
20
20
20
20
30
30
30
30
Flu
x o
rizo
nta
l Eco
no
miz
or
RA
Cla
pet
a d
esch
isa
00
00
00
00
01
01
0G
ril`
co
nce
ntr
ic`
RX
RN
-AD
80 s
au R
XR
N-A
D81
]i
Ple
nu
m R
XM
C-C
J07
10
20
30
40
50
60
70
80
90
10
01
10
Fac
tori
de
core
ctie
fu
nc\
tie
de
deb
itu
l de
aer
- B
180
Deb
it a
er m
c/h
67
96
.87
13
5.2
74
73
.67
81
5.6
81
54
.08
49
2.4
88
34
.49
17
8.2
95
14
.898
53
.21
01
91
.6P
ute
re t
ota
l`0
.96
0.9
70
.97
0.9
80
.99
1.0
01
.00
1.0
11
.02
1.0
21.0
3P
ute
re s
ensi
bil`
0.8
50
.88
0.9
10
.93
0.9
60
.99
1.0
11
.04
1.0
71
.10
1.1
2P
ute
re a
bso
rbit
`0
.98
0.9
90
.99
0.9
91
.00
1.0
01
.00
1.0
11
.01
1.0
11.0
2
16
Deb
itae
rm
c/h
Pres
iune
sta
tica
exte
rna
[Pa]
100
120
150
170
200
220
250
270
300
320
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
8492
.466
719
1269
420
4572
121
8074
723
1877
424
5988
34.4
675
1994
702
2129
728
2267
754
2407
780
2550
9172
.868
420
8371
022
2173
623
6176
225
0378
726
4895
14.8
667
2043
692
2180
718
2320
744
2462
769
2607
795
2754
9853
.267
621
4470
122
8472
724
2675
225
7077
727
1710
191.
668
522
5371
123
9573
625
3976
026
8678
528
3510
533.
667
022
2769
523
6972
025
1374
526
5976
928
0979
329
6010
872.
068
123
4870
524
9273
026
3875
427
8777
829
3911
210.
466
723
3369
124
7671
626
2374
027
7176
329
2278
730
7611
552.
467
824
6670
226
1272
627
6075
029
1177
330
6511
890.
866
624
6169
026
0771
327
5573
729
0676
030
5978
332
1512
232.
867
826
0670
227
5472
529
0574
030
5877
132
1379
333
7212
571.
266
826
1169
127
5971
429
1073
630
6275
932
1878
233
75
P
erfo
rman
\a f
un
c\ie
de
deb
itu
l de
aer
- B
240
Tip
Act
ion
are
MP
ute
re m
oto
r W
55
92
.7F
ulie
Ven
tila
tor
BK
13
0H
Fu
lie M
oto
r1
VP
-71
Can
al F
ulie
12
34
56
Tu
ra\i
e rp
m7
83
75
97
36
713
69
06
66
Va
lorile
[n
gro
]ate
re
pre
zin
t` s
et`
rile
de
fa
bric`
Ale
ge
rea
altu
i ca
na
l de
fu
lie s
e f
ace
pe
ntr
u o
b\in
ere
a d
eb
itulu
i m
ed
iu la
pre
siu
ne
a s
tatic
` m
inim
` c
eru
t`.
Da
tele
din
ta
be
l su
nt
de
term
ina
te p
en
tru
cu
ren
t d
e a
er
orizo
nta
l cu
se
rpe
ntin
a
usc
at`
. P
en
tru
co
nd
i\iile
de
fu
nc\
ion
are
re
ale
ad
`u
ga
ti p
ierd
-e
rile
de
pre
siu
ne
din
ta
be
lul d
e m
ai j
os.
Pie
rder
i de
pre
siu
ne
pe
com
po
nen
te -
B24
0D
ebit
aer
mc/
h8
49
2.4
88
34
.49
17
2.8
95
14
.89
85
3.2
10
19
1.6
10
53
3.6
10
87
2.0
11
21
0.4
11
55
2.4
11
89
0.8
12
23
2.8
12
57
1.2
Ser
pen
tin
` u
med
`0
00
00
00
00
00
00
Flu
x d
esce
nd
ent
10
10
10
10
10
10
10
10
10
20
20
20
20
Flu
x d
esce
nd
ent
Eco
no
miz
or
RA
Cla
pet
a d
esch
isa
20
20
30
30
30
30
30
40
40
40
40
40
50
Flu
x o
rizo
nta
l Eco
no
miz
or
RA
Cla
pet
a d
esch
isa
00
00
10
10
10
10
10
10
10
10
20
Gri
l` c
on
cen
tric
` R
XR
N-A
D80
sau
RX
RN
-AD
81 ]
i P
len
um
RX
MC
-CJ0
76
07
08
09
01
00
11
01
10
12
01
30
14
01
50
16
01
70
Gri
l` c
on
cen
tric
` R
XR
N-A
D86
]i P
len
um
RX
MC
-CK
08N
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/A8
09
09
01
00
Fac
tori
de
core
ctie
fu
nc\
tie
de
deb
itu
l de
aer
- B
240
Deb
it a
er m
c/h
84
92
.48
83
4.4
91
72
.89
51
4.8
98
53
.21
01
91
.61
05
33
.61
08
72
.01
12
10
.41
15
52
.41
18
90
.81
22
32
.81
25
71
.2P
ute
re t
ota
l`0
.96
0.9
60
.97
0.9
70
.98
0.9
80
.99
0.9
91
.00
1.0
01
.01
1.0
21
.02
Pu
tere
sen
sib
il`0
.83
0.8
50
.87
0.9
00
.92
0.9
40
.96
0.9
81
.00
1.0
21
.04
1.0
61
.08
Pu
tere
ab
sorb
it`
0.9
80
.98
0.9
90
.99
0.9
90
.99
1.0
01
.00
1.0
01
.00
1.0
11
.01
1.0
1
17
Tip
Act
ion
are
MP
ute
re m
oto
r W
7457.0
Fu
lie V
enti
lato
rB
K120H
Fu
lie M
oto
r1V
P-7
5C
anal
Fu
lie1
23
45
6T
ura
\ie
rpm
903
879
853
828
803
777
Valo
rile
[ngro
]ate
repre
zint`
set`
rile
de f
abric`
Ale
gere
a a
ltui c
anal d
e f
ulie
se f
ace
pentr
u o
b\in
ere
a d
eb
itulu
i m
ediu
la p
resi
unea s
tatic
` m
inim
` c
eru
t`.
Date
le d
in t
ab
el
sunt
dete
rmin
ate
pentr
u c
ure
nt
de a
er
orizo
nta
l cu s
erp
en
tina
usc
at`
. P
entr
u
condi\i
ile d
e f
unc\
ionare
reale
ad`ugati
pie
rd-
erile
de p
resi
une d
in t
abelu
l de m
ai j
os.
Pie
rder
i de
pre
siu
ne
pe
com
po
nen
te -
B30
0D
ebit
aer
mc/
h10872.0
11210.4
11552.4
11890.8
12232.8
12571.2
129
09
.61
32
51
.61
35
90
.01
39
28
.41
42
70
.41
46
08
.81
49
50
.81
52
89
.21
56
27
.61
59
69
.61
63
08
.0S
erp
enti
n`
um
ed`
00
10
10
10
10
10
10
20
20
20
20
20
30
30
30
30
Flu
x d
esce
nd
ent
10
10
20
20
20
20
20
30
30
30
30
40
40
40
50
50
50
Flu
x d
esce
nd
ent
Eco
no
miz
or
RA
Cla
pet
a d
esch
isa
40
40
40
40
40
50
50
50
50
60
60
60
60
70
70
70
70
Flu
x o
rizo
nta
l Eco
no
miz
or
RA
Cla
pet
a d
esch
isa
10
10
10
10
10
20
20
20
20
20
20
20
30
30
30
30
30
Gri
l` c
on
cen
tric
` R
XR
N-A
D80
sau
RX
RN
-AD
81 ]
i P
len
um
RX
MC
-Ck0
860
70
80
90
90
100
11
01
20
12
01
30
14
01
50
15
01
60
17
01
80
19
0
Gri
l` c
on
cen
tric
` R
XR
N-A
D80
sau
RX
RN
-AD
81 ]
i P
len
um
RX
MC
-CL
09N
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/A8
09
01
00
11
0
Fac
tori
de
core
ctie
fu
nc\
tie
de
deb
itu
l de
aer
- B
300
Deb
it a
er m
c/h
10872.0
11210.4
11552.4
11890.8
12232.8
12571.2
12909.6
13251.6
13590.0
13928.4
14
27
0.4
14
60
8.8
14
95
0.8
15
28
9.2
15
62
7.6
15
96
9.6
16
30
8.0
Pu
tere
to
tal`
0.9
60.9
60.9
7097
0.9
80.9
80.9
90.9
91.0
01.0
01
.00
1.0
11
.01
1.0
21
.02
1.0
31
.03
Pu
tere
sen
sib
il`0.8
50.8
70.8
80.9
00.9
20.9
40.9
50.9
70.9
91.0
01
.02
1.0
41
.06
1.0
71
.09
1.1
11
.12
Pu
tere
ab
sorb
it`
0.9
80.9
80.9
80.9
90.9
90.9
90.9
91.0
01.0
01.0
01
.00
1.0
01
.01
1.0
11
.01
1.0
11
.01
De
bit
ae
rm
c/h
Pres
iune
sta
tica
exte
rna
[Pa]
5070
100
120
150
170
200
220
250
270
300
320
350
370
400
420
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
RPM
WR
PMW
10872.0
795
3180
815
3306
835
3427
854
3544
872
3658
890
3768
11210.4
784
3180
805
3310
825
3436
844
3557
862
3676
881
3790
898
3901
11552.4
795
3316
815
3447
834
3573
853
3696
871
3815
889
3929
906
4041
11890.8
785
3326
805
3460
825
3591
844
3718
862
3842
880
3961
897
4077
12232.8
796
3476
816
3612
835
3743
853
3871
871
3995
889
4115
906
4231
12571.2
787
3495
807
3635
826
3771
845
3903
863
4031
881
4156
898
4277
12909.6
798
3660
818
3801
837
3937
855
4070
873
4199
890
4325
13251.6
790
3688
809
3833
829
3974
847
4112
865
4245
882
4375
899
4501
13590.0
802
3868
821
4014
840
4156
858
4294
875
4428
892
4558
13928.4
794
3906
813
4056
832
4202
851
4345
868
4483
886
4618
902
9749
14270.4
787
3946
806
4100
825
4251
844
4398
862
4541
879
4680
896
4816
14608.8
800
4147
819
4303
837
4454
855
4601
873
4745
890
4885
14950.8
793
4197
812
4356
831
4512
849
4664
867
4812
884
4957
901
5097
15289.2
787
4249
806
4413
825
4573
844
4729
861
4882
879
5031
895
5176
15627.6
800
4472
820
4636
838
4797
856
4954
873
5108
890
5257
15969.6
795
4533
814
4702
833
4868
851
5029
869
5187
886
5341
902
5491
16308.0
790
4597
809
4771
828
4941
846
5106
864
5269
881
5427
898
5581
P
erf
orm
an
\a f
un
c\i
e d
e d
eb
itu
l d
e a
er
- B
30
0
18
Date electrice
19
Dimensiuni
20
21
MASE
Accesorii Brut kg Net kg
Economizor - jet vertical 70.31 66.22
Economizor - jet orizontal 74.80 70.31
Clapet` aer proasp`t manual 23.13 18.14
Clapet` aer proasp`t motorizat` 20.87 74.39
Soclu montaj 14” 77.11 74.39
Putere kW % Dispunere greutate
52.8 - 87.9A B C D
32% 27% 16% 24%
22
Spa\ii libere necesare [n jurul locului de instalare
Spatiu [mm] Zona2032 A457 B457 C457 D
1524 E
23
Accesorii Accesorii ce se instaleaz` la locul de montaj
Accesoriu CODMas` brut`
kgMas` net`
kgInstalat
de fabric` ?Termostat vezi mai jos NUEconomizor cu 1 senzor entalpic, pentru jet vertical RXRD-PGCM3 125.6 76.2 DAEconomizor cu 1 senzor entalpic, pt. jet vertical + detector de fum
RXRD-SGCM3 127.0 77.6 DA
Kit upgrade la economizor cu 2 senzori entalpici RXRX-AV02 0.5 0.2 NUEconomizor cu 1 senzor entalpic, pentru jet lateral RXRD-RGCM3 151.0 36.5 NUSenzor CO2 cu montaj mural pentru conectare la econo-mizor
RXRX-AR02 1.4 0.9 NU
Registru de reglaj manual aer proaspat cu montaj pe latura scurta
RXRF-KFA1 27.7 23.6 NU
Servomotor pentru RXRF-KFA1 RXRX-AW03 19.1 15.9 NUSoclu de montaj roof-top pe terasa, cu rol de etansare (Roofcurb), cu inaltimea de 35cm
RXKG-CBH14 83.5 79.8 NU
Adptor soclu montaj pt. RXRK-E56 RXRX-CJCE56 210.9 88.2 NUAdptor soclu montaj pt. RXKG-CAF14 RXRX-CJCF14 251.7 29.1 NUDifuzor concentric cu introducere pe orizontala si evacuare pe verticala pentru modelul SKNL-B180NM si SKNLB180NM29E
RXRN-AD81 140.6 71.2 NU
Difuzor concentric cu introducere pe orizontala si evacu-are pe verticala pentru modelul SKNL-B240NM si SKNL-B240NM33E
RXRN-AD86 166.5 96.2 NU
Difuzor concentric cu introducere pe orizontala si evacu-are pe verticala pentru modelul SKNL-B300NM si SKNL-B300NM39E
RXRN-AD88 186.0 67.8 NU
Difuzor concentric cu introducere si evacuare la fata plafonului pentru modelul SLNL-B180NM si SKNLB180NM29E
RXRN-AD80 96.6 52.2 NU
Plenum de conectare roof-top la tubulatura rectangulara pentru modelul SKNL-B180NM si SKNLB180NM29E
RXMC-CJ07 36.7 33.6 NU
Plenum de conectare roof-top la tubulatura rectangulara pentru modelul SKNL-B240NM si SKNL-B240NM33E
RXMC-CK08 36.7 33.6 NU
Plenum de conectare roof-top la tubulatura rectangulara pentru modelul SKNL-B300NM si SKNL-B300NM39E
RXMC-CL09 36.7 33.6 NU
Kit de functionare la temperaturi scazute (1 pentru fiecare compresor)
RXRZ-C02 1.4 0.9 DA
Kit pentru pornire la temperaturi scazute RXRX-AM03 0.5 0.2 DAPriza aditionala RXRX-AN01 0.9 0.7 DA
Termostate
24
EconomizoareRXRD-PGCM3 - Economizor cu semnal de la 1 senzor entalpic, pentru conectarea tubulatur-ilor pe dedesubtRXRD-SGCM3 - Economizor cu semnal de la 1 senzor entalpic, pentru conectarea tubulatur-ilor pe dedesubt + detector de fumRXRX-AV02 - Kit de upgrade la economizor cu 2 senzori entalpiciRXRX-AR02 - Senzor de dioxid de carbon cu montaj mural pentru conectare la economizor
- controloare Honeywell;- accesorii disponibile instalate din fabric` sau la locul de montaj;- motoare de actionare direct` clapete;- modulare 0-100%;- clapete etan]e;- instalare u]oar`;- conectori electrici cu 12 pini polarizati;- preconfigurat - nu sunt necesare reglaje la locul de montaj;- clapeta comandat` barometric [n configura\ie standard;- posibilitate de upgrade la senzor cu dou` semnale entalpice;- posibilitate de montaj senzor de CO2;- economizor complet pentru aplicatie cu jet vertical;- optional comanda la distan\`;- posibilitate de a monta, [n teren un evacuator de putere.
25
Economizor pentru duct orizontal
RXRD-RGCM3 - Economizor cu 1 senzor entalpic, pentru jet lateralRXRX-AV02 - Kit upgrade la economizor cu 2 senzori entalpiciRXRX-AR02 - Senzor CO2 cu montaj mural pentru conectare la economizor
- controloare Honeywell;- accesorii disponibile instalate din fabric` sau la locul de montaj;- motoare de actionare direct` clapete;- modulare 0-100%;- clapete etan]e;- instalare u]oar`;- conectori electrici cu 12 pini polarizati;- preconfigurat - nu sunt necesare reglaje la locul de montaj;- clapeta comandat` barometric [n configura\ie standard;- posibilitate de upgrade la senzor cu dou` semnale entalpice;- posibilitate de montaj senzor de CO2;- economizor complet pentru aplicatie cu jet vertical;- optional comanda la distan\`;- posibilitate de a monta, [n teren un evacuator de putere.
26
Clapet` aer proasp`t
RXRX-AW03 - servomotor pentru clapet` aer proasp`t
RXRF-KF1 - clapeta actionat` manual pentru admisie aer proasp`t RXRX-AW03 - servomotor pentru clapet` aer proasp`t
27
Soclu de montaj- soclurile de montaj pot fi utilizate pentru toate modelele;- o singura [nal\ime 356 mm;-asamblare rapid`;- sisteme de prindere de 25.4 mm x 102 mm livrate;- nu sunt necesare panouri izolate;- se livreaz` garnitur` de etan]are de 711 mm odata cu soclul.
Asamblarea solului de montaj
28
Adaptor soclu de montajModele vechi Model vechi Adaptor soclu Model nouCabinet comercial -------> RXRK-E56 -------> RXRX-CJCE56 -----------> KNLRCF, RGF, REF
Cabinet comercial -------> RXKG-CAF14 -------> RXRX-CJCF14 -----------> KNLKKB, KMB, KNB
29
Instalare cu difuzor concentric
Adaptoare flux vertical RXMC-CJ07 - pentru SKNL-B 180 utilizat cu RXRN-AD80 ]i RXRN-AD81
30
RXMC-CK08 pentru SKBL-B 240 utilizat cu RXRN-AD86
RXMC-CL09 pentru SKBL-B 300 utilizat cu RXRN-AD88
31
Difuzor concentric RXRN-AD80 FLUSHSKNL-B 180
- difuzor din aluminiu cu cutie de aer retur din aluminiu;- cu garnitur` anti-transpira\ie;- suport din fibr` de sticl`;- supor\i de ag`\are;- cutie difuzor din tabl` de o\el izolat` cu 2.54 mm izola\ie de 0.7 kg/m.
COD Debitmc/h
Presiune statica
Sec\iune Viteza la guler
Viteza jetului
RXRN-AD80
9514.8 0.36 28 - 37 1000 2082
9853.2 0.39 29 - 38 1036 2156
10195.2 0.42 40 - 50 1071 2230
10533.6 0.46 42 - 51 1107 2308
10872.0 0.50 43 - 52 1143 2379
11214.0 0.54 45 - 56 1179 2454
32
Difuzor concentric RXRN-AD81 STEP DOWNSKNL-B 180
- difuzor din aluminiu cu cutie de aer retur din aluminiu;- cu garnitur` anti-transpira\ie;- suport din fibr` de sticl`;- supor\i de ag`\are;- cutie difuzor din tabl` de o\el izolat` cu 2.54 mm izola\ie de 0.7 kg/m.- difuzoare cu deflec\ie dubl` cu lamelele securizate cu arc de o\el.
COD Debitmc/h
Presiune statica
Sec\iune Viteza la guler
Viteza jetului
RXRN-AD81
9514.8 0.36 39 - 49 920 920
9853.2 0.39 42 - 51 954 954
10195.2 0.42 44 - 54 1022 1022
10533.6 0.46 45 - 55 1056 1056
10872.0 0.50 46 - 55 1090 1090
11214.0 0.54 47 - 56 1124 1124
33
Difuzor concentric RXRN-AD86 STEP DOWNSKNL-B 240
- difuzor din aluminiu cu cutie de aer retur din aluminiu;- cu garnitur` anti-transpira\ie;- suport din fibr` de sticl`;- supor\i de ag`\are;- cutie difuzor din tabl` de o\el izolat` cu 2.54 mm izola\ie de 0.7 kg/m.- difuzoare cu deflec\ie dubl` cu lamelele securizate cu arc de o\el.
COD Debitmc/h
Presiune statica
Sec\iune Viteza la guler
Viteza jetului
RXRN-AD86
12232.8 0.39 33 - 38 827 827
12571.2 0.41 35 - 40 850 850
12913.2 0.43 36 - 41 873 873
13251.6 0.47 38 - 43 896 896
13593.6 0.50 39 - 44 918 918
13932.0 0.53 41 - 46 941 941
14270.4 0.56 43 - 49 964 964
14612.4 0.59 44 - 50 987 987
14950.8 0.63 47 - 55 1010 1010
34
Difuzor concentric RXRN-AD88 STEP DOWNSKNL-B 300
- difuzor din aluminiu cu cutie de aer retur din aluminiu;- cu garnitur` anti-transpira\ie;- suport din fibr` de sticl`;- supor\i de ag`\are;- cutie difuzor din tabl` de o\el izolat` cu 2.54 mm izola\ie de 0.7 kg/m.- difuzoare cu deflec\ie dubl` cu lamelele securizate cu arc de o\el.
COD Debitmc/h
Presiune statica
Sec\iune Viteza la guler
Viteza jetului
RXRN-AD86
16988.4 0.51 46 - 54 907 907
17838.0 0.58 50 - 58 953 953
18687.6 0.65 53 - 61 998 998
19537.2 0.73 55 - 64 1043 1043
20386.8 0.82 58 - 67 1089 1089
21232.8 0.91 61 - 71 1134 1134
22082.4 1.00 64 - 74 1179 1179
35
Specifica\ii mecanice Izola\ie echipament1. Suprafe\ele interioare ale cabinei trebuie s` fie izolate cu izola\ie pe baz` de fibr` de sticl` cu folie de aluminiu cu o grosine minim` de 20 mm ]i densitate specific` de 0.5 -0.7 kg/m;2. Izola\ia trebuie s` fie antifoc conform cerin\elor NEFPA 90A.
Termostate1. trebuie s` activeze “G” la cererea de [nc`lzire;2. trebuie s` activeze dou` trepte at@t pentru r`cire c@t ]i pentru [nc`lzire;3. trebuie s` aib` capacitatea de a fi programabile func\ie de timp.
Electric` ]i control electronic Generalita\i1. Instala\ia electric` trebuie s` fie complet` cu circuit electric de joas` tensiune protejat de siguran\` electric` resetabil` de 24 V;2. Firele electrice trebuie s` fie colorate diferit;3. Schimb`torul de c`ldur` trebuie s` fie controlat electronic de un microprocesor;4. Unitatea trebuie s` includ` cel putin un terminal cu 9 pini pentru controlul cablajului.
Siguran\`1. Siguran\` la supratemperatur` ]i supracurent compresor;2. Presostat de minim` presiune;3. Presostat de presiune mare;4. Resetare automata a protec\iei pentru supratemperatur` motor;5. Sec\iunea de [nc`lzire trebuie s` aib` minimum urm`toarele protec\ii: - limitatoare de supratemperatur`; - presostat motor prev`zut din proiect; - [ntreruptor de flac`r`; - controlor prezen\` flac`r`
Sec\iunea de filtrare standard:1. Filtrul trebuie instalat de fabric`, s` fie de vitez` mic`, grosime de 5 cm din fibr` de sticl`;2. Toate filtrele trebuie s` aibe aceea]i dimensiune;3. Viteza la suprafa\a filtrului nu trebuie s` dep`]easc` 365 fpm la debitul max. de aer;4. Accesul la filtre trebuie s` se fac` printr-un panou din cabina unit`\ii.
Condi\ionare aer Generalita\i1. Rooftop montat [n exterior, conectat electric, unitate mixta [nc`lzire ]i r`cire ce utilizeaz` un compresor scroll ermetic pentru r`cire ]i un arz`tor pentru [nc`lzire;2. Unitatea rooftop este asamblat` de fabric` intr-un singur tot. Trebuie echipat` si testat` in fabric` cu tot ce este necesar ca dup` mmontaj s` func\ioneze f`r` alte adaosuri;3. Unitatea trebuie s` nu d`uneze mediului, refrigerent de tip R410;4. Unitatea trebuie s` fie montat` cu respectarea instruc\iunilor produc`torului;5. Unitatea trebuie sa fie instalat` cu respectarea legisla\iei locale [n vigoare.
Asigurarea Calit`\ii1. Unitatea trebuie s` respecte eficien\a minim` cerut` de legisla\ia [n vigoare;2. unit`\ile trifazate [ndeplinesc cerin\ele Energy Star;3. Unitatea trebuie sa fie certificata in raport cu standardele specifice in vigoare;4. proiectarea unit`\ii trebuie s` respecte standardele specifice [n vigoare;
36
5. unitatea trebuie testat` ]i certificat`conform legisla\iei [n vigoare;6. izola\ia ]i adezivul utilizat pentru aceasta trebuie s` fie rezistente la foc a]a cum prevede legisla\ia [n domeniu aflat` [n vigoare;7. Carcasa unit`\ii trebuie s` reziste la coroziune cel pu\in 500 de ore la stropirea cu ap` s`rat`;8. Carcasa unit`\ii trebuie s` trec` cu bine testul de 5000 de ore de stropire cu ap` s`rat`, metoda 6061;9. Unitatea trebuie proiectat` ]i produs` [n regim de management al calit`\ii conform cu ISO 9001:2008;10. Soclul de montaj trebuie proiectat conform normelor specfice [n vigoare;11. Unitatea trebuie testat` pe linia de asamblare automat`. Rezultatele testelor trebuie p`strate de fabric` ]i trebuie s` poat` fi u]or accesate la cerere;12. unitatea trebuie s` fie proiectat` [n conformitate cu standard-ul UL 1995;13. unitatea trebuie s` fie realizat` astfel [nc@t z`pada s` nu poat` p`trunde [n unitatea de control nici la o vitez` a v@ntului de 60 km/h.
Transport, depozitare, manipulare1. Unitatea trebuie manipulat` ]i depozitat` conform specifica\iilor produc`torului;2. Dac` este ridicat` cu macaraua, sunt necesare panouri de protec\ie ]i elemente de distan\are a cablurilor de ridicare;3. Depozitarea unit`\ii se va face numai [n pozi\ie vertical`.
Proiectare1. conform specifica\iilor clientului.
Caracteristici de operare1. unitatea trebuie s` fie capabil` s` porneasc` ]i s` func\ioneze la 46 oC, temperatur` am-bient, s` poat` func\iona alimentat` cu tensiunea desemnata de fabricant ± 10%.2. compresorul, cu dotarea standard trebuie s` fie capabil s` func\ioneze sub temperatura de +4 oC, temperatura ambient. Accesoriile pentru temperatur` joas` trebuie s` fie necesare pentru o temperatur` ambiental` de sub +4 oC.3. unitatea trebuie s` fie capabil` s` distribue aer vertical ]i lateral;4. unitatea trebuie configurat` din fabric` pentru distribu\ie vertical` de aer ]i preluare retur;5. unitatea trebuie s` fie convertibil` pe teen din distribu\ie vertical` [n cea orizontal`.
Cabina unit`\ii1. trebuie construit` din o\el galvanizat ]i vopsit` rezistent pe toate suprafe\le [n contact cu mediul;2. vopseaua suprafe\ei exterioare a cabinei trebuie depus` [ntr-un film de grosime minim` de 0.00762 mm, duritate 60 grd;3. suprafata interioara trebuie izolat` cu vata de sticl` de grosime minim` 20 mm si densitate specific` 0.5 - 0.7 kg/m, cu folie de aluminiu pe partea de aer;4. ]asiul unit`\ii trebuie s` aibe loca]uri pentru trecerea firelor de alimentare electric`;5. }asiula. trebuie s` fie alc`tuit din ]in` metalic` pe toate laturile;b. trebuiesc prev`zute g`uri de prindere ]i manevrare;c. gaurile trebuiesc prev`zute la baza ]asiului pentru a facilitan desc`rcarea din camion;d. ]asiul trebuie s` aibe o [n`l\ime minim` de 14 inch.
T`vi\a de condens ]i conexiunia. tavi\a de condens trebuie produs` din material rezistent la coroziune ]i s` aib` pant` de golire;
37
b. trebuie s` respect specifica\iile standardelor [n vigoare;c. trebuie s` fie dotat` cu un conector pentru golire de 1: sau de 1 1/2”. Dimensiunea conec-torului trebuie s` fie recomandat` de produc`tor.
Conexiunea la gaza. toate conductele de alimentare cu gaz combustibile trebuie s` intre [n cabina ma]iniipe aceea]i parte;b. caracteristici ale ]asiului: - unitatea standard trebuie s` aibe o portiune deasupra ]asiului g`urita pentru a intra teava de alimentare cu gaz; - nu trebuie mic]orat` rezisten\a mecanic` a ]asiului prin g`urirea pentru a permite accesul gazului metan.
Conexiuni electricea. toate cablurile de alimentare electric` trebuie s` intre [n cabinetul unit`\ii printr-o singur` intrare;b. caracteristici ale ]asiului: - unitatea standard trebuie s` aibe o portiune deasupra ]asiului g`urita pentru a intra teava de alimentare electric`; - nu trebuie mic]orat` rezisten\a mecanic` a ]asiului prin g`urirea pentru a permite accesul conductorilor electrici.
Panourile de accesa. panourile de acces trebuie s` poata fi demontate u]or pentru a permite accesul;b. balamalele din o\el inox trebuie s` fie standard pentru toate u]ile;c. panourile de acoperire a unit`\ii de control, ventilatoarelor interne, ventilatoarelor motoare-lor ]i a elementelor instala\iei de gaz, trebuie s` aib` un sfert de rota\ie oarb`.
{nc`lzirea pe gaz 1. Generalit`\ia. schimb`torul de c`ldur` trebuie s` fie rezultatul unui proiect. In proiectare nu se va consid-era un schimb`tor de c`ldur` cu presiune pozitiv`;b. sistemul trebuie s` cuprind` un sistem de aprindere cu sc@nteie ]i o valv` de gaz cu modulare;c.schimb`torul de c`ldur` trebuie s` permita evacuarea gravita\ional` a condensului, mentenan\a pentru evacuarea condensului trebuie s` nu fie necesar`;d. presiune de alimentare a gazului la intrarea [n unitate trebuie s` fie cea cerut` de produc`tor.
2. Func\ionarea schimb`torului de c`ldur` trebuie s` fie controlat` de un microproce-sor.a. ecranul controlorului trebuie s` afi]eze prin intermediul LED-urilor sau LCD erorile de func\ionare.
3. Construc\ia standard a schimb`torului de c`ldur`a. schimb`torul de c`ldur` trebuie s` fie, pe sectiunea tubular`, construit din otel protejat la coroziune cu aripioare din aluminiu;b. arz`toarele trebuie s` fie monobloc din o\el acoperit cu aluminiu;c. arz`toarele standard trebuie s` aib` duzele calibrate s` func\ioneze la o altitudine de 610 metri, pentru altitudini mai mari trebuie s` existe un kit care s` permit` func\ionarea corect` a arz`torului.
38
4. Schimb`tor de c`ldur` op\ional din o\el inoxa. trebuie s` utilizeze sisteme de recuperare a c`ldurii ]i un sistem de aprindere direct` cu sc@nteie;b. s` utilizeze o van` de gaz modulant`;c. arz`toarele trebuie s` fie monobloc;d. toate conductele de alimentare cu gaz trebuie s` intre [n cabinetul unit`\ii printr-un singur loc;e. schimb`torul de c`ldur` din otel inox trebuie s` fie construit din inox tip 409;f. tuburile si antecamera schimb`torului trebuie s` fie construite din inox 409;g. un schimb`tor complet din inox asigur` o flexibilitate mai mare [n aplica\ii.
5. Ventilatoarele ]i motoarele pentru inducerea curentului de aera. ventilatoarele trebuie s` fie centrifugale, cu o singur` intrare ]i actionate direct de motor;b. trebuiesc executate din o\el cu protec\ie anticoroziune;c. trebuie s` aibe lag`re etan]e lubrefiate permanent;d. motoarele trebuie s` aiba protec\ie la supra[nc`rcare;e. trebuie s` aibe posibilitatea reset`rii automate a protectiei.
Schimb`toarele de c`ldur` (pe linia de r`cire)a. evaporatorul ]i condensatorul trebuiesc construite din \eav` de cupru cu aripioare de alu-miniu brazate pe \eava de cupru;b. evaporatorul si condensatorul trebuiesc testate la 10 bar pentru etan]are, 38 bar test de presiune ]i test de spargere la 151 bar.
Elementele de pe linia de refrigerenta. robinetele de expansiune termic` trebuie s` aiba orificiu tip distribuitor;b. trebuie s` existe filtru usc`tor pentru refrigerent;c. conectori pentru manometre pe aspira\ie ]i pe refulare;d. pe panourile frontale ]i posterioare trebuie s` existeloca]uri pentru manometre.
Compresoarelea. pentru fiecare circuit independent de refrigerent trebuie s` existe un compresor scroll er-metic;b. motorul compresorului trebuie s` fie r`cit de refrigerentul gazos care s` treac` printre spire;c. compresorul trebuie s` fie dotat cu protec\ie la temperaturi ambientale mari;d. compresorrul trebuie s` fie dotat cu protec\ii la supra[nc`rcare, supratemperatur` ]i la dep`]irea amperajului maxim;e. compresorul trebuie montat din fabric` pe amortizoare din cauciuc;f.rezisten\ele din carter nu trebuie s` func\ioneze [n timpul func\ion`rii normale a compresoru-lui.
Filtre1. accesul la filtre deja a fost specificat [n acest capitol;2. filtrele trebuie s` aiba rama sa poata fi u]or demontate ]i [nlociute;3. filtrele trebuie s` fie instalate de fabric` ]i sa [ndeplineasc` conditiile deja stabilite [n acest capitol;4. viteza la suprafata de filtrare nu trebuie s` dep`]easca 365 fpm la debitul maxim de aer;
Ventilatoare evaporatora. trebuie sa aiba ungere permanent`;b. trebuie se aiba protectie termica resetabila automat
39
c. trebuie sa poata function continuu, nu trebuie montat nici un sistem de control suplimentar care sa [mpiedice func\ionarea continu`.
Ac\ionarea prin curea a ventilatorului pe evaporator:a. trebuie s` includ` fulie ajustabila pe motor;b. trebuie s` aibe lag`r cu ungere permanent`;c. ventilatorul trebuie s` fie de tipul cu dou` intr`ri cu pale curbate [nainte;d. ventilatoarele trebuie s` fie construite din o\el protejat la coroziune ]i s` fie echilibrate dinamic.
Ventilatoarele de pe condensator Motoarele:a. trebuie s` fie capsulate;b. sa aibe lag`re lubrefiate permanent;c. trebuie s` aibe protec\ie termic` resetabil` automat;d. trebuie s` fie de tipul:”shaft-down”.
Ventilatoarele:a. sa fie ac\ionate direct de motor;b. trebuie s` aibe palele din otel protejat la coroziune ]i s` fie echilibrate dinamic.
Dot`ri speciale1. Economizoare integrate:a. actionareparalel`, modulat` a palelor pentru a fi capabil simultan s` opereze [n compri-mare ]i economic;b. module independente pentru retur aer orizontal ]i vertical. Modulul vertical trebuie s` fie standard din fabric`;c. clapetele trebuie s` fie galvanizate cu ac\ionare metalic`. Nu sunt acceptate clapete din plastic;d. trebuie s` con\in` toat` dotarea necesar` ca unitatea s` poat` func\iona [n regim de r`cire liber` atunci c@nd condi\iile ambientale permit;e. trebuie s` aiba clapete motorizate pentru intrare aer din exterior ]i pentru aerul de retur pentru controlul pozitiv al curentului de aer;f. trebuie s` fie capabil` s` introduc` 100% aer din exterior;g. tebuie s` aib` clapet` cu control barometric capabil` s` elibereze [n atmosfer` 100% aeru de retur;h. trebuie s` fie echipat` cu clapet` ce se [nchide automat (cu arc) pentru situa\iile [n care se dore]te economie energetic`;i. un senzor de exterior entalpic trebuie s` existe ca dotare standard. Senzorul entalpic trebuie s` aibe posibilitatea de setare a parametrilor ]i trebuie s` existe posibilitatea mont`rii de senzori suplimentari;j. controlerul economizorului trebuie s` controleze ]i accesoriile pentru eliberarea puterii [n atmosfer`. Domeniul setat de fabric` trebuie s` fie de 70% cu un domeniu de lucru de 0 la 100%;k. economizorul trebuie s` mentin` minimum debit de aer in cladire [n perioad` de minim` ocupare ]i s` permit` un mod de ventilare pentru perioada de maxim` ocupare;l. controlerul economizorului trebuie s` accepte o intrare de 2 - 10 V curent continuu de la senzorul de CO2 . in acest mod clapeta de intrare aer proasp`t poate modula deschiderea func\ie de semnalul senzorului;m. motorul de ac\ionare al clapetei de aer trebuie s` fie cuplat direct la sistemul de actionare al clapetei. nu se admite nici un sistem intermediar [ntre motor ]i stemul de ac\ionare;n. controlerul economizorului trebuie s` ofere informa\ii despe modul si perioada de function-
40
are in r`cire liber`, [n acest mod de lucru ventilatorul de scoatere aer trebuie s` fie [nchis.
2. Registru cu dou` pozi\iia. registrul trebuie s` fie cu dou` pozi\ii. Cursa registrului trebuie s` fie [n gama de la [nchidere total` la % din punctul setat de deschidere;b. registrul trebuie s` aib` o curs` ajustabil` [n domeniul 25% - 100% (complet deschis);c. registrul trebuie s` includ` lamele somplesau duale, sistem de ac\ionare ]i motor;d. motorul de ac\ionare trebuie s` fie cuplat direct la sistemul de actionare al registrului. nu se accepta nici un sistem intermediar [ntre motor ]i sistemul de ac\ionare;e. registrul trebuie s` permit` intrarea a 100% aer;f. registrul trebuie s` se [nchid` dup` ce ventilatorul evaporatorului s-a oprit ]i/sau exist` pierderi energetice;g. motorul de ac\ionare al registrului trebuie s` fie dotat cu siguran\` in tabloul electric al unit`\ii;h. parte extern` trebuie s` includ` filtru din aluminiu pentru ap`.
3. Registru manuala. registrul manual trebuie s` fie format dintr-un cadru de admisie aer, protec\ie antistopi ap` ce poate fi presetat` s` admita 50% debit aer [n raport cu cantitatea anual` necesar`.
4. Pachetul de control al presiuniia. controlerul trebuie s` gestioneze presiunea freonului [n condensator [n ciclul de func\ionare;
5. Kitt conversie GPLa. pachetul trebuie s` con\in` toate elementele ce trebuie schimbate ]i instruc\iunile pentru a converti unitatea de la func\ionarea pe gaz natural la GPL, pentru [n`l\imi de montaj de p@n` la 610 m.
6. {ntreruptoare electrice, f`r` siguran\`, montate de fabric`a. trebuie s` fie montate de fabric`;b. trebuie s` corespund` legisla\iei specifice [n vigoare;c. trebuie s` fie accesibile din exteriorul unit`\ii;d. trebuie s` fie capabile s` [ntrerup` local func\ionarea unit`\ii;e. nu este necesar` priz` exterioar`;f. dac` unitatea este prev`zut` cu priz` de curent electric suplimentar`, aceasta trebuie s` fie alimentat` separat de [ntreruptorul electric de pe unitate;g. unitatea nu trebuie s` includ` transformator;h. priza suplimentar` trebuie s` aiba conector standard pentru tensiunea furnizat`;i. amperajul maxim al prizei suplimentare trebuie s` fie de 15 A;j. priza suplimentar` trebuie s` fie accesibil` din afara unit`\ii.
7. Co]ul de fuma. trebuie s` asigure desc`rcare vertical`;b. trebuie s` aib` tiraj natural.
8.Conectori prin ]asiua. unitatea trebuie s` permit` trecerea cablurilor electrice ]i a \evii de alimentare cu gaz prin ]asiul unit`\ii fara s` scad` rezisten\a acestuia.
9. Evacuarea de aera. trebuie utilizat` [mpreun` cu un economizor de energie
41
b. trebuie s` existe module independente pentru circula\ia vertical` ]i pentru cea orizontal`;c. modulul pentru circula\ia orizontal` trebuie montat pe ductul de retur;d. func\ionarea trebuie gestionat` de controlerul economizorului. ventilatoarele exhaustoare trebuie s` porneasc` c@nd registrul se afl` [n domeniul 0 - 100% deschis.
10 Soclul de montaj (vertical)a. [ntreg perimetrul soclului de montaj cu capacitate exhaustoare trebuie s` permit` curent de aer separat pentru recuperarea de energie a aerului eliminat f`r` contaminarea aerului de intrare;b. trebuies` fie din o\el galvanizat ]i s` poat` suporta [ntreaga greutate a unit`\ii;c. s` permit` instalarea ]i securizarea ducturilor cu prioritate a montajului unit`\ii pe soclu.
11. Kitt de conversie universal` gaza. trebuie s` con\in` toate piesele ]i instruc\iunile pentru conversia unit`\ii de la func\ionare pe gaz, eleva\ie 610 - 2134 m la func\ionare pe GPL, eleva\ie 90 - 2134 m.
12. Senzorul entalpic externa. trebuie s` permit` controlul entalpic, cand va fi folosit [n conjunc\ie cu un senzor entalpic pe returul de aer, unitatea va oferi un control diferen\ial entalpic. senzorul va trebui s` deter-mine dac` condi\iile atmosferice permit func\ionarea [n regim de r`cire liber`.
13. Senzorul entalpic pe retur aera. trebuie utilizat [mpreun` cu senzorul entalpic extern pentru a permite cotrolul entalpic diferen\ial.
14. Senzorul de CO2a. trebuie s` permit` cererea de ventilare a aerului din interior.b. senzorul pentru controlul calit`\ii aerului din interior trebuie s` se poata instala pe perete cu dispaly LED. Trebuie s` poat` fi setat` valoarea limit`.
15. Detector de fuma. detectorul ]i controlorul trebuie s` fie de tipul cu patru fire;b. trebuie s` fie de tipul compensabil cu condi\iile de mediu, stabil ]i sensibil;c. senzorul trebuie s` fie cu activare/resetare magnetic`d. accesul la senzor trebuie s` se fac` f`r` utilizarea de scule;e. trebuie s` aib` un sistem d cu actionare manual` pentru testare ]i resetare;f. controler-ul trebuie s` includ`: - contactoare pentru transmisia la distan\` a semnalului; - dou` relee de alarm` auxiliare pentru interfata cu rooftop-ul ]i cu alt echipament; - un releu suplimentar pentru controlul suplimentar (indecizie) cu conectare la distan\`; - capacitatea de a conecta dou` detectoare independente; - s` poat` fi conectate alte 14 detectoare de fum pentru controlul multiplu al ventila-toarelor.
42