trespa sisteme de panouri pentru fatade ventilate meteon

50
Façade cladding Fascias Soffits Single-skin panels Sandwich panels ...à la carte. exterior All the best qualities in one panel

Upload: chiorean-andrei

Post on 18-Aug-2015

28 views

Category:

Documents


6 download

DESCRIPTION

sisteme de panouri HPL pentru fatade.

TRANSCRIPT

Trespa International BVInt. Antwoordnummer 2508C.C.R.I. 25086014 ZX IttervoortNederlandPays-BasRPONSE PAYEPAYS-BASTrespa UK LtdGrosvenor HouseHollinswood RoadCentral ParkTelfordTF2 9TWBUSINESS REPLY SERVICELICENCE NO. NWW 165381Faade claddingFasciasSoffitsSingle-skin panelsSandwich panels ... la carte.exteriorU001Zandbeek Communication Group (NL) 0405/3.000All the best qualities in one panelQuality.Design la carte.VISIT OUR WEBSITEWWW.TRESPA.COMTrespa International BVFour perfect product linesConditions of SaleRegisteredtrademarksTrespa International BV specializes in highquality panel material for faade claddingand interior use. Trespa has both the expertiseand the means to develop products for specificsegments of the market. Trespa is continuallylooking for ways to protect the environmenteven more effectively.Production of the faade cladding materialTrespa Meteon is based on unique, patentedtechniques, which guarantee excellentweather resistance and colourfastness.Trespa Athlon, which offers you outstandingmoisture resistance along with scratch andwear resistance, is particularly suitable forinterior use. Trespa Virtuon is aestheticallypleasing and the perfect product for interiorapplications where durability, hygiene,cleanability are required. And TrespaTopLabPLUS, highly resistant to chemicalsand designed for use as laboratory worktops,completes the product programme.Trespa guarantees quality of both productsand services. We offer our customersoptimal technical support as well asstraightforward documentation. Proof ofthis approach is the award of the ISO 9001and ISO 14001 certificates. Whatever your requirements, Trespa offersa full support service. Please contact us forfurther information.To all our offers, quotations, sales, deliveriesand supplies and/or agreements, and to allrelated services and activities the TrespaInternational B.V. General Conditions ofSale apply, filed at the Venlo Chamber ofCommerce on 1 January 2004, registeredunder number 24270677, and appearing onthe website at www.trespa.com. The text ofthese General Terms and Conditions will besent to you upon request. Trespa, Meteon, Athlon, Toplab, Virtuon,Volkern, Ioniq and Inspirations are registeredtrademarks of Trespa International BV.Trespa UK LtdGrosvenor HouseHollinswood RoadCentral Park, TelfordTF2 9TWTel.: 44 (0) 1952 290707Fax: 44 (0) 1952 [email protected] International BVPostbus 110, 6000 AC WeertWetering 20, 6002 SM WeertThe NetherlandsVerkoop NederlandTel.: 31 (0) 495 458 850Fax: 31 (0) 495 540 [email protected] ExportTel.: 31 (0) 495 458 359 / 392 / 578 Fax: 31 (0) 495 458 383 [email protected] Asia/Pacific Sales SupportTel.: 31 (0) 495 458 538 Fax: 31 (0) 495 458 383 [email protected] Belgium Bvba/SprlH. van Veldekesingel 150 B. 193500 HasseltTel.: 0800 - 15501Fax: 0800 - [email protected] Duch de LuxembourgTel.: 31 (0) 495 458 308Trespa Deutschland GmbHEuropaallee 27, D-50226 FrechenTel.: 0800 - 186 04 22Fax: 0800 - 186 07 [email protected] France18 rue Chartran92200 Neuilly sur Seine Tel.: 33 (0) 1 41 92 04 80Fax: 33 (0) 1 41 92 04 [email protected] s.l.Gran Via, 680 tico 08010 BarcelonaTel.: 34 (93) 488 03 18Fax: 34 (93) 487 32 36www.getsl.com /[email protected] North America Ltd.12267 Crosthwaite CirclePoway, CA 92064Tel.: (1)-800-4-TRESPAFax: (1)[email protected] Japan Ltd.Toranomon Toyo Building 6F4-2 Toranomon, 1-chomeMinato-ku, Tokyo 105-0001Tel.: 81 (0) 3 3500 5080Fax: 81 (0) 3 3504 [email protected] China Co. Ltd.Room 2907, Plaza 66No. 1266 Nanjing Road (W)Shanghai 200040 P.R.C.Tel.: 86 (0) 21 6288 1299Fax: 86 (0) 21 6288 [email protected] Asia/PacificTel.: 86 (0) 21 6120 1011Fax: 86 (0) 21 6288 1022Trespa Singapore Pte Ltd.UOB Plaza 180 Raffles PlaceLevel 36 Room 37Singapore 048624Tel.: 65 6248 4613Fax: 65 6248 4613ResponsibilityAll information is based on our currentstate of knowledge. It is intended asinformation concerning our productsand their application possibilities, andis therefore not intended as any formof guarantee with regard to any specificproduct characteristic.ColoursThe colours in this document areprinted, and therefore, may varyslightly from the original Trespa panelcolours with respect to gloss, colourshades and surface texture. Originalsamples are available on request. Copyrights All rights reserved. No part of thispublication may be reproduced, storedin a retrieval system, or made public, inany form or by any means, eithergraphic, electronic or mechanical,including photocopying, recording orotherwise, without the prior writtenpermission of Trespa International BV.www.trespa.comAll the best qualities in one panelNoteD147Yes,I would like to have more information:I IPlease call me for further information about ......................................................I IPlease call me for an appointment with your sales representativeI IOther,......................................................................................................................................................Company: ....................................................................................................................................................Name: ................................................................................................................................................M/FPosition: ........................................................................................................................................................Address: ........................................................................................................................................................Postal code: .....................................................Town: ......................................................................Country: .......................................................................................................................................................Telephone: .............................................................Fax: ......................................................................E-mail: ............................................................................................................................................................Please send the coupon to the address on the back or contact the Trespa sales organisation in your country (address on the back of this brochure).R E P L Y C A R DU001Yes,I would like to have more information:I IPlease call me for further information about ......................................................I IPlease call me for an appointment with your sales representativeI IOther,......................................................................................................................................................Company: ....................................................................................................................................................Name: ................................................................................................................................................M/FPosition: ........................................................................................................................................................Address: ........................................................................................................................................................Postal code: .....................................................Town: ......................................................................Country: .......................................................................................................................................................Telephone: .............................................................Fax: ......................................................................E-mail: ............................................................................................................................................................Please send the coupon to the address on the back or contact the Trespa sales organisation in your country (address on the back of this brochure).R E P L Y C A R DU001D12ContentsGeneral information 3Product data Trespa Meteon 4Application and delivery programme 5Fabrication and installation of Trespa Meteon Metallics and Naturals 6Service and guarantee 6The technological quality 7The technical quality 8Faade applications 9Ventilated faade cladding 9Ventilation 10Fire precautions 10Joints 11Corner solutions 12General guidelines faade cladding 13Fixing systems 13General guidelines fixing systems 13TS150: Visible fixing with screws on a timber subframe 15TS700: Visible fixing with blind rivets on an aluminium subframe 19TS200: Invisible fixing with screws or inserts 25TS400: Invisible fixing with adhesive and screws 29TS300: Blind fixing using profiled edges 32TS650: Blind fixing with clips (Sidings) 33Panels in frames 35Single-skin panels in frames 35Sandwich panels in frames 37System 700 for overcladding 38Special fixings 39Building regulations 40Standards 40Auxiliary profiles 40Fixings 41Deflection 43Wind loads and load bearing 44Addresses 48Trespa Meteonis I a high-quality building product from Trespa International B.V.I specifically developed for durable exterior claddingI architecturally versatileI technically advanced I economicalI environmentally friendlyGeneral information.D13D14Material properties Trespa Meteon Properties Value Unit StandardPhysical propertiesSpecific gravity 1,350 kg/m3ISO 1183Dimensional stability 2.5 mm/m --Water absorbtion 1.0 % weight EN 438Optical propertiesColour stability 4-5 (2,500 hrs; Xenon test) Grey Scale ISO 105 A02-93Mechanical propertiesModulus of elasticity 9,000 N/mm2ISO 178Tensile strength 70 N/mm2ISO 527-2Flexural strength 120 N/mm2ISO 178Surface impact resistance 40 N EN 438Scratch resistance 3.5 N EN 438Thermal propertiesThermal conductivity 0.3 W/mK DIN 52612Chemical propertiesSO2-resistance 4-5 (50 cycles; approx. Grey Scale DIN 500180.0067%)Fire behaviourGreat Britain Type FR: Class 0 BS 476 Parts 6-7Fire classification Type Standard: Class 2/3 Building regulationsNetherlands Type FR: Klasse 1 NEN 6065Brandklasse Type Standaard: Klasse 2 NEN 6065Germany Typ FR: Klasse B1 DIN 4102Baustoffklasse Typ Standard: Klasse B2 DIN 4102France Type FR: Classement M1 NF P 92-507-UNE 23727Raction au feuType Standard: Classement M3 NF P 92-507-UNE 23727Indice de fume Type FR: Classement F1 NF X 10-702Toxicit des gaz de combustion Type Standard: Classement F1 NF X 70-100Product data Trespa Meteon.Unique and special Trespa Meteon is a flat panel, based on thermosetting resins,homogeneously reinforced with wood fibres and manufacturedunder high pressure and at high temperatures, using aproprietary technology (EBC). The panels have an integrateddecorative surface.Trespa Meteon is used for faade cladding, fascias, soffits,balcony panels and balustrades, urban furniture, sandwichpanels and a wide range of other exterior applications. Trespa Meteon is highly suited for ventilated facade systems.These breathing or envelope systems offer possibilities forhigh insulation values, perfect building physics and contributeto a healthy indoor climate. In Summer, excessive solar heat can be vented away through theventilation between the panels and the insulation materials.Trespa Meteon is available in more than 50 colours, with one or both decorative surfaces. The panels have a finely structuredsurface (satin). For high quality architectural applicationsTrespa developed an entire new concept: INSPIRATIONS. At the moment Trespa introduces five different kinds of faadecladding panels through Inspirations: Naturals, Metallics,Natural Prints, Gloss and Rock. Please contact Trespa forfurther information. The delivery programme of Trespa Meteonfurthermore offers a standard type with black core and a fireretardant panel with brown core.Trespa also offers Meteon corner profile elements that meet thesame high standards of Trespa Meteon flat panels. They areavailable with double-sided colour and Satin structure. Standardcorner profile element sizes: 3650 x 300 x 300, radius 20 mm.Standard corner profile element thicknesses: 8 and 10 mm.Application and delivery programme.D15D16OptimizingFixingTrespa Meteon Metallicsand Naturals cornerprofilesOrdering Trespa Meteon MetallicsWarranteesTrespa Meteon Metallics and Naturals panels feature a directionalcoloured surface. In order to achieve te same orientation of thepanels please take notice of the following points:When optimizing Trespa Meteon Metallics and Naturals panelsthe direction should always be taken into account. Arrows onthe back side of the fullsize panels have been applied by Trespa toindicate the direction the sheets have been produced (illustration 1)When cutting the sheets we advise you to temporarily mark theoriginal production direction on the visible side of theindividual panels. The fixing of the panels in the same directionwil be easier and this way there will be no undesirable colourdistinction (illustration 2). All other instructions for processingand fixing are as standard Trespa Meteon panels.Corner profile and sheet lenghts have corresponding direction.The quantity of Trespa Meteon Metallics sheets required for aproject should be ordered and supplied as a single instruction.Thanks to practical experience over many years and the highquality of Trespa Meteon panels, warrantees are available bothfor the product range in general and for specific projects. Moreinformation can be obtained from your local Trespa office orrepresentative.Fabrication and installation of Trespa Meteon Metallics and Naturals.Illustration 1Illustration 2Service and guarantees.D17The technological quality.Environmental considerationsBuildingcertificatesEnvironmental considerations play a significant role in thedevelopment and manufacture of Trespa Meteon. Panels consistof approximately 70% softwood fibre and 30% thermosettingresin. The wood fibre comes from fast-growing pine woodfrom European production forests. Overall some 85% of theused raw materials are rapidly renewable. In addition up to10% of residual materials from production are recycled toproduce new Trespa construction panels.Trespa International was one of the first producers of panelmaterial to be certified according to ISO 14001, awarded byLloyds Register. The ISO 14001 standard describes the stepsrequired for setting up, implementing, maintaining and improvinga completely integrated environmental management system. At end of their life cycle Trespa Meteon panels can be thermallyrecycled with energy recovery locally in an industrial incineratoras they contain no heavy metals, halogens or biocides.Trespa International is able to provide information about thecharacteristics of Trespa Meteon, its safety and effect on theenvironment and has available full product Life Cycle Analyses(LCAs).All major European certification institutes which form theEuropean Union of Agrment (UEATC) have certified bothTrespa Meteon and its recommended fixing systems. Certificatesare issued by amongst others: KOMO; DIBt; BUtgb; BBA;CSTB and TORROJA.D18Weather resistantEasy to keep cleanVandalismSafe fire behaviourThe technical quality.Trespa Meteon is extremely weather resistant. Neither sun, rain including acid rain nor moisture have any effect on the panelssurface or core. Both the UV resistance and colour stability arevery high with a 4-5 classification on the International GreyScale (ISO 105 A 02). Large or rapid temperature fluctuationsfrom -20C to +80C do not affect the properties, stability orappearance of the panel. Colours will not change significantly forat least ten years, even under the most severe climatic conditions,or in heavily polluted industrial areas.The smooth panel surface has a closed non-porous structure,ensuring that practically no dirt accumulates. Neither the surfacenor the sawn edges need to be painted or provided with aprotective cover. Trespa Meteon is completely unaffected byhousehold cleaning agents or strong organic solvents.The favourable combination of flexural strength and elasticity make the panel material highly impact resistant. It is therefore highly suitable for application in environments that are exposed to vandalism.Graffiti can easily be removed without altering the propertiesof Trespa Meteon.In a fire, Trespa Meteon does not melt, drip or explode andretains its stability for a long time. Key European testing bodies have awarded Trespa Meteon FRgrade the most favourable classifications for organic materialfire behaviour.+50C+40C+30C+20C+10C0C- 10C+70C+60CPsPw+20CRH = 60%-10CRH = 80% The load-bearing structure of a building with an exterior insulation layer can be simply protected from weather influences by Trespa faade cladding.A ventilated cavity between the faade cladding and the insulation layer prevents rainwater from penetrating and diffuses water vapour from the inside to the outside. The presence of ventilation prevents damp from accumulating behind the panels. The subframe will not be affected or rot and the insulation material is prevented from getting wet.Good ventilation demands that there are openings in the upper and lower edges of the faade cladding. These are also necessary at the upper and lower edges of window and door openings.Joint profiles usually have an aesthetic function and are able to limit the amount of moisture that penetrates. However, these profiles are not essential to guarantee the water tightness of the faade. Moisture that penetrates is discharged through the ventilated cavity.A ventilated faade has the following physical and structural advantages:I No moisture problems in the faade structure as a result ofinternal condensation or rain penetration.I Movement of the main load-bearing structure is kept to aminimum by low temperature fluctuations.I Local cold bridges are kept to a minimum because the load-bearing structure is insulated on the outside.Ventilated faade cladding.FAADE APPLICATIONS.TEMPERATURE DEVELOPMENT IN SUMMER AND WINTERTemperature development in summerTemperature development in winterMOISTURE LOADS ON FAADE STRUCTURERainResidentialmoisturePs = maximum vapour tensionPw = actual vapour tensionPs>Pwno internal condensationVENTILATIONVENTILATIOND19D110Good ventilation of the Trespa faade cladding may be obtained by following the guidelines listed below:I A continuous ventilated cavity of at least 20 mm should bepresent behind the faade cladding to prevent damage to thefaade as a result of condensation in the cavity and/or rain penetration.I Ventilation openings may be reduced locally to 5 mm.I The upper and lower sides of the faade cladding and door and window openings should have ventilation openings that are in direct contact with the outside air.I On the one hand the size of the ventilation opening isdetermined by the height of the faade cladding, and on theother hand by local circumstances. Every linear metreshould have at least:I 20 cm2/m of ventilation for faade cladding heights up to 1 metre;I 50 cm2/m of ventilation for faade cladding heights exceeding 1 metre.I Ventilation openings that are larger than 10 mm should bemade in such a way that insects and vermin cannot getbehind the faade cladding.Fire precautions.Movement of fire within the cavity and/or insulation materials can possibly take place for multi- storey faades. Proven systems are developed to prevent this. These systems are constructed with incombustible insulation materials and continuous horizontal stainless steel fire breaks; Trespa panels contribute to the required resistance of fire breaking through.BETWEEN THE VERTICAL BATTENSBETWEEN THE HORIZONTAL BATTENSVentilation.D111a10 mmf 8 mmafaaaa 10 mmb15 mmc 2,9 mmd2,2 mme 2 mmf 8 mmaaabeccd fa2a2a2a2aThe following guidelines apply to joints and panel connections:I The panels should be able to move 2.5 mm per metre in thelength and the width. Therefore sufficient space should beallowed for around the panels.I Panel, assembly and building tolerances play an importantrole in the joint details. The panels should also be able tomove. Therefore a minimum joint width of 10 mm is required.I The joints should be such that sufficient ventilation and/ordrainage is ensured in order to prevent damage as a result ofretained moisture.I Insects and vermin may nestle behind the faade cladding.Joints that are larger than 10 mm should therefore be fixedwith grilles, wire netting, etc.OPEN JOINTSThe panel connections may either be open or sealed. If an openjoint system is used for vertical and/or horizontal joints, specificattention should be paid to possible rain or moisture penetration.When the insulation becomes wet the insulation value decreasesso no longer complies with standards. Moisture resistantinsulation materials and subframes are therefore required. A vapour open foil can be used as a second water barrier.CLOSED JOINTSTongued-and-grooved and halved jointsWith a minimum of 8 mm thick panel it is possible to havetongue-and-grooved joints on vertical edges or halved joints onthe horizontal edges. This effects a closed joint system. Theminimum dimensions for the joints are:I groove:2.2 x 15 mm for closed aluminium tongues(panel thickness ! 8 mm)3.2 x 15 mm for Trespa tongues(panel thickness ! 10 mm)I tongue:2 x 30 mm for aluminium tongues3 x 30 mm for Trespa tonguesI height of halved joint: 20 mmJoint profilesJoints may be closed by fixing metal, plastic or rubber profiles. The profiles should not impede the movement of the panels and should be fixed free of tension.Mastic jointsMastic joints impede the movement of the panels and may leadto excessive dirt on the panel edges. This type of joint sealing istherefore specifically not recommended.HORIZONTAL JOINTSOpen joint Halved joint Joint profileVERTICAL JOINTSOmega profileJoint gasketTongue-and-grooveOpen jointJoints.a ! 10 mmb ! 15 mmc ! 2.9 mmd ! 2.2 mme ! 2 mmf ! 8 mmD112baaa 5 mm b 300 mm c 8 mmcca 5 mmaaa3650b = 300 mmr = 20 mm rPanel connections at the corners of buildings may have either open or closed joints. Panels from 8 mm thickness are suitable for a fixed corner connection where a metal corner profile is fixed to the back of the panel with screws or inserts. Special allowances should be made for the differences in length. If one of the panels is then not able to move in one or more directions the width of the section in question may not exceed 300 mm. The delivery programme offers a Trespa corner profile element which can be used for a smooth corner detail.Open cornerCorner profileTrespa corner Joint gasket profile elementCorner solutions.Fixed corner Corner profileTongue-and grooveD113The following aspects should receive attention when a faade construction consisting of Trespa panels, subframes and fixings are dimensioned:I The panels should be suitable for use as self-supporting,faade cladding.I When combined with the subframe the panel strength andrigidity should be sufficient to withstand normal loads suchas wind, dead weight and/or impact, without beingdamaged.I The faade cladding should not have a structural function.I If heavy objects are to be suspended from the panels,additional facilities are usually required.I The maximum permissible impact loads on the panels andsubframes can be determined by means of specific tests(usually the sandbag swing test).I Trespa Meteon Metallic panels feature a directional colouredsurface. See page 6 for further information.Trespa is assembled with corrosion resistant fixings on a suitable subframe in such a way that the panels are not under tension and are able to move freely. When determining the subframe the following should be kept in mind:I wind loadingI the maximum fixing centres for the panelsI the required ventilation provisionsI unimpeded movement of the panelsI the available panel dimensionsI thickness of insulation material used, if anyI the anchoring possibilities in the structural (wall)constructionI legal requirementsFixingTrespa panels may be fixed by the means given below. Variations and combinations of the methods are optional. The details in this brochure give the principles of the fixing systems and do not refer to trade names. Treating of panel edges is not required as shown in the details. fixed visibly with screws fixed visibly with rivets invisible fixing with screws or (conical) inserts invisible fixing with adhesive and screws single-skin panel in frame sandwich panel in frameGeneral guidelines faade cladding.General guidelines fixing systems.FIXING SYSTEMS.D114bccccbb a a bD115TS150: Visible fixing with screws on a timber subframe.Panels with a thickness of 6 mm or more can be fixed onto a timber subframe. This subframe must consist of battens of sufficient strength and permanent durability.* Powdercoated screws or plastic cover caps are available in all standard Trespa colours.* See chapter StandardsGeneralJoints: at least 10 mmPanel thickness: from 6 mmFixing centres and edge clearancesa = horizontal fixing centre (see table)b = edge clearanceI minimum 20 mmI maximum 10 x panel thicknessc= vertical fixing centre (see table)maximum fixing centres (in mm)* panel thickness (in mm)6 8 10 132 fixings in one direction 450 600 750 9503 or more fixings in one direction 550 750 900 1,200* See also chapters Deflection and Wind loadsFixing detailFast fixing screw for Trespa for 6 mm to 10 mm panels.Diameter of the hole for all fixing points:I 8 mm for fast fixing screw for TrespaI shank diameter of the screw + 3 mm for other screwsTimber battens should be at least:I 34 x 75 mm for joints between two panelsI 34 x 45 mm for inner and end battensScrews should be centered in the holes and not beovertightened.872 3523 76145D116TS150: Visible fixing with screws on a timber subframe.HORIZONTAL CROSS-SECTIONFaade details1. Trespa Meteon corner profile2. Trespa Meteon panel3. Cavity4. Timber batten5. Trespa 'fast fix' screw6. Gasket7. Insulation8. Coping profileWindow detailsFaade detailsVERTICAL CROSS-SECTION71 5 623498D117TS150: Visible fixing with screws on a timber subframe.VERTICAL CROSS-SECTIONWindow detailsFaade details1. Trespa Meteon panel 2. Screw (in the same colouras the panel)3. Vertical batten4. Horizontal batten5. Cavity6. Insulation7. Coping profile8. Sill9. Ventilation profile4526133D118TS150: Visible fixing with screws on a timber subframe.VERTICAL CROSS-SECTIONSoffit details1. Trespa Meteon panel 2. Screw (in the same colour as the panel)3. Horizontal batten4. Gasket5. Cavity6. Insulationaccccb bab babbccccbbyxD119TS700: Visible fixing with blind rivets on an aluminiumsubframe.Panels that are of minimum 6 mm thickness may be fixed with rivets. The subframe should preferably consist of vertical profiles which are fixed to the structure with special wall brackets.*Horizontal and/or vertical adjusting tolerances are essential.* See chapter StandardsGeneralJoints: at least 10 mmPanel thickness: from 6 mmFixing centres and edge clearancesa =horizontal fixing centre (see table)b =edge clearanceI minimum 20 mmI maximimum 10 x panel thicknessc =vertical fixing centre (see table)x =maximum 3050 mmy =maximum 3050 mma=fixed point in panel centres=sliding pointmaximum fixing centres (in mm)* panel thickness (in mm)6 8 10 132 fixings in one direction 450 600 750 9503 or more fixings in one direction 550 750 9001,200* See also chapters Deflection and Wind loads.Fixing detailDiameter of the hole: I fixed point = 5.1 mmI sliding points = 10 mm If the fixed point cannot be placed at the centre of the panel, 2 fixed points may made next to each other. The associated diameter of the hole should then be 1 mm larger than the rivet diameter.A neoprene gasket of 1.5 mm thickness on the subframe can also be used when the fixed point is not in the centre of the panel.The rivet head should be 0.3 mm free from the panel surface by using a special tool.Fixing point Sliding pointD1201358946 722D121TS700: Visible fixing with blind rivets on an aluminiumsubframe.HORIZONTAL CROSS-SECTIONFaade details Window details1. Trespa Meteon panel 2. Aluminium corner profile3. Aluminium rivet (with coloured head)4. Aluminium L-profile 5. Aluminium T-profile6. Cavity7. Insulation8. Aluminium rivet9. Anchor bolt81210936 755411D122TS700: Visible fixing with blind rivets on an aluminiumsubframe.VERTICAL CROSS-SECTIONWindow details Faade details1. Trespa Meteon panel 2. Aluminium rivet (with coloured head)3. Aluminium L-profile 4. Fixed point5. Sliding point6. Cavity7. Insulation8. Coping profile9. Sill10. Ventilation profile11. Anchor bolt5 6 5109387 421 5D123TS700: Visible fixing with blind rivets on an aluminiumsubframe.VERTICAL CROSS-SECTIONSoffitdetails1. Trespa Meteon panel 2. Aluminium rivet (with coloured head)3. Aluminium L-profile 4. Aluminium T-profile5. Fixed point6. Sliding point7. Cavity8. Insulation9. Aluminium rivet10. Anchor boltD124accccb bab babbccccbbx x x xD125TS200: Invisible fixing withscrews or inserts.Panels of minimum 8 mm thickness may be fixed invisibly byfixing metal hanging brackets with inserts or screws to the backof the panel. Invisible fixings for 8 mm panels are possible to alimited extent. The panels are fixed to metal subframe.Each panel has two adjusting points and a fixed point at thetop; so adjusting is possible and unwanted movement of thewhole panel can not happen.GeneralJoints: at least 10 mmPanel thickness: from 8 mmShortest panel leg of assembled corner panels may not exceed 300 mm if not, a fixed point in the angle is necessary.Fixing and edge clearancesa=horizontal fixing centre (see table)b=edge clearanceI minimum 80 mm I maximum 10 x panel thicknessc =vertical fixing centre (see table)a=fixed point =adjusting points=sliding point:Lower brackets fixed higher at such a level as tofacilitate downward panel movement (2.5 mm/m1) maximum fixing centres ( in mm)* panel thickness (in mm)8 10 132 fixings in one direction 600 750 9503 or more fixings in one direction 750 900 1,200* See also chapters Deflection and Wind loads.Fixing detailFixing method (see also chapter Accessories)I straight insertI thread cutting screwI conical insertRemaining panel thickness: at least 2.5 mm.Anchoring depth: panel thickness - 3 mm.3910111 575814313212644 D126TS200: Invisible fixing withscrews or inserts.HORIZONTAL CROSS-SECTIONFaade details Window details1. Trespa Meteon panel 2. Aluminium profile3. Insert4. Aluminium rail5. Adjusting screw6. Fixed point7. Aluminium bracket8. Trespa tongue9. Aluminium angle10. Cavity11. Insulation12. Aluminium rivet (with coloured head)13. Anchor bolt14. Aluminium wall bracket37131281 2 1110643515 914D127TS200: Invisible fixing withscrews or inserts.VERTICAL CROSS-SECTIONWindow details Faade details1. Trespa Meteon panel2. Vertical batten3. Insert4. Adjusting screw5. Aluminium rail6. Aluminium bracket7. Aluminium angle8. Fixed point9. Sliding point10. Cavity11. Insulation12. Coping profile13. Sill14. Ventilation profile15. Wood screw 981731110 264512D128TS200: Invisible fixing withscrews or inserts.VERTICAL CROSS-SECTIONSoffitdetails1. Trespa Meteon panel2. Vertical batten3. Insert4. Adjusting screw5. Aluminium rail6. Aluminium bracket7. Trespa tongue8. Fixed point9. Sliding point10. Cavity11. Insulation12. Wood screwyaxadD129TS400: Invisible fixing withadhesive and screws.The effectiveness of an adhesive fixed panel is determined mainly by the weather conditions at the time of fixing. Damp, cold and/or dusty conditions may have a negative effect. Fixing the Trespa panels to wood or metal subframes is therefore only possible when: I for reasons of safety two screws or rivets are fixed to thetop edge of every panelI the maximum specified panel dimensions have not beenexceeded so that the panels are able to move freelyI the bonded joint is made verticallyI the guidelines specified by the adhesive manufacturers andadvised by Trespa are adhered toGeneralJoints: minimum 10 mmPanel thickness: from 6 mmPanel dimensions: maximum length 2550 mm, maximum surface 2.5 m2.Fixing and distances from the edgea= horizontal fixing centre (see table)d= edge clearance: minimum 20 mmx= panel widthy= panel heightmaximum fixing centres ( in mm)* panel thickness (in mm)6 8 102 fixings in one direction 450 600 6503 or more fixings in one direction 550 650 650* See also chapters Deflection and Wind loads.Fixing detailAt least two mechanical fixings (screws) in the upper edge of the panelDiameter of the hole for the screws:I 8 mm for fast fixing screw for TrespaI shank diameter of the screw + 3mm for other screwsPlaned timber battens minimum:I end battens: 45 x 28 mmI intermediate battens: 55 x 28 mmI intermediate panel jointing battens: 85 x 28 mmD13014536721 368D131TS400: Invisible fixing withadhesive and screws.HORIZONTAL CROSS-SECTIONFaade details1. Trespa Meteon panel2. Screw (in the colour of the panel)3. Vertical batten (planed)4. Adhesive bead5. Double-sided adhesive tape6. Cavity7. Coping profile8. Ventilation profileWindow detailsVERTICALCROSS-SECTIONFaade detailsD132D132TS300: Blind fixing usingprofiled edges8, 10 and 13mm thick panels can be installed by fitting theirspecially grooved horizontal edges into continuous aluminiumTS-300 rails.The horizontal aluminium TS-300 rails can be fixed to a verticaltimber or aluminium support construction.The groovedhorizontaledges enable the panels to be attachedto the aluminium rails, while hiding the rails from sight.The TS-300 fixing method is typically suited to install largeuninterrupted faade surfaces with horizontal lines.GeneralJoints: 10 mmPanel thicknesses: 8, 10 and 13mmPanel sizeThe TS-300 fixing method can only be used for single-fieldspans. As a result, the maximum panel height is limited as indicated in the table below. The maximum panel width is 1500 mm.Panel thickness Maximum panel height (in mm)*8 mm 600 mm10 mm 750 mm13 mm 900 mm* Also see the chapters on Deflection andWind LoadsTRESPA SYSTEM 300D133TS650: Blind fixing withclips (Sidings)8mm thick Trespa panels have a groove in their bottom edgeenabling them to be attached using special stainless steel fixingclamps.The panels are installed from the bottom upwards, with thefirst line of clamps being fixed to adjusting blocks or to an8mm thick adjusting batten (see details). The panels in the toprow are screwed at their top edge.GeneralJoints: minimum 10mmPanel thickness: 8mmFixing and edge distancesThe panel overlap is approx. 25 mm.The panel height can vary from 200 to 300 mm; the max. panellength is 3650 mm. The horizontal clamp fixing distance is max.600 mm centre-to-centre.Max. building height 8 m:Panel thickness Hor. fixing distance Panel height8 mm 600 mm 200 - 300 mmFixing detailThe Trespa panels are fixed to vertical timber battens with cen-tre-to-centre distances of max. 600 mm. The minimum battenwidth at the joints must be 75 mm. A width of 50 mm is suffi-cient for the other battens.Every panel is secured in the centre once to prevent it shiftinghorizontally.VERTICAL CROSS-SECTION1. Stainless steel clamp screwed onto timber2. Thermal insulation3. Breather foil4. Ventilated cavity5. Trespa 8 mm6. Adjustment block thickness 8 mm7. Ventilation strip132 4567D134Single-skin panelsin frames.PANELS IN FRAMES.Panels with a thickness from 6 mm can be placed into wood, metal and plastic frames. Single-skin panels are suitable for insulated as well as non-insulated walls. Ventilation behind the panel is always required. Therefore, cavities are made in the lower and upper horizontal profile. Water drains are also necessary in the lower horizontal profile. Durable EPDM gaskets close the gap between profile and panel, mastic and tape are not allowed for this.GeneralPanel thickness: from 6 mmPanel edge: 6 mm free from the frame at three sidesFixing centresx = smallest panel spany = largest panel spanmaximum spans x (in mm)relation _ypanel thickness (in mm)x6 8 10 131.0 620 830 1,040 1,3501.2 580 780 970 1,2601.4 550 730 910 1,1901.6 520 690 860 1,1301.8 490 660 820 1,0702.0 470 630 780 1,020!2.5 450 600 750 980Fixing detailGroove in profile: 20 mm deepEPDM gasket: minimum 4 mm after installationWater drains / ventilation horizontal profiles:I hole diameter 8 mmI slotted holes 5 x 25 mm; total 20 cm2/m1Two supports per panel: minimum 5 x 50 mmD135D136Sandwich panelsin frames.Trespa sandwich panels are composed of a core of insulatingmaterial and Trespa sheets glued on both sides. Panels can beplaced into wood, metal and plastic frames. Sandwich panels arevery suitable for thermal insulation, fire retardant and acousticaluse. Water drains are necessary in the lower horizontal profilealways. Durable EPDM gaskets close the gap between profileand panel; mastic and tape are not recommended for this.GeneralPanel thickness: minimum 16 mm Panel edge: 6 mm free from the frame at three sidesComposition: 3mm Trespa decor; PUR or PS as insulationMaximum spans on request Total thickness U-value with PUR-insulation(mm) ( = 0.030 W/mK)16 1.9121 1.4526 1.1731 0.9836 0.8446 0.6656 0.5466 0.46Fixing detailGroove in profile: 20 mm deepEPDM gasket: minimum 4 mm thickness after installationWater drains horizontal profiles:I hole diameter 8 mmI slotted holes 5 x 25 mmTwo supports per panel: minimum 5 x 50 mmD137D138Horizontal joint with rebated panelsFire breakWindow poolsSystem 700 for overcladding.Special fixings.TRESPA SYSTEM 300 (TS 300)SPECIAL FIXINGS.FASCIASCOMPRIALD139123Standards.The Building Regulations 1991A1; LoadingA3 & A4; Disproportionate collapseB1;Means of escapeB4;External fire spreadC4; Resistance to weather and ground moistureD1; Cavity insulationE1;Airborne sound (walls)F1; Means of ventilationF2;CondensationL; Conservation of fuel and powerK2; Protection from fallingREG 7;Materials and workmanshipBS 476;Fire tests on building materials and structures. Part 6.Method of test for fire propagation for productsPart 7.Method for classification of the surface spread offlame of productsAuxiliary profiles.Auxiliary profiles are available to close the joints in betweenthe Trespa panels. The most common are pictured below.The profiles can be supplied by third parties in various coloursand dimensions. The addresses of suppliers will be supplied onrequest.1. Plastic or aluminium corner profile2. Plastic or aluminium H profile for horizontal joints(please note that dirt marks are easily made)3. Plastic or metal ventilation profileBS 4471; Sizes of sawn and processed softwoodBS 5268;Structural use of timber. Part 5. Code of practicefor the preservative treatment of structural timberBS 6180; Protective barriers in and about buildingsBS 6206; Impact performance requirements for flat safetyglass and safety plastics for use in buildingsBS 8200; Design of non-loadbearing external verticalenclosures of buildingsCP3, Chapter V; Part 2: Basic data for the design of buildings.PD 6484; Commentary on corrosion at bimetallic contactandits alleviationBUILDING REGULATIONS.D140Fixings.Visible fixing1. Fast fixing screw for Trespa, stainless-steel, for 6 mm to 10 mm panelsMaterial: A2 or A4Diameter: 4.8 mmLength: minimum 36 mmHead diameter: 12 mmHead height: 2.5 mmHole diameter: 8 mmAvailable in all Trespa Meteon coloursFor use of other screws keep minimum 4 mm for diameter and 35 mm for length2. Aluminium or stainless steel blind rivet for panel thicknesses from 6 mmMaterial: AlMg5 or A2 or A4Diameter: 5 mmHead diameter: 14 mm (with cap in Trespa Meteon colours: 16 mm)Head diameter: 16 mm on request (in Trespa Meteon colours)Hole diameter: 10 mmLength: panel thickness + subframe + 5 mm minimumFast fixing srew for TrespaBlind rivetD141Fixings.Invisible fixing:1.M6 straight insert for panel thickness of 10 mm and moreMaterial: Insert: brass Srew: A2 or A4Diameter: Insert: 8.0 mm Screw: M6Length: Panel thickness 10:7.5 mmPanel thickness 13:10.5 mmHole diameter: 8.0 mmHole depth: special drill with depth stop2.Thread cutting screw for panel thickness of 8 mm and moreTyp: EJOT PT S 60xLMaterial: A4Diameter: 6.0 mmLength: Panel thickness 8:9.5 mmPanel thickness 10: 11.5 mmPanel thickness 13: 14.5 mm(inclusive 5 mm for bracket thickness)Hole diameter: 4.9 mm (DF-core)Hole diameter: 5.3 mm (kraft-core)Hole depth: special drill with depth stopPanel thickness 8:5.5 mmPanel thickness 10:7.5 mmPanel thickness 13: 10.5 mm3.Stainless-steel conical screw insertTyp: Keil Hinterschnittdbel M6Material: A4Hole depth:Panel thickness 8:5 mmPanel thickness 10:7 mmPanel thickness 13: 10 mmHole diameter: 7 mm/9 mmto be drilled with a special machine and drill4. Stainless-steel conical rivet insertTyp: Fischer - Zykon - Panelanchor FZPMaterial: A4Hole depth:Panel thickness 8:5 mmPanel thickness 10:7 mmPanel thickness 13: 10 mmHole diameter: 9 mm/11 mmto be drilled with a special machine and drillStraight insertThread cutting screwConical screw insertConical rivet insertD142300 400 500 600 700 800 900 1000 1100 1200350 450 550 650 750 850 950 1050 1150 600 700800 9001.0001.1001.2001.3001.4001.5001.6001.7001.8001.9002.0002.1006 mm 8 mm 10 mm 13 mmL300 400 500 600 700 800 900 1000 1100 1200350 450 550 650 750 850 950 1050 1150 600 700 800 9001.0001.1001.2001.3001.4001.5001.6001.7001.8001.9002.0002.10013 mm 6 mm 8 mm 10 mmL L LDeflection.The maximum flexure (f) limit, measured at the horizontalsurface of a faade panelbetween two fixing points (L),has been laid down. A minimum(wind) load should be takeninto account to prevent thefaade structure from not beingstrong enough.Faade cladding flexure: f L/200Wind loads may be multipliedwith 0.70for calculating paneldeflections, with respect to aminimum (wind) load of p 600 N/m2.Four sided supportedpanels:The graphs can be used fordetermining the thickness of a four sided supported panel.Determining the thickness, theshortest panel length (lx) maybe multiplied by correctionfactors below after reading thegraph:Relationcorrection factor_l_y for lxlx1.0 1.41.2 1.31.4 1.21.6 1.151.8 1.102.0 1.05 2.5 1.0DEFLECTION FOR 2-SUPPORTS (f=L/200)PANEL SPAN (MM)DEFLECTION FOR MORE THAN 2-SUPPORTS (f=L/200)PANEL SPAN (MM)ADMITTED WIND LOAD (N/M2)ADMITTED WIND LOAD (N/M2)D1435060484648484442 3840464854525046465648505256 544142Plymouth Bornemouth Brighton Bristol Oxford Cardiff Bedford Ipswich Norwich Leicester Northampton Birmingham Aberystwyth StokeNottingham Sheffield Liverpool Manchester Preston Leeds York CarlisleNewcastle Edinburgh Oban Inverness Perth Dundee Aberdeen LondonderryBelfastSwansea Kingston/Hull London Glasgow Wind loads and load bearing.Wind loads:Pw = c * v2/ 1.6p = wind pressurec = pressure coefficientv = wind speedLoad bearing:Load bearing of panels, supports and fixings included, has to take place in such a way that maximum loads do not exceed admitted strengths.The weight of a panel will be spread over several fixings and can be ignored in the calculation when a minimum (wind) load of 600 N/m2 is respected.Visible fixing:Maximum admittable pull-out strength for visible fixing with srews and rivets, depending on fixing position in panel:Pull-out strength Fixing position in panelPanel thickness centre edge corner6 mm 480N 300N 240N8 mm 500N* 500N* 430N*10 mm 500N* 500N* 500N** maximum pull-out strength for pine wood respectivelyaluminium rivet- including safety factor = 3; for screw, rivet and Trespa panel- safety factor = 4 for pull-out strength in woodCorner EdgeCentreBlind fixing:Maximum admittable pull-out strength for blind fixing with inserts.panel thickness Pull-out strengthstraight thread cutting conicalinsert screw insert8 mm 250N 350N 300N10 mm 350N 650N 400N13 mm 550N 1150N 950N- including safety factor = 3; for insert and Trespa panel- including excentricity factor = 2; for brackets (leverage effect)D144D145NoteD146NoteNoteD147Yes,I would like to have more information:I IPlease call me for further information about ......................................................I IPlease call me for an appointment with your sales representativeI IOther,......................................................................................................................................................Company: ....................................................................................................................................................Name: ................................................................................................................................................M/FPosition: ........................................................................................................................................................Address: ........................................................................................................................................................Postal code: .....................................................Town: ......................................................................Country: .......................................................................................................................................................Telephone: .............................................................Fax: ......................................................................E-mail: ............................................................................................................................................................Please send the coupon to the address on the back or contact the Trespa sales organisation in your country (address on the back of this brochure).R E P L Y C A R DU001Yes,I would like to have more information:I IPlease call me for further information about ......................................................I IPlease call me for an appointment with your sales representativeI IOther,......................................................................................................................................................Company: ....................................................................................................................................................Name: ................................................................................................................................................M/FPosition: ........................................................................................................................................................Address: ........................................................................................................................................................Postal code: .....................................................Town: ......................................................................Country: .......................................................................................................................................................Telephone: .............................................................Fax: ......................................................................E-mail: ............................................................................................................................................................Please send the coupon to the address on the back or contact the Trespa sales organisation in your country (address on the back of this brochure).R E P L Y C A R DU001D12ContentsGeneral information 3Product data Trespa Meteon 4Application and delivery programme 5Fabrication and installation of Trespa Meteon Metallics and Naturals 6Service and guarantee 6The technological quality 7The technical quality 8Faade applications 9Ventilated faade cladding 9Ventilation 10Fire precautions 10Joints 11Corner solutions 12General guidelines faade cladding 13Fixing systems 13General guidelines fixing systems 13TS150: Visible fixing with screws on a timber subframe 15TS700: Visible fixing with blind rivets on an aluminium subframe 19TS200: Invisible fixing with screws or inserts 25TS400: Invisible fixing with adhesive and screws 29TS300: Blind fixing using profiled edges 32TS650: Blind fixing with clips (Sidings) 33Panels in frames 35Single-skin panels in frames 35Sandwich panels in frames 37System 700 for overcladding 38Special fixings 39Building regulations 40Standards 40Auxiliary profiles 40Fixings 41Deflection 43Wind loads and load bearing 44Addresses 48Trespa International BVInt. Antwoordnummer 2508C.C.R.I. 25086014 ZX IttervoortNederlandPays-BasRPONSE PAYEPAYS-BASTrespa UK LtdGrosvenor HouseHollinswood RoadCentral ParkTelfordTF2 9TWBUSINESS REPLY SERVICELICENCE NO. NWW 165381Faade claddingFasciasSoffitsSingle-skin panelsSandwich panels ... la carte.exteriorU001Zandbeek Communication Group (NL) 0405/3.000All the best qualities in one panelQuality.Design la carte.VISIT OUR WEBSITEWWW.TRESPA.COMTrespa International BVFour perfect product linesConditions of SaleRegisteredtrademarksTrespa International BV specializes in highquality panel material for faade claddingand interior use. Trespa has both the expertiseand the means to develop products for specificsegments of the market. Trespa is continuallylooking for ways to protect the environmenteven more effectively.Production of the faade cladding materialTrespa Meteon is based on unique, patentedtechniques, which guarantee excellentweather resistance and colourfastness.Trespa Athlon, which offers you outstandingmoisture resistance along with scratch andwear resistance, is particularly suitable forinterior use. Trespa Virtuon is aestheticallypleasing and the perfect product for interiorapplications where durability, hygiene,cleanability are required. And TrespaTopLabPLUS, highly resistant to chemicalsand designed for use as laboratory worktops,completes the product programme.Trespa guarantees quality of both productsand services. We offer our customersoptimal technical support as well asstraightforward documentation. Proof ofthis approach is the award of the ISO 9001and ISO 14001 certificates. Whatever your requirements, Trespa offersa full support service. Please contact us forfurther information.To all our offers, quotations, sales, deliveriesand supplies and/or agreements, and to allrelated services and activities the TrespaInternational B.V. General Conditions ofSale apply, filed at the Venlo Chamber ofCommerce on 1 January 2004, registeredunder number 24270677, and appearing onthe website at www.trespa.com. The text ofthese General Terms and Conditions will besent to you upon request. Trespa, Meteon, Athlon, Toplab, Virtuon,Volkern, Ioniq and Inspirations are registeredtrademarks of Trespa International BV.Trespa UK LtdGrosvenor HouseHollinswood RoadCentral Park, TelfordTF2 9TWTel.: 44 (0) 1952 290707Fax: 44 (0) 1952 [email protected] International BVPostbus 110, 6000 AC WeertWetering 20, 6002 SM WeertThe NetherlandsVerkoop NederlandTel.: 31 (0) 495 458 850Fax: 31 (0) 495 540 [email protected] ExportTel.: 31 (0) 495 458 359 / 392 / 578 Fax: 31 (0) 495 458 383 [email protected] Asia/Pacific Sales SupportTel.: 31 (0) 495 458 538 Fax: 31 (0) 495 458 383 [email protected] Belgium Bvba/SprlH. van Veldekesingel 150 B. 193500 HasseltTel.: 0800 - 15501Fax: 0800 - [email protected] Duch de LuxembourgTel.: 31 (0) 495 458 308Trespa Deutschland GmbHEuropaallee 27, D-50226 FrechenTel.: 0800 - 186 04 22Fax: 0800 - 186 07 [email protected] France18 rue Chartran92200 Neuilly sur Seine Tel.: 33 (0) 1 41 92 04 80Fax: 33 (0) 1 41 92 04 [email protected] s.l.Gran Via, 680 tico 08010 BarcelonaTel.: 34 (93) 488 03 18Fax: 34 (93) 487 32 36www.getsl.com /[email protected] North America Ltd.12267 Crosthwaite CirclePoway, CA 92064Tel.: (1)-800-4-TRESPAFax: (1)[email protected] Japan Ltd.Toranomon Toyo Building 6F4-2 Toranomon, 1-chomeMinato-ku, Tokyo 105-0001Tel.: 81 (0) 3 3500 5080Fax: 81 (0) 3 3504 [email protected] China Co. Ltd.Room 2907, Plaza 66No. 1266 Nanjing Road (W)Shanghai 200040 P.R.C.Tel.: 86 (0) 21 6288 1299Fax: 86 (0) 21 6288 [email protected] Asia/PacificTel.: 86 (0) 21 6120 1011Fax: 86 (0) 21 6288 1022Trespa Singapore Pte Ltd.UOB Plaza 180 Raffles PlaceLevel 36 Room 37Singapore 048624Tel.: 65 6248 4613Fax: 65 6248 4613ResponsibilityAll information is based on our currentstate of knowledge. It is intended asinformation concerning our productsand their application possibilities, andis therefore not intended as any formof guarantee with regard to any specificproduct characteristic.ColoursThe colours in this document areprinted, and therefore, may varyslightly from the original Trespa panelcolours with respect to gloss, colourshades and surface texture. Originalsamples are available on request. Copyrights All rights reserved. No part of thispublication may be reproduced, storedin a retrieval system, or made public, inany form or by any means, eithergraphic, electronic or mechanical,including photocopying, recording orotherwise, without the prior writtenpermission of Trespa International BV.www.trespa.comAll the best qualities in one panelTrespa International BVInt. Antwoordnummer 2508C.C.R.I. 25086014 ZX IttervoortNederlandPays-BasRPONSE PAYEPAYS-BASTrespa UK LtdGrosvenor HouseHollinswood RoadCentral ParkTelfordTF2 9TWBUSINESS REPLY SERVICELICENCE NO. NWW 165381Faade claddingFasciasSoffitsSingle-skin panelsSandwich panels ... la carte.exteriorU001Zandbeek Communication Group (NL) 0405/3.000All the best qualities in one panelQuality.Design la carte.VISIT OUR WEBSITEWWW.TRESPA.COMTrespa International BVFour perfect product linesConditions of SaleRegisteredtrademarksTrespa International BV specializes in highquality panel material for faade claddingand interior use. Trespa has both the expertiseand the means to develop products for specificsegments of the market. Trespa is continuallylooking for ways to protect the environmenteven more effectively.Production of the faade cladding materialTrespa Meteon is based on unique, patentedtechniques, which guarantee excellentweather resistance and colourfastness.Trespa Athlon, which offers you outstandingmoisture resistance along with scratch andwear resistance, is particularly suitable forinterior use. Trespa Virtuon is aestheticallypleasing and the perfect product for interiorapplications where durability, hygiene,cleanability are required. And TrespaTopLabPLUS, highly resistant to chemicalsand designed for use as laboratory worktops,completes the product programme.Trespa guarantees quality of both productsand services. We offer our customersoptimal technical support as well asstraightforward documentation. Proof ofthis approach is the award of the ISO 9001and ISO 14001 certificates. Whatever your requirements, Trespa offersa full support service. Please contact us forfurther information.To all our offers, quotations, sales, deliveriesand supplies and/or agreements, and to allrelated services and activities the TrespaInternational B.V. General Conditions ofSale apply, filed at the Venlo Chamber ofCommerce on 1 January 2004, registeredunder number 24270677, and appearing onthe website at www.trespa.com. The text ofthese General Terms and Conditions will besent to you upon request. Trespa, Meteon, Athlon, Toplab, Virtuon,Volkern, Ioniq and Inspirations are registeredtrademarks of Trespa International BV.Trespa UK LtdGrosvenor HouseHollinswood RoadCentral Park, TelfordTF2 9TWTel.: 44 (0) 1952 290707Fax: 44 (0) 1952 [email protected] International BVPostbus 110, 6000 AC WeertWetering 20, 6002 SM WeertThe NetherlandsVerkoop NederlandTel.: 31 (0) 495 458 850Fax: 31 (0) 495 540 [email protected] ExportTel.: 31 (0) 495 458 359 / 392 / 578 Fax: 31 (0) 495 458 383 [email protected] Asia/Pacific Sales SupportTel.: 31 (0) 495 458 538 Fax: 31 (0) 495 458 383 [email protected] Belgium Bvba/SprlH. van Veldekesingel 150 B. 193500 HasseltTel.: 0800 - 15501Fax: 0800 - [email protected] Duch de LuxembourgTel.: 31 (0) 495 458 308Trespa Deutschland GmbHEuropaallee 27, D-50226 FrechenTel.: 0800 - 186 04 22Fax: 0800 - 186 07 [email protected] France18 rue Chartran92200 Neuilly sur Seine Tel.: 33 (0) 1 41 92 04 80Fax: 33 (0) 1 41 92 04 [email protected] s.l.Gran Via, 680 tico 08010 BarcelonaTel.: 34 (93) 488 03 18Fax: 34 (93) 487 32 36www.getsl.com /[email protected] North America Ltd.12267 Crosthwaite CirclePoway, CA 92064Tel.: (1)-800-4-TRESPAFax: (1)[email protected] Japan Ltd.Toranomon Toyo Building 6F4-2 Toranomon, 1-chomeMinato-ku, Tokyo 105-0001Tel.: 81 (0) 3 3500 5080Fax: 81 (0) 3 3504 [email protected] China Co. Ltd.Room 2907, Plaza 66No. 1266 Nanjing Road (W)Shanghai 200040 P.R.C.Tel.: 86 (0) 21 6288 1299Fax: 86 (0) 21 6288 [email protected] Asia/PacificTel.: 86 (0) 21 6120 1011Fax: 86 (0) 21 6288 1022Trespa Singapore Pte Ltd.UOB Plaza 180 Raffles PlaceLevel 36 Room 37Singapore 048624Tel.: 65 6248 4613Fax: 65 6248 4613ResponsibilityAll information is based on our currentstate of knowledge. It is intended asinformation concerning our productsand their application possibilities, andis therefore not intended as any formof guarantee with regard to any specificproduct characteristic.ColoursThe colours in this document areprinted, and therefore, may varyslightly from the original Trespa panelcolours with respect to gloss, colourshades and surface texture. Originalsamples are available on request. Copyrights All rights reserved. No part of thispublication may be reproduced, storedin a retrieval system, or made public, inany form or by any means, eithergraphic, electronic or mechanical,including photocopying, recording orotherwise, without the prior writtenpermission of Trespa International BV.www.trespa.comAll the best qualities in one panelNoteD147Yes,I would like to have more information:IIPlease call me for further information about ......................................................IIPlease call me for an appointment with your sales representativeIIOther,......................................................................................................................................................Company: ....................................................................................................................................................Name: ................................................................................................................................................M/FPosition: ........................................................................................................................................................Address: ........................................................................................................................................................Postal code: .....................................................Town: ......................................................................Country: .......................................................................................................................................................Telephone: .............................................................Fax: ......................................................................E-mail: ............................................................................................................................................................Please send the coupon to the address on the back or contact the Trespa sales organisation in your country (address on the back of this brochure).R E P L Y C A R DU001Yes,I would like to have more information:IIPlease call me for further information about ......................................................IIPlease call me for an appointment with your sales representativeIIOther,......................................................................................................................................................Company: ....................................................................................................................................................Name: ................................................................................................................................................M/FPosition: ........................................................................................................................................................Address: ........................................................................................................................................................Postal code: .....................................................Town: ......................................................................Country: .......................................................................................................................................................Telephone: .............................................................Fax: ......................................................................E-mail: ............................................................................................................................................................Please send the coupon to the address on the back or contact the Trespa sales organisation in your country (address on the back of this brochure).R E P L Y C A R DU001D12ContentsGeneral information 3Product data Trespa Meteon 4Application and delivery programme 5Fabrication and installation of Trespa Meteon Metallics and Naturals 6Service and guarantee 6The technological quality 7The technical quality 8Faade applications 9Ventilated faade cladding 9Ventilation 10Fire precautions 10Joints 11Corner solutions 12General guidelines faade cladding 13Fixing systems 13General guidelines fixing systems 13TS150: Visible fixing with screws on a timber subframe 15TS700: Visible fixing with blind rivets on an aluminium subframe 19TS200: Invisible fixing with screws or inserts 25TS400: Invisible fixing with adhesive and screws 29TS300: Blind fixing using profiled edges 32TS650: Blind fixing with clips (Sidings) 33Panels in frames 35Single-skin panels in frames 35Sandwich panels in frames 37System 700 for overcladding 38Special fixings 39Building regulations 40Standards 40Auxiliary profiles 40Fixings 41Deflection 43Wind loads and load bearing 44Addresses 48