ReferencesPower Generation Industry
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
2/75
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
3/75
Long-term protection of reinforced concrete structures
in power plants poses the highest demands on rehabilitation
and coating systems. Reliability of the structures long-term pro-
tection is a vital factor that ensures operational reliability of the
entire power plant.
Ongoing dialogue with planners and power plant opera-
tors and MCs own research and development has made the
company a reliable partner of the energy industry for more than
40 years when it comes to the protection of their concrete struc-
tures. Worldwide MC employees are developing project-specic
solutions, be it for the new construction or repair of cooling
towers, chimneys and reactor buildings.
In addition to the vastly differing demands from a struc-
tural point of view for each and every one of these structures,
impact from weather conditions which have to be assesseddifferently depending on the respective climate zone, demand
bespoke system solutions that are tailored to the respective
overall conditions of the project.
Complementary to the technical demands of such reha-
bilitation and surface protection systems, the aesthetic nish
of the power plants has become another important aspect.
Here, highly UV-resistant coating systems from MC make it pos-
sible to achieve complex colour designs.
This brochure gives you an overview of international
examples for the use of our system solutions for a diverse range
of power plant structures.
Investments of such signicance demand solutions that last!
Anja SpirresHead of Division Holger SchwarzeProtection Technologies
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
4/754
Product: Zentricryl RBSYear: 2007
Projectinformation: Already in 1993 until 1994 one of
the cooling towers at the nuclear
power plant Doel was repaired
on the inside and outside surfaces
with the tried-and-tested surface
protection system. Based on years
of good experiences with the com-
pany, MC-Bauchemie was again
called upon in 2006 when the
reactor building 1 needed to be
sealed. The particular challenge
in this case was finding a system
design with which the negative
pressure required for operations
could be achieved in the shortest
possible time and which could
maintain this pressure with the
available aggregates. In this
instance the system Zentricryl RBS
was applied.
Good cooperation resulted in
further building elements being
repaired, such as the cooling towersupports, for which Nafufill KM 250
was used.
BELGIUM, DOEL
Nuclear Power PlantDoel
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
5/755
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
6/756
BELGIUM, RUIEN
Coal-fired Power PlantRuienProduct: Nafufill KM 250,
EmceColor-flex
Year: 2008
Projectinformation: In 2008 the Nafufill KM 250 system
was successfully used to repair
damage to the chimneys.
The surface protection used in
this instance was EmceColor-flex.
Systems from MC-Bauchemie were
used in repairs of cooling towers
here as early as the 1990s.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
7/757
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
8/758
Product: Nafufill KM 250,Zentricryl RBS
Year: 2008
Projectinformation: Crack-bridging surface protection
was required to repair the dam-
aged exterior shells of this power
plants cooling towers. Following
the concrete repair works with
Nafufill KM 250 the surface protec-
tion system Zentricryl RBS with its
high crack-bridging properties was
therefore used in this case.
BELGIUM, VILVOORDE
Cogeneration PlantVilvoorde
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
9/759
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
10/7510
Product: Zentrifix F 82 XX,MC-DUR 1277 WV,
MC-DUR VS NR3,
MC-Schutzberzug 702
Year: 2008 / 2009
Projectinformation: In the construction of the new
cooling tower great emphasis
was placed on the surface protec-
tion of the concrete both inside
and outside right from the start.
Based on the analysis of the
expected operational loads an
important aspect here was the
feeding of flue gasses into the
cooling tower for the inside the
MC-DUR VS NR3 surface protec-
tion system was chosen, while
MC-Schutzberzug 702 protected
the outside shell.
BULGARIA, GALABOVO
Coal-fired Power PlantAES-3C Maritsa East 1
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
11/7511
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
12/7512
Product: MC-DUR 1800 TX,MC-DUR 1200 VK,
Zentrifix EC 6,
MC-DUR VS-PUR,
MC-DUR 1277 WV,
EmceColor-flex,
MC-702 SX
Year: 1992-1996 / 2007
Projectinformation: After two cooling towers were
successfully repaired on the inside
and outside using systems from
MC during 1992 to 1996, in 2007
it was the chimney that was refur-
bished with systems from MC.
CZECH REPUBLIC, CHVALETICE
Power Plant Chvaletice
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
13/7513
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
14/7514
Product: MC-Schutzberzug 702 SX,EmceColor-flex,
MC-DUR 1277 WV,
MC-DUR VS NR3,
MC-DUR VS-PUR
Year: 2002-2003
Projectinformation: During 2002 and 2003 a new chim-
ney was built. In its construction
MC after-treatment and long-term
protection systems were applied.
For more than a decade the cooling
towers of this plant have been main-tained and repaired with products
from MC, both inside and outside.
CZECH REPUBLIC, DETMAROVICE
Hard-Coal-fired Power PlantDetmarovice
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
15/7515
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
16/7516
Product: MC-DUR 1277 WV,MC-DUR VS NR3,
MC-Schutzberzug 702 SX,
EmceColor-flex
Year: 1997-1999 / 2005
Projectinformation: After all four cooling towers were
successfully protected inside and
two of them outside using MC pro-
ducts during 1997 to 1999, the same
systems were again used in 2005
for the surface protection of the
exterior shell of the two remaining
cooling towers.
CZECH REPUBLIC, TEMELIN
Nuclear Power PlantTemelin
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
17/7517
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
18/7518
Product: Zentrifix F 82 XX,MC-DUR 1277 WV,
MC-DUR VS NR3
Year: 2009
Projectinformation: For the cooling tower with flue
gas inlet for the new block of
this power plant near Beijing the
planner specified systems from
MC-Bauchemie based on previous
good cooperation with the com-
pany. The exterior surface protec-
tion was also carried out with MC
products.
PR CHINA, TIANJIN
Coal-fired Power PlantJulian Cheng
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
19/7519
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
20/7520
Product: Zentrifix F 82 XX,MC-DUR VS NR3,
MC-RIM F
Year: 2009
Projectinformation: For the two cooling towers of the
new power plant powered with
seawater the client stressed his
desire for lasting functionality of
the surface protection as the long
service life of the plant is para-
mount. Based on MC-Bauchemies
experience with similar projects
(Power Plant Rostock, SAFCO 4,
Shuaiba 2 and SHARQ3) planners
and principal opted for MC. This
also applies to the concrete protec-
tion for the outer shell. Another
reason for the successful coopera-
tion between everyone involved
was the regular support by MC
staff onsite.
PR CHINA, HANGU
Coal-fired Power PlantBeijiang
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
21/7521
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
22/7522
Product: Zentrifix F 82 XX,MC-DUR 1277 WV,
MC-DUR VS NR3,
MC-Schutzberzug 702
Year: 2006
Projectinformation: One of the largest cooling technol-
ogy service providers in Germany
recommended systems from MC
for this project. After intensive
consultations and the drafting of
an individual concept MC was
awarded the contract to supply
the surface protection systems
for the inside and the outside of
the towers.
The client was not only impressed
by MCs application technology but
also by excellent onsite support.
PR CHINA, BEIJING
Coal-fired Power PlantHuaneng
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
23/7523
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
24/7524
Product: Zentricryl RBS,EmceColor-flex S
MC-DUR 1277 WV
Year: 2003
Projectinformation: During the hot summer of 2003 the
repair of the hybrid cooling tower
posed a particular challenge. The
proven system MC-DUR 1277 WV
was used on the inside. Since high
loading by vibration caused by
ventilators is to be expected in this
cooling tower the highly crack-
bridging system Zentricryl RBS
was selected for the outside sur-
face protection. And due to the
great heat during that summer the
intended mineral levelling mortar
was not used, instead the applica-
tors were able to fall back on the
acrylate system Zentrifix CR finish,
which does not require any after-
treatment.
GERMANY, ALTBACH
Hard-Coal-fired Power PlantAltbach
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
25/7525
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
26/7526
GERMANY, BERGKAMEN
Coal-fired Power PlantBergkamenProduct: MC-DUR VS-EW,
MC-DUR 2103 M,
MC-FLEX 2098
Year: 2005
Projectinformation: The cooling tower had been
successfully restored inside and
outside with MC products in the
1990s, but also needed to be
toughened up at the chimneys
opening in 2005.
Of particular importance in this
case was to apply a crack-bridging
surface protection system at the
mouth of the chimney to comple-
ment extensive concrete repair
measures.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
27/7527
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
28/7528
GERMANY, BEXBACH
Coal-fired Power PlantBexbachProduct: Zentricryl RBS,
EmceColor-flex S
Year: 2004
Projectinformation: For the outer shell repair works
of this cooling tower particular
emphasis was put on the high
crack-bridging properties of the
surface protection system. For this
reason a combination of Zentricryl
RBS/EmceColor-flex S was used.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
29/7529
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
30/7530
GERMANY, BIBLIS
Nuclear Power PlantBiblisProduct: Nafufill KM 124,
Zentrifix F 92,
EmceColor-flex
Year: 1995
Projectinformation: For the outer repair of the cooling
towers a crack-bridging system
was required that was also used at
the reactor domes. Further building
components such as the cooling
tower basin, the office buildings
and the concrete fence were subse-
quently repaired with systems from
MC as well.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
31/7531
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
32/7532
GERMANY, BOXBERG
Coal-fired Power PlantBoxbergProduct: Zentrifix F 82 XX,
MC-DUR 1277 WV,
MC-DUR VS NR3
Year: 1998
Projectinformation: After several older cooling towers
had already successfully been
repaired with systems from MC,
it naturally followed that in the
construction of the new cooling
tower Q at the Boxberg power
plant, a surface protection was
preventatively applied inside using
the tried-and-tested systems from
MC because of the flue gas inlet.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
33/7533
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
34/7534
GERMANY, BRAUNSCHWEIG
Cogeneration PlantBraunschweigProduct: Nafufill KM 250,
MC-DUR 1200 VK,
MC-DUR VS EW,
MC-DUR 2103 M,
MC-FLEX 2099
Year: 2006
Projectinformation: After many years of operation the
top end including the so called
"down wash area" was partially
damaged and had to be repaired
and protected for coming decades
of maintenance free operation.
As this building is a landmark for
its surrounding the colouration of
the top coating was required in
best possible quality. In addition
the top coat MC-DUR 2103 M fulfils
moderate crack bridging for near
surface cracks.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
35/7535
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
36/7536
GERMANY, CHEMNITZ
Hard-Coal Power PlantChemnitzProduct: Nafufill GTS-HS,
Zentricryl RBS,
EmceColor-flex,
MC-DUR 1277 WV,
MC-DUR VS NR3
Year: 2008
Projectinformation: Preliminary tests found high sul-
phate content in the concrete of
the cooler to be repaired, which
prompted the use of Nafufill
GTS-HS as concrete replacement
system. Because of the risk of
crack formation Zentricryl RBS
and EnceColor-flex were used on
the outside. Inside the traditional
structure with MC-DUR 1277 WV
and MC-DUR VS NR3 was used.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
37/7537
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
38/7538
GERMANY, ESSEN
Waste-to-Energy PlantEssen-KarnapProduct: Zentrifix F 82 XX,
MC-DUR VS,
MC-DUR VS-PUR,
Betonflair
Year: 1990
Projectinformation: This chimney, a landmark for the
Ruhr region, was protected with
systems from MC-Bauchemie when
it was newly built.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
39/7539
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
40/7540
Product: Nafufill GTS,Zentricryl GS 2000,
EmceColor-flex
Year: 2005
Projectinformation: In the case of this chimney it was
especially important to ensure an
economical and reliable application
of the products. By way of consist-
ently using a levelling mortar on
acrylate basis that did not require
any after-treatment the works could
be completed within the scheduled
timeframe. In the following year a
further cooling tower was success-
fully repaired on the outside based
on the same system.
GERMANY, GELSENKIRCHEN
Coal-fired Power PlantGelsenkirchen-Scholven
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
41/7541
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
42/7542
GERMANY, GRAFENRHEINFELD
Nuclear Power PlantGrafenrheinfeldProduct: Zentricryl RBS,
EmceColor-flex
Year: 1999 / 2000
Projectinformation: Following extensive tests and
sample productions during the
planning stage in 1998 the reactor
dome was repaired successfully.
At a later date the cooling tower
basin was also sealed.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
43/7543
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
44/7544
GERMANY, HEILBRONN
Cogeneration PlantHeilbronnProduct: Nafufill KM 250,
Betonflair Uniprimer,
EmceColor-flex
Year: 2009
ProjectInformation: The tried-and-tested, crack-bridging
and vapour-diffusion open system
EmceColor-flex was used for the
surface protection of the exterior of
this cooling tower.
Due to the condition of the sub-
strate and based on its good work-
ability Betonflair Uniprimer was
applied first.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
45/7545
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
46/7546
Product: Zentrifix F 82 XX,MC-DUR 1277 WV,
MC-DUR VS NR3,
MC-Schutzberzug 702
Year: 1996 / 1997
Projectinformation: The chimney was repaired using
proven systems after having been
inspected thoroughly. Particularly
challenging was here the existing
epoxy resin paint at the opening,
which could not be removed
completely. The application was
adapted jointly with owner,
planer and applicator to suit the
local conditions.
GERMANY, IBBENBREN
Hard-Coal-fired PowerPlant Ibbenbren
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
47/7547
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
48/7548
GERMANY, LIPPENDORF
Lignite-fired Power PlantLippendorfProduct: Zentrifix F82 XX,
MC-DUR 1277 WV,
MC-DUR VS NR3
Year: 2001
Projectinformation: Preventative surface protection
for both cooling towers had been
applied before they were put into
operation. The interior of the shells
had been protected against opera-
tional load impact, in this case a
mixture of cooling tower plume
and flue gas condensation. The
shell exterior was protected against
the impacts from the atmosphere.
Each side of the tower shell has a
surface of approximately 45,000 m.
After 7 years of more or less unin-
terrupted operation the coating
system on the inside of one of the
two cooling towers was inspected
by an expert. The inspection report
certified that under continuous
operation the service life of the
surface protection is expected to
be at least 20 years.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
49/7549
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
50/7550
Product: Zentricryl RBS,EmceColor-flex
Year: 2004 / 2008-2009
Projectinformation: After the cooling tower had been
successfully repaired with the use
of MC systems, the restoration of
the reactor building 2 was realised
in 2008 and 2009.
GERMANY, NECKARWESTHEIM
Nuclear Power PlantNeckarwestheim
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
51/7551
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
52/7552
GERMANY, NEURATH
Lignite-fired Power PlantNeurathProduct: Nafufill GTS,
Zentrifix F 82 XX,
MC-DUR VS NR3,
MC-DUR 2203
Year: 2007-2009
Projectinformation: During 2007 to 2009 several cool-
ing towers with flue gas inlets
were again toughened up using
new and more effective concepts.
In this instance, besides the con-
crete repair particular emphasis
was placed on a functioning
interior shell surface protection
system with sealed off pores,
which would protect the interior
effectively until the end of its life-
span. Of particular importance was
UV protection above the waistline.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
53/7553
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
54/7554
Product: Nafufill GTS,Zentrifix F 82 XX,
MC-DUR VS NR3,
MC-DUR 2203
Year: 2007-2009
Projectinformation: Based on the technical prepara-
tions and experiences in the power
plants Weisweiler and Neurath
newer, more efficient toughening
concepts were developed for the
repair of the interior shell. After the
cooling towers of this power plant
had during the 1990s already been
protected against the aggressive
impact of the flue gases fed in, MC
systems were again applied in this
repair measure.
GERMANY, NIEDERAUSSEM
Lignite-fired Power PlantNiederauem
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
55/7555
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
56/7556
GERMANY, ROSTOCK
Hard-Coal-fired Power PlantRostockProduct: Zentrifix F 82 XX,
MC-DUR VS NR3,
MC-Schutzberzug 702
Year: 1992
Projectinformation: This power plant was the first
new-built power plant in the new
federal states after reunification.
It is also the first power plant in
Germany where the cooling tower
is operated by sea-water (other
power plants with this technology
started operations in Saudi Arabia
and in Kuwait between 2002 and
2008). Another important consider-
ation is the fact that the operation
uses flue gas inlets here as well.
Due to the heavy load impact that
this entails surface protection with
systems from MC-Bauchemie
became necessary.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
57/7557
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
58/7558
GERMANY, SPREMBERG
Lignite-fired Power PlantSchwarze PumpeProduct: Zentrifix F 82 XX,
MC-DUR VS NR3,
MC-Schutzberzug 702
Year: 1994-1995
Projectinformation: In the new construction of blocks
A and B of the brown-coal-fired
power plant Schwarze Pumpe
effective concrete protection for
the interior shell was included in
the planning right from the start
because of flue gas inlets; this was
performed using the MC systems
MC-Schutzberzug 702 (outside)
and MC-DUR VS NR3 (inside).
An overhaul of the interior surfaces
above the waistline was carried out
in 2009 for one of the towers, the
second cooling tower is planned
to also receive a cover coat with
UV-resistant polyurethane in 2010.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
59/7559
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
60/7560
Product: Nafufill GTS,Zentrifix F 82 XX,
MC-DUR VS NR3,
MC-DUR 2203
Year: 2007-2009
Projectinformation: Because of intensive operational
loading of the cooling towers with
flue gas inlets damages occurred
despite several surface protection
measures having been carried out
during the 80s and 90s. A com-
pletely new concept of repair and
surface protection including partial
static strengthening was therefore
developed by a team of experts,
with instrumental support from
MC-Bauchemie. As a result all
cooling towers of the power plant
(amongst them block G) are being
toughened with systems from MC.
GERMANY, WEISWEILER
Lignite-fired Power PlantWeisweiler
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
61/7561
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
62/7562
Product: MC-DUR 1277 WV,MC-FLEX 2099,
MC-DUR VS NR3,
MC Schutzberzug 702
Year: 2008-2009
Projectinformation: After several cooling towers and
chimneys of the existing power
plant were already repaired suc-
cessfully with MC products during
the 1990s, MC products were again
used in the new construction of
another cooling tower.
Additionally, special colours were
required for the design of the exte-
rior shell.
POLAND, BELCHATOW
Lignite-fired Power PlantBelchatow
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
63/7563
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
64/7564
POLAND, KATOWICE
Power Plant Laziska
Product: Zentrifix KMH,Nafufill KM 250,
MC-DUR 1277 WV,
MC-DUR VS NR3,
MC-DUR VS-PUR
Year: 2008
Projectinformation: For this cooling tower it was par-
ticularly important to repair the shor-
ing in the water distribution level
and the cooling tower basin. First of
all the concrete was repaired using
the tried-and-tested Nafufill KM 250
system, followed by the surface
protection system MC-DUR VS NR3
combined with MC-DUR VS-PUR.
Both chimneys were also repaired
in this power plant, for which MCs
surface protection systems matched
to the respective load scenarios
were used.
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
65/7565
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
66/7566
Product: Zentrifix KMH,Zentrifix GM2,
MC-DUR 1277 WV,
MC-DUR VS
MC-Schutzberzug 702 SX,
Betonflair W
Year: 1998
Projectinformation: In this plant the cooling tower was
successfully repaired with MC
products on the inside and outside.
Whats worth mentioning here is
that the colour design for the outer
surface was done by the children
from the primary school in Opole.
POLAND, OPOLE
Power Plant Opole
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
67/7567
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
68/7568
Product: Nafufill KM 250,Betonflair Uniprimer,
EmceColor-flex,
MC-DUR 1277 WV,
MC-DUR VS NR3,
MC-CFK Sheets
Year: 2007-2009
Projectinformation: Following extensive inspections
that identified a rather thin con-
crete cover it was decided to repair
one cooling tower of this power
plant with the PCC mortar Nafufill
KM 250, which is statically creditable.
Surface protection was then applied
with the EmceColor-flex system.
The inside surface was also repaired
and was protected with the proven
system MC-DUR VS NR3. Of great
importance in this case was the
static strengthening of the cooling
towers with MC-CFK sheets.
Another special feature was the col-
our design, luminous rings painted
with RAL 3000.
ROMANIA, IERNUT
Power Plant Iernut
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
69/7569
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
70/7570
Product: MC-Schutzberzug 702,MC-DUR VS,
MC-DUR VS-PUR
Year: 2007
Projectinformation: In this project during new con-
struction the proven products
from MC-Bauchemie were also
being used. The deciding factor
here was the possibility of concrete
after-treatment in slip form con-
struction with integrated long-term
protection.
RUSSIA, RYAZAN
Power Plant Ryazan
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
71/7571
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
72/7572
Product: MC-Schutzberzug 702Year: 2008
Projectinformation: Recoating of the smoke band to
provide protection from chemical
attack and to create an aesthetically
pleasing finish. MC-Schutzberzug
702 was selected as this product
provides very short drying times
between coats a requirement
in order to minimise moving the
access platforms.
UNITED KINGDOM, FAWLEY
Petrochemical ManufacturingPlant ExxonMobil
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
73/7573
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
74/75
-
7/29/2019 Referinte Turnuri de Racire Si Cosuri de Fum
75/75