prezentare lrp

37
7/30/2019 Prezentare LRP http://slidepdf.com/reader/full/prezentare-lrp 1/37 L R L i n e a r R o d P ump Training sistem pompare LRP © 2012 ALFERA Toate drepturile rezervate 1/37 Sistem revolutionar de actionare a pompelor clasice de extractie titei

Upload: toth-otto

Post on 14-Apr-2018

286 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 1/37

L R P 

L i n e a r R o d P u m p  

Training sistem pompare LRP

© 2012 ALFERA Toate drepturile rezervate

1/37

Sistem revolutionar 

de actionare apompelor clasice

de extractie titei

Page 2: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 2/37

© 2012 ALFERA Toate drepturile rezervate

Training sistem pompare LRP

© 2012 ALFERA Toate drepturile rezervate

2/37

TEMATICA

1. Prezentare generala LRP2. Prezentare generala convertizor frecventa3. Prezentare tabloul electric4. Montajul electric5.

Date tehnice6. Parametrii aplicatie7. Testele necesare pornirii unitatii8. Pornirea efectiva a LRP-ului

  9. Dinamograme, optimizare si setare faulturi10. Identificare faulturi

11. Faulturi12. Operare LRP13. Mentenanta LRP

Page 3: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 3/37

  LRP – Linear Rod Pump - Permite operare in mod optimizat cuviteza de pompare variabila

- Mod de instalare simplu

- Modul optimizat permite eficientizareaenergetica si reduce uzura echipamentelor 

- Afisarea debitului instantaneu

- Afisarea productiei totale de la instalare

- Transmiterea datelor la distanta

© 2012 ALFERA Toate drepturile rezervate

3/37

Training sistem pompare LRP

Page 4: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 4/37

  LRP – Linear Rod Pump 

- Diferite dimensiuni: lungime cursa, sarcina.

- Miscarea este rectilinie verticala

- Unitatea consuma energie doar la cursa ascendenta,la coborare motorul intra in regim de generator 

-Energia aparuta suplimentar la cursa in jos estedisipata pe o rezistenta montata pe cabina.

Training sistem pompare LRP

© 2012 ALFERA Toate drepturile rezervate

4/37

Sarniera

Cremaliera

Pinionul care actioneazacremaliera

Reductorul

Baia de ulei

Tija polizata

Motorul

Suportul

Page 5: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 5/37

  Suportul unitatii 

Poate fi de diferite tipuri:

- De diferite inaltimi

- Flansa de baza: 71/16 si 11 inch

Observatie : Inainte de montajul mecanic se va verifica dacaflansa suportului se potriveste cu flansa de deasupra tubinghead. Daca nu se potriveste trebuie facut un adapter sau schimbat tubing head-ul

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

5/37

Page 6: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 6/37

  Unitatea LRP

 

- In figura este prezentat punctul de ridicare al unitatii

- Unitatea se prinde de suport in 4 sau 6 prezoane

Observatie : Atentie la modul de asezare al unitatii :Daca inca mai exista o unitate clasica trebuie atentie lalegaturile motorului, senzorului si termistorului

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

6/37

punct de ridicare

Page 7: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 7/37

  Capacul unitatii LRP - Folosit in special pentru a proteja cremaliera si uleiul din interiorul unitatii

- Moduri de fixare:

- In 8 suruburi in cazul LRP-urilor de 100”

- Direct, in cazul unitatilor mai mici de 100"

Observatie :

In cazul LRP mai mici de 44” capacul este compus din doua bucati

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

7/37

Page 8: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 8/37

  Convertizor de frecventa UNICO - Reglarea turatiei motoarelor asincrone

- Modificarea turatiei se faca prin reglarea tensiunii sia frecventei - Convertizorul Unico pentru cabinele de actionare aleLRP-urilor este pentru o alimentare cu maxim 575 V

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

8/37

Page 9: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 9/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

9/37

Page 10: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 10/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

10/37

Page 11: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 11/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

11/37

Page 12: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 12/37

  Legaturi motor  - Cablul de alimentare al motorului este numerotat

- Termistorul se leaga in clemele din dreapta 

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

12/37

Page 13: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 13/37

 Senzorul -La LRP mai mici de 100” se infileteazasenzorul pana ajunge la cremalieradupa care se da inapoi trei turecomplete ( de 360 grade) dupa care se

fixeaza cu piulite

- La LRP 100” montarea se face :Se masoara distanta pana la cremalierasi se scad 1.59 cm,dupa care se introduce acea

lungime si se fixeaza cu cele doua piulite

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

13/37

Page 14: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 14/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

14/37

Page 15: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 15/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

15/37

L 381C-256E-056

L =Linear Rod Pump

381 =torsiunea la axul reductorului (inch lbs)

C =raport de transmisie reductor (26,32:1)

256E =tipul motorului (20hp=15kw Ex)

056 =lungimea cursei unitatii (56inch=1,4m)

RR =echipare cu rotator 

ROO =numar revizii ale LRP

Page 16: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 16/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

16/37

Page 17: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 17/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

17/37

Page 18: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 18/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

18/37

Quickstart[base rpm]Quickstart [motor max rpm]Quick Start[torque limit]Quickstart [gear ratio]Quickstart [unit rtd rod load]Quickstart [unit rtd stroke]Quickstart [unit rtd torque]Quickstart [db resistance]Quickstart [db watts]Quickstart [linear lead]Quickstart [structural imbalance]Quickstart [ref input polarity]Motor  [motor rtd power]Motor [motor rated voltage]

Motor [motor rated current]

Rod/Pump [pump depth]

Rod/Pump [tubing anchor depth]Rod/Pump [average perf depth]Rod/Pump [tubing outer diameter]Rod/Pump [casing inner diameter]Rod/Pump [tubing pressure]Rod/Pump [casing pressure]Rod/Pump [plunger diameter]

Rod/Pump [plunger length]Rod/Pump [rod sections]Rod/Pump [rod 1 length]Rod/Pump [rod 1 diameter]Rod/Pump [rod 2 length]Rod/Pump [rod 2 diameter]Rod/Pump [rod length]

Rod/Pump [water cut]Rod/Pump [oil gravity]Rod/Pump [water specific gravity]

DATE TEHNICE

Page 19: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 19/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

19/37

Pentru pornirea unitatii sunt necesare urmatoarele teste:

- AC TEST ( test motor )

- Stroke ID ( test directie) – Setup Menu -> Quickstart-> SrokeIDEnable -> Enable

- Well ID ( Test unitate)

Setup Menu -> Quickstart-> SrokeIDEnable -> OverrideSetup Menu -> Quickstart -> SrokeIDLength -> LengthSetup Menu -> Quickstart -> Well IDEnable -> Enable

Page 20: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 20/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

20/37

Dupa parcurgerea testelor urmeaza pornirea LRP-ului.

Pornirea se face in modul single speed cu 3 spm.

Pump speed -> speed mode select -> single speedPump speed -> Keypad up spm

-Se verifica daca pompa are sau nu bataie ( daca are bataie se elimina si se reporneste).

- Se mareste viteza catre viteza maxima posibila pentru a vedea functionareaLRP-ului (vibratii, miscare).- Daca LRP-ul functioneaza normal se opreste unitatea si se pune capacul.- Se reporneste si se lasa in functiune pana cand sonda produce la gura putuluidupa care se fac ultimele setari la valori normale de functionare.

Page 21: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 21/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

21/37

Dupa ce sonda a inceput sa produca urmeaza efectuarea unor modificari asupra dinamogramelor 

Page 22: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 22/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

22/37

Optimizari

Meniul Optimizer ( Dictionary -> Optimizer)

Up maximum spmDown maximum spmUp minimum spmDown minimum spmOptimz target fillOptimz shutoff fillOptimz start spmOptimz min shutoff Speed mode select -> Optimize Speed

Page 23: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 23/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

23/37

Setari faulturi dinamograma

Page 24: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 24/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

24/37

Setari faulturi

Restart

Fault/Event[powerup restart delay] - 0,1 … 0,2Fault/Event [restart attemps] - 3Fault/Event [restart min delay] - 0,1Fault/Event [starting fault delay]

-0,1

Faultul de termistor 

Digital I/O [digital in 5 select] user flt 1Digital I/O [user 1 fault restart delay] 15 min

Parola : Nivelul si numarul sondei ( Level 2 password , sonda 333 - 2333)

Page 25: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 25/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

25/37

Identificare faulturi :

- Low rod load fault ( sarcina mica latija polizata-> e posibil sa fie garnitura detiji incompleta)

- High rod load fault ( sarcina prea mare

la cursa in sus -> pompa gripata, tijiBlocate, nisip in sonda, ventil inchis pelinie )

- Low pump load ( sarcina prea mica pepistonul pompei, supapa spiruita, tubingneetans)

- Rod load span ( diferenta prea mica intre limitele maxime si minime ale dinamogramei de suprafata )

Page 26: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 26/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

26/37

Identificare faulturi :

- Power loss parked - > lipsa tensiune, unitate parcheaza

- Bus overvoltage -> supraincarcare a bus-ului de c.c., tensiune prea mare la intrare,nefunctionare corecta a rezistentei, putere prea mare dezvoltata la cursa in jos

- user 1 – motor supraincalzit, declanseaza termistorul

- Gate driver dsat – se verifica motorul, contactati distribuitorul local

- External stop – s-a supraincalzit rezistenta, verificati termostatul

- Dynamic brake limit – s-a depasit limita rezistentei

Page 27: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 27/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

27/37

Identificare faulturi :

- Position error fault – tronsonul de tiji este blocat sau pompa este gripata,

unitatea blocata, motorul nu mai functioneaza

- Velocity error fault – tronsonul de tiji este blocat sau pompa este gripata,unitatea blocata, motorul nu mai functioneazai

Page 28: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 28/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

28/37

Identificare faulturi :

Ref input loss fault :

Dictionary -> Pumping Unit -> ref window tolDictionary -> Pumping Unit -> ref position upDictionary -> Pumping Unit -> ref position down

Dictionary -> Pumping Unit -> meas ref position

Se verifica si se curata senzorul

Se scoate senzorul si se pune langa o bucata de fier si se verifica contactul releului( cand este langa aproape de fier trebuie sa se faca releul si cand este indepartat releulnu trebuie sa se faca)

Se verifica cablul senzorului

Page 29: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 29/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

29/37

Operare LRP:

Vizualizare dinamograme

Setup Menu -> 8. Chart display -> Surface DynacardSetup Menu -> 8. Chart display -> Downhole Dynacard

Observatie : Afisarea dinamogramei pompei dureaza cateva secunde

Page 30: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 30/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

30/37

Operare LRP:

Numarul de ore de functionare cu motorul pornit si energia consumata pot fi vizualizate :

Setup Menu -> Operator -> Cumulative run hours (22)Setup Menu -> Operator -> Input power meter (20)

Page 31: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 31/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

31/37

Operare LRP:

- Bataia in riter Dictionary -> Pumping unit -> Snug auto initiateLa cate curse duble sa faca bataia in ritter Dictionary -> Pumping unit -> Snug auto expireCate batai sa faca in riter 

- Testul de supapeDictionary -> Valve Check -> Valve check enable -> EnableDupa terminarea testului de supape se urmaresc parametrii:- Tv static leak ( pierderi la supapa mobila)- Sv static leak ( pierderi la supapa fixa)- Tv load change ( sarcina pe supapa mobila)

-Sv load change ( sarcina pe supapa fixa)

 Acesti parametrii se regasesc in meniul valve check

Page 32: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 32/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

32/37

Mentenanta LRP:

- Verificare motor 

- Verificare blocare unitate antrenare( se da capacul unitatii jos, se monteaza o sarniera pe gura

putului, se demonteaza sarniera care a sustinut initial sarcina)Se desface aparatoarea ventilatorului motorului, dupa care se invarte de paletii ventilatorului pentrua vedea daca unitatea este blocata si eventual cum arata cremaliera

- Verificare senzor -> senzorul se desface si se curata, verificare cablu

Page 33: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 33/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

33/37

Mentenanta LRP:

Schimbare ulei:

- Ulei cremaliera 6 luni (SAE 85W-90 - 32-56 “ , la 100 “ - OMV gear oil SHG 220)- Ulei reductor 12 luni (OMV gear oil SHG 220)- Gresare rulmenti pinion de antrenare cremaliera - 3 luni

Setup Menu -> Dictionary -> MaintenanceVerificare dupa numarul de curse

- Maintenance gearbox lube- Maintenance gearbox count- Maintenance rack lube- Maintenance rack count- Maintenance reset

Observatie: Dupa schimbul de ulei trebuie resetata numaratoarea

Page 34: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 34/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

34/37

Montaj mecanic LRP:

- Se efectueaza fereastra pompei, este necesar sa avem cupoane de potrivire de diferite lungimi- Se masoara lungimea unitatii, suportului. Exemplu: unitatea 44 inch

- Lung. Unitate: 2,20 m- Lung. Suport : 1,70 m- Lung. Sarniera si distantier: 0,3 m- Lung. Totala: 4,2 m

 Aceasta trebuie sa fie lungimea minima a tijei polizate de la flansa tubing head-ului pana in varf Lungimea tijei polizate de deasupra cremalierei este limitata de lungimea capacului( nu trebuie sa fie mai mult 60 cm + lungimea de cursa)

 ATENTIE :- Dupa efectuarea ferestrei pompei ( pistonul in pozitie optima de lucru) se suspendagarnitura de prajini cu o sarniera montata pe gura putului

- Trebuie prevazuta posibilitatea de a ridica tronsonul de tiji in cazul in carefereastra pompei nu este corect efectuata

Page 35: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 35/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

35/37

Montaj mecanic LRP:

-Dupa efectuarea ferestrei pompei

Se demonteaza prezoanele de la flansa tubing head-ului

 ATENTIE : suportul trebuie fixat perfect pe flansa tubing headului in cele 4 prezoane,aceste prezoane trebuiesc sa fie mai lungi pentru a cuprinde si grosimea flansei suportului

- Suportul are o degajare care se va monta in directia liniei de amestec

- Pentru unitatile de 32”, 44”, 56” tija polizata este 32 mm(1 ¼”)- La unitatea de 100” tija polizata va fi de 38 mm ( 1 ½”), in acest caz va fi nevoie de doua tiji polizate

( una de lungime normala si cealalta de aproximativ 4 m, intre ele va fi efectuat filet flush)

Page 36: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 36/37

Training sistem pompare LRP

 © 2012 ALFERA. Toate drepturile rezervate.

36/37

Montaj mecanic LRP:

 ATENTIE :

- Tija polizata trebuie sa fie concentrica cu gaura de la partea superioara a suportului.In caz contrar tija polizata va freca in interiorul tubului cremalierei. Se pot folosi distantierepentru a efectua aceasta concentricitate

- suportul trebuie sa fie fix pe flansa capului de pompare

- atentie la cabluri si senzorul in cazul in care se leaga de jos legaturile la motor, termistor si senzor 

- la modul de fixare al unitatii: pozitia motorului

- trebuie verificat uleiul de la cremaliera si reductor, daca nu este suficient se completeaza

Page 37: Prezentare LRP

7/30/2019 Prezentare LRP

http://slidepdf.com/reader/full/prezentare-lrp 37/37

Training sistem pompare LRP

Montaj mecanic LRP:

- Se monteaza unitate deasupra suportului

Se poate efectua in doua moduri:- Pe deasupra tijei polizate- Cu tija polizata introdusa in interiorul cremalierei

- Se monteaza prezoanele dintre suport si unitate.

- Se introduce distantierul pe la partea superioara a tijei polizate

- Se monteaza sarniera deasupra distantierului.

- Se demonteaza sarniera de pe gura putului.

- Se poate efectua pornirea unitatii.

- Dupa efectuarea testelor aferente pornirii se poate pune capacul unitatii .

punct de ridicare