manual de utilizare avtm672001 pentru trusa automata de … 2000 v4.0.pdf · manual de utilizare...

114
MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE TRUSA AUTOMATA DE TRUSA AUTOMATA DE TRUSA AUTOMATA DE MASURARE MASURARE MASURARE MASURARE CAPACITATI SI TANGENTA DE CAPACITATI SI TANGENTA DE CAPACITATI SI TANGENTA DE CAPACITATI SI TANGENTA DE DELTA DELTA DELTA DELTA DELTA 2000 DELTA 2000 DELTA 2000 DELTA 2000 DELTA 2000 DELTA 2000 DELTA 2000 DELTA 2000 Catalog nr. 672001 Echipament de inalta tensiune Cititi intreg manualul inainte de utilizare

Upload: dangnguyet

Post on 17-Apr-2018

282 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

MANUAL DE UTILIZARE AVTM672001PENTRU

TRUSA AUTOMATA DETRUSA AUTOMATA DETRUSA AUTOMATA DETRUSA AUTOMATA DEMASURAREMASURAREMASURAREMASURARE

CAPACITATI SI TANGENTA DECAPACITATI SI TANGENTA DECAPACITATI SI TANGENTA DECAPACITATI SI TANGENTA DEDELTADELTADELTADELTA

DELTA 2000DELTA 2000DELTA 2000DELTA 2000DELTA 2000DELTA 2000DELTA 2000DELTA 2000

Catalog nr. 672001

Echipament de inalta tensiuneCititi intreg manualul inainte de utilizare

Page 2: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

DACOM IMPEX S.R.L. V4.0

2

Page 3: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

CUPRINSCUPRINS

SECTIUNEA I MANUAL DE UTILIZARE DELTA 2000.......................................... 5

Capitolul 1 INTRODUCERE..................................................................................... 6Instructiuni de receptie......................................................................................... 6Generalitati........................................................................................................... 6Caracteristici importante....................................................................................... 7

Capitolul 2 AVERTISMENTE................................................................................... 9

Capitolul 3 CARACTERISTICI TEHNICE............................................................... 12Caracteristici electrice....................................................................................... 12Conditii de mediu............................................................................................. 14Date fizice ........................................................................................................ 15Accesorii furnizate...............................................................................................17Accesorii optionale..............................................................................................17

Capitolul 4 COMENZI, INDICATORI, CONECTORI.............................................. 19Panoul unitatii de comanda............................................................................... 19Conectorii unitatii de comanda.......................................................................... 22Conectorii unitatii de inalta tensiune.................................................................. 24

Capitolul 5 SETARE SI OPERARE........................................................................ 25Instructiuni de protectie...................................................................................... 25PIF ( SETUP)..................................................................................................... 26Descrierea ecranelor meniu si a celor de test.................................................. 30Masuratori (capacitate si tan delta).................................................................... 41Masurarea curentului de excitatie la transformatoare........................................ 45

Capitolul 6 Intretinere............................................................................................ 49Calibrare............................................................................................................. 49Reparatii............................................................................................................. 59Piese de schimb................................................................................................. 60Glosar................................................................................................................. 61Garantie............................................................................................................. 62

SECTIUNEA II DATA KEY - PROGRAM DE DESCARCARE.............................. 63

Introducere........................................................................................................ 64Drepturi.............................................................................................................. 64Cerinte Calculator.............................................................................................. 65Instalare..............................................................................................................65Setarile portului serial.........................................................................................65Formatul fisierelor de date..................................................................................65

DACOM IMPEX S.R.L. V4.0

3

Page 4: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Incarcarea datelor din memoria Data Key..........................................................66Stergerea memoriei Data Key.............................................................................67Vizualizarea si editarea datelor...........................................................................67Suport..................................................................................................................68

SECTIUNEA III APLICATII SI EXEMPLE............................................................. 71

Capitolul 1 INTRODUCERE.................................................................................. 72Principii de operare............................................................................................ 72Relatii intre curent, capacitate si tangenta de delta.................................... 76Scheme de conexiuni pentru modurile de test UST/GST................................... 79

Capitolul 2 INTERPRETAREA REZULTATELOR................................................ 84Semnificatia capacitatii si a tangentei de delta.................................................. 84Tangenta de delta pentru cateva tipuri de izolatii............................................... 86 Permitivitatea si tangenta de delta % pentru materiale izolante tipice............. 87Semnificatia temperaturii.................................................................................... 88Semnificatia umiditatii......................................................................................... 89Scurgerile de suprafatan.................................................................................... 90Interferentele electrostatice................................................................................ 90Tangenta de delta negativa................................................................................ 92

Capitolul 3 TIPURI DE ECHIPAMENTE................................................................. 93Transformatoare................................................................................................. 93Intrerupatoare..................................................................................................... 99Izolatori............................................................................................................. 105Teste cu "Inel cald"........................................................................................... 107Testele bornelor de tan delta sau capacitate................................................... 108Masini rotative.................................................................................................. 109Cabluri.............................................................................................................. 111Descarcatoare.................................................................................................. 112Lichide.............................................................................................................. 114Componente si subanasamble......................................................................... 114

DACOM IMPEX S.R.L. V4.0

4

Page 5: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

SECTIUNEA ISECTIUNEA I

MANUAL DE UTILIZARE MANUAL DE UTILIZARE

DELTA 2000DELTA 2000

DACOM IMPEX S.R.L. V4.0

5

Page 6: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Capitolul 1Capitolul 1

INTRODUCEREINTRODUCERE

INSTRUCTIUNI DE RECEPTIEINSTRUCTIUNI DE RECEPTIEINSTRUCTIUNI DE RECEPTIEINSTRUCTIUNI DE RECEPTIE Verificati echipamentul primit conform listei de specificatii pentru a va asigura catoate materialele sunt prezente. Notificati catre AVO International sau DACOMImpex orice lipsa. Tel 01 3236565; Fax: 01 3209132 Bucuresti.Examinati aparatul pentru deteriorari in timpul transportului. Daca apar deteriorariintocmiti imediat proces verbal impreuna cu transportatorul si anuntati imediat SCDACOM IMPEX SRL, informand detaliat asupra naturii defectelor.Aparatul a fost in intregime testat si inspectat inaintea expedierii. Este gata pentru afi folosit daca este pus in functiune conform instructiunilor acestui manual.

GENERALITATIGENERALITATIGENERALITATIGENERALITATI

Setul de test automat pentru capacitati si tangenta de delta DELTA 2000 sefoloseste in laboratoare si pe teren pentru testarea sistemului de izolatii aleechipamentelor de inalta tensiune. Rezultatele masuratorilor se folosesc pentru aevalua calitatea elementelor si materialelor izolatoare, oferind informatii desprecontaminari (apa, praf, etc.), fisuri, strapungeri si alte defecte care insotescimbatranirea izolatiilor.Setul de test cuprinde unitatea de comanda (UC), unitatea de inalta tensiune,cabluri, sacose pentru transportarea cablurilor, cutii de transport.Setul de test automat masoara tangenta de delta si capacitatea izolatiilor electriceale echipamentelor electrice de inalta tensiune ca: izolatori, cabluri, intrerupatoare,transformatoare, masini electrice rotative, condensatori si descarcatoare. Aparatul masoara modificarile capacitatii si ale pierderilor dielectrice datoratevariatiilor de tensiune si ale conditiilor ambientale ca: variatii de temperatura,umiditate, presiune, socuri mecanice, vibratii si suprasarcini. De asemenea masoaracurentul de excitatie (de magnetizare) al transformatoarelor. Sistemul de testrealizeaza toate tipurile de teste UST (izolatori neimpamantati, adica punteaSchering directa) si GST (izolatori impamantati i.e. puntea Schering inversa)necesare masurarilor echipamentelor de inalta tensiune.Sapte taste aflate pe U.C. (unitatea de comanda) asigura selectarea schemei detest- TEST MODE.

DACOM IMPEX S.R.L. V4.0

6

Page 7: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

• Echipamente neimpamantate (UST) trei pozitii (configurarea schemei de legaturirealizata intern)

• Echipamente impamantate (GST)

• Echipamente impamantate utilizand conexiune de gardare (GSTguard) trei pozitii.

CARACTERISTICI IMPORTANTECARACTERISTICI IMPORTANTECARACTERISTICI IMPORTANTECARACTERISTICI IMPORTANTE

Echilibrare automata a puntii comanda de un microprocesor performant.

Testarea si verificarea automata a calibrarii si a operarii.

Afisaj cu cristale lichide (LCD) mare si usor de citit, afisand informatiialfanumerice si grafice.

Butoane MENIU frontale pentru selectarea modului de operare.

Doua borne si doua cabluri de masura (joasa tensiune) simplificand masuratorilein cazul transformatoarelor cu mai multe infasurari si intrerupatoare continandizolatori interiori si exteriori.

Circuit de suprimare automata a interferentelor asigurand functionarea cu inalaacuratete in statii de inalta tensiune, de pana la 765 KV, in conditii de campuriperturbatoare electrostatice si magnetice.Circuitul de eliminare a perturbatiilor poate fi comandat ON sau OFF folosindbutoanele MENIU. Cand circuitul de supresare a interferentelor este activ- ON,prezenta interferentelor este afisat pe display.

Citirea directa a urmatoarelor marimi:� Tensiune� Curent� Curent echiv. la 10KV� Tangenta de delta in % � Factorul de putere in % � Pierderile de putere in W echivalente la 10KV

Tipareste pe o imprimanta externa datele masurate si eventual memorate.

Un PC sau laptop poate fi conectat in locul imprimantei pentru a transfera datele.

Creion optic de citire cod bara pentru identificarea echipamentului si introducereatemperaturii- optional.

Memorie de tip Cheie ce memoreaza 127 seturi de rezultate pentru o analiza

DACOM IMPEX S.R.L. V4.0

7

Page 8: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

ulterioara. Datele masurate pot fi transferate ulterior catre calculator.

Doua intrerupatoare de urgenta ( cu actionare manuala)

Adaptor intren ce permite utilizarea trusei impreuna cu un rezonator extern,permitand extinderea domeniului de masura. Se foloseste la masurareageneratoarelor

Realizata din doua piese constructive usurand transportul.

Corespunde standardelor Europene EMC si Low Voltage Directives.

DACOM IMPEX S.R.L. V4.0

8

Page 9: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Capitolul 2Capitolul 2

AVERTISMENTEAVERTISMENTE

Setul de test automat si echipamentele testate sunt o posibila sursa de inaltatensiune si toate persoanele care realizeaza sau asista la teste trebuie safoloseasca toate normele impuse de protectia muncii in asemenea conditii.Personalul ce executa testele trebuie sa stea la distanta de toate partileechipamentului energizat pentru a preveni contactul cu acestea, sau elementelegate de acesta, pana cand setul de test este deconectat si toate partileechipamentului puse la pamant. Persoanele ce nu sunt implicate direct inaceasta activitate trebuie tinute la distanta de zona de test prin bariere siatentionari. Un circuit de interblocare este prevazut in unitatea de comanda asetului de test pentru a permite operatorului sa blocheze generarea tensiuniide test in cazuri extreme. Circuitul de interblocare trebuie sa fie folosit pentrua deconecta automat alimentarea generatorului de inalta tensiune atunci candpersoane neautorizate patrund in zona, sau pentru oricare alte motive desiguranta.

Tratati toate echipamentele de inalta tensiune ca surse potentiale de risc deelectrocutare. Pot exista intodeauna tensiuni induse la aceste terminale deechipamentele invecinate energizate, sau de linii de inalta tensiune ce trec prinapropiere. Folositi intodeauna o prajina de siguranta impamantata pentru aimpamanta conductoarele de inalta tensiune. O legatura de siguranta deimpamantare trebuie instalata intre terminalele echipamentului testat sipamant. Intodeauna deconectati mai intai legaturile de la echipamentul testatsi apoi de la aparat. Conectarea catre masa a aparatului trebuie intodeaunaprima facuta si ultima desfacuta. Orice deconectare accidentala a legaturii deimpamantare poate genera pericol de electrocutare.Acest instrument este alimentat la o sursa c.a. monofazata. Este prevazut cu unconductor de alimentare cu trei fire si necesita priza suco. Tensiunea dintre Faza siNul nu trebuie sa depaseasca tensiunea maxima de 250 V 50Hz. Firul de impamantare trebuie sa fie la potentialul pamantului.

DACOM IMPEX S.R.L. V4.0

9

Page 10: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

ATENTIE

Alimentarea setului de test se va face numai de la prize cuimpamantare.Orice intrerupere a conexiunii de impamantare poate genera Pericol de electrocutare.

Verificati daca priza este corect legata si impamantata inainte de a conecta aparatul.Setul de test se alimenteza la c.a. 220/240 prin intermediul unui transformator interncare este folosit pentru a reduce tensiunea.Firul de ‘Nul’ al cordonului de alimentare (alb sau albastru) va fi conectat la nululprizei. Firul de impamantare al cordonului (verde sau galben/verde) se va lega la legaturade ‘Pamant' a prizei.Firul cald (negru sau maro) al cordonului se va conecta la ‘Faza’.Aparatul nu trebuie alimentat de la o priza cu doua faze (fire calde). Setul de test este prevazut cu sigurante. Pentru a le inlocui, adresati-va personaluluicalificat. In scopul prevenirii defectarii echipamentului utilizati numai sigurantaspecificata in Cap.3, specificatie ce este in acord cu tipul, tensiunea, curentulsigurantei folosite.AVO International a efectuat toate verificarile legate de asigurarea tuturor normelorde protectie pentru proiectul initial si toate modificarile efectuate ulterior. Aceastaprocedura este obligatorie pentru orice produs Biddle si acopera tot domeniul deasigurari impuse de standarde. Cu privire la acest aspect este imposibil sa seelimine toate accidentele posibile ce pot surveni la echipamentele electrice. Dinacest motiv toate eforturile din acest manual sunt indreptate in scopul evidentieriiprocedurilor corecte si protectiile necesare ce trebuiesc urmate atunci cand selucreza cu acest echipament.Este esential ca utilizatorul odata cu respectarea regulilor urmatoare de protectie dinacest manual, sa ia in considerare toate regulile de protectie impuse de test inaintede a incepe masuratorile.

Asigurarea protectiilor cade in sarcina utilizatorului.Gresita utilizare a aparatului poate fi extrem de periculoasa.Utilizati acest aparat numai in modul in care este indicat in manual. Nu folositiaparatul sau accesoriile sale cu alte dispozitive, altele decat cele descrise inmanual. Niciodata sa nu conectati aparatul la echipamente aflate sub tensiune.Masuratorile sunt interzise pe ploaie sau ninsoare.Nu folositi aparatul in medii explozive.Un operator calificat trebuie sa supravegheze tot timpul lucrul cu acest aparat.Observati toate atentionarile de protectie marcate pe aparat.Intretinerea aparatului este obligatoriu sa fie efectuata de personal calificat ceeste familiarizat cu constuctia, operarea si cu riscurile implicate.

DACOM IMPEX S.R.L. V4.0

10

Page 11: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

IEEE recomanda normele de protectie in teste de I.T.

Daca echipamentul de test este operat corect si toate impamantarile au fost facutecorect, personalul ce efectueaza testele nu are nevoie de manusi de cauciuc. Ca oprocedura de protetie suplimentara, unii utilizatori recomanda purtarea manusilor decauciuc nu numai cand efectueaza legaturile ci si atunci cand manipuleaza unitateade comanda. AVO International considera aceasta masura de protectie excelenta.

Descarcarile de I.T. sau alte surse de camp puternic magnetic sau electric potinterfera (influenta) corecta functionare a stimulatoarelor cardiace. Persoanele custimulatoare cardiace trebuie sa obtina avizul expertilor inainte de a opera sau a seapropia de acest echipament in timpul masuratorilor.

Urmatoarele notificari de AVERTIZARE si ATENTIE sunt folosite in acest manualacolo unde este necesar si trebuie cu strictete luate in considerare.

ATENTIE ( WARNING) ATENTIE, dupa cum este folosit in acest manual este definit ca o

conditie ce poate determina accidentari grave sau chiarMOARTEA.

AVERTIZARE ( CAUTION )AVERTIZARE, dupa cum este folosit in acest mnual, este definit cao conditie sau practica care ar duce la defectarea sau distrugereaaparatului sau a echipamentului testat.

DACOM IMPEX S.R.L. V4.0

11

Page 12: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Capitolul 3Capitolul 3

CARACTERISTICI TEHNICECARACTERISTICI TEHNICE

CARACTERISTICI ELECTRICECARACTERISTICI ELECTRICECARACTERISTICI ELECTRICECARACTERISTICI ELECTRICE

Putere de intrare : Biddle catalog nr. 672001-45 si 672000-47: 240 VA 50/60 Hz, 5A continuu 1 KVA continuuInstalatii conform IEEC 1010-1 categoria II

Dispozitive de protectie: Intrerupator 230V, 15 A contact dubluSigurante, denumire IEC: Tip T, 230V, 3,15A (model MDA, ceramic)

Tensiunea de iesire, Curentul:Domeniul tensiunii de iesire : 0 la 12 KVCurentul maxim continuu : 100 mA la 10 KV, 83mA la 12 KVCurentul maxim intermitent: 200 mA la 10 KV, 167 mA la 12 KV, 15 min,

pauza 15 min, maxim 8 cicluri de test.

Puterea sursei de alimentare poate fi crescuta pana la 4A utilizand ResonatingInductor (Cat. No. 670600)

Frecventa de test: 50 sau 60 Hz ( frecventa retelei de alimentare)Domenii de masurare: Tensiune : 250V la 12 KV, 10 V rezolutie,

tensiunea minima de lucru recomandata 0,5 KVCurent: 0 la 5 A, in 5 domenii, 1µA rezolutie pe domeniul

cel mai mic. Calculeaza si curentul echivalent la 2,5 KV si la

10 KV

Capacitate: 1pF la 1,1 µF, 0.01 pF rezolutie pe domeniul cel mai mic.

Tangenta de delta: 0 la 200 %, 0.01 rezolutie maxima. (DF) Factor de putere: 0 la 90 %, 0.01 rezolutie maxima . (PF)Pierderea in Wat : 0 la 2 KW, 0.1 mW rezolutie maxima.

0 la 100 KW corectata la 10 kV echivalent

Masuratorile pot fi corectate automat la valori echivalente pentru 2,5 kV sau 10 kVSetul de test poate masura valori negative pentru DF, PF, Pierderi in Wati.

DACOM IMPEX S.R.L. V4.0

12

Page 13: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Precizie:Tensiune (rms): ±(1% din citire +1 digit)Curent (rms): ±(1% din citire + digit)Capacitate: ±(0.5% din citire + 2pF) UST

±(0.5% din citire + 6pF) GST Tangenta de delta: ±(2% din citire + 0.05% DE)Factor de putere: ±(2% din citire + 0.05% PF)Pierderi in Wat la 10 KV: ±(2% din citire + 1mW)

Timpul de masurare: 10 la 45 secunde, depinzand de modul de operare

Scheme de masuraSapte scheme masura pentru a face toate testele posbile UST, GST.

UST; Firul Rosu pus la masa , se masoara pe firul Albastru UST; Firul Albastru pus la masa , se masoara pe firul RosuUST; Fara impamantare, se masoara Albastru + RosuGST; Firele Rosu si Albastru sunt puse la masaGST; Rosu si Albastru gardate, fara impamantareGST; Rosu gardat, Albastru pus la masaGST; Albastru gardat, Rosu pus la masa

Modul de operare

Urmatoarele moduri de operare pot fi selectate de pe panoul frontal prin butoanelede MENIU. Schema de test selectata este indicata continuu pe display-ul grafic.

1. Masurarea capacitatii sau a curentului de excitatie.2. Masurarea cu polaritate normala si inversa, masuratori numai polaritate

normala.3. Masurarea cu supresare activa sau nu (ON sau OFF).4. Selectia modurilor tiparire/memorare (PRINT/STORE), numai tiparire

(PRINT ONLY), numai memorare (STORE ONLY), sau niciuna (NONE),referitor la datele obtinute din masuratori.

5. Selectia modului deblocat (UNLOCK), sau blocat (LOCK). Modul de lucrublocat se refera la blocarea modului de operare pe stare selectata inprealabil.

Supresarea interferentelorSupresarea automata a curentilor de interferenta ce apar in teren in statiile detransformare permite operarea fara probleme in statii de pana la 765 kV.Masuratorile pot fi facute cu sau fara supresarea interferentelor. Existentainterferentelor este indicata pe display.

Supresare magnetica: 1000 mT in orice directie

DACOM IMPEX S.R.L. V4.0

13

Page 14: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Capacitatea maxima masurabila la 50/60 Hz

Tensiune test (KV)

Capacitatea max. (µµµµF) 100 mA continuu

Capacitatea max. (µµµµF) 200 mA pt. 1 min

60 Hz 50 Hz 60 Hz 50 Hz 2,5 sau mai mica 0,11 0,11 0,11 0,11

4,0 0,066 0,080 0,11 0,115,0 0,052 0,062 0,11 0,116,0 0,044 0,053 0,088 0,1068,0 0,033 0,040 0,066 0,080

10,0 0,026 0,031 0,052 0,06212,0 0,022 0,026 0,044 0,053

EMC/ Vibratii/ CalitateIntruneste cerintele standardelor europene EMC si Low Voltage Directives si ASTMD999.75

CONDITII DE MEDIUCONDITII DE MEDIUCONDITII DE MEDIUCONDITII DE MEDIU

Temperatura de lucru: -0° la 50° CTemperatura de stocare: -50° la 60° CUmiditate relativa: 0 la 90% fara condensare (operare)

0 la 95% fara condensare (stocare)

AVERTIZARE Pastrarea pentru timp indelungat la temperatura inalta si umiditateridicata pot duce la deteriorarea afisajului LCD.

DACOM IMPEX S.R.L. V4.0

14

Page 15: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

DATE FIZICEDATE FIZICEDATE FIZICEDATE FIZICESetul de test este alcatuit din doua unitati separate: unitatea de comanda si unitateade inalta tensiune.DimensiuniUnitatea de comanda: 381x559x404 mm (HxWxD)Unitatea de inalta tensiune: 381x559x404 mm (HxWxD)Sacosa cabluri: 38x10x43 cm (HxWxD)

GreutateUnitatea de comanda: 33 kg Unitatea de inalta tensiune: 29 kgCabluri (in sacose): 16 kg

Circuitul de masuraPuntea este realizata pe principiul puntilor cu brate inductive reglabile in opozitie.

Condensator de referintaCondensator cu gaz: SF6 100 pF ± 0.5 % 12 KV.Transformator de putere: Transformator dublu ecranat.

Pasivizare-gardare (guarding)Circuit cu garda calda. Circuitul de pasivizare include transformatorul de putere,capacitatea de referinta, intreg circuitul de inalta tensiune si cablurile de iesire detest.

Display: LCD 256 x 128 pixels (W x H)120 x 60 mm zona de lucru

ImprimantaO imprimanta alimentata la baterii este livrata cu echipamentul pentru a tiparirezultatele masuratorilor curente, sau ale masuratorilor memorate in memoria cheie.Imprimanta oferita este termica tip DPU-411 Type II produsa de Seiko InstrumentsInc. Un manual separat este livrat odata cu imprimanta.

Memoria de date tip Cheie ( Data Key )Doua memorii de date tip Cheie sunt livrate fiecare putand memora 127 rezultate deteste. Datele astfel memorate se pot transfera catre un PC prin intermediul uneiinterfete si un program special.

Creionul optic de citire cod baraIdentificarea echipamentului testat poate fi inclusa in rezultatul tiparit prin folosireacreionului de cod bara livrat optional. Creionul optic citeste codul bara de peetichetele cod bara Cod 39 aflate pe echipamentele testate pana la o lungime de 39caractere. O foaie cu caractere tip este livrata si are toate caracterele necesarepentru a stabili un nr. de identificare (ID Nr.), astfel incat utilizatorul poate sa-sicreeze singur o eticheta. Introducerea caracterelor de identificare se poate facecaracter cu caracter sau prin citirea intregului sir de coduri bara.

DACOM IMPEX S.R.L. V4.0

15

Page 16: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Borne si conectoare:

Inalta tensiuneJoasa tensiune (2) marcate rosu (Red) si albastru (Blue)Interconectare (2)Retur de la Inductor RezonantAlimentareBlocare externa (2)ImpamantareImprimanta (interfata RS 232C)Cititor cod baraData key

Protectii

Tensiune de iesire la pornire zero.Doua intrerupatoare externe de interblocare (incluse) ce trebuie sa fieinchise pentru a energiza circuitul de I.T. Dubla impamantare necesara pentru a porni circuitul de I.T. Intrerupator automat la scurtcircuit pe iesire.Toate comenzile sunt la potentialul pamantuluiProtectii la supratensiune in eventualitatea defectarii echipamentuluiIntrarile de joasa tensiune de masura sunt impamanatate cand setul detest este inchis sau intre masuratori.

DACOM IMPEX S.R.L. V4.0

16

Page 17: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

ACCESORII FURNIZATEACCESORII FURNIZATEACCESORII FURNIZATEACCESORII FURNIZATE

1. Cablu de alimentare 2,5m 1buc2. Cablu impamantare 4,6m 1buc3. Cablu I.T. dublu ecranat, cu terminal de tip carlig sau cleste 21,4m 1buc4. Cablu masura joasa tensiune 21,4m , ecranate tilate Rosu si Albastru 2 buc5. Cablu interconectare 1,5m 2 buc6. Dispozitiv interblocare cu cablu 2,5m 1buc7. Dispozitiv interblocare cu cablu 21,4m 1buc8. Huse protectie pentru conectorii HV 2 buc9. Sacosa pentru cabluri 1buc10.Imprimanta portabila termica cu interfata seriala 1buc11.Cablu de conexiune imprimanta la Delta 2000 1buc12.Cablu de conectare a Casetei Data Key la calculator 1buc13.Chei memorare 2 buc14.Caseta Data Key si soft de transfer 1buc15.Cablu alimentare caseta Data Key 1 buc16.Cutii de transport captusite cu burete 2 buc17.Manual utilizare 1buc

ACCESORII OPTIONALEACCESORII OPTIONALEACCESORII OPTIONALEACCESORII OPTIONALE

• Creion cititor optic • Conectoare prize tangenta de delta izolatori (2) cod 670506• Calibrator standard pentru capacitate si tan delta cod 670500-1 • Benzi conductoare “inel cald “ (3) cod 670505 • Celula tangenta de delta ulei 10kV cod 670511• Inductor Rezonant cod 670600• RS232 cablu cod 34675• Intrerupator de siguranta actionat la picior cod 10229-2 • Caseta cabluri cod 218744-1• Caseta transport pentru calibrator cod 670635• Conductor de Inalta Tensiune 7,6 m cod 30012-8

DACOM IMPEX S.R.L. V4.0

17

Page 18: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Figura 1: Panoul unitatii cetrale

DACOM IMPEX S.R.L. V4.0

18

Page 19: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Capitolul 4Capitolul 4

COMENZI, INDICATORI, CONECTORICOMENZI, INDICATORI, CONECTORI

PANOUL UNITATII DE COMANDA (FIG.1)PANOUL UNITATII DE COMANDA (FIG.1)PANOUL UNITATII DE COMANDA (FIG.1)PANOUL UNITATII DE COMANDA (FIG.1)

1. GROUND Terminalul de impamantare - acest surub cu fluture permiteconectarea setului de test la pamant.

2. OPEN GROUND Indicator ce arata ca setul de test nu este impamantat sau circuituldublu de impamantare este deschis.

3. MENU Trei taste cu membrana pentru a selecta meniurile, deplaseazacursorul in sus si in jos, selecteaza conditiile de test (setup),comanda trimiterea rezultatelor testului catre imprimanta sau catreData Key, introducerea ID NO. si a temperaturii de la creionul optic.

4. LCD Display cu cristale lichide afisand informatii despre Menu Setup, testesi procedura de calibrare. Afiseaza rezultatele testelor si indicaconditiile de testare, indicand si prezenta tensiunii inalte laterminalele de inalta tensiune.

ATENTIE Tensiunea inalta este prezenta la terminalele de inalta tensiune ori decate ori doua simboluri de inalta tensiune sunt afisate pe display.

5. CONTRAST Potentiometru pentru modificarea contrastului si unghiului de refexie al display-ului LCD.

6. DATA KEY Memorie tip cheie, ofera posibilitatea de a memora rezultatele unorteste anterioare sau curente in cazul in care se introduce o memorieData Key. O astfel de memorie poate memora 127 de teste. Doua

Data Key sunt livrate. Rezultatele memorate in Data Key se pot transfera catre un PC prin intermediul unei interfete seriala RS 232C.

DACOM IMPEX S.R.L. V4.0

19

Page 20: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

7. Test MODE Sapte taste cu membrana selecteaza modurile UST,GST. Barele colorate aflate alaturi de butoane ajuta la identificarea conexiunilor catre echipamentul testat, corespunzator schemei, respectiv active,pasivizate (gardate) sau impamantate.

UST Echipamente de testat neimpamantate; se masoara intre terminaleleinalta si blue(albastru)-red(rosu) pus la masa.

UST Echipamente de testat neimpamantate; se masoara intre terminaleleinalta si red(rosu)- blue(albastru) pus la masa

UST Echipamente de testat neimpamantate; se masoara intre terminaleleinalta si ambele terminale red si blue

GST Echipamente de testat impamantate; terminalele red si blue puse lamasa

GST Echipamente de testat impamantate; terminalele red si blue sunt pasivizate (gardate), nu sunt puse la masa

GST Echipamente de testat impamantate; terminalul red este gardat, iar terminalul blue este pus la masa.

GST Echipamente de testat impamantate; terminalul blue este gardat, iar terminalul red este pus la masa.

8. POWER Indicator alb ce arata ca intrerupatorul principal este ON si aparatuleste alimentat.

9. ON/OFF Intrerupator principal magnetic bipolar ce asigura alimentarea sistemului de test precum si protectia la scurtcircuit sau suprasarcina.

10.HIGH VOLTAGE Este o lampa rosie ce indica atunci cand este aprinsa, ca iesirea generatorului de inalta tensiune este activa.

11.HIGH VOLTAGE ON Buton alb cu revenire ce determina activarea circuitului de generare atensiunii inalte si aprinderea lampii HIGH VOLTAGE in conditiile in care potentiometrul OUTPUT HIGH VOLTAGE este setat in pozitiaZERO START si intrerupatorul de blocare este apasat.

12.HIGH VOLTAGE OFFButon rosu, cu revenire prin apasare, opreste imediat generarea tensiunii inalte. Poate fi folosit ca o oprire de urgenta determinand stingerea becurilor TESTING si HIGH VOLTAGE si stergerea display-ului.

13.OUTPUT VOLTAGE CONTROLAuto transformator variabil utilizat pentru a regla tensiunea inalta deiesire (HV), prin modificarea tensiunii primare a transformatorului deinalta tensiune. Porneste de la ZERO START pentru a activa iesireade inalta tensiune.

DACOM IMPEX S.R.L. V4.0

20

Page 21: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

14.OPERATIONTrei butoane cu membrana utilizate dupa cum urmeaza:NEW TEST- Dupa terminarea masurarii (testului) operatorul poate alege inceperea unui nou test apasand acest buton; va determina aparitia ecranului de test in care operatorul poate alege diverse configuratii de test si repornirea tensiunii de test. Sterge de pe displayrezultatele anterioare.

MEASURE - Atunci cand este apasat determina inceperea unui ciclude test. La terminare, tensiunea de test este oprita si rezultatele suntafisate pe display. Becul rosu lumineaza cand se efectueaza masuratorile si tensiunea inalta este aplicata echipamentului testat.

ATENTIE Tensiunea inalta poate fi aplicata echipamentului testat chiar atuncicand becul este stins. Acordati atentie celor doua semne de inaltatensiune ce apar pe display pentru confirmare.

RECALL VOLTAGE - acest buton este activ numai dupa terminareamasuratorii, iar rezultatul este deja afisat pe LCD si butonul NEW TEST este apasat. In aceste conditii, prin apasare inalta tensiune va fireaplicata echipamentului testat fara o trecere prin zero a circuitului deinalta tensiune. Aceasta facilitate permite operatorului economie detimp atunci cand repeta testele sau doreste sa efectueze masuratori inalte configuratii ale schemei de test prin utilizarea comenzilor LOWVOLTAGE LEAD CONFIGURATION

Generator de sunet intern (nu se vede in figura) Suna la apasarea unui buton cu membrana.

DACOM IMPEX S.R.L. V4.0

21

Page 22: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

CONECTORII UNITATII DE COMANDA ( FIG.2,3,4)CONECTORII UNITATII DE COMANDA ( FIG.2,3,4)CONECTORII UNITATII DE COMANDA ( FIG.2,3,4)CONECTORII UNITATII DE COMANDA ( FIG.2,3,4)

15,16. SAFETY INTERLOK 1 si 2Doua conectoare pentru intrerupatoare de Blocare. Douaintrerupatoare manuale sunt oferite. Intrerupatoarele manuale suntutilizate pentru blocarea generatorului de inalta tensiune. In cazul incare se doreste, unul dintre intrerupatoarele de blocare poate fi inlocuitcu un intrerupator de siguranta de zona, in acest caz se va tine seamade faptul ca intrerupatorul va fi inchis atunci cand poarta sau zona esteinchisa si va fi legat la pinii A si B ai conectorului. Cablul de legatura alintrerupatorului de blocare va fi realizat dintr-un cablu dublu rasucit,astfel incat sa se evite campurile parazite. Cand intrerupatorul sedeschide testul este automat suspendat.

ATENTIE Cand intrerupatorul de blocare extern este deschis si butonul HV ONeste apasat circuitul de blocare este alimentat cu 12O V. Ca atare atentiela izolatia circuitului.

17. AC POWERConectorul de alimentatre - alimentare la o priza de c.a. 220 V

18. INDUCTOR RETURNConector pentru conectarea setului de test la un rezonator inductivResonating Inductor (Cat. No. 670600) pentru a extinde domeniulde masura capacitiv.

19,20. INTERCONNECT 1 si 2Conectorii de INTERCONECTARE intre Unitatea de Comanda siGeneratorul de inalta tensiune.

Figura 2: Conectorii unitatii de comanda (dreapta)

21. LOW VOLTAGE RED

DACOM IMPEX S.R.L. V4.0

22

Page 23: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Conector pentru a conecta firul de masura de joasa tensiune red(rosu).

22. LOW VOLTAGE BLUEConector pentru a conecta firul de masura de joasa tensiune blue(albastru).

23. PRINTER/ RS-232 Port Conector pentru imprimanta sau port RS-232 pentru PC.

Figura 3: Conectorii unitatii de comanda (stanga)

24. BAR CODE WAND Permite aparatului intoducerea nr. de identificare al echipamentului

testat si a temperatura in rezultatul testului cand un creion de citirecod bara este conectat.

Figura 4: Conectorii unitatii de comanda (frontal)

DACOM IMPEX S.R.L. V4.0

23

Page 24: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

CONECTORII UNITATII DE INALTA TENSIUNE (FIG 5)CONECTORII UNITATII DE INALTA TENSIUNE (FIG 5)CONECTORII UNITATII DE INALTA TENSIUNE (FIG 5)CONECTORII UNITATII DE INALTA TENSIUNE (FIG 5)

25,26. INTERCONNECT 1 si 2Conectorii de INTERCONECTARE intre Unitatea de Comanda si Generatorul de inalta tensiune.

27. HV OUTPUT Conectorul pentru cablul de inalta tensiune.

28. GROUND Surub pentru conectarea la masa a ecranului exterior al cablului de inalta tensiune.

Figura 5: Conectorii unitatii de inalta tensiune

DACOM IMPEX S.R.L. V4.0

24

Page 25: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Capitolul 5Capitolul 5

SETARE SI OPERARESETARE SI OPERARE

INSTRUCTIUNI DE PROTECTIEINSTRUCTIUNI DE PROTECTIEINSTRUCTIUNI DE PROTECTIEINSTRUCTIUNI DE PROTECTIE

Iesirea generatorului trusei poate fi mortala. Ca la orice echipament de inalta tensiuneanumite precautii trebuiesc folosite intodeauna si toate regulile de protectia munciirespectate. Cititi si intelegeti Capitolul 2 ‘AVERTISMENTE’ inainte de a lucra cu acestechipament.Asigurati-va ca echipamentul ce urmeaza a fi testat este deconectat si impamantat inaintede a face conexiunile, curatati echipamentul de putere ce va fi testat si faceti legaturile deimpamantare la barele flotante in acord cu normele societatii dvs, urmarind cu atentie toateprocedurile de protectie.Asigurati-va ca nimeni nu este in contact cu iesirea de inalta tensiune a aparatului sauorice terminal al echipamentului energizat de acesta. Folositi bariere de protectie. Asezaticele doua unitati ale setului de test intr-o zona cat mai uscata posibila.

Mentineti la distanta adecvata conductoarele energizate de pamant pentru a prevenidescarcarile. Astfel de descarcari accidentale ar putea distruge echipamentul supustestului. O distanta minima de 30 cm este recomandata.

DACOM IMPEX S.R.L. V4.0

25

Page 26: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

PIF ( SETUP)PIF ( SETUP)PIF ( SETUP)PIF ( SETUP)Urmatoarele etape sunt un ghid general pentru PIF-ul setului de test. Figura 6 aratalegaturile tipice pentru a testa un transformator trifazat triunghi stea de putere.Figura 7 arata conexiunile tipice pentru a masura curentul de excitatie pentru unacelasi tip de transformator. Comenzile aparatului au fost identificate in figurile 1pana la 5. Pentru alte tipuri de aplicatii cititi Sectiunea 2. APLICATII SI EXEMPLEpentru instructiuni si legaturi specifice.

ATENTIE

Exista intodeauna pericolul inducerii tensiunii la bornele echipamentuluitestat din cauza posibilei apropieri de linii sau echipamente de inaltatensiune. O tensiune statica reziduala poate fi de asemenea prezenta laaceste terminale. Impamantati fiecare terminal ce va fi testat cu o prajinade siguranta de impamantare, apoi instalati legaturile de impamantare sinumai dupa aceea realizati legaturile catre aparat.

1. Asezati setul de test la cel putin 1,8m distanta de echipamentul testat.

2. Conectati la o priza sigura de pamant surubul (1) cu piulita fluture al unitatii de comandaprin intermediul cablului lung de 4,5m furnizat in acest scop. Aceasta conexiune va fiintodeauna prima facuta.

3. Conectati Unitatea de Comanda (conectorii 19,20) la Unitatea de inalta tensiune(conectorii 25,26) folosind cele doua cabluri de interconectare furnizate, lungi de 1,5 m.

4. Conectati cablul de masura de joasa tensiune colorat RED in conectorul (21) LV RED.Daca este nevoie conectati si cablul BLUE in conectorul LV BLUE (22). Asigutrati-va casunt corect montate.

5. Conectati cablurile de interblocare sau sistemul de blocare zonal in conectoarele (15,16)SAFETY INTELOCK, asigurindu-va de corecta montare a acestora.

6. Conectati imprimanta in conectorul PRINTER/RS-232 (23) al setului de test daca doriti.Pozitia dip-switch-urilor de pe spatele imprimantei trebuie sa fie ca mai jos.

Figura 8: Setarea Dip Switch-urilor imprimantei

7. Conectati creionul optic pentru citire cod bara daca este cazul in conectorul (24).

DACOM IMPEX S.R.L. V4.0

26

Page 27: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

8. Conectati cablul de inalta tensiune HV (27). Prindeti papucul ecranului cablului de inaltatensiune la surubul galben-pamant (28) si apoi insurubati astfel incat ecranul sa facacontact ferm.

NOTAInelul exterior de la capatul cablului dinspre echipamentul de test estela potentialul ecranului. Inelul interior este la potentialul mesei. Ambeleinele au o margine de care se pot prinde clesti aligatori pentru a faceconexiuni, daca este nevoie, la masa sau la ecran. Mentineti curatfiecare capat al cablului asa incat sa nu existe praf sau umezeala intimpul instalarii si operarii. Curatati cu o carpa curata sau umezita inalcool.

9 Cu intrerupatorul principal OFF introduceti cablul de alimentare in priza de alimentare

(17) de pe panoul frontal precum si in priza suco a sursei de tensiune.

10Prindeti crocodilul cablului de masura ( red sau blue ) de terminalul corespunzator alechipamentului de test.

11 Legati carligul (sau clestele) terminalului cablului de inalta tensiune la terminalul dorit.

Atunci cand masurati capacitatea unui transformator scurtcircuitati intodeauna fiecareinfasurare pentru a elimina efectul nedorit al inductantei infasurarii. Pentru curent deexcitatie realizati testul numai pentru infasurarea de inalta tensiune. Aceasta va reducecurentul de incarcare necesar. La schimbatoarele de ploturi comutati in pozitii extremepentru test de rutina.

ATENTIE Cablul de inalata tensiune nu trebuie sa atinga partile metalice aflate subtensiune ale echipamentului testat. In caz contrar acesta se poatestarpunge.

Cablul de inalta tensiune are la exterior o izolatie cauciucata de culoare neagra sub careeste un ecran ce este pus la pamant. Structura izolatiei este astfel realizata astfel incat sarezizte la starapungeri dinspre interior ( firul cald 12kV) catre exterior. Daca suprafataexterioara a cablului atinge partea metalica a bornelor echipamentului ce este testat, inmomentul aplicarii tensiunii de test, poate aparea o starpungere dinspre exterior catreconductorul de ecran impamantat al cablului.

DACOM IMPEX S.R.L. V4.0

27

Page 28: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Figura 6: Conexiunile tipice ale setului de test pentru un transformator trifazat triunghi-stea

DACOM IMPEX S.R.L. V4.0

28

Page 29: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Figura 7: Conexiunile tipice pentru masurarea curentului de excitatie.

DACOM IMPEX S.R.L. V4.0

29

Page 30: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

DESCRIEREA ECRANELOR MENIU SI A CELOR DEDESCRIEREA ECRANELOR MENIU SI A CELOR DEDESCRIEREA ECRANELOR MENIU SI A CELOR DEDESCRIEREA ECRANELOR MENIU SI A CELOR DETESTTESTTESTTEST

Operarea setului de test se face prin utilizarea informatiilor afisate pe LCD si comenzi datede la butoanele Unitatii de c-da. La punere sub tensiune se va auzi un ‘beep’ iar setul detest va executa un test complet de RAM si va initializa software-ul si hardware-ul.

ECRANUL DE PORNIRE (Fig. 9) La pornire pe LCD se va prezenta ecranul de pornire (fig 9) Acest ecran va fi urmat de un‘Beep” si aparatul va testa hardware-ul. Daca nu apar erori mesajul ‘IN PROGRESS’ afisatin partea de jos a ecranului va fi inlocuit cu mesajul ‘SUCCESFUL’ .

AVO INTERNATIONALBIDDLE

DELTA-2000SELF-DIAGNOSTIC

ANDCALIBRATION CHECK

IN PROGRESS

Figura 9: Ecranul de pornire

ECRANUL REZULTATELEOR DE AUTOTESTARE (Fig. 10)Daca apar erori va fi afisat ecranul rezultatelor autotestelor si va fi afisata lista defectelordetectate. Pentru lamuriri examinati sectiunea Maintenance and Calbration.

SELF-DIAGNOSTIC RESULTS:

.....................................

.....................................

.....................................

PLEASE REFER TO THE INSTRUCTION MANUAL FOR HELP.

Figura 10: Ecranul rezultatelor autotestului.

DACOM IMPEX S.R.L. V4.0

30

Page 31: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

PRIMUL ECRAN DE TEST (Fig . 11)

Primul ecran de test apare dupa trecerea cu succes a testelor de initializare.

Figura 11: Primul ecran de test

TEST-- Mesaj care arata numarul testului efectuat.

GST-- GUARD BLUE, GND RED - Mesaj ce indica configuratia legaturilor de joasa tensiune.

SELECT LEAD CONFIGURATION Mesaj ce ofera operatorului posibilitatea alegeriiconfiguratiei adecvate a legaturilor de joasa tensiune, selectare ce se poate efectua prinintermediul tastelor cu membrana de pe panoul frontal.

ENERGIZE HIGH VOLTAGE Acest mesaj indica operatorului sa energizeze circuitul deinalta tensiune (via butonul de pe panoul frontal) inaintea inceperii testului.

V: kV Tensiunea aplicata echipamentului testat este afisata pe aceasta linie atunci candcircuitul de inalta tensiune este activat.

IT: mA Curentul total este afisat pe acesta linie atunci cand circuitul de inalta tensiuneeste activat. PLEASE INSERT DATA KEY Mesaj ce indica operatorului conectarea Data key atuncicand memorarea rezultatelor este selectata.

Blocurile de stare afisate in partea dreapta a ecranului ofera indicatii continue asuprafunctiilor selectate. Aceasta facilitate ofera utilizatorului posibilitatea de a face masurarirepetate fara a mai trece prin meniu. Blocurile de stare sunt definite mai jos.

DACOM IMPEX S.R.L. V4.0

31

Page 32: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 2: Definirea blocurilor de stare pe Ecranul de Test

Status Block Definition

A.c. insulation test- Test de tan delta

Transformer excitation test- Test de curent de excitatie

Interference suppressor: turned on -Supresarea interferantelor: Comutat ON

Interference suppressor: turned off -Supresarea interferentelor: Comutata OFF

Voltage polarity: normal/reverse - Polaritate tensiune :normala si defazata 180 grd

Voltage polarity: normal only - Polaritate tensiune : numainormal

Print and store readings: print and store- Tiparirea simemorarea rezultatelor: tiparire si memorare

Print and store readings: print readings - Tiparirea simemorarea rezultatelor: tiparire

Print and store readings: store readings - Tiparirea simemorarea rezultatelor: memorare

Print and store readings: none - Tiparirea si memorarearezultatelor: nimic

Pe ultimul rand al ecranului este afisata linia de comanda, adica functiile butoanelor aflateimediat sub display. Pe ecranul initial cu optiunea PRINT/STORE selectata aceste functiisunt MENU, WAND si HEADER.

MENU Afiseaza primele doua ecrane meniu, permitand operatorului modificareaparametrilor. Prin apasarea acestui buton se va intra in primul ecran meniu (fig. 12).

WAND Prin apasarea acestui buton cu membrana aflat in drepul inscrisului de pe ecranWAND apar trei optiuni pe linia de comanda: ID NO., CANCEL si TEMP. Prin apasareabutonului de sub ID NO. operatorul poate introduce numarul de identificare al echipamentuluitestat via creionul de citire cod bara. Prin apasarea butonului de sub CANCEL operatorulpoate anula introducerea daca a aparut o greseala. Prin apasarea butonului de sub TEMPoperatorul poate introduce temperatura in °C prin creionul de citire cod bara.

HEADER determina tiparirea unui antet de catre imprimanta.

DACOM IMPEX S.R.L. V4.0

32

Page 33: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

PRIMUL ECRAN MENU (Fig. 12)Primul ecran MENU este aratat in fig. 12. si din acest ecran operatorul poateselecta parametri doriti. Randul (optiunea) selectata este aratata in mod videoinvers, iar linia de comanda ofera optiunile disponibile.Butoanele cu membrana situate in centru si dreapta sub ecran sunt afisate pe randul decomanda: UP (sus), DOWN (jos), permitand operatorului sa mute cursorul pe randul dorit.Secventa de mutare a cursorului permite saltul de pe ultimul rand pe primul si invers. Catdespre butonul din stanga acesta este afisat fie CHANGE fie ENTER.

EXIT TO TEST 11/26/9610:27

MEASUREMENT: AC INSULATION TEST (or)XFMR EXCITATION TEST

CORRECTION: NONE (or) 10 kV (or) 2.5 kV

LOSS DISPLAY: POWER FACTOR (or) DISSIPATION FACTOR

INTERFERENCE SUPPRESSOR: ON (or) OFF

HV POLARITY: NORMAL/REVERSE (or) NORMAL ONLY

NEXT MENU

ENTER (OR) CHANGE UP DOWNFigura 12 : Primul ecran MENU

EXIT TO TEST -- determina reintoarcerea la meniul de TEST (fig. 11)

MEASUREMENT -- linie ce selecteza intre masurarea AC INSULATION TEST si testulXFMR EXCITATION TEST.

CORRECTION linie ce selecteza intre NONE, 10 kV, si 2.5 kV. Permite operatorului savada rezultatele curente calculate echivalent pentru tensiunile de test 10 kV sau 2.5 kV(calculate).

LOSS DISPLAY linie ce selecteza intre POWER FACTOR si DISSIPATION FACTOR.Permite selectarea dintre cele doua domenii. Examinati Sectiunea Aplicatii si Exemple pentrua vedea diferentele dintre cele doua marimi

INTERFERENCE SUPPRESSOR linie ce selecteza intre ON si OFF. Alegeti optiunea ONpentru testele efectuate in zone cu interferente, ca statii electrice. Alegeti optiunea OFFpentru teste in zone unde interferentele sunt reduse sau lipsesc, ca ateliere sau laboratoare.Examinati Sectiunrea de Aplicatii pentru a vedea efectele interferentelor.

HV POLARITY linie ce selecteza intre NORMAL/REVERSE si NORMAL ONLY. SelectatiNORMAL/REVERSE pentru a anula efectele interferentelor electrostatice. SelectatiNORMAL ONLY atunci cand interferentele nu sunt prezente.

NEXT MENU la selectare se va afisa al doilea ecran meniu. (Fig. 13).

DACOM IMPEX S.R.L. V4.0

33

Page 34: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

AL DOILEA ECRAN MENIU (Fig. 13)

PRINT/STORE READINGS: PRINT & STORE11/26/96 10:11

(or) PRINT (or) STORE (or) NONE

OPERATION MODE: SINGLE (or) CONTINUOUS

RECALL READINGS

SET CLOCK

FULL CALIBRATION: LAST CHECKED 11/18/96

SAVE SETTINGS

PREVIOUS MENU

ENTER (or) CHANGE UP DOWNFigura 13: Al doilea ecran meniu

PRINT/STORE READINGS - selecteaza una din cele 4 posibilitati disponibile: Tiparire siMemorare, numai Tiparire, numai Memorare, nici una nici alta.

OPERATION MODE - Selectaza functionarea in mod SINGLE sau CONTINUOUS.Selectati SINGLE pentru afisarea rezultatelor dupa un singur test. La selectarea functieiCONTINUOUS setul de test va efectua masuratori in mod continuu (pana la oprireaacestora fie prin eliberarea comutatorului de la INTERLOCK fie prin apasarea butonului curevenire HV OFF) si afisarea rezultatelor acestor masuratori.

RECALL READINGS - determina afisarea urmatorului submeniu,vezi fig 14

SET CLOCK - permite operatorului sa corecteze data si timpul.Atunci cand este selectata aceasta optiune, operatorul este intrebat daca doresteintroducerea lor prin intermediul creionului optic de cod bara. Un raspuns afirmativ, YESpermite operatorului introducerea datei si a orei de la creion, caracter cu caracter. Toatecaracterele se vor introduce, incluzand spatii, zerouri, etc. Cursorul va clipi sub spatiulunde se va inscrie caracterul. Numai numerele se introduc, cursorul sarind automatcelelalte caractere i.e. /,spatiu, :.Un raspuns negativ (NO) inseamna ca datele se vor introduce de la butoanele situate subLCD. Linia de comanda afiseaza de la stanga la drepta OK, RAISE, LOWER,corespunzatoare membranelor situate sub LCD. Cele doua caractere ale lunii sunt afisatein video invers. Utilizati butoanele cu membrna RAISE si LOWER pentru a introduce lunacorecta. Numerele se vor succeda de la 0 la 12 si viceversa. Atunci cand luna este corectaapasati butonul OK. Afisajul va arata atunci in video invers ziua curenta. Se va proceda incontinuare la fel ca la introducerea lunii pentru introducerea tuturor valorilor. Dupaapasarea butonului OK de la minute display-ul se va intoarce la ecranul meniu. Data sitimpul se va actualiza automat dupa aceasta operatie.FULL CALBRATION -- Afiseaza data ultimei calibrari. Este folosit si pentru a

DACOM IMPEX S.R.L. V4.0

34

Page 35: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

incepe un test de calibrare. Acest lucru presupune scoaterea unitatii din carcasaei.

SAVE SETTINGS -- Memoreaza setarea parametrilor.

PREVIOUS MENU -- Permite reintoarcerea in primul meniu (Fig. 12).

SUBMENIUL DE RECHEMARE A CITIRILOR (Fig. 14)

Daca Data Key este folosita optiunea RECALL READINGS poate fi selectata din al doileaecran meniu.

DISPLAY READINGS

PRINT READINGS

CLEAR ALL READINGS

CLEAR LAST READING

RETURN TO MENU

Figura 14: Submeniul rechemarii citirii

DISLAY READINGS si PRINT READINGS -- operatorul este rugat sa introduca numarultestului de start si numarul de teste ce vor fi tiparite si/sau afisate. Butonul din centru RAISE (crestere) si cel din stanga LOWER (descresterea ) determinacresterea sau descresterea valorii afisate. Butonul din stanga confirma valoarea (OK).

Daca DISPLAY READINGS si/sau PRINT READINGS sunt selectate pe display se vorafisa rezultatele testului si/sau se vor tipari, iar pe linia de comanda se vor afisa comenzileNEXT sau EXIT deasupra butoanelor din stanga si respectiv din dreapta. Apasati butonuldin stanga display-ului pentru a vizualiza urmatorul test respectiv butonul din dreaptapentru a iesi din acest submeniu.

CLEAR ALL READINGS (stergerea tuturor inreg.) si CLEAR LAST READINGS (stergeultima inregistrare)-- deteremina aparitia pe ecran a mesajului :

ARE YOU SURE (esti sigur ? ).

Pentru YES apasati butonul din dreapta.Pentru NO apasati butonul din stanga.

RETURN TO MENU - revenirea la al doilea ecran meniu. (Fig. 13)

DACOM IMPEX S.R.L. V4.0

35

Page 36: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

AL DOILEA ECRAN DE TEST (Fig. 15)

Dupa alegerea tuturor parametrilor de test doriti, din primul si al doilea ecran meniu,operatorul va putea selecta EXIT TO TEST din primul ecran meniu (Fig. 12). Prin selectarese va intra in primul ecran de test (Fig. 11).

Daca optiunea STORE este selectata mesajul HEADER nu este afisat. Daca NONE esteselectat numai mesajul MENU este afisat. Functia HEADER determina imprimarea unuiantet (header). Daca functia PRINT/STORE sau STORE este selectata setul de testverifica daca memoria Data Key este introdusa in locasul ei, si daca nu, cere operatoruluiPLEASE INSERT DATA KEY. Pentru a memora datele, Data Key trebuie introdusa in soclusi rasucita catre dreapta un sfert de tura. Din nou functia HEADER va determina trimitereacatre imprimanta a unui antet. Functia WAND determina aparitia unei noi linii de comanda,ID. NO. , CANCEL si TEMP deasupra butoanelor. Functia cere operatorului introducereanumarului de identificare al echipamentului si temperatura prin intermediul creionului optic.Prin apasarea butonului de sub comanda CANCEL se anuleaza valorile curente introduseprin creionul de citire cod bara. Se foloseste atunci cand la introducere se greseste.

Din primul ecran de test (Fig. 11) operatorul poate alege configuratia de test dorita prinapasarea butonului ce specifica LOW VOLTAGE LEAD CONFIGURATION (legaturilepentru cablurile de joasa tensiune) dorita (conform schemei de masura). Acum operatorulpoate activa circuitul de inalta tensiune prin apasarea butonului alb HIGH VOLTAGE ON inconditia cand VOLTAGE CONTROL este pozitionat pe ZERO START.

ATENTIE Tensiunea inalta este de acum prezenta la terminalele echipamentuluitestat.

Dupa activarea circuitului de inalta tensiune pe ecran va apare un al doilea ecran de test(Fig. 15) Numarul testului (daca Data Key este introdusa) si configuratia legaturilor suntafisate pe prima linie. Doua simboluri de inalta tensiune vor aparea indicand prezentainaltei tensiuni.

DACOM IMPEX S.R.L. V4.0

36

Page 37: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Fgura 15: Al doilea ecran de test

AL TREILEA ECRAN DE TEST (Fig. 16)

Operatorul poate acum regla tensiunea de test dorita utilizand HIGH VOLTAGECONTROL. Tensiunea de test si curentul total sunt afisate. Pentru a incepe efectivmasurarea apasati butonul cu membrana MESURE.Se va afisa un al treilea ecran de test (Fig. 16) si mesajul “ MEASUREMENT INPROGRESS “ va fi afisat. Pe liniile de afisare tensiunea de test si curentul se vor mentineafisate ultimele lor valoari.

Figura 16: Al treilea ecran de test

DACOM IMPEX S.R.L. V4.0

37

Page 38: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

ECRANUL REZULTATELOR (Fig. 17)

La terminarea efectuarii masuratorii tensiunea inalta de pe echipamentul de test estedezactivata si rezultatele sunt afisate asa cum se vede in figura 17, incluzand tensiunea detest, pierderile in Watt calculate, factorul de putere si capaciatea. Pentru a vedea valorileechivalente la 10KV sau 2,5KV apasati butonul CORRECTION.

Lampa rosie HIGH VOLTAGE va ramane aprinsa, indicand ca circuitul de inalta tensiuneeste activ. Cele doua simboluri de inalta tensiune de pe ecran dispar indicand faptul cainalta tensiune nu este prezenta la bornele echipamentului testat.

Becul rosu TESTING de langa butonul MEASURE se va stinge aratand ca masuratoareaeste terminata.

Operatorul poate trimite un antet de inregistrare catre imprimanta prin apasarea butonuluicu membrana de sub comnada HEADER de pe display.

Figura 17: Ecranul tipic al rezultatelor

Daca optiunea PRINT AND STORE este selectata rezultatele pot fi memorate in Data Keysi tiparite la imprimanta prin apasarea butonulul de sub inscriptia RECORD.

Daca sistemul de suprimare interferente este activ nivelul relativ de interferenta este indicat(low, medium, sau severe)

DACOM IMPEX S.R.L. V4.0

38

Page 39: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

ECRAN NOU DE TEST (Fig. 18 )

Pentru a continua masuratorile selectati mesajul “PRES NEW TEST TO CONTINUE” aratatin figura 17. Daca ambele sau numai unul dintre inrerupatoarele INTERLOCK au fosteliberate prin apasarea butonului NEW TEST se va intra in primul ecran de test (Fig. 11).Daca au fost mentinute inchise va fi afisat ecranul urmator (Fig. 18)Operatorul poate selecta acum o noua configuratie a legaturilor prin selectarea comenziiLOW VOLTAGE LEAD CONFIGURATION. Noua configuratie de legaturi este afisata peprimul rand al display-ului.

Apasand butonul RECALL VOLTAGE se va intra in al doilea ecran de test (Fig. 15).Tensiunea de test va fi aceeasi ca la testul anterior. Daca se doreste operatorul poatemodifica tensiunea de test.

ATENTIE Tensiunea inalta este de acum prezenta la terminalele echipamentuluitestat.

Urmatorul test poate fi acum efectuat prin apasarea butonului MEASURE.

Figura 18: Ecranul “ TEST NOU”

DACOM IMPEX S.R.L. V4.0

39

Page 40: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

ECRANELE DE TEST LA CONECTAREA UNUI INDUCTOR REZONANT

Daca un inductor rezonant este folosit (Cat. No. 670600) primul ecran de test va fi afisat cain figura 19. Al doilea ecran de test, dupa energizare cu inalta tensiune este indicat in figura20.

Figura 19: Primul ecran de test daca un inductor rezonant este conectat

Figura 20: Al doilea ecran de test daca un inductor rezonant este conectat

DACOM IMPEX S.R.L. V4.0

40

Page 41: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

MASURATORI (CAPACITATE SI TAN DELTA)MASURATORI (CAPACITATE SI TAN DELTA)MASURATORI (CAPACITATE SI TAN DELTA)MASURATORI (CAPACITATE SI TAN DELTA)

Efectuati masuratori numai dupa ce ati citit si inteles Cap. 2. Protectii, setarea parametrilorde test din capitolul anterior precum si Cap. 4 Comenzi, Indicatori, Conectori.Un operator familiarizat cu continutul acestui manual, setul de test si operarea setului detest poate urma procedura condensata prezentata pe partea interioara a capacului setuluide test. Afisajul LCD precum si butoanele de test de pe panoul frontal sunt mijloacele princare operatorul va conduce testele. Amanunte in cap. 4 Comenzi, Indicatori, Conectori si incap. 5, Descrierea ecranelor de test. Urmatoarele instructiuni constituie procedura normala pentru a realiza un test cu optiuniletiparire si memorare active.

1. Inlaturati toate impamantarile de siguranta de la echipamentul testat.2. Pentru a memora datele introduceti Data Key in soclul ei de pe panoul frontal si

intoarceti-o in sens orar. 3. Inchideti intrerupatorul principal. Indicatorul alb POWER trebuie sa lumineze. Ecranul

de pornire va fi afisat (Fig. 9) si dupa executatea diagnozei interne se va intra inecranul de test.

4. Reglati potentiometrul CONTRAST pentru o cat mai buna imagine.5. Examinati blocurile de stare de pe display din primul ecran de test ( fig. 9) pentru a va

asigura ca efectuati testul in conditiile dorite. Daca este necesar intrati in ecranulMENU si modificati-le.

6. In aceasta etapa operatorul poate tipari antetul masuratorilor si introduce ID. No. si/sautemperatura. Introducerea poate fi facuta si dupa terminarea testului. Apasati butonulHEADER pentru a tipari antetul la imprimanta. Apasati ID No. pentru a introduce ID-No. Operatorului i se va cere introducerea ID No. via creion cod bara. Daca s-a apasatID. No. din greseala se poate renunta la introducerea datelor prin apasarea butonuluide sub mesajul CANCEL. Apasati butonul TEMPERATURE pentru a introducetemperatura. Operatorului i se va cere sa introduca valoarea temperaturii via creion decitire cod bara. Daca se doreste renuntarea la introducerea temperaturii se va procedala fel ca la anularea introducerii descrisa la ID. No.

7. Selectati modul de test corespunzator cu ajutorul butoanelor LOW VOLTAGE LEDCONFIGURATION, prin apasarea butonului UST/GST corespunzator schemei alese.Modul selectat se va afisa in linia 1 pe LCD.

8. Inchideti butoanele interblocare externe (INTLK)9. Aduceti potentiometrul HIGH VOLTAGE CONTROL la ZERO START.10. Apasati butonul alb HV ON cand sunteti pregatit si energizati echipamentul de test.

Indicatorul rosu HIGH VOLTAGE ON va lumina si doua simboluri de inalta tensiune voraparea pe ecran.

11. Reglati potentiometrul HIGH VOLTAGE CONTROL pentru a obtine tensiunea dorita.Tensiunea de test si curentul vor fi afisate.

DACOM IMPEX S.R.L. V4.0

41

Page 42: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

ATENTIE Tensiunea inalta este de acum prezenta la terminalele echipamentuluitestat.

Nota Daca se depasesc 200mA se afiseaza mesajul “ MAXIMUM KVA REACHED - USEINDUCTOR TO TEST”. Daca curentul depaseste 210mA, tensiunea inalta va fidecuplata si mesajul “OVER CURENT TRIP OUT -PRESS ENTER TO CONTINUE”va fi afisat. Daca valoarea tensiunii inalte se schimba accidental in timpul efectuariimasuratorilor va fi afisat mesajul de eroare “SETTING OF HIGH VOLTAGECONTROL HAS CHANGED, PRESS ENTER TO CONTINUE”.

12. Apasati MEASURE cand sunteti gata pentru a face o masuratore. Se va aprindeindicatorul rosu TESTING si se va initia procesul de masurare. Cuvantul SINGLE va fiafisat in coltul dreapa jos al display-ului. La terminrea procesului de masurarerezultatele se vor afisa pe display (vezi fig. 17) iar tensiunea va fi deconectata de laechipamentul testat. Un rezultat tipic este aratat in fig. 17. Lampa rosie HIGHVOLTAGE va ramane aprinsa, indicand ca circuitul de HV este activ inca. Lampa rosieTESTING se stinge.

13. In acest moment se poate apasa butonul HEADER pentru a trimite antetul catreimprimanta. Apasati RECORD pentru a memora informatiile si a le trimite la printer.Numarul testului apare pe prima linie a LCD. Priviti figura 21 pentru un exemplu deimprimare a antetului si a rezultatelor.

14. Acum operatorul poate efectua un nou test. Daca unul din intrerupatoarele de protectieINTERLOCK a fost eliberat (deschis) apasand NEW TEST se intra in primul ecran detest (Fig. 11). In acest caz se reia procedura de la pasul 5. Daca intrerupatoarele deprotectie au fost mentinute inchise prin apasarea butonului NEW TEST se intra inecranul “ NEW TEST” (Fig. 18). In acest caz operatorul poate selecta o nouaconfiguratie de conectare (UST/GST) prin selectarea corespunzatoare LOW VOLTAGELEAD CONFIGURATION (noua configuratie apare pe primul rand).

15. Apasati RECALL VOLTAGE pentru a aplica inalta tensiune echipamentului de testatfara a mai trece prin zero HIGH VOLTAGE CONTROL si eventual ajustati tensiuneacorespunzator. Dupa apasarea HIGH VOLTAGE CONTROL se intra in al doilea ecrande test (Fig. 15).

ATENTIE Tensiunea inalta este de acum prezenta la terminalele echipamentuluitestat.

16. Apasati MEASURE atunci cand sunteti pregatiti pentru o noua masurare. La terminarenoile valori masurate vor fi afisate iar numarul testului se va incrementa.

17. Apasati butonul RECORD pentru a memora si imprima noile valori masurate.

18. Pasi 14 pana la 17 se repeta de atatea ori cat este necesar sau se selecteaza un noumod de test UST/GST.

DACOM IMPEX S.R.L. V4.0

42

Page 43: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

AVO INTERNATIONALDELTA - 2000

10 kV AUTOMATED INSULATION TEST SET

INSTRUMENT SERIALNO.:______________________________OPERATORSNAME:___________________________________EQUIPMENTIDENTIFICATION:___________________________EQUIPMENT SERIALNO.:_______________________________AMBIENTTEMPERATURE:______________________________RELATIVEHUMIDITY:__________________________________COMMENTS/NOTE:

DATE:11/22/96 10:28TEST ID NO.: XFMR - 123 - SS 3TEMPERATURE (°C): 18TEST MODE: UST: MEAS RED, GND BLUEMEASUREMENT: AC INSULATION TESTVOLTAGE: 12.03 kVCURRENT: 9.04 mA

7.51 mA @ 10 kVWATTS: 0.024 W XXX @ 10 kVPOWER FACTOR: 0.02%DISSIPATION FACTOR: 0.02%CAPACITANCE: 1993.3 pFINTERFERENCE: MEDIUM

Figura 21: Exemplu de antet si tiparire a rezultatelor.

19. La terminarea testelor readuceti HIGH VOLTAGE CONTROL la Zero si apoi apasatiHIGH VOLTAGEV OFF sau deschideti butonul de interblocare exterior, apoi inchidetialimentarea setului de test.

IN CAZ DE URGENTA

Tensunea inalta poate fi intrerupta imediat in caz de urgenta prinapasarea butonului HIGH VOLTAGE OFF, deschiderea butonului deinterblocare sau inchiderea intreruptorului de alimentare.

DACOM IMPEX S.R.L. V4.0

43

Page 44: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

ATENTIE Descarcati terminalele echipamentului testat cu un baston deimpamantare, apoi impamantati terminalele inainte de a desfacelegaturile aparatului. Intodeauna deconectati cablurile de laechipamentul testat si apoi de la aparat.

DACOM IMPEX S.R.L. V4.0

44

Page 45: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

MASURAREA CURENTULUI DE EXCITATIE LAMASURAREA CURENTULUI DE EXCITATIE LAMASURAREA CURENTULUI DE EXCITATIE LAMASURAREA CURENTULUI DE EXCITATIE LATRANSFORMATOARETRANSFORMATOARETRANSFORMATOARETRANSFORMATOARE

Treceti la executarea testelor numai dupa citirea si intelegerea capitolelor anterioare.

Pentru a reduce curentul de sarcina necesar realizati testele numai pentru infasurarile deinalta tensiune. Infasurarile in scurt de pe secundar tot vor fi detectate. Infasurarile de joasatensiune ce in serviciu sunt impamantate se vor mentine impamantate pentru acest test. Aplicati intotdeauna exact aceeasi tensiune fiecarei faze a transformatoarelor trifazate.Aceasta va minimiza erorile datorate oricaror neliniaritati dintre tensiune si curent. Pentruacelasi motiv testele urmatoare se vor face la aceeasi tensiune de test. Pentrutransformatoarele trifazate curentul de excitatie (magnetizare) in general este similar pentrudoua faze si semnificativ mai coborat pentru a treia, care este situata in cetrul miezului. Pentru transformatoare monofazate, infasurarile sunt energizate alternativ de la capeteopuse. Aceasta trebuie facuta si pentru transformatoare in triunghi trifazate daca curentulde excitatie este anormal. Magnetismul rezident datorat miezului va afecta rezultatelefoarte rar. Cu toate acestea, aceasta probabilitate poate fi luata in calcul daca curentul esteanormal de mare. Atentie, nu depasiti tensiunea nominala a echipamentului la efectuareatestelor.Testarea comutatoarelor cu ploturi se va face pentru pozitia acestora in pozitii extreme(min, max) petru teste de rutina.Urmatorii pasi sunt considerati procedura normala pentru efectuarea testelor curentilor deexcitatie (magnetizare). Se considera ca functiile tiparire si memorare sunt active.

1. Indepartati impamantarile de siguranta de la echipament.

2. Pentru a memora datele introduceti Data Key in locasul ei.

3. Inchideti intrerupatorul principal de alimentare al setului de test. Lampa POWERtrebuie sa se aprinda si ecranul de start este afisat pentru 5 secunde si dupaexecutarea rutinelor de autotestare se intra in ecranul de test.

4. Ajustati CONTRAST pentru o imagine optima.

5. Examinati blocurile de stare afisate, vedeti daca este selectata masurarea curentuluide excitatie si parametri doriti. De exmplu masuratorile se pot face cu optiuneNORMAL/REVERSE sau numai NORMAL, etc. Daca este necesar apasati MENU sifaceti modificarile corespunzatoare.

6. In aceasta etapa operatorul poate tipari antetul masuratorilor si introduce ID. No. si/sau temperatura. Introducerea poate fi facuta si dupa terminarea testului. Apasatibutonul HEADER pentru a tipari antetul la imprimanta. Apasati ID No. pentru aintroduce ID- No. Operatorului i se va cere introducerea ID No. via creion cod bara.Daca s-a apasat ID. No. din greseala se poate renunta la introducerea datelor prin

DACOM IMPEX S.R.L. V4.0

45

Page 46: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

apasarea butonului de sub mesajul CANCEL. Apasati butonul TEMPERATURE pentrua introduce temperatura. Operatorului i se va cere sa introduca valoarea temperaturiivia creion de citire cod bara. Daca se doreste renuntarea la introducerea temperaturiise va proceda la fel ca la anularea introducerii descrisa la ID. No.

7. Selectati modul de test corespunzator cu ajutorul butoanelor LOW VOLTAGE LEDCONFIGURATION, prin apasarea butonului UST/GST (UST: Measure Read, GroundBlue pentru testul initial ca in Fig.7) corespunzator schemei alese. Modul selectat se vaafisa in linia 1 pe LCD.

8. Inchideti butoanele de interblocare externe. (interlock)

9. Aduceti HIGH VOLTAGE CONTROL la ZERO START (pozitia de zero).

10. Apasati HIGH VOLTAGE ON atunci cand sunteti pregatit sa efectuati testele. LampaHIGH VOLTAGE se va aprinde si doua simboluri de inalta tensiune vor apareaintermitent pe ecran.

ATENTIE Tensiunea inalta este de acum prezenta la terminalele echipamentuluitestat.

11. Reglati HIGH VOLTAGE CONTROL pentru a obtine tensiune de test dorita. Valorilecurentului si tensiunii vor fi afisate pe LCD.

12. Apasati MEASURE atunci cand sunteti gata si efectuati testul. Se va aprinde beculTESTING si se va initia testul ( fie un singur test, fie in mod repetat, depinzand deOPERATION MODE ce a fost selectat in al doilea ecran meniu). La terminarerezultatele se afiseaza pe display si se decupleaza tensiunea de test. Un model estearatat in fig. 22. Indicatorul HIGH VOLTAGE ON va ramane aprins aratand ca circuitulde HV este in continuare activ (numai iesirea este deconectata), iar lampa rosieTESTING se va stinge.

DACOM IMPEX S.R.L. V4.0

46

Page 47: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Figura 22: Rezultatele testului Masurare Curent de Magnetizare

Obs. De notat ca circuitul de suprimare a interferentelor este automat dezactivat cand seface testul curent de excitatie, indiferent de indicatia afisata pe display.Nota

Daca curentul depaseste 210mA, tensiunea inalta va fi decuplata si mesajul “OVERCURENT TRIP OUT -PRESS ENTER TO CONTINUE” va fi afisat. Acest lucru sepoate intampla daca se executa testul pe infasurarea de inalta tensiune in triunghiiar legaturile dintre alte infasurari sunt impamantate ca in fig. 7.

13. Apasati butonul HEADER pentru a tipari antetul la imprimanta Apasati butonulRECORD pentru a memora si tipari rezultatele. Numarul testului apare pe primul rand.Studiati fig. 23 ce exemplifica antetul si rezultatele unui test.

14. Pentru a repeta masuratorile apasati NEW TEST apoi RECALL VOLTAGE ce va

repune sub tensiune infasurarea transformatorului testat fara a mai porni de la zero.Daca este necesar ajustati HIGH VOLTAGE CONTROL pentru a obtine noua tensiunede test dorita.

ATENTIE Tensiunea inalta este de acum prezenta la terminalele echipamentuluitestat.

15. Apasati MEASURE cand sunteti gata si repetati testul. De notat ca numarul testuluise va incrementa cu o unitate pentru fiecare test efectuat. La terminare rezulatele vor fiafisate.

DACOM IMPEX S.R.L. V4.0

47

Page 48: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

16. Apasati butonul RECORD pentru a memora si tipari rezultatele obtinute.

17. Pasi 14 la 17 se pot repeta de atatea ori cat se doreste pentru a efectua noi teste saupentru a le repeta.

18. La terminarea tuturor testelor aduceti HIGH VOLTAGE CONTROL in pozitia ZEROSTART, apasati HIGH VOLTAGE OFF sau deschideti butonul de interblocare, apoiinchideti intreruptorul principal.

IN CAZ DE PERICOL Inalta tensiune poate fi intrerupta de urgenta prin apasarea butonuluiHIGH VOLTAGE OFF, deschiderea butonului de interblocare sauinchiderea intrerupatorul de alimentare.

ATENTIE Descarcati terminalele transformatorului cu o prajina de impamantaresau impamantati aceste terminale inainte de a desface legaturile.Intodeauna deconectati mai intai legaturile de la transformator si apoi dela aparat.

DATE: 11/22/96 10:28TEST ID NO.: XFMR - 123 - SS 3TEMPERATURE (°C): 27.6TEST MODE: UST: MEAS RED, GND BLUEMEASUREMENT: XFMR EXCITATION TESTVOLTAGE: 7.03 kVCURRENT: 85.76 mA 122 mA @ 10 kV

Figura23: Exemplu test curent de excitatie-tiparire

DACOM IMPEX S.R.L. V4.0

48

Page 49: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Capitolul 6Capitolul 6INTRETINEREINTRETINERE

Utilizarea si intretinerea se va face numai de personal calificat familiarizat cu pericoleledatorate tensiunii inalte implicate in acest aparat. Cititi si intelegeti capitolul 2 referitor laprotectii si avertizari inainte de a actiona in vreun fel cu Setul de Test Automat.Intretinerea de rutina este tot ce se cere pentru acest aparat. Cablurile si conectorii se vorinspecta regulat pentru a fi sigur ca toate legaturile sunt OK. Partea exterioara a cutiilor sepoate sterge cu apa si detergent. Panoul de comanda se va putea sterge de asemenea cuo cirpa moale cu apa si detergent. Un spray obisnuit de curatat se poate folosi. Atentie lafereastra display-ului sa nu fie zgariata in timpul curatirii si la patrunderea apei prin gaurilesuruburilor.Cablurile se pot sterge cu izopropil sau alcool industrial aplicat cu o carpa.Distrugerea izolatiei cablurilor, in special a celui de HV va cauza o valoare reziduala atangentei de delta.

CALIBRARE CALIBRARE CALIBRARE CALIBRARE

Pe perioada garantiei nu este necesara calibrarea. Contactati fabrica sau cel mai apropiatdistribuitor daca apar probleme suspecte. O verificare completa a calibrarii, asa cum estedescrisa in acest capitol, este recomandat a se efectua cel mult la un interval de un an.Acest lucru confirma functionarea corecta si in limitele acceptate de toleranta ale circuitelorde joasa tensiune.

Verificarea completa a setului de test la 10 KV se va efectua de asemenea cel putin odatape an folosind Condensatorul de Referinta si DF- Capacitance and Dissipation FactorStandard (Cat. No. 670500-1) produs de AVO. Prin acest test se verifica functionareacorecta si in parametri de calibrare ai intregului set de test.

Pentru a efectua verificarea de calibrare prezentata mai jos se vor desface suruburile ceasigura panoul unitatii de comanda. Asezati unitatea de comanda pe un banc de lucru cupartea laterala in jos apoi scoateti panoul cativa cm in afara cutiei permitand astfel accesulla butonul cu revenire, aflat pe partea laterala sus a rakului placilor electronice.Potentiometri de calibrare, numerotati R1 la R10 sunt astfel accesibili si sunt asezati pepartea de sus a rakului placilor electronice.

1. Potentiometri vor fi in aceasta procedura setati si o secventa completa de verificare acalibrarii se va efectua. Unitatea de comanda trebuie lasata sa se incalzeasca circa 5min inaintea verificarii calibrarii.

2. Pentru a initia secventa de calibrare, care este controlata de microprocesor, apasati

DACOM IMPEX S.R.L. V4.0

49

Page 50: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

butonul MENU si apoi selectati optiunea Second Menu Screen apoi intrati in FULLCALIBRATION

3. Urmati secventele din tabelul 3 Test/Calibration, pasii 1 la 20 pentru a verifica operareaplacilor analogice si pentru a regla potentiometrele cu precizie. Tabelul 3 contine si unabreviar al posibilelor defecte in cazul functionarii defectuoase. Pentru avansarea lapasul urmator apasati butonul cu revenire de pe partea laterala a rakului electronic.

4. Pasii 21 la 24 din tabelul 3 verifica Releele Analogice si operarea placheteiRange/Mode. Pasul 25 initieaza urmatoarele 73 de secvente automate de testate peplacheta Relay si Range/Mode. Intregul test este realizat in 38 sec. O numaratoareinversa apare pe LCD.

La o trecere cu succes a testelor de calibrare nici un mesaj de eroare nu va fi afisat laterminarea numaratoarei inverse. Absenta unui mesaj inseamna ca totul este OK.

Un mesaj de eroare pentru testele ce se efectueaza automat in pasul 25 va avea formatulprezentat mai jos.

DIAGNOSTIC ERROR TEST #03 12DIAGNOSTIC ERROR TEST #06 08DIAGNOSTIC ERROR TEST #18 22DIAGNOSTIC ERROR TEST #56 14

Primul numar indica numarul testului din tabela 4. Al doilea numar indica numarul de bitieronati masurati de convertorul A/D ( 1 bit = 4,8828 mV).

Tabela 4 arata setarile corecte si acolo unde este posibil pentru fiecare din cele 73 testecomponentele posibil a fi defecte de pe placheta Relay and Range/Mode.

Tabelul 5 se refera la functionarea tuturor releelor (numerotate K) si a comutatoarelorCMOS (numerotate cu U)

5. Deconectati interupatorul principal, apoi desfaceti toate cablurile de la unitatea decomanda.

DACOM IMPEX S.R.L. V4.0

50

Page 51: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 3: Verificarea calibrarii placii analogiceTest/Calibration Check Sequence

Adjustment/Check Display Indication

Malfunction Checks or PossibleDefective Component on AnalogPCB

(1) “0 Cross” Detectorcheck

Will skip to next step if check isOK

Displays “No 0 crossing Detector”for malfunction

Recheck +15 V, -15 V, +10 V, - 10V, and +5 V supply voltages

Check for +5V 1/2 cycle squarewave at TP35

(2) “Phase lockedloop” check

Will skip to next step if check isOK

Displays “No Phase Locked Loop”for malfunction

Voltage at TP36 will be +5V iflocked and <6 V if unlocked

Defective U35 or U44

(3) A/D OFFSET Adjust R9 to between -9.995 and-10.004 (should trigger betweenH&L limits)

Defective U3, U11, U10, U15, U12Check for -10 V at TP6

(4) A/D GAIN Adjust R10

Adjust R10 to between 9.990 and10.000 (should trigger betweenH&L limits)

Defective U3, U11, U10, U15, U12Check for +10 V at TP6

(5) A/D ZERO Check Should be 0.000 ±0.050 V Defective U3, U11, U10, U15Check for 0 V at TP6

(6) C DAC OFFSET Adjust R7

Adjust R7 to 0.000 ±0.010 V Defective U3, U29, U45, U46, U47,U48, U49Check for 0 V at TP26 and TP6

(7) C DAC GAIN Adjust R3

Adjust R3 to 9.982 ±0.020 V Defective U3, U29, U45, U46, U47,U48, U49Check for 9.982 V at TP26 andTP6

(8) C DAC MINUSGAIN Check

Should be -9.982 ±0.020 V Defective U3, U29, U45, U46, U47U48, U49Check for -9.982 V at TP26 andTP6

(9) DF DAC OFFSET Adjust R8

Adjust R8 to 0.000 ±0.010 V Defective U3, U29, U45, U55, U56,U57, U58Check for 0 V at TP43 and TP6

(10) DF DAC GAIN Adjust R4

Adjust R4 to 9.982 ±0.020 V Defective U3, U29, U45, U55, U56,U57, U58Check for 9.982 V at TP43 andTP6

(11) DF DAC MINUSGAIN Check

Should be -9.982 ±0.020 V Defective U3, U29, U45, U55, U56,U57, U58Check for --9.982 V at TP43 andTP6

(12) C SUPP DACOFFSET Adjust R6

Adjust R6 to 0.000 ±0.010 V Defective U3, U29, U39, U40, U41,U42, U54Check for 0 V at TP25 and TP6

(13) C SUPP DACGAIN Check

Should be 9.689 ±0.20 V Defective U3, U29, U39, U40, U41,U42, U54Check for 9.689 V at TP25 andTP6

DACOM IMPEX S.R.L. V4.0

51

Page 52: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 3: Verificarea calibrarii placii analogice(14) C SUPP DACMINUS GAIN Check

Should be -9.689 ±0.20 V Defective U3, U29, U39, U40, U41,U42, U54Check for -9.689 V at TP25 andTP6

(15) DF SUPP DACOFFSET Adjust R5

Adjust R5 to 0.000 ±0.010 V Defective U3, U29, U54, U60, U61,U62, U63Check for 0 V at TP46 and TP6

(16) DF SUPP DACGAIN Check

Should be 9.689 ±0.20 V Defective U3, U29, U54, U60, U61,U62 U63Check for 9.689 V at TP46 andTP6

(17) DF SUPP DACMINUS GAIN Check

Should be -9.689 ±0.20 V Defective U3, U29, U54, U60, U61,U62, U63Check for -9.689 V at TP46 andTP6

(18) VOLTAGECHANNEL Check

Should be 8.000 ±0.010 V Defective U1, U3, U4, U6, U7,U12, U34Check for 10.0 V P-P square waveat TP4;16.0 V P-P square wave at TP24and TP7;+8.0 V dc at TP11 and TP6

(19) MEAS CURRENTCHANNEL Check

Should be 8.000 ±0.010 V Defective U1, U3, U5, U6, U7,U12, U34Check for 10.0 V P-P square waveat TP4; 16.0 V P-P square wave atTP3; +8.0 V dc at TP5 and TP6

(20) TOTALCURRENT CHANNELCheck

Should be 5.000 ±0.010 V Defective U1, U3, U6, U7, U12,U27, U34Check for 10.0 V P-P square waveat TP4; +5.0 V dc at TP19 and TP6

(21) FILTER PHASE Adjust R2

Adjust R2 to 0.000 ±0.050 V Defective U3, U17, U34, U45, U59Check for nom 27 V P-P squarewave at TP33; 0 V dc at TP2 andTP6Check for nom 6.0 V rms at TP45

(22) C PHASERECTIFIER Check

Should be -1.150 ±0.30 V Defective U3, U23, U34, U45, U59Check for nom 27 V P-P squarewave at TP38; 1.15 V dc nom atTP20 and TP6

(23) DF PHASERECTIFIER Adjust R1

Adjust R1 to 0.000± 0.050 V Defective U3, U17, U34, U45, U59Check for nom 27 V P-P squarewave at TP33; 0 V dc at TP2 andTP6

(24) C PHASERECTIFIER Check

Should be -1.150 ±0.30 V Defective U3, U23, U34, U45, U59Check for nom 27 V P-P squarewave at TP38; -1.15 V d c nom atTP20 and TP6

(25) Overall check ofcomplete Analog PCB,Relay PCB, andRange/Mode PCB

Instrument makes 73 diagnosticself-checks within 38 seconds. Atend of countdown, there shouldbe no diagnostic error.

Refer to Table 4 for explanation ofPCB and diagnostic error testnumber and magnitude of error.

DACOM IMPEX S.R.L. V4.0

52

Page 53: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 4: Relay and Range/Mode PCB Calibration Checks

TestNo.

MeasChanC/DF

NX

Winding

(Turns)

NS

Winding

(Turns)

Multiplier DAC & Range Settings

Analog

U14Gain

ErrorAllowed

A/DBits

Possible DefectiveComponent (R)Relay PCB (R/M) Range/ModePCB

01

02

03

04

05

06

07

08

09

C

C

C

C

C

C

C

C

C

0T

10T

10T

100T

100T

1T

1T

1T

1T

0T

10T

10 x 1T

100T

10 x10T

1T

1T

2T

0T

All 4 DACs set to 0

All 4 DACs set to 0

All 4 DACs set to 0

All 4 DACs set to 0

All 4 DACs set to 0

All 4 DACs set to 0

All 4 DACs set to 0

C DAC -0.5 FS

C DAC +0.5 FS

10

10

10

10

10

10

100

100

100

10

10

10

10

10

10

102

61

61

See steps 21 - 24of Table 3.

K12, U9, U3 (R)K18, U8, Q9, (R/M)K30, U9, U6 (R)K18, U8, Q9 (R/M)K2, U9, U1 (R)K19, U8, Q11 (R/M)K20, U9, U4 (R)K19, U8, Q11 (R/M)K22, U9, U5 (R)K16, U8, Q12 (R/M)K22, U9, U5 (R)K16, U8, Q12 (R/M)K22, U9, U5 (R)K16, U8, Q12 (R/M)K21, U9, U5 (R)K16, U8, Q12 (R/M)

101112

CCC

0T0T0T

0T0T0T

C, DF, and DF SUPPDACs set to 0 (steps 10, 11,12)

C SUPP DAC+FS range1C SUPP DAC+FS range2C SUPP DAC+0.2 FSrange 3

1011

8282164

U15, U21, U27 (R)K39, U9, U7 (R)K40, U9, U4 (R)

131415

DFDFDF

0T0T0T

0T0T0T

C, DF, and C SUPP DACsset to 0 (steps 13, 14, 15)

DF SUPP DAC+FS range1DF SUPP DAC+FS range2DF SUPP DAC+0.2 FSrange 3

1011

8282164

U12, U18, U24 (R)K31, U9, U6 (R)K32, U9, U6 (R)

DACOM IMPEX S.R.L. V4.0

53

Page 54: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 4: Relay and Range/Mode PCB Calibration Checks16

17

17181920

21

22

23

24

C

C

CCCCC

CC

C

C

C

0T

0T

0T0T0T0T0T

0T0T

0T

0T

0T

0T

100T

200T300T400T500T500T

600T700T

800T

900T

1000T

All 4 DACs set to 0

All 4 DACs set to 0

All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0C SUPP DAC set to -2176bitson range 3New ref value meas in thisstepC SUPP DAC set to -2176bits on range 3C SUPP DAC set to -2176bits on range 3C SUPP DAC set to -2176bits on range 3C SUPP DAC set to -2176bits on range 3

1

1

11111

11

1

1

1

10

61

4444

4

4

4

4

See steps 21 - 24of Table 3.

Open ckt if error>41 bits K2, U1, U9 (R) K3, U9, U1 (R)K4, U9, U1 (R)K5, U9, U1 (R)K6, U9, U1 (R)K39, K40, U9, U7(R)

K42, U9, U1 (R)K41, U9, U1 (R)

K8, U9, U2 (R)

K9, U9, U2 (R)

K10, U9, U2 (R)

DACOM IMPEX S.R.L. V4.0

54

Page 55: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 4: Relay and Range/Mode PCB Calibration Checks25

26

26272829

30

31

32

33

343536373839404142

C

C

CCCCC

CC

C

C

C

C

CCCCCCCCC

0T

0T

0T0T0T0T0T

0T0T

0T

0T

0T

0T

0T0T0T0T0T0T0T0T0T

0T

10T

20T30T40T50T50T

60T70T

80T

90T

100T

1T

2T3T4T5T6T7T8T9T10T

All DACs set to 0

All 4 DACs set to 0

All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0C SUPP DAC set to -2176bitson range 2New ref value meas in thisstepC SUPP DAC set to -2176bits on range 2C SUPP DAC set to -2176bits on range 2C SUPP DAC set to -2176bits on range 2C SUPP DAC set to -2176bits on range 2All 4 DACs set to 0 New ref value measAll 4 DACs set to 0All 4 DACs set to 0 All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0All 4 DACs set to 0

10

10

1010101010

1010

10

10

10

10

101010101010101010

10

61

10101010

10

10

10

10

101010101010101010

See steps 21 - 24of Table 3.

Open ckt if error>41 bits K12, U9, U3 (R)K13, U9, U3 (R)K14, U9, U3 (R)K15. U9, U3 (R)K16, U9, U3 (R)K39, U9, U7 (R)

K17, U9, U3 (R)K7, U9, U3 (R)

K18, U9, U4 (R)

K19, U9, U4 (R)

K20, U9, U4 (R)

K22, U9, U5 (R)

K23, U9, U5 (R)K24, U9, U5 (R)K25, U9, U5 (R)K26, U9, U5 (R)K33, U9, U5 (R)K27, U9, U5 (R)K28, U9, U6 (R)K29, U9, U6 (R)K30, U9, U6 (R)

C, C SUPP, DF SUPPDACs set to 0 (steps 43-47)

DACOM IMPEX S.R.L. V4.0

55

Page 56: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 4: Relay and Range/Mode PCB Calibration Checks4344

44454647

48

49

50

51

DFDF

DFDFDFDFDF

DFDF

DF

DF

DF

0T0T

0T0T0T0T0T

0T0T

0T

0T

0T

0T100T

200T300T400T500T500T

600T700T

800T

900T

1000T

DF DAC +FS range 3DF DAC +FS range 3

DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3C & DF SUPP DACs setto -2176 bits on range 3New ref value in this stepC & DF SUPP DACs setto-2176 bits on range 3C & DF SUPP DACs setto -2176 bits on range 3C & DF SUPP DACs setto -2176 bits on range 3C & DF SUPP DACs setto -2176 bits on range 3

11

11111

11

1

1

1

1061

4444

4

4

4

4

K34, K35, U9, U7(R)Open ckt if error>41 bits K2, U9, U1 (R)K3, U9, U1 (R)K4, U9, U1 (R)K5, U9, U1 (R)K6, U9, U1 (R)K39, K40, U9, U7(R)

K42, U9, U1 (R)K41, U9, U1 (R)

K8, U9, U2 (R)

K9, U9, U2 (R)

K10, U9, U2 (R)

DACOM IMPEX S.R.L. V4.0

56

Page 57: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 4: Relay and Range/Mode PCB Calibration Checks

52

53

53545556

57585960

616263646566676869

DF

DF

DFDFDFDFDF

DFDFDFDFDFDF

DFDFDFDFDFDFDFDFDFDF

0T

0T

0T0T0T0T0T

0T0T0T0T0T0T

0T0T0T0T0T0T0T0T0T0T

0T

10T

20T30T40T50T50T

60T70T80T90T100T0T

1T2T3T4T5T6T7T8T9T10T

C, C SUPP, and DFSUPP DACs set to 0 (steps 52-56)DF DAC +FS range 3

DF DAC +FS range 3

DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3C SUPP and DF SUPPDACs set to -2176 bits on range2 (steps 57 to 60)New ref value meas in thisstepSet C, C SUPP, DF SUPPDACs to 0 (steps 61-69) DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3DF DAC +FS range 3

10

10

1010101010

1010101010

10101010101010101010

10

61

10101010

10101010

101010101010101010

See steps 21-24 ofTable 3.K30, K35, U9, U7(R)Open ckt if error>41 bits K12, U9, U3 (R)K13, U9, U3 (R)K14 ,U9, U3 (R)K15, U9, U3 (R)K16, U9, U3 (R)K39, K40, U9, U7(R)

K17, U9, U3 (R)K7, U9, U3 (R)K18, U9, U4 (R)K19, U9, U4 (R)K20, U9, U4 (R)See steps 21 - 24of Table 3.

K34, K35, U9, U7(R)K23, U9, U5 (R)K24, U9, U5 (R)K25, U9, U5 (R)K26, U9, U5 (R)K33, U9, U5 (R)K27, U9, U5 (R)K28, U9, U6 (R)K29, U9, U6 (R)K30, U9, U6 (R)

70717273

DFDFDFDF

0T0T0T0T

0T50T50T50T

C, C SUPP, DF SUPPDACs set to 0 (steps 70-73)DF DAC +FS range 3DF DAC +FS range 3DF DAC +0.1 FS range 4DF DAC +FS range 2

10101010

1010210241

See steps 21-24 ofTable 3.K34, K35, U9, U7(R)K34, K35, U9, U7(R)K34, K35, K36, U9,U7 (R)K34, U9, U7 (R)

DACOM IMPEX S.R.L. V4.0

57

Page 58: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

Tabelul 5: Function of Relays and CMOS SwitchesRelay Function Relay FunctionK1K11K3, K14K5, K6,K13K10K9K7K4K2, K8K12K15, K17K16K18K19

K3, K9K1, K7K4, K10K2, K8K6, K12K5, K11K22K13K14

K1K2K3K4K5K6K42K41K8K9K10

Power breaker (top panel)Line relay (Input PCB)HV ON relay (Input PCB)HV OUTPUT relay (InputPCB)Reverse polarity (Input PCB)Open ground (Input PCB)Over V & I relay (Input PCB)Measure lamp relay (InputPCB)Triac control (Input PCB)Short triac (Input PCB)LV lead short (Input PCB)Nx 0T (Range/Mode PCB)Nx 1T (Range/Mode PCB)Nx 10T (Range/Mode PCB)Nx 100T (Range/Mode PCB)

Red LV 1 (Range/ModePCB)Red LV 2 (Range/ModePCB)Blue LV 1 (Range/ModePCB)Blue LV 2 (Range/ModePCB)GST (Range/Mode PCB)UST (Range/Mode PCB)Nx CALIB (Range/ModePCB)Cs SHORT (Range/ModePCB)Nx CALIB (Range/ModePCB)

Ns 100 turn 0 (Relay PCB)Ns 100 turn 1 (Relay PCB)Ns 100 turn 2 (Relay PCB)Ns 100 turn 3 (Relay PCB)Ns 100 turn 4 (Relay PCB)Ns 100 turn 5 (Relay PCB)Ns 100 turn 6 (Relay PCB)Ns 100 turn 7 (Relay PCB)Ns 100 turn 8 (Relay PCB)Ns 100 turn 9 (Relay PCB)Ns 100 turn 10 (Relay PCB)

K11K12K13K14K15K16K17K7K18K19K20

K21K22K23K24K25K26K33K27K28K29K30

K34K35K36K37K38K39K40K31K32K25K21,K24K20,K23

CMOSSwitches U34U32

U20U3U59U45U54

NS 10 turn 0 (Relay PCB)NS 10 turn 1 (Relay PCB)NS 10 turn 2 (Relay PCB)NS 10 turn 3 (Relay PCB)NS 10 turn 4 (Relay PCB)NS 10 turn 5 (Relay PCB)NS 10 turn 6 (Relay PCB)NS 10 turn 7 (Relay PCB)NS 10 turn 8 (Relay PCB)NS 10 turn 9 (Relay PCB)NS 10 turn 10 (Relay PCB)

NS 1 turn 0 (Relay PCB)NS 1 turn 1 (Relay PCB)NS 1 turn 2 (Relay PCB)NS 1 turn 3 (Relay PCB)NS 1 turn 4 (Relay PCB)NS 1 turn 5 (Relay PCB)NS 1 turn 6 (Relay PCB)NS 1 turn 7 (Relay PCB)NS 1 turn 8 (Relay PCB)NS 1 turn 9 (Relay PCB)NS 1 turn 10 (Relay PCB)

% DF range 2 (Relay PCB)% DF range 3 (Relay PCB)% DF range 4 (Relay PCB)C fine bal range 2 (Relay PCB)C fine bal range 3 (Relay PCB)C SUPP range 2 (Relay PCB)C SUPP range 3 (Relay PCB)DF SUPP range 2 (Relay PCB)DF SUPP range 3 (Relay PCB)Range CT, sec (Range/Mode PCB)Range CT, pri (Range/Mode PCB)Range CT tap (Range/Mode PCB)

Analog PCB Measure/calibrateGain 1 (always) A1 Logic LO A2, A3, A4 Logic HIGain 1, 10, 100, 1000Multiplexer 0 V initialLine ref V/test ref VMeasurement/DAC calMeasurement/DAC cal

DACOM IMPEX S.R.L. V3.0

58

Page 59: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

REPARATIIREPARATIIREPARATIIREPARATII

AVO International ofera servicii complete de service si reparatie. Va rugam oferiti toateinformatiile legate de functionarea incorecta a setului de test incluzand problemeleremarcate, simtomele, situatia concreta in care au aparut. Trimiteti la reparat DELTA -2000 incutile de transport si toate cablurile ce insotesc aparatul.

DACOM IMPEX S.R.L. este autorizata de catre AVO pentru a efectua reparatiile in garantiesi post garantie.

DACOM IMPEX S.R.L. V3.0

59

Page 60: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

PIESE DE SCHIMBPIESE DE SCHIMBPIESE DE SCHIMBPIESE DE SCHIMB

Descriere Part Number

Bag, canvas for cables -sacose de canava pentru cabluri 34460-010Cable, ground (hook lug) -cablu de impamantare 4702-7Cable, high-voltage - cablu inalta tensiune 30012-5Cable, interconnect - cablu interconectare 27978Cable, interconnect - cablu interconectare 27979Cable, PC interface - cablu pentru interfata cu PC 29017Cable, printer interface - cablu pt. imprimanta 29016Data key - Memorie de tip cheie 30603Data key interface box - cutie interfata Data Key 30606Data key interface box (for 672001-47) - cutie interfata Data Key 30606-1Knob (CONTRAST control)- buton contrast 4690-31Knob (HIGH VOLTAGE CONTROL)- buton 4690-28Lead, low-voltage (red) - cablu joasa tensiune rosu 25572-1Lead, low-voltage (blue) - cablu joasa tensiune albastru 25572-2Line cord (for Cat. No. 672001) - cablu alimentare 17032-4Line cord (for Cat. No. 672001-47) - cablu alimentare 17032-2Pilot light, white (1 per unit) - lampa alba 27931-3Pilot light, yellow (1 per unit) - lampa galbena 27931-4Pilot light, red (2 per unit) - lampa rosie 27931-5Printer - imprimanta 29015Printer (for Cat No. 672001-47) - imprimanta 29015-1Safety interlock hand switch 8 ft (2.4 m) - comutator blocare 34460-020Safety interlock hand switch 70 ft (21 m) - comutator blocare 34460-0

DACOM IMPEX S.R.L. V3.0

60

Page 61: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

GLOSAR GLOSAR GLOSAR GLOSAR

Semnificatia simbolurilor folosite in acest manual

Conductor de protectie terminat cu un surub fluture pentru conectarea la pamant.

Terminal de impamantare

Simbol de inalta tensiune prezent in al doilea si al treilea ecran de test (FIG. 15 si 16), indicand prezenta tensiunii inalte la terminale.

arc-over Arc electric intre doua conductoare sau intre un conductor si pamant.

bridge symbols Simboluri folosite la punte : R = red-rosu, B = blue-albastru, and G = green-verde.

CAP Capacitate

dissipation factor Raportul dintre energia activa si energia totala pentru un ciclu.

GST Grounded specimen test - echipamente impamantate.

hot collar O banda conductiva utilizata pentru testarea pierderilor dielectrice la izolatoare..

LCD Liquid crystal display- display cu cristale lichide

LED Light-emitting diode- dioda emitatoare de lumina

permittivity Capacitatea unui dielectric de a stoca energie potentiala sub actiunea unui camp electric.

pothead Un dispozitiv ce sigileaza terminalul unui cablu si impiedica scurgerea lichidului izolator.

power factor (PF)- raportul dintre pierderile in wat si puterea totala rms (VA)

safety ground jumper Conexiune temporala, nu face parte din accesorii, facuta intre terminalele echipamentului si pamant.

safety ground stick Prajina de protectie izolata folosita pentru punerea la pamant a unui terminal .

UST Ungrounded specimen test- test echipamente neimpamantate.GST Grounded specimen test- test echipamente impamantate.

DACOM IMPEX S.R.L. V3.0

61

Page 62: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000

GARANTIEGARANTIEGARANTIEGARANTIE

AVO International garanteaza acest instrument vandut de el sau agentul sau autorizat, fatade defecte ale instrumentului sau ale materialelor folosite, pentru o perioada de 12 luni dela data livrarii. Pe perioada garantiei AVO International va inlocui sau repara partile defectesau aparatul, conform considerentelor proprii, pentru aparatele care indeplinesc conditiileurmatoare:- Instrumentul este returnat corect impachetat si transportat cu pre- autorizarea agentului

nostru.(DACOM IMPEX)- Instrumentul nu a fost modificat, reparat, de persoane neautorizate.- Conform examinarii efectuate de specialisti se constata ca defectul nu se datoreaza

gresitei utilizari, neglijenta, accidente, depasirea conditiilor de mediu, sau conectareainstrumentului la echipamente incompatibile.

Aceasta garantie este exclusiva si este oferita si acceptata in loc de orice alta garantie,expresa sau inteleasa, si constitue intreaga obligatie a producatorului catre cuparator. AVOInternational refuza sa recunoasca garantiile implicate de comercializarea acestuia sistabilite cu un scop anume. Nu ne asumam raspunderea, in orice situatie, pentru pierderilesau distrugerile provocate, de pierderile de profit rezultate, de ranirea personalului propriu,pentru orice alte pagube provocate cumparatorului sau altei persoane implicate in utilizareainstrumentului.

DACOM IMPEX S.R.L. V3.0

62

Page 63: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Data Key Program de descarcare

SECTIUNEA IISECTIUNEA II

DXDKEY - PROGRAM DE DESCARCAREDXDKEY - PROGRAM DE DESCARCARE

DACOM IMPEX S.R.L. V4.0

63

Page 64: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Data Key Program de descarcare

DXDKEY -DXDKEY - PROGRAM DE DESCARCAREPROGRAM DE DESCARCARE

INTRODUCEREINTRODUCEREINTRODUCEREINTRODUCERE

DXDKEY este un program utilitar pentru descarcarea datelor continute in EEPROM-ul DataKey al Trusei de tangenta de delta DELTA 2000. Acest program comunica cu modululData Key PKS232 pentru a transfera datele in PC

Odata aduse in PC datele pot fi salvate in fisiere in format delimitat de vigula sau spatiu,fisiere ce pot fi apoi utilizate cu un program de baze de date sau cu un program de calcultabelar. Acest program poate rula pe sisteme de operare Windos 95 sau NT.Programul DXDKEY poate fi utilizat doar pentru vizualizarea datelor sau pentru stergereamemoriei Data Key pentru a o reutiliza cu trusa Delta 2000.

DXDKEY a fost dezvoltat de catre Data-X Research pentru a fi distribuit gratuit si a fi utilizatcu trusa AVO Delta 2000. Pentru ca DXDKEY este un soft gratuit, suportul tehnic estelimitat la informari si actualizari ocazionale ce pot fi gasite pe site-ul www.avointl.com.

DXDKEY nu este garantat sau asigurat in nici un fel, iar utilizatorii il pot descarca, instala siutiliza asa cum este, pe riscul propriu. Documentatia nu este de asemenea garantata sipoate fi cu erori, iar Data-X Research i-si rezerva drepul de a modifica softwareul saudocumentatia fara un prealabil anunt.

Speram ca veti gasi DXDKEY usor de utilizat si am amprecia foarte mult sugestiile dvs sirapoarte despre defecte de functionare.

DREPTURIDREPTURIDREPTURIDREPTURI

Softwareul si documentatie Copyright © 1998 Data-X Research. Toate drepturile rezervate.Publicarea separata sau copierea Programul DXKEY sau a documentatiei sau oricare dincomponentele sale este interzisa.

Logoul Delta-X si "Delta-Research" sunt denumiri de marca inregistrata Hydra-CentaurusTehnologies Inc.

Logoul AVO este denumire de marca inregistrata AVO International.Microsoft si Windows sunt denumiri de marca inregistrata Microsoft Corporation.Toate celelalte nume de marci sunt denumiri de marca inregistrata ale companiilorrespective.

DACOM IMPEX S.R.L. V4.0

64

Page 65: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Data Key Program de descarcare

CERINTE CALCULATORCERINTE CALCULATORCERINTE CALCULATORCERINTE CALCULATOR

Nota: Pentru a rula DXDKEY sub Windows NT 4.0 este nevoie de Service Pack 2.Utilitarele service Pack pentru Windows NT sun disponibile la Microsoft Co.

� 486 sau Pentium cu sistem de operare Windows 95 sau Windows NT 4.0� Pana la 3MB spatiu liber pe hard disk.� Display VGA sau mai bun� Mouse sau echivalent� Port serial de comunicare pentru descarcare date� Data Key PKS-232 si cablu.

INSTALAREINSTALAREINSTALAREINSTALARE

Programul se gaseste pe 2 diskete livrate odata cu echipamentul. Pentru a instalaprogramul rulati programul SETUP.EXE si urmati instructiunile.

Pentru a sterge programul DXDKEY de pe calculator folositi functiile Add/RemovePrograms din Windows Control Panel. Fisierele de date nu sunt sterse odata cu stergereaprogramului DXDKEY.

SETARILE PORTULUI SERIALSETARILE PORTULUI SERIALSETARILE PORTULUI SERIALSETARILE PORTULUI SERIALLansati programul DXDKEY si din meniul Option selectati Serial port Options.

In fereastra care apare introduceti:� Numarul portului serial ce este folosit. Uzual 1 sau 2.� Viteza de transfer este 9600. Daca doriti s-o schimbati aceasta trebuie modificata si in

PKS-232.� Paritatea este setata pe None.� Bitii de Start si Stop sunt afisati spre informare si nu poat fi modificati,

FORMATUL FISIERELOR DE DATEFORMATUL FISIERELOR DE DATEFORMATUL FISIERELOR DE DATEFORMATUL FISIERELOR DE DATE

Lansati programul DXDKEY si din meniul Option selectati Data File Options.

Selectati sau alegeti un delimitator de coloane ( uzual Tab-spatiu sau virgula), caracterul derecunoastere pentru text ( simplu sau dual- Text Qualifier) si formatul datelor.

Delimiter si Text Qualifier sunt utilizate pentru salvarea si incarcarea datelor. Data formateste utilizat pentru formatarea datelor atunci cand se incaraca din cheie sau sau atuncicand se vizualizeaza un fisier de date.

DACOM IMPEX S.R.L. V4.0

65

Page 66: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Data Key Program de descarcare

Optiunea Also Save Raw Data va ramane in mod normal neselectata. Este utilizata pentrua salva datele in format text hexazecimal pentru depanare.

INACARCAREA DATELOR DIN MEMORIA TIP CHEIEINACARCAREA DATELOR DIN MEMORIA TIP CHEIEINACARCAREA DATELOR DIN MEMORIA TIP CHEIEINACARCAREA DATELOR DIN MEMORIA TIP CHEIE

Conectati modulul interfata PKS232 la sursa de alimentare prin intermediul cablului dealimentare si apoi conectati cablul RS232 intre modul si portul Comm din PC. Comutatibutonul de alimentare al modulului si introduceti Data Key in soclu, dupa care excutati clikcu mouseul pe butonul Download. Puteti acum vizualiza, edita si salva fisierul respectiv.Aceste actiuni se pot repeta dupa dorinta sau puteti proceda la descarcarea informatiilordin alte memorii de tip Cheie.

Montarea modului PKS-232

� Conectati modulul interfata PKS-232 la un port serial liber al calculatorului utilizandcablul furnizat odata cu modulul.

� Conectati modulul interfata PKS-232 la sursa de alimentare si comutati butonul dealimentare al modulului. Cablul de alimentare si comutatorul de pornire se afla pespatele modulului.

Crearea sau deschiderea unui fisier de date

� Daca doriti sa creati un nou fisier de date selectati optiunea New din meniul File. Tabelace va apare este goala si capul de tabel standard al programului DXDKEY sun afisate.

� Daca doriti sa introduceti datele intr-un fisier existent (sau sa le adaugati), selectatioptiunea Open din meniul File, si deschideti fisierul inainte de a descarca datele.Continutul tabelului este gol, capul de tabel este cel al primului rand iar datele cititi vor fiinregistare in randurile acestei tabele.

Inceperea descarcarii

� Inserati memoria Data Key in modulul PKS-232 si porniti-l.� Selectati Read Data Key din meniul File. O fereastra de dialog va apare, informandu-va

ca portul serial a fost deschis. Daca numarul de port este invalid sau portul este folositde catre alta aplicatie, inchideti fereastra si rezolvati problema inainte de o nouaincercare.

� Daca portul serial este deschis efectuati clik cu mouseul pe butonul Download Data dinbareta de meniu principala (afisata in partea de sus a ferestrei). Daca apare o eroareinchideti dialogul de incarcare, remediati problema si repetati.

� Incarcarea datelor dureaza aproximativ 10 secunde. In linia de mesaje (partea de jos aferestrei) este afisat numarul de inregistari descarcate (numarul de masuratori) iar peecran vor fi afisate aceste inregistrari.

� Vizualizati si editati datele (proceduri prezentate in paragrafele urmatoare).

DACOM IMPEX S.R.L. V4.0

66

Page 67: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Data Key Program de descarcare

STERGEREA MEMORIEI DATA KEYSTERGEREA MEMORIEI DATA KEYSTERGEREA MEMORIEI DATA KEYSTERGEREA MEMORIEI DATA KEY

Atentie: Prin sergere toate informatiile continute in memoria Data Key vor fi pierdute. Dupastergere memoria Data Key va trebui initializata de catre Delta 2000.

� Inserati memoria Data Key in modulul PKS-232 si porniti-l. Selectati Erase Data Key dinmeniul File.

� Dupa ce confirmati actiunea de stergere a datelor o fereastra de dialog va apareinformandu-va ca portul serial a fost deschis.

� Efectuati clik cu mouseul pe butonul Erase Data Key din bareta de meniu principala (afisata in partea de sus a ferestrei). Actiunea dureaza aproximativ 2 secunde si nu poatefi intrerupta.

VIZUALIZAREA SI EDITAREA DATELORVIZUALIZAREA SI EDITAREA DATELORVIZUALIZAREA SI EDITAREA DATELORVIZUALIZAREA SI EDITAREA DATELOR

Vizualizare

Programul DXDKEY se poate folosi pentru a inspecta datele inccarcate din Data Key saudintr-un fisier exiztent. Ecranul primcipal con6tine informatia sub forma tabelara. Prindefilare pe orizontala si verticala, utilizand mouseul sau tasatura. se pot vizualiza toateinregistrarile. Fereastra poate fi redeimensionata. Prntr-un dublu clik pe oricare rand sedeschide fereastra Test Data Record pentru a vedeea separat fecare inregistrare. Aceastafereastra se poate redimensiona si are o bareta de unelte si cu butoane de navigare, Copy.Delete si dimensiune Font.

Editare date nemasurate

Campurile referitoare la identificarea echipamentului, si temperatura dintr-o inregistare potfi editate. De exemplu pentru a introduce sau corecta identificatorul echipamentului intr-oinregistrare se face clik pe coloana corespunzatoare Equipment ID din inregistrarea doritasi se introduce de la tastatura identificatorul. Prin apasarea tastei Esc se iese din regimulde editare campuri. Prin apasare Ctrl-z se intra din nou in regimul de editare. Sedeplaseaza cursorul pe alt rand sau coloana pentru preluare date si oprirea editarii.

Oricare alt camp cu informatii nemasurate poate fi editat.Toate campurile ce contin informatii masurate de catre tangenta nu pot fi editate.

Dimensionarea sau ascunderea unei coloane

Se poate modifica dimensiunea oricarei coloane prin clik pe marginea coloanei respectivecu butonul stang al mouseului uramata de tragerea acesteia.

NOTA: Daca micsorati o coloana pana la zero sau aparoape de zero ca latime, aceasta vafi omisa la tiparire sau la salvare.

DACOM IMPEX S.R.L. V4.0

67

Page 68: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Data Key Program de descarcare

Tiparire

Selecatati comanda de Print din meniul File pentru a tipari datele prezentate tabelar.Dimensiunea coloanelor va fi cea aratata pe ecran. Nu exista alte optiuni de tiparire decatcele oferite de fereastra Print Dialog a imprimantei instalate in PC-ul dvs.

Stergere

Marcati unul sau mai multe randuri si apasati tasta Delete sau alegeti comanda Delete dinmeniul File.

Cut, Paste si Copy

Subliniati unul sau mai multe randuri si alegeti comanda Copy din meniul File pentru acopia datele sublinate in memoria tampon (Clipboard) a sistemului Windows, intr-un formatcare permite recopierea (Paste) intr-o foaie de calcul tabelar. Daca alegeti Cut in loc deCopy inregistrarea respectiva va fi stersa si tot odata memorata in Clipbord.

Daca faceti clik pe butonul Copy in fereastra Test Data Record inregistrarea din fereastrava fi copiata in Windows Clipboard in format text, separat prin spatiu. Poate fi apoirecopiata intr-o foaie de calcul tabelar.

Save si Save As

Comanda Save din meniul File salveaza datele si tabelul intr-un fisier de tip text utilizanddelimitatorul si caracterul de text deja ales in Data Files Options. Datele continute incoloanele cu lungime zero nu sunt salvate. Comanda Save As permite sa specificati unnume de fisier si director inainte de a salva datele.

Pentru functii de editari mai complexe se poate utiliza o foaie de calcul tabelar.

Adaugarea unor noi date intr-un fisier

Se selecteaza prin comanda Open File din meniul File fisierul ce se doreste a fi modificat.Propietatile fisierului trebuie sa corespunda cu cele ale fisierului din Data Key ( delimitator,etc). Daca acestea nu corespund se va cere modificarea lor.Daca incaracti date din Data key dupa ce a-ti incarcat deja un fisier datele se vor adaugadupa ultima inregistrare existenta.

Atentie: Numai coloanele cu nume identice cu cele din memoria Data Key vor receptionadate. Coloanele din memoria Data Key care nu au corespondent in fisier nu vor fi incarcate.

Dupa editare sau stergere de date se poate salva fisierul sub numele initial sau sub un nou

DACOM IMPEX S.R.L. V4.0

68

Page 69: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Data Key Program de descarcare

nume prin optiunea Save As.

SUPORTSUPORTSUPORTSUPORT

Pentru ca DXDKEY este oferit gratis Delta-X Research nu ofera linie telefonica de service.Exista totusi o pagina DXDKEY de suport in site-ul Delta-X Research,Http://www.hydracen.com/dx unde puteti gasi informatii ajutatoare precum:� Raspunsuri la intrebarile cele mai frecvente.� Formular de intrebari si raportari probleme.� Formular pentru a descarca cea mai recenta versiune a DXDKEY sau fisiere necesare

rularii programului DXDKEY.

De asemnea compania ce reperezinta AVO ar putea oferii raspunsuri la anumite probleme.

DACOM IMPEX S.R.L. V4.0

69

Page 70: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

DACOM IMPEX S.R.L. V4.0

70

Page 71: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

SECTIUNEA IIISECTIUNEA III

APLICATII SI EXEMPLE APLICATII SI EXEMPLE

DACOM IMPEX S.R.L. V4.0

71

Page 72: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Capitolul 1 Capitolul 1

INTRODUCEREINTRODUCERE

PRINCIPII DE OPERAREPRINCIPII DE OPERAREPRINCIPII DE OPERAREPRINCIPII DE OPERARE

Marea majoritate a structurilor de izolatie pot fi destul de bine aproximate cu o reteacapacitiva cu doua sau trei terminale ca in Fig. 1. Capacitatea directa dintre terminalele Hsi L este reprezentata de capacitatea CHL iar capacitatile dintre fiecare terminal si masasunt reprezentate de CHG si CLG. In cazul capacitatilor cu doua terminale, terminalui L esteconectat la masa.Un exemplu de capacitate cu doua terminale este un izolator de transformator. Conductorulcentral este un terminal iar flansa de prindere (centura) -pusa la masa- al doilea terminal.Un exemplu de capacitate cu trei terminale este tot un izolator ce are un colier cunductor(pentru masura). Conductorul central este un terminal, inelul este al doilea, iar flansa demontare este al treilea.Este posibil sa gasim in practica sisteme complexe care au patru sau mai multe terminale.O masurare directa a oricarei componente dintr-un sistem complex poate fi facuta cu acestset de test deoarece el are posibilitatea de a masura atat capacitati impamantate cat sineimpamantate. (montaj direct sau invers)Figura 2 arata schema simplificata a setului de test atunci cand se masoara in modul USTo capacitate cu trei terminale. Puntea de masura foloseste un transformator diferential decurent cu trei infasurari. Inductia in infasurarea Nx datorata curentului Ix ce trece princapacitatea testata CHL este echilibrata de inductia in infasurarea Ns, datorat curentului Isce trece prin capacitatea de referinta Cs. Aceeasi tensiune este aplicata celor douacapacitati de catre sursa de tensiune.Echilibrarea puntii se obtine pentru componenta capacitiva a curentului prin modificareaautomata a numarului de spire Ns si Nx. Dupa realizarea echilibrarii, valoarea capacitatiieste afisata.

Curentul ce trece prin punte are atat componenta capacitiva (defazata la 900) cat sicomponenta rezistiva -de pierderi, in timp ce capacitatea de referinta Cs este ideala (deci Iseste numai capacitiv). Ca atare un curent rezidual va aparea dupa echilibrareacapacitatilor. Acesta reprezinta componenta de pierderi dielectice in capacitatea CHL , curentce va fi de asemeni echilibrat automat pentru a afla Tan delta (DF), sau pierderile efectivein watt, marimi ce vor fi afisate pe LCD.

Figura 2 arata deasemenea cum se realizeaza pasivizarea (gardarea) in modul UST.Puntea va masura capacitatea CHL ce este desenata cu linie ingrosata. Toti curentii datorati

DACOM IMPEX S.R.L. V4.0

72

Page 73: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

capacitatilor distribuite, parazite interne sau externe, intre terminalul de inalta tensiune H siecran (in cazul acesta pamant) nu trec prin infasurarea Nx a puntii, ei vor afecta numai caincarcare sursa de putere. Acelasi lucru se poate spune si despre capacitatile parazite,distribuite de la terminalul L la ecran (masa).

In practica impedanta infasurarii Nx fiind foarte mica o capacitate parazita foarte mare (>2000pF) poate fi pusa in paralel peste ea, fara ca rezultatul masurarii sa fie afectatsimtitor.

Figura 1: Capacitati cu doua si trei terminale

DACOM IMPEX S.R.L. V4.0

73

Page 74: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 2: Schema simplificata a setului de masura in modul UST MEASURE READ

Figura 3 arata circuitul de masura si circuitul de gardare pentru modul GST GROUNDRED. In acest test terminalul L este pus la masa (pamant), si este o capacitate cu douaterminale. Puntea masoara cele doua capacitati aratate de linia ingrosata CHL+CHG . Toatecapacitatile distribuite intre terminalul CXH si ecran sunteaza sursa de alimentare, in timp cecapacitatile distribuite parazite, intre garda si masa sunteaza bratul Nx al puntii, si deciambele tipuri de capacitati parazite nu vor afecta rezultatele din acelasi motiv ca la metodaUST.

Figura 4 arata circuitul de masura si circuitul de gardare pentru modul GST GUARD RED.Puntea masoara capacitatea aratata cu linie ingrosata CHG. Toate capacitatile distribuiteinterne si externe parazite intre terminalul H si garda sunteaza sursa de alimentare, iarcapacitatile distribuite parazite, intre garda si masa sunt in paralel peste bratul Nx al puntiisi amandoua sunt excluse, pe baza acelorasi principii expuse la metodele anterioare, de lamasuratori.

DACOM IMPEX S.R.L. V4.0

74

Page 75: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 3: Circuit simplificat de masura in modul GST GROUND READ

Figura 4: Circuit simplificat de masura in modul GST GUARD READ

DACOM IMPEX S.R.L. V4.0

75

Page 76: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

RELATII INTRE CURENT, CAPACITATE SI TANGENTA DERELATII INTRE CURENT, CAPACITATE SI TANGENTA DERELATII INTRE CURENT, CAPACITATE SI TANGENTA DERELATII INTRE CURENT, CAPACITATE SI TANGENTA DEDELTADELTADELTADELTA

Intr-un sistem ideal de izolatii conectate la o sursa de tensiune alternativa curentul Ic sitensiunea sunt defazate la 900. In practica pe langa curentul capacitiv apare si un curentrezistiv, numit curent de pierderi Ir, in faza cu tensiunea ca in fig.5.

Figura 5: Diagrama vectoriala intr-un sistem de izolatiiCurentul in sistemul de izolatii ideal (fara pierderi) Ir=0 este un curent capacitiv pur defazatla 900 inaintea tensiunii (θ =0). In practica nici o izloatie nu este perfecta, avand si ocomponenta de pierderi, iar curentul total I este inaintea tensiunii cu o faza θ oarecare(θ<90). In sistemul european se foloseste unghiul de pierderi dielectrice δ unde δ=90°-θ.Pentru factor de pierderi scazut curentii Ic si I sunt de valori foarte apropiate in timp ce Ireste foarte mic.Factorul de putere (power factor, PF) este definit ca : PF = cos θ = sinδ= Ir / Iiar tangenta de delta, (dissipation factor, DF) este definit ca: DF = tgδ= Ir / IcAparatul prezentat este calibrat pentru citirea directa a capacitatii si a tangentei de delta inprocente cat si a factorului de putere.

Caracteristica importanta a unui condensator este raportul dintre rezistenta de pierderi sireactanta care este Tan delta (DF) ce este prezentata in diagrama vectoriala din fig. 6.

DACOM IMPEX S.R.L. V4.0

76

Page 77: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 6: Diagrama vectoriala pentru rezistenta si reactanta capacitiva

tg δ = R/Xc = R ϖC

Xc = 1/ ϖ C

Pentru cazurile in care unghiul delta este foarte mic sin δ este aproximativ egal cu tg δ. Deexemplu, pentru valori mai mici de 10% diferenta este mai mica de 0,5%, iar pentru valorimai mici de 20% diferenta este mai mica de 2% din citire.Valoarea curentului Ic este cam 99,5% din I. Pentru factor de putere (PF), sinδ de pana la10% si aproximativ 98% pentru PF de pana la 20%.Curentul capacitiv Ic la o tensiune si frecventa data se calculeaza dupa formula:

Ic = V ϖ C

Figura 7: Circuit echivalent pentru pierderi capacitive

In realitate un condensator are rezistenta de pierderi atat paralel cat si serie asa cum estearatat in Fig. 7. Frecventa tensiunii aplicate determina care dintre pierderi domina, de altfelpentru frecvente mici (50/60Hz) numai Rp -rezistenta de pierderi in paralel- este importantafiind singura masurata in dielectric. Pentru o frecventa oarecare orice pierderi pot fiexprimate in termeni de pierderi paralel sau serie cu precizie egala. Alegerea este oproblema de conveniente. Tangenta de delta pentru un circuit echivalent serie este defintaca:

tg δ = Rs ϖ Cs

Pentru a gasi marimile echivalente Cp si Rp legate de circuitul echivalent paralel se aplicaformulele din fig.8.

DACOM IMPEX S.R.L. V4.0

77

Page 78: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 8: Circuit echivalent serie - paralel

))(

11()11(

)(11

1tg

22

22

sss

ssp

ss

s

s

sp

pp

CRR

tgRR

CRC

tgCC

CR

ωδ

ωδ

ωδ

+=+=

+=

+=

⋅=

DACOM IMPEX S.R.L. V4.0

78

Page 79: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

SCHEME DE CONEXIUNI PENTRU MODURILE DE TESTSCHEME DE CONEXIUNI PENTRU MODURILE DE TESTSCHEME DE CONEXIUNI PENTRU MODURILE DE TESTSCHEME DE CONEXIUNI PENTRU MODURILE DE TESTUST/GSTUST/GSTUST/GSTUST/GST

In Fig 9 la 12 sunt prezentate conexiunile specifice intre setul de test si echipamentul testatpentru fiecare mod UST/GST selectat. Aceste desene arata care element capacitiv (plus tgdelta) este masurat pentru fiecare selectie UST/GST, precum si cum setul de testconecteaza automat terminalele de masura Red si Blue la masa, garda sau in circuitul depunte. Capacitatile masurate sunt desenate cu linii ingrosate.Masurarea se face intotdeauna intre terminalul CXH (negru) de inalta tensiune si terminaluldin coloana MASURA ca in tabelul de mai jos. De remarcat ca atunci cand sunt trecutedoua terminale in aceeasi coloana ele indeplinesc aceeasi functie simultan (gardate,masurate, puse la pamant, etc.). Pentru modul de test GST masurarea se face deasemenea intre inalta tensiune si masa. (pozitia 4).

USTGROUNDS MEASURES TEST MODE POSITION

(Cat. No. 670025, 670065, 670070 & 672000) RED & BLUE 1

BLUE RED 3RED BLUE 2

GST GROUNDGROUNDS

RED & BLUE 4 GST

GUARDS GROUNDSRED & BLUE 5

RED BLUE 7BLUE RED 6

DACOM IMPEX S.R.L. V4.0

79

Page 80: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 9: Conexiuni pentru transformatoare trifazate

DACOM IMPEX S.R.L. V4.0

80

Page 81: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 10: Conexiuni in mod UST pentru echipamente echivalate cu capacitatati cu 4 terminale

DACOM IMPEX S.R.L. V4.0

81

Page 82: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 11: Conexiuni in mod GST pentru echipamente echivalate cu capacitatati cu 4terminale

DACOM IMPEX S.R.L. V4.0

82

Page 83: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 12: Conexiuni in mod GST gardat (guard) pentru echipamente echivalate cu capacitatati cu 4 terminale

DACOM IMPEX S.R.L. V4.0

83

Page 84: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Capitolul 2Capitolul 2

INTERPRETAREA REZULTATELORINTERPRETAREA REZULTATELOR

SEMNIFICATIA CAPACITATII SI A TANGENTEI DE DELTASEMNIFICATIA CAPACITATII SI A TANGENTEI DE DELTASEMNIFICATIA CAPACITATII SI A TANGENTEI DE DELTASEMNIFICATIA CAPACITATII SI A TANGENTEI DE DELTA

Un procentaj ridicat al caderilor echipamentelor electrice se datoreaza deteriorarii stariiizolatiilor. Multe dintre acestea pot fi prevazute prin aplicarea regulata a unor teste simple siprin aplicarea metodelor de mentenanta rezultate din aceste teste. Un sistem de izolatii sauechipamente nu trebuie scoase din uz pana cand nu au fost izolate complet, curatate sauservice-ate corespunzator iar masuratorile compensate cu temperatura. Interpretareacorecta a testelor de capacitate si tangenta de delta in general cer cunostinte despreconstructia echipamentelor si caracteristiciile tipului particular de izolatii folosite.

Schimbari in valoarea normala a capacitatii unei izolatii indica conditii anormale ca: stratsuperficial umezit, scurtcircuit, sau circuite intrerupte in lantul de capacitati. In generalmodificarea capacitatii indica deteriorari grave ale sistemului de izolatii. Masuratorile de tandelta (D.F.) indica urmatoarele conditii ale izolatiilor pentru un larg spectru de echipamente:• Deteriorari chimice datorate inbatranirii si temperaturii, incluzand cazurile de acuta

deteriorare a izolatiei datorate incalzirilor locale.• Umiditate, depuneri de carbon, ulei prost, praf sau alte substante chimice. • Curent de scurgere prin fisuri sau suprafata• Ionizare

Interpretarea masuratorilor este bazata uzual pe experienta, recomandarile producatoruluisi prin observarea urmatoarelor diferente:

• Intre masuratori succesive ale aceluiasi echipament la anumite intervale de timp.

• Intre masuratori ale aceluiasi tip de echipament sau parti identice ale acestuia, testate inaceleasi conditii in intervale de timp aproximativ egale, a mai multor transformatoareidentice sau a infasurarilor unui transformator trifazat testate separat.

• Intre masuratori efectuate la diferite tensiuni de test pe acelasi echipament sau parti aleacestuia. Cresterea pantei curbei tangenta de delta/ tensiune in mod excesiv este oindicatie de incepere a ionizarii la acea tensiune.

Cresterea tangentei de delta peste valorile tipice poate indica conditii ca cele prezentatemai sus, ce pot fi locale sau generalizate in intreg echipamentul. Daca tangenta de delta

DACOM IMPEX S.R.L. V3.0

84

Page 85: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

variaza seminificativ cu scaderea tensiunii pentru o anumita tensiune sub care esteaproximativ constanta atunci este indicata ionizarea. Daca aceasta valoare distincta de tensiune este sub tensiunea de operare atunci procesulde ionizare se va extinde in timp, concomitent cu deteriorarile corespunzatore. O anumitacrestere a capacitatii (crestere a curentului de incarcare) se va putea observa deasemenea, la aceasta valoare de tensiune, ca urmare a scurtcircuitarii numeroaselor goluride catre fenomenul de ionizare. O crestere a tangentei de delta acompaniata de o crestere notabila in capacitate, uzualindica umiditate excesiva in izolatii. Cresterea numai a tangentei de delta poate fi cauzatade deteriorare termica sau contaminare cu alt ceva decat apa.Pentru izolatori, suprafete terminale, chiar daca sunt curate si uscate valorile masurate nuse refera in mod necesar la volum. Orice curent de scurgere pe suprafata exterioara sepoate insuma cu pierderile intrinseci ale izolatiei, putand fi o falsa informatie a conditieiizolatiei.

DACOM IMPEX S.R.L. V3.0

85

Page 86: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

TANGENTA DE DELTA PENTRU CATEVA TIPURI DETANGENTA DE DELTA PENTRU CATEVA TIPURI DETANGENTA DE DELTA PENTRU CATEVA TIPURI DETANGENTA DE DELTA PENTRU CATEVA TIPURI DEIZOLATIIIZOLATIIIZOLATIIIZOLATII

Valorile tangentei de delta pentru diverse echipamente sunt date in tabelul de mai jos.Aceste valori pot fi utile in aprecierea bruta a rezultatelor practice, oricum ca limitesuperioare nu vor fi folosite in mod absolut inplicand scoaterea din uz a echipamentelor.Tan delta are un avantaj direct fata de masurarea pierderilor in Wat pentru ca esteindependenta de volumul masuratorilor sau grosimea izolatiei. Pierderile dielectrice in wattvor creste odata cu crestera volumului (marimii) izloatiei testate.

Tabelul 1: Tangenta de delta tipice pentru cateva izolatii

Type Apparatus % DF (PF) at20°C

Transformatoare cu ulei : Noi, Inalta tensiune (115 kV saumai mare)15 ani vechime ,inalta tensiuneJoasa tensiune, distributie

0.25 to 1.0

0.75 to 1.51.5 to 5.0

Oil circuit breakers (intrerupatoare cu ulei) 0.5 to 2.0Oil-paper cables, “solid” (up to 27.6 kV) new condition(cabluri cu hartie impregnata cu ulei)

0.5 to 1.5

Oil-paper cables, high-voltage oil-filled or pressurized (cabluri cu hirtie impregnata umplute cu ulei presurizat)

0.2 to 0.5

Rotating machine stator windings, 2.3 to 13.8 kV (masinirotative-infasurari statorice)

2.0 to 8.0

Capacitors (discharge resistor out of circuit) (Capacitati) 0.2 to 0.5Bushings: Solid or dry (Izolatori)Compound-filled, up to 15 kVCompound-filled, 15 to 46 kVOil-filled, below 110 kVOil-filled, above 110 kV and condenser type

3.0 to 10.05.0 to 10.02.0 to 5.01.5 to 4.00.3 to 3.0

DACOM IMPEX S.R.L. V3.0

86

Page 87: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Permitivitatea si tangenta de delta % pentru materiale izolante tipice

Valorile tipice ale pemitivitati dielectrice (constanta dielectrica) si tangenta de delta la 50/60Hz a catorva materiale izolatoare (incluzand apa si gheata) sunt date in tabelul 2.

Tabelul 2: Pemitivitatea materialelor izolatoare tipice

Material k % DF (PF)at 20°C

Acetal resin (Delrin*) 3.7 0.5Air 1.0 0.0Askarels 4.2 0.4Kraft paper, dry 2.2 0.6Oil, transformer 2.2 0.02Polyamide (Nomex*) 2.5 1.0Polyester film (Mylar*) 3.0 0.3Polyethylene 2.3 0.05Polyamide film (Kapton*) 3.5 0.3Polypropylene 2.2 0.05Porcelain -potelan 7.0 2.0Rubber - cauciuc 3.6 4.0Silicone liquid 2.7 0.01Varnished cambric, dry -email, uscat 4.4 1.0Water** - apa 80 100Ice** -gheata 88 1.0 (0°C)

* Dupont-marca inregistrata** Testele pentru apa nu se fac la temperatura de inghetare a apei din cauza raportului de100 dintre tangenta de delta a apei si tangenta de delta a ghetei.

DACOM IMPEX S.R.L. V3.0

87

Page 88: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

SEMNIFICATIA TEMPERATURIISEMNIFICATIA TEMPERATURIISEMNIFICATIA TEMPERATURIISEMNIFICATIA TEMPERATURII

Majoritatea masuratorilor trebuie interpretate tinand cont de temperatura echipamentelortestate. Pierderile dielectrice pentru majoritatea izolatorilor cresc odata cu temperatura. In multecazuri caderea izolatiilor se datoreaza efectelor cumulate ale temperaturii, adica crestereatemperaturii determina crestera pierderilor care la randul lar implica o crestere atemperaturii, s.a.m.d.

Este important sa se determine caracteristica tangenta de delta/temperaturacorespunzatoare izolatiei echipamentului testat, altfel toate testele efectuate pe un acelasiechipament trebuie efectuate pe cat posibil la o aceeasi temperatura. Pentrutransformatoare si echipamente similare masuratorile efectuate in timpul racirii (dupaincalzirea datorata functionarii) poate asigura factorul de corectie al temperaturii. Pentruintrerupatoare sau alte echipamente pentru care apare o incalzire redusa in functionare,masurarile in scopul determinarii factorului de corectie a tangentei de delta functie detemperatura pot fi facute la diferite temperaturi, dar constante conditii de mediu.

Pentru a compara valoarea masurarilor de tangenta de delta pe aceleasi echipamente sautipuri similare la diferite temperaturi este necesar sa convertim valorile, i.e. aplicarea unuifactor de corectie, corespunzator valorii tangentei de delta la temperatura standard, uzual20°C. Factorii de corectie corespunzatori pentru a transforma valoarea tangentei de deltala +20° ar trebui furnizati in principiu de catre producatorul echipamentului.Temperatura de test pentru echipamente ca izolatii, intrerupatoare in aer sau gaz,descarcatori este presupusa in mod normal a fi aceea a mediului ambiant. Pentruintrerupatoare cu ulei, transformatoare racite cu ulei temperatura la care se face testul esteconsiderata aceea a uleiului. Pentru izolatori a caror parte inferioara este cufundata in ulei,temperatura la care se face testul este considerata undeva intre temperatura mediuluiambiant si temperatura uleiului.In practica temperatura de test pentru izolatori instalati in ulei, intrerupatoare sitransformatoare racite cu ulei, este considerata aceea a mediului ambiant daca acestea aufost scoase din serviciu de cel putin 12h. Pentru transformatoare scoase din serviciu chiarinaintea testului temperatura uleiului este de obicei mai ridicata decat a mediului ambiant.Temperatura de test pentru izolatorii aferenti transformatoarelor in acest caz poate ficonsiderata ca media dintre temperatura uleiului si a aerului.

Orice schimbare brusca in temperatura mediului ambiant va creste eroarea masuratorilorpentru ca temperatura echipamentului se va modifica cu intarziere. Capacitatea izolatoriloruscati este mai putin afectata de temperatura, oricum in cazul umezirii izolatiei exista ousoara tendinta de crestere a capacitatii cu temperatura.

Caracteristica tan delta-temperatura, la fel ca masurarile de tangenta de delta la otemperatura data se poate schimba odata cu deteriorarea sau distrugerea izolatiei.Aceasta sugereaza ca orice astfel de modificare poate fi utila in optinerea informatiilordespre deteriorarea izolatiei.O atentie sporita trebuie acordata pentru masuratorile efectuate la temperaturi scazute,

DACOM IMPEX S.R.L. V3.0

88

Page 89: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

apropiate de temperatura de inghet a apei. O fisura intr-un izolator, de exemplu, este usor detectata daca contine o pelicula de apaconducatoare. Daca apa ingheata devine neconducatoare si astfel defectul nu mai esterelevat de masuratoare, din cauza rezistivitatii volumetrice de aproximativ 100 de ori maimare a ghetei decat a apei. De aceea testele pentru determinarea prezentei umezelii inizolatori solizi presupusi a fi uscati nu trebuie facuta la 0°C. Umezeala in ulei sau in izolatorisolizi impregnati cu ulei, ce poate fi detectata prin masurari de tangenta de delta latemperatura mai ridicate de 0°C, poate fi detectata fara discontinuitate si la temperatura deinghet a apei.Suprafata izolatorilor expusa conditiilor meteo ale mediului ambiant poate fi de asemeniafectata de temperatura. Temperatura suprafetei echipamentelor energetice trebuie sa fiemai ridicata si niciodata mai scazuta decat a mediului ambiant pentru a preveni efectelecondensarii pe suprafetele expuse.

SEMNIFICATIA UMIDITATIISEMNIFICATIA UMIDITATIISEMNIFICATIA UMIDITATIISEMNIFICATIA UMIDITATII

Suprafetele expuse ale izolatorilor pot, in conditii de umiditate neprielnice, sa acumulezeumezeala care poate afecta in mod semnificativ curentii de scurgere pe suprafata si inconsecinta rezultatele testelor de tangenta de delta. Aceasta este adevarata pentruizolatorii de portelan daca temperatura de la suprafata este mai joasa decat temperaturamediului ambiant (mai jos ca punctul de roua), pentru ca umezeala va condensa pesuprafata izolatorului. Erori serioase pot rezulta chiar daca umiditatea relativa este sub50% atunci cand umezeala condenseaza pe suprafata izolatorului de portelan ce esteacoperit cu diverse depuneri de substante chimice.

Este important de remarcat ca un strat foarte fin invizibil de umezeala se formeaza lasuprafata materialelor izolatoare de portelan smaltuit care are au o absortie de volumneglijabila. Echilibrul dupa o brusca schimbare a umiditatii relative este atins uzual inperioade de timp de ordinul minutelor. Aceasta de cele mai multe ori exclude filmul fin deumezeala ce rezulta in urma ploii, cetii, etc.Erorile datorate curentilor de scurgere de suprafata pot fi minimizate daca testele detangenta de delta sunt efectuate in conditii de vreme insorita iar umiditatea relativa nudepaseste 80%. In general, cele mai bune rezultate sunt obtinute, daca testele suntefectuate in jurul amiezii. Atentie trebuie acordata probabilitatii ca umezeala sa existedatorita condensarii, ploii, cetii, etc inaintea efectuarii testelor.

DACOM IMPEX S.R.L. V3.0

89

Page 90: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

SCURGERILE DE SUPRAFATASCURGERILE DE SUPRAFATASCURGERILE DE SUPRAFATASCURGERILE DE SUPRAFATA Orice curent de scurgere pe suprafata echipamentului testat va fi adaugat pierderilor devolum existente ale izolatiei, si pot determina o gresita impresie asupra stariiechipamentului. Chiar si un izolator de portelan, cu domeniul de tensiune mult mai ridicatdecat al testului efectuat, in cazul contaminarii suprafetei acumuleaza erori importante. Deaceea suprafetele izolatorilor este bine a fi curatate si uscate inaintea efectuarii testelor.

Ar fi bine de notat ca rezistivitatea de suprafata intre doua puncte fata de umiditatearelativa, pentru suprafete necontaminate ale izolatorilor de portelan, are o descrestere de odecada pentru o crestere de 15% a umiditatii relative si viceversa.

Pentru izolatori prevazuti cu inel pentru masurarea tangentei de delta sau a capacitatiiefectul curentului de scurgere de suprafata poate fi eliminat prin test de tip UST.Atunci cand se testeaza izolatori ce nu sunt prevazuti cu borne de masura a tan delta, inconditii de umiditate ridicata, numeroase companii au raportat ca efectul curentilor descurgere de suprafata poate fi substantial micsorat prin curatarea si uscarea suprafeteiizolatorului de portelan si aplicarea unui strat foarte subtire de unsoare izolatoare (DowCorning # 4 sau echivalenta) pe intreaga suprafata. Pentru teste cu inel de tangenta dedelta cald, unsoarea este in general aplicata numai pe suprafata de portelan pe care ineluleste asezat si o “fusta" deasupra si una dedesuptul acestuia.Cind se testeaza izolatori fara borna de masura sau alti izolatori in conditii de vremenefavorabila, citirile de tangenta de delta pot fi uneori instabile si pot varia usor intr-operioada scurta de timp. Variatiile sunt cauzate de astfel de factori ca cei mai susmentionati, expunerii suprafetelor la soare sau umbra , variatii in viteza vantului, schimbaritreptate in temperatura sau umiditatea mediului. Teste efectuate pe acelasi izolator potavea valori distincte de tangenta de delta dimineata sau dupa amiaza.

INTERFERENTELE ELECTROSTATICEINTERFERENTELE ELECTROSTATICEINTERFERENTELE ELECTROSTATICEINTERFERENTELE ELECTROSTATICE

Atunci cand testele sunt efectuate in statii aflate sub tensiune, citirile vor fi influentate decurenti indusi de campul electrostatic, prin cuplare capacitava intre liniile aflate subtensiune si liniile aferente echipamentului testat. In laborator sau statii de medie tensiuneefectele campului perturbator pot fi anulate prin efectuarea testului cu tensiune cupolaritate normala si inversa. In statiile de inalta tensiune efectele interferentelorelectrostatice pot fi anulate prin utilizarea circuitelor de suprimare a interferentelor.Schimbarea polaritatii tensiunii aplicate normal si invers trebuie mentinuta pentru a anulaorice curent rezidual de interferenta.Pentru a evalua efectele interferentelor elecrostatice in cadrul masuratorilor, ar fi necesarsa deconectam echipamentul testat de la intreruptorul de serviciu precum si liniile de lucru.Experienta in a face masuratori va stabili locul concret de deconectare a liniilor si aechipamentului testat. Elementele deconectate, linii, intrerupatoare, etc vor fi bineimpamantate pentru a minimiza cuplajul electrostatic catre echipament. Dificultatile intalniteatunci cand testam in prezenta interferentelor depind nu numai de marimea campuluiperturbator, ci si de capacitatea si a tangentei de delta a echipamentului. Conditii climatice

DACOM IMPEX S.R.L. V3.0

90

Page 91: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

nefavorabile ca: umiditate relativa ridicata, ceata, cer schimbator, vant cu viteza mare, vacreste severitatea si variabilitatea campului de interferenta. Cu cat sunt mai mici valorilecapacitatii si tangentei de delta asteptate a fi masurate, cu atat sunt mai mari dificultatile,cu posibile scaderi ale rezolutiei masuratorilor. Este posibil ca tangenta de delta negativesa se obtina in astfel de cazuri, si este necesara observarea semnului pentru fiecare citire.In special este de asteptat, in cazul masuratorilor in cazul montajului GST in statiile de 23-550kV, pentru echipamente ce au capacitatea echivalenta mai mica de 100pF, sa aparaastfel de probleme. Aceste dificultati pot fi micsorate prin:

• Utilizarea tensiunii maxime de test posibile pentru echipamentul testat.

• Deconectarea si impamantarea a cat mai multor linii pe cat posibil.

• Efectuand masuratorile in conditii de vreme frumoasa, cer senin, umiditate relativa maimica de 80%, viteza vantului scazuta si temperatura la suprafata echipamentului testatla temperatura mediului ambiant.

Masuratori efectuate in montaj UST sunt mai putin susceptibile la interferente decat cele inmontaj GST. In configuratie UST curentii indusi paraziti, datorati cuplarii capacitive, trecdirect catre pamant, dupa ce au trecut prin infasurarea de inalta a transformatorului dealimentare, in timp ce pentru configuratia GST dupa ce au trecut prin infasurarea de inaltaa transformatorului de alimentare, trec printr-unul din bratele puntii de masura si apoi sprepamant. Nu este in general recunoscut, ca atunci cand se efectueaza masuratori in configuratieGST, in vecinatatea unor echipamente aflate sub tensiune, apar si alte forme deinterferente ce pot produce modificari ale tan delta. Aceste perturbatii pot fi de tip corona siapar la terminalele echipamentelor de inalta tensiune, nu ca urmare a aplicarii tensiunii detest ci a campului intens dintre echipamentul testat si cele invecinate aflate sub tensiune.Pierderile datorate efectului corona se aduna cu pierderile normale determinand crestereavalorii tangentei de delta. Atat timp cat acest tip de interferente determina pierderi legate deechipamentul testat in conditii de amplasare particulare, nu pot fi eliminate din masuratori sinu pot fi considerate ca erori de masurare.Daca setul de test este alimentat de la un generator portabil, la efectuarea testelor in statiienergizate, citirile pot fluctua intr-un domeniu larg. Aceasta rezulta din nesincronizareadintre frecventa de lucru a generatorului de alimentare si frecventa campului electrostaticperturbator. Daca nu este posibila sincronizarea frecventei celor doua surse , deconectati siimpamantati cat mai multe din echipamentele apropiate, ceea ce va duce la reducereainterferentelor parazite si tot odata fluctuatiile de citire.

DACOM IMPEX S.R.L. V3.0

91

Page 92: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

TANGENTA DE DELTA NEGATIVATANGENTA DE DELTA NEGATIVATANGENTA DE DELTA NEGATIVATANGENTA DE DELTA NEGATIVA

In cazuri izolate, valori negative pentru tangenta de delta sunt intalnite la masuratorileechipamentelor cu valori mici ale capacitatilor. Aceste situatii apar cel mai des inconfiguratii UST si GST la testele echipamentelor ce au capacitati de cateva sute de pFsau mai putin. Echipamente cu izolatori de portelan, intrerupatoare, descarcatoare intra inaceasta categorie.Se crede ca fenomenul aparitiei valorilor negative ale tangentei de delta este cauzat de oretea in "T" complexa, de capacitati si rezistente existenta in cadrul echipamentului.Curentii ce provoaca erorile pot circula intre circuitul de masura, de exemplu si terminalefantoma multiple, sau terminalul de ecranare aparut in circultul de masura. Se presupunedeasemenea ca valorile negative ale tan delta pot fi produse de curentii paraziti ce curg inreteaua in T ca rezultat al cuplajului spatial, urmare a campului de interferenta. Conditiile in care apare acest fenomen sunt determinate de ecranarea imperfecta aelectrodului de masura sau cand echipamentul insusi este defect. Erorile sunt accentuatedaca testele sunt influentate de campuri de interferenta puternice sau in conditiinefavorabile, in special in conditii de umiditate relativa crescuta.

Apare cu nefiind o cale clara de a sti cand o eroare este semnificativa sau ce metode seaplica pentru a o elimina. Cel mai bun sfat este de a efectua masuratori numai in conditiiambientale favorabile, in special umiditate relativa scazuta, in locurile sau echipamentelece se stiu cu astfel de probleme. Asigurati-va ca suprafetele izolatorilor sunt curate siuscate pentru a micsora efectele curentilor de suprafata. Eliminati toate elementele ce arputea influenta masuratorile (terminale nefolosite, conductori, franghi de nailon, etc.)

DACOM IMPEX S.R.L. V3.0

92

Page 93: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Capitolul 3Capitolul 3

TIPURI DE ECHIPAMENTETIPURI DE ECHIPAMENTE

TRANSFORMATOARETRANSFORMATOARETRANSFORMATOARETRANSFORMATOARE

In cele ce urmeaza se vor prezenta modalitatea de utilizare si configuratii de teste indicatela masuratorile efectuate cu setul de test automat.Tensiunile de test pentru fiecare infasurare testata vor fi in concordanta cu tensiunilenominale. Daca sunt implicati in test izolatori de nul, valorile nominale prescrise se vorrespecta cu strictete. Masuratorile se vor face intre fiecare infasurare (combinatii deinfasurari) cu toate celelalte infasurari puse la pamant, la cuva, in montaj UST. Masuratorise vor face intre fiecare infasurare (sau sistem de infasurari trifazate) si pamant, cu toatecelelalte infasurari gardate, in configuratie GST. Pentru transformatoare cu doua infasurarimasuratori intre fiecare infasurare si pamant, cu infasurarea ramasa gardata configuratieGST. Pentru transformatoare cu trei infasurari, masuratori intre fiecare infasurare si pamant, cu oinfasurare pasivizata-gardata (guarded) si cea de a doua infasurare ramasa pusa la masa,configuratie GST cu gardare. Aceste teste sunt utile pentru a testa izolatorii dintreinfasurari. O masuratoare finala se va face intre toate infasurarile conectate inpreuna sicuva ce este impamantata. Este de dorit sa se testeze si esantioane de ulei.

Figura 13 arata un montaj tipic pentru un transformator cu 2 infasurari iar tabelul 3subliniaza conexiunile specifice intre Setul Automat de Test si transformator cu 2 infasuraripentru fiecare selectie UST, GST ale butoanelor de operare.Tabelul 4 evidentiaza conexiunile specifice pentru transformatoare cu 3 infasurari. De notatca fiecare infasurare trebuie scurtcircuitata la terminalele izolatorilor.Se recomanda efectuarea calculelor de verificare a masuratorilor indicate in tabelele 3 si 4,pentru a valida toate testele. Valorile calculate de verificare vor trebui sa corespundavalorilor masurate in limite rezonabile.Cresteri ale valorilor tan delta, in comparatie cu valori masurate anterior sau valorimasurate pe echipamente identice in conditii identice, pot indica cateva conditii generaleale starii echipamentului, ca spre exemplu deteriorarea uleiului. O crestere in valoare atangentei de delta si a capacitatii simultan poate indica faptul ca uleiul contine apa. Dupace lichidul izolator este filtrat sau tratat corespunzator, masuratori repetate asuprainfasurarilor si a lichidului izolator vor indica restabilirea starii initiale a echipamentului.

Oxidarea uleiului si implicit depunerile rezultate au un efect marcant asupra valoriitangentei de delta a infasurarii transformatoarelor. Dupa filtrarea (centrifugarea) uleiuluimasurarea tangentei de delta indica succesul operatiei de inlaturare a depunerilor.

DACOM IMPEX S.R.L. V3.0

93

Page 94: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Masuratori pe infasurari individuale identice pot varia datorita diferentelor dintre materialeleizolatoare folosite si datorita montarii. Oricum diferente mari indica deteriorareaechipamentului. Masuratori in combinatii diferite pe infasurari pot indica sau localiza defectul. De exempludaca valorile tangentei de delta intre doua infasurari sunt ridicate si valoarea fiecareiinfasurari si pamint, cu infasurarea ramasa pasivizata (gardata), sunt normale, atuncidefectul este situat in cilindrul izolator.Izolatorii aflati in stare proasta, pot avea propriile lor pierderi mascate de pierderile normalein infasurarea transformatorului si deci teste separate vor trebui efectuate asupra lor.Curbe de corectie cu temperatura pentru fiecare tip de transformator trebuiesc stabilite infabrica sau teren si trebuiesc utilizate pentru a corecta valorile masurate, pentru a obtinerezultate la o temperatura de referinta, uzual 20°C.

DACOM IMPEX S.R.L. V3.0

94

Page 95: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 13: Transformatoare cu doua infasurari

DACOM IMPEX S.R.L. V3.0

95

Page 96: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Tabelul 3: Conexiuni transformatoare cu doua infasurari

Conexiuni interne borne masuraConexiuni la

transformator

TestNo.

InsulationTested

Mod Test Masurat Impamantat Gardat BlackNegru

RedRosu

BlueAlbastru Obs

1 CHG+ CHL

GSTGND

Red & BlueH L L Grounded

2 CHG GSTRed &Blue H L L Guarded

3 CHL UST Red Blue H L

4 CHL Test 1 minus Test 2 Calculverificare

5 CLG + CHL

GSTGND

Red & BlueL H H Grounded

6 CLG GSTRed &Blue L H H Guarded

7 CHL UST Red Blue L H

8 CHL Test 5 minus Test 6 Calculverificare

9101112

Circuit echivalent H = High-voltage winding - inf. de inalta tensiuneL = Low-voltage winding- inf. de joasa tensiuneG = Ground -pamantObs: Scurtcircuitati fiecare infasurare

Verificare masuratorilor (Calculate) Capacitance Watt C4 = C1 - C2 W4 = W1 - W2

C8 = C5 - C6 W8 = W5 - W6

Obs: Indicii sunt numarul testului

DACOM IMPEX S.R.L. V3.0

96

Page 97: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Tabela 4: Conexiuni transformatoare cu trei infasurari.

Conexiuni interne borne masuraConexiuni la

transformator

TestNo.

InsulationTested Mod

TestMasurat Impamantat Gardat Black

Negru Red

RosuBlue

Albastru Obs

1 CHG+ CHL GST Red Blue H L TL GroundedT Guarded

2 CHG GSTRed &Blue H L T L & T

Guarded

3 CHL UST Red Blue H L T T Grounded

4 CHL Test 1 minus Test 2 Calculverificare

5 CLG + CLT GST Red Blue L T HT GroundedH Guarded

6 CLG GSTRed &Bluse L T H T & H

Guarded

7 CLT UST Red Blue L T H H Grounded

8 CLT Test 5 minus Test 6 Calculverificare

9 CTG + CHT GST Red Blue T H LH GroundedL Guarded

10 CTG GSTRed &Blue T H L H & L

Guarded

11 CHT UST Red Blue T H L L Grounded

12 CHT Test 9 minus Test 10 Calculverificare

Circuit EchivalentH = High-voltage winding(Infasurare de inalta tensiune)L = Low-voltage winding(Infasurare de joasa tensiune)T = Tertiary winding (Infasurare tertiara) G = Ground (Pamant)Nota: Scurtcircuitati fiecare infasurare

Verificarea masuratorilor (Calculat) Capacitance Watts C4 = C1 - C2 W4 = W1 - W2

C8 = C5 - C6 W8 = W5 - W6 C12 = C9 - C10 W12 = W9 - W10

Obs: Indicii sunt numarul testului.

DACOM IMPEX S.R.L. V3.0

97

Page 98: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Tabelele 5: Curent de magnetizare -Conexiuni

Transformator monofazatMasurari Conexiuni la infasurariSimbol terminal

Black Red Ground

H1-H2H2-H1

H1H2

H2H1

Transformator trifazat conexiune stea Masurari Conexiuni la infasurariSimbol terminal

Black Red Ground

H1-H0H2-H0H3-H0

H1H2H3

H0H0H0

Transformator trifazat conexiune triunghi Masurari Conexiuni la infasurariSimbol terminal

Black Red Ground

H1-H2H2-H3H3-H1

H1H2H3

H2H3H1

H3H1Η2

DACOM IMPEX S.R.L. V3.0

98

Page 99: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

INTRERUPATOAREINTRERUPATOAREINTRERUPATOAREINTRERUPATOARE

Cei mai importanti izolatori utilizati in constructia intrerupatoarelor din statii sunt izolatoriipropriuzisi, diverse elemente de ghidare, etc, iar in cazul celor cu ulei, uleiul. Masuratoritrebuiesc facute pentru fiecare izolator terminal si cuva cu intreruptorul deschis, si pentrufiecare faza si cuva cu intreruptorul inchis. Cand unul dintre izolatorii de pe o faza estetestat, celalalt izolator terminal al respectivei faze trebuie gardat. Este de asemenea dedorit sa se testeze esantioane de lichid izolator.

Termenul specific, index de pierderi al cuvei, s-a dezvoltat pentru a ajuta in evaluarearezultatelor in testele intrerupatoarelor deschise sau inchise. Este definit pentru fiecare fazaca diferenta valorilor masurate in circuit deschis si inchis, valoarea fiind data in watt. Pentrua obtine valoarea circuitului deschis, valorile individuale masurate pe cei doi izolatoriterminali se sumeaza. Indexul de pierderi al cuvei poate avea valori in domeniul negativ sipozitiv, ceea ce poate da o indicatie asupra surselor posibile ale problemelor. Indecsipozitivi apar atunci cand valorile masurate in circuitul inchis sunt mai mari ca cele in circuitdeschis. In consecinta indecsi negativi apar atunci cand valorile masurate in circuit inchissunt mai mici decat cele in circuit deschis. Rezultatele testelor se inregistreaza in termenide tensiune echivalenta de 2,5kV. Pentru a se obtine valori in wat ale indexului de pierderidin masurari de capacitate si tangenta de delta se folosesc formule de conversie. Sistemulautomat de test ofera informatiile chiar in watt.

Tabelul 6, Intrerupatoare in SF6 Conexiuni de teste, subliniaza conexiunile specifice intresetul de test si intrerupator precum si secventa de masuratori ce trebuie efectuata. Comparatiile intre valorile indexulul de pierderi pentru echipamentul nou si instalat sivalorile actuale sunt foarte importante si permit prevenirea posibilelor erori ce ar condamnagratuit un astfel de echipament.

Pierderile pentru intrerupatoare in ulei sunt diferite pentru circuitul deschis si inchis, pentruca tensiunea (campul) este distribuit diferit pe izolatoarele componente. Tabelul 7 si 8rezuma ce ar putea fi defect bazat pe polaritatea indexului de pierderi. Odata suspectata oanumita sectiune, pe baza valorii indexului de pierderi, sectiunea respectiva trebuie izolatasi masurata separat.Intrerupatoarele in ulei sunt alcatuite din materiale diferite, fiecare avand propriul coeficentde temperatura. Din acest motiv este dificil de a se corecta indexul functie de otemperatura standard. In consecinta este de dorit masurarea la temperaturi aproximativegale si in aceeasi perioada a anului.Intrerupatoarele in aer sau gaz sunt asa diferite constructiv incat cele mai utile suntinstructiunile specifice si interpretarile particulare. Oricum in tabelul 9 sunt prezentateconexiunile necesare si secventa de masuratori realizate la intrerupatoarele GeneralElectric tip ATB Air-Blast Circuit Breaker. Tabelul 10 subliniaza secventa normala demasuratori realizate pe un intreruptor cu trei coloane.

DACOM IMPEX S.R.L. V3.0

99

Page 100: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Tabel 6: Conexiuni de test Intrerupator SF6 Dead Tank

Conexiuni interne borne masuraConexiuni laIntrerupator

TestNo.

CB IzolatieTestata

ModTest Measura Grounds Guards Black Red Blue Remarks

1 C1G

GSTGND

Red &Blue 1 Bushing 2

floating

2 C2G

GSTGND

Red &Blue 2 Bushing 1

floating

3 O C3G

GSTGND

Red &Blue 3 Bushing 4

floating

4PE C4G

GSTGND

Red &Blue 4 Bushing 3

floating

5N

C5G

GSTGND

Red &Blue 5 Bushing 6

floating

6 C6G

GSTGND

Red &Blue 6 Bushing 5

floating

7 O C12 UST Red Blue 1 2

8PE C34 UST Red Blue 3 4

9N

C56 UST Red Blue 5 6

10CL C1G +

C2G

GSTGND

Red &Blue 1 or 2

11OS C3G +

C4G

GSTGND

Red &Blue 3 or 4

12ED C5G +

C6G

GSTGND

Red &Blue 5 or 6

Schema G = Ground Izolatia testata 1 la 6 = Borne IzolatoriNotea No. in ENG column is bushing energized. Tests 1 through 6, 10, 11, and 12 all otherbushings must be floating.

DACOM IMPEX S.R.L. V3.0

100

Page 101: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Tabel 7: Inexul de pierderi al cuvei intrerupatoare cu ulei (Echivalent la 10 kV )Tank LossIndex Test Remarks Probable Problem

InsulationRating

<±0.16 W Normal results for bothopen CB tests

None Good

>+0.16 W Normal results for bothopen CB tests

1. Tank oil2. Tank liner3. Lift rod4. Auxiliary contactinsulation

Investigate

>-0.16 W High losses for bothopen CB tests

Closed CB test nearnormal

1. Cross guide assembly2. Isolated cross guide3. Contact assemblyinsulation4. Lift rod upper section(moisture contaminated)

Investigate

<±0.16 W Normal results for oneopen CB test Other has high losses

1. Bushing with high lossreading2. Arc interruption assembly

Investigate

<±0.16 W High losses for bothopen CB tests andclosed CB test

1. Bushings2. Arc interruption assembly3. Tank oil4. Tank liner5. Lift rod6. Auxiliary contactinsulation7. Cross guide assembly8. Isolated cross guide9. Contact assemblyinsulation

Investigate

DACOM IMPEX S.R.L. V4.0

101

Page 102: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Tabel 8: Inexul de pierderi al cuvei intrerupatoare cu ulei (Echivalent la 2,5 kV )Tank LossIndex Test Remarks Probable Problem

InsulationRating

<±10 mW Normal results for bothopen CB tests

None Good

>+10 mW Normal results for bothopen CB tests

1. Tank oil2. Tank liner3. Lift rod4. Auxiliary contactinsulation

Investigate

>-10 mW High losses for bothopen CB tests

Closed CB test nearnormal

1. Cross guide assembly2. Isolated cross guide3. Contact assemblyinsulation4. Lift rod upper section(moisture contaminated)

Investigate

<±10 mW Normal results for oneopen CB test Other has high losses

1. Bushing with high lossreading2. Arc interruption assembly

Investigate

<±10 mW High losses for bothopen CB tests andclosed CB test

1. Bushings2. Arc interruption assembly3. Tank oil4. Tank liner5. Lift rod6. Auxiliary contactinsulation7. Cross guide assembly8. Isolated cross guide9. Contact assemblyinsulation

Investigate

DACOM IMPEX S.R.L. V4.0

102

Page 103: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Table 9: Conexiuni testare Intrerupator General Electric camera de stingere in aer

Conexiuni interne borne masuraConexiuni laIntrerupator

TestNo. Insulation

Tested

TestMode Measures Grounds Guards Black Red Blue Remarks

1 C2 + B2 UST Red Blue D F A A Grounded

2 C1 + B1 + I1 UST Blue Red D F A F Grounded

3 C2 + B2 +C1 + B1 + I1

USTRed &Blue D F A

4 R (or R + I3) GSTRed &Blue D F A F & A Guarded

5 I2 + T * GSTRed

Blue A F DD GuardedF Grounded

• Test performed only on units with current transformer.

B1 & B2 Entrance bushingsC1 & C2 Grading capacitorsD Module live tankI1 Upper insulatorI2 Lower insulatorI3 Insulator for units without current transformerR Glass fiber air supply tube, open rods and wood tie rodsT Current transformer insulationI4 and I5 Protective glass fiber tube that encloses R tube is slit at “E” with metal guardring

Measurement Intercheck Capacitance: C1 = C3 - C2 Watts: W1 = W3 - W2

DACOM IMPEX S.R.L. V4.0

103

Page 104: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Table 10: Live Tank Circuit Breaker Test Connections (Typical Three-Column Support Per Phase)

Conexiuni interne borne masuraConexiuni laIntrerupator

TestNo.

InsulationTested φ

TestMode Measures Grounds Guards Black Red Blue

Obs

1 C1 UST Red Blue B A C C Grounded

2 C2 UST Blue Red B A C A Grounded

3 S1 GSTRed &Blue B A C A & C Guarded

4 C3 UST Red Blue D C E E Grounded

5 C4 UST Blue Red D C E C Grounded

6 S2 GSTRed &Blue D C E C & E Guarded

7 C5 UST Red Blue F E G G Grounded

8 C6 UST Blue Red F E G E Grounded

9 S3 GSTRed &Blue F E G E & G Guarded

101112

Schema

A, C, E & G Locul de conectare ai conductorilor de masura B, D, F Cuva activa a intrerupatoruluiC1 thru C6 Izolatori de intrare si capaitati de stingereL1, L2 Conexiuni intre coloanele de intreupatoare S1, S2, S3 Suportul intrerupatorului din coloana

Obs: Pentru a reduce efectele interferentelor electrostatice severe deconectati legaturile L1 siL2 pentru a intrerupe legaturile intre module. Toate terminalele si barele care nu intra incircuitul de masura trebuie inpamaintate.

DACOM IMPEX S.R.L. V4.0

104

Page 105: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

IZOLATORIIZOLATORIIZOLATORIIZOLATORI

Toti izolatorii moderni avand tensiunea nominala 23kV sau mai mare sunt prevazuti cuborna de masura care permite masurarea tangentei de delta fara a fi necesaradeconectarea, demontarea acestuia. Masuratorile se fac in montaj UST care permiteeliminarea influentelor infasurarilor transformatoarelor, etc.Efectul capacitatii distribuite intre terminalul izolatorului si pamant precum si efectulcurentului de scurgere de suprafata sunt de asemenea eliminate din masuratoare. Prinmetoda UST este masurat numai izolatorul si nu este afectat rezultatul masuratorilor deconditii exterioare.Figura 14 arata conexiunile de test dinte Setul de Test si izolator in montaj UST. Seconecteaza cablul de I.T. (negru) la terminalul central de intrare, iar firul de masura cuterminatie rosie la borna ( inelul de masura) al izolatorului. Inelul (in cazul celor prevazuti cuinel) este normal impamantat si este necesara scoaterea legaturii catre pamant a acestuia.Se va folosi modul de test UST.Testul UST se poate folosi si pentru izolatoarele care pot fi prevazute cu izolator al flansei.Metoda normala de a izola flansa de suport este de a folosi garnitura izolatoare intre flansasi suport si de a desface bolturile care in functionare normala impamanteaza flansa.Masuratorile sunt apoi identice ca cele de la izolatorii care au borna de tangenta de delta,cu exceptia conexiunii de joasa, firul rosu, care se conecteaza la flansa izolata.

DACOM IMPEX S.R.L. V4.0

105

Page 106: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Figura 14: Test UST pe izolatori de transformator

CHG, CHL, and C3 sunteaza sursa si deci nu au nici o influenta asupra masuratorilor.

C2 sunteaza infasurarea puntii si pana la valori de 5000 pF influenta lui este neglijabila.

DACOM IMPEX S.R.L. V4.0

106

Page 107: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

TESTUL CU INEL “CALD”TESTUL CU INEL “CALD”TESTUL CU INEL “CALD”TESTUL CU INEL “CALD”

Pierderile dielectrice prin diverse sectiuni ale izolatorilor sau terminale ale cablurilor izolatecu ulei pot fi investigate prin utilizarea unui inel ”cald”, test care genereaza aplicareatensiunii inalte local. Acest deziderat se realizeza prin utilizarea unei benzi conductoareaplicata strins peste portiunea izolatorului de portelan, uzual sub ’fusta' din virfulizolatorului, si aplicand I.T direct pe inelul conductor astfel realizat. Conductorul central alizolatorului este impamantat. Acest test asigura masurarea pierderilor in sectiunea situatamai jos de inel, si este foarte utila in determinarea golurilor din material sau penetrariiumezelii la izolatoarele ce pot fi supuse unui gradient de I.T. , gradient ce nu se obtine cutestele normale. Aceasta metoda este de asemenea utila la detectarea defectelor inizolatori de condensare si in verificarea nivelului de ulei a izolatorilor umpluti cu ulei, dupace un model de valori a fost ridicat. Daca valori anormale masuratorilor tangentei de deltasunt obtinute, testul se va repeta cu un inel ”cald" amplasat direct sub a doua “fusta”. Dacaeste necesar se va muta inelul mai jos pentru a determina cat de mult a patruns defectul.Metoda “inelului cald" se efectueaza in montaj GST GROUND, iar izolatorul se va demontadin structura echipamentului din care face parte. Inelul cald este realizat de regula dinbanda de cupru si trebuie infasurat foarte strans in jurul izolatorului, pentru un contact bun,spre a elimina efectul corona ce poate aparea intre suprafete.

DACOM IMPEX S.R.L. V4.0

107

Page 108: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

TESTUL BORNELOR DE TANGENTA DE DELTA SAUTESTUL BORNELOR DE TANGENTA DE DELTA SAUTESTUL BORNELOR DE TANGENTA DE DELTA SAUTESTUL BORNELOR DE TANGENTA DE DELTA SAUCAPACITATECAPACITATECAPACITATECAPACITATE

Testele de verificare a starii izolatiei bornelor de masura a capacitatii sau a tangentei dedelta se efectueaza in montajul GST cu legaturile de joasa gardate. Pentru acest test firulde I.T. este conectat la borna de tangenta de delta a izolatorului, firul rosu la central iarflansa de montaj la masa. Acesta metoda masoara numai izolatia dintre borna de masurasi pamant si nu este apreciabil afectata de legaturile conductorului central.

ATENTIE Bornele de masura a tangenta de delta sunt normal proiectae sa rezistela o tensiune de 500V iar cele de capacitate au tensiunea nominalacuprinsa intre 2,5 kV la 5 kV. Inaintea aplicarii tensiunii de test bornei demasura, tensiunea maxima de siguranta trebuie cunoscuta. O supratensiune aplicata bornei de masura o va face neutilizabila.

Unele izolatoare nu au borne de masura a capacitatii sau tangenta de delta sau o flansaizolatoare de montare. Aceste tipuri de izolatori vor fi electric izolati de echipamentul debaza pentru a fi testati. Aceasta poate insemna scoaterea bolturilor metalice de montare siinlocuirea temporala cu bolturi izolatoare. Mansoanele izolatoare intre flansa izolatorului siechipamentul de baza in mod normal asigura o izolare suficienta pentru a efectua teste inconfiguratie UST.

Evaluarea rezultatelor

Interpretarea masuratorilor capacitatii si tangenta de delta a izolatoarelor necesitacunostinte asupra constructiei izolatorilor datorita caracteristicilor particulare. De exemplu ocrestere a tangentei de delta pentru un izolator cu ulei indica probabil contaminareauleiului, in timp ce cresterea capacitatii si a tangentei de delta indica cel mai probabilexistenta apei in ulei.Cu exceptia scopului precis de a cerceta influenta curentului de suprafata, suprafataexterioara a izolatorilor trebuiesc sterse si uscate pentru a preveni influenta acestoraasupra rezultatelor. Efectele pierderilor datorate curentilor de suprafata se elimina atuncicand folosim metoda de test UST.

Corectiile cu temperatura, pentru fiecare tip de izolator, trebuiesc stabilite cu grija prinmasuratori si toate valorile trebuiesc corectate cu temperatura, uzual 20 °C estetemperatura de referinta. Valoarea masurata a temperaturii este cea corspunzatoaresuprafetei izolatorului. Temperatura aerului se va inregistra de asemenea.

DACOM IMPEX S.R.L. V4.0

108

Page 109: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

MASINI ROTATIVEMASINI ROTATIVEMASINI ROTATIVEMASINI ROTATIVE

Scopul principal al masurarii tangentei de delta si capacitatii la generaroare este evaluareaextinderii golurilor din interiorul izolatiilor, si in consecinta deteriorarea structurii acesteiadatorita ionizarii. Masuratori efectuate asupra infasurarilor vor da de asemeni indicatiiasupra eventualelor probleme datorate contaminarii, patrunderii umezelii, etc.

Masuratori ale tangentei de delta in mod “tip-up" este o metoda raspandita in mentenantageneratoarelor si evaluarea extinderii deteriorarii izolatiei cauzata de ionizare. In acest testtangenta de delta este masurata la doua tensiuni diferite, prima suficient de josa ca sa nuapara ionizari, normal 25% din tensiunea nominala de la faza la pamant, iar a doua latensiunea nominala sau putin mai redusa (la noi 80% din Un). Valoarea ”tip-up" esteobtinuta prin diferentierea celor doua valori, tangenta de delta la 0,25*Un minus tangentade delta la 0,8*Un .Atunci cand valoarea tangentei de delta creste semnificativ peste o anumita tensiune esteevident ca ionizarea este activa si produce ceva pierderi. O crestere a tangentei de delta lao anumita tensiune este un indiciu asupra valorii tensiunii la care apar ionizarile si dauindicatii ca actiunea ionizarii se va accelera. Daca golurile sunt scurtcircuitate prin aparitiaionizarii o anumita crestere a capacitatii rezulta. Orice predictie a timpului de viata ramastrebuie sa fie bazata pe cunoasterea comportamentului izolatiei respective la ionizari.In general bobinele situate linga barele de intrare, lucrand la tensiunea cea mai ridicata,sunt cele mai afectate de ionizari. Durata de viata a generatoarelor poate fi adeseaprelungita, cunoscand curbele tangentei de delta- tensiune pentru toate infasurarile, prininlocuirea numai a celor mai proaste si regruparea lor astfel incat barele cu cea mai micacrestere a tan delta, si preferabil si cea mai scazuta valoare, sa fie situata la borne.O alta posibilitate de extindere a vietii infasurarilor se poate obtine in cele mai multe cazuriprin ridicarea curbelor tangenta de delta-tensiune pe grupuri de bare pe baza carora serearanjeaza legaturile acestora la linii si nul. Acest principiu se poate aplica de mai multeori pe durata de viata .In general masuratorile pe stator sau rotor sunt facute asupra izolatiei dintre infasurari sinul. In cazul statorilor, unde conexiunule dintre infasurarile si steaua generatoruluil pot fidesfacute, masuratori suplimentare se efectueaza pentru izolatia dintre faze. Cand un testtip-up este efectuat pe o faza completa, numai valoarea medie este masurata, o sectiuneizolata cu tangenta de delta foarte ridicata poate fi mascata.Tabelul 11 indica conexiunile specifice dintre setul de test si statorul unui generator trifazat,precum si seriile de teste de rutina. Se presupune ca legaturile dintre faze si pamant suntdesfacute. Izolatia faza catre pamant este masurata prin metoda GST, in timp ce izolatoriidintre faze prin metoda UST. Cand se testeaza generatoare mari, care au valori ridicate ale capacitatii pe faza, valoareamaxima a capacitatii masurate la o tensiune anumita este limitata de sursa de alimentare.In aceste situatii testele se vor efectua la o tensiune mai mica.Temperatura infasurarilor masurate va fi aproximativ aceeasi cu cea a mediului ambiant siniciodata mai joasa spre a preveni condensarea. Valoarea temperaturii masurate, folositepentru corectii de temperatura, trebuie sa fie cea de la suprafata infasurarii.Trebuie prevenita mentinera prelungita, in conditii de umiditate crescuta, inaintea testului,pentru ca o asfel de expunere conduce la absorbtia umezelii de catre materialeleizolatoare. Este de dorit sa se realizeze teste pe infasurare la scurt timp dupa deconectare.

DACOM IMPEX S.R.L. V4.0

109

Page 110: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Tabelul 11: Conexiuni pentru stator trifazat (Motoare si generatoare)

Configuratia Legaturilor de joasatensiune

Conexiuni lainfasurari

Test

No.Izolatiatestata

ModTest Masurat Impamantat Gardat Black Red Blue Obs

1A to

GSTRed &Blue A B C B & C Guarded

2 A to B UST Red Blue A B C C Grounded

3B to

GSTRed &Blue B C A C & A Guarded

4 B to C UST Red Blue B C A A Grounded

5C to

GSTRed &Blue C A B A & B Guarded

6 C to A UST Red Blue C A B B Grounded

7 A + B +

C to

GSTGND A,B,C

May requireResonating

Inductor

Circuit echivalentA = Infasurare faza AB = Infasurare faza BC = Infasurare faza B G = Ground - pamantObservatii Nota: Scurtcircuitati fiecare infasurare.

DACOM IMPEX S.R.L. V4.0

110

Page 111: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

CABLURICABLURICABLURICABLURI

Cablurile ce opereaza la tensiuni in jur de 5 kV sunt uzual invelite intr-o manta metalica.Masuratori pentru astfel de cabluri se fac in modul GST GROUND si verifica izolatia dintreconductorul central si invelis. Firul de I.T. este aplicat conductorului iar mantaua este pusala pamant.La testarile cablurilor cu trei conductori, care au o singura manta metalica, configuratia USTeste folosita pentru testele izolatorilor dintre conductori (pentru fiecare combinatie testulUST se aplica la un conductor in timp ce cei ramasi se impamanteaza), iar a douasecventa de teste se va realiza in configuratie GST test cu gardare (GST with guarding),pentru fiecare conductor si manta, cu conductorii ramasi gardati. Un al treilea set de testese va face intre toti conductorii conectati impreuna si pamant, configuratie GST. Acestprocedeu este similar celui folosit la transformatoarele cu trei infasurari.

Valorile masurate se refera la media tangentei de delta a cablului. Pentru cabluri lungi esteposibila existenta unei sectiuni ce are o valoare ridicata de pierderi, pierderi ce pot ficomplet mascate astfel incat nu influenteaza deloc media tan delta. In aceste conditiirapiditatea detectarii defectelor scade cu cresterea lungimii cablului. Testele pe sectiunilungi de cabluri dau rezultate numai prin comparatii cu masuratori anterioare, sau cablurisimilare, relevand probleme ca umiditate, deteriorarea izolatiei, contaminare cu diversesubstante, etc.

Cablurile au inerent valori ridicate ale capacitatii unitare, tipic 0,3uF pe faza si km, astfelincat pentru lungimi mari se cere o valoare ridicata a puterii sursei setului de test.

DACOM IMPEX S.R.L. V4.0

111

Page 112: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

DESCARCATOAREDESCARCATOAREDESCARCATOAREDESCARCATOARE

Un test complet al unui descarcator implica tehnici in impuls si teste cu supratensiuni,precum si teste de pierderi dielectrice la tensiuni specificate si frecventa 50/60 Hz.Tehnicile in impuls precum si cele de supratensiune nu sunt in general realizate pe terenpentru ca implica echipamente mari, greu transportabile. Experienta a demonstrat camasuratorile pierderilor dielectrice este o metoda efectiva de lucru, permitand evaluari aleintegritatii descarcatoarelor. Aceste teste pot indica stari ce afecteaza functia protectiva ca:umiditate, depuneri de saruri, coroziune, crapaturi, deschiderea rezistentei de sunt,elemente de preionizare, etc.Pentru a aprecia starea unui descarcator, se va masura tangenta de delta sau pierderile inWatt la o tensiune specificata, comparandu-se cu valori masurate anterior ale aceluiasiechipament sau a unuia similar. Masuratorile unui descarcator se vor efectua intotdeaunala aceeasi temperatura atat timp cat in constructia lor intervin elemente cu neliniaritatiridicate. Tensiunea de test la care se fac referintele este de 10 kV. Cu exceptia investigariiscurgerilor de suprafata, pentru masurari normale suprafata descarcatorului se va curata siusca pentru a obtine valori corecte, neinfluentate de curentii de scurgere.Anumite tipuri de descarcatoare au o caracteristicia tangenta de delta dependentasubstantial de temperatuta, in timp ce altele practic sunt foarte putin influentate. Curbe decorectii cu temperatura pentru fiecare tip de descarcator trebuiesc stabilite, si toate valorilese vor corecta corespunzator valorii temperaturii de referinta, uzual 20°C.Temperatura descarcatoarelor se considera cea masurata la suprafata. Temperaturaaerului se va inregistra deasemenea. Suprafata dispozitivului testat va fi la o temperaturasituata peste cea a punctului de roua pentru a preveni fenomenul de condensare.

ATENTIE Atentie maxima in cursul masuratorilor efectuate la descarcatoaresuspecte a fi defecte, unele fiind realizate cu gaz sub presiune ridicata.

Este recomandat ca testele sa se efectueze pe elemente individuale si nu pe coloanerealizate din mai multe unitati. Un element se poate testa in mod UST in laborator, iar peteren se pot testa in mod GST, pentru aceasta descarcatorul fiind asezat pe un suport.Tabelul 12 arata procedura de test recomandata pentru testarea coloanelor dedescarcatoare in teren. Se intelege ca barele de alimentare vor fi decuplate.Valorile pierderilor la descarcatoare sunt adesea date in watt. Formulele de conversieechivalente pentru testul la 10 kV pornind de la capacitate si tangenta de delta sunt datemai jos.

DACOM IMPEX S.R.L. V4.0

112

Page 113: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

Watt (pierderi) = CpF x %DF x 377 x 10-6 (for 60 Hz)Watt (pierderi) = CpF x %DF x 314 x 10-6 (for 50 Hz)

unde: CpF = capacitatea in picofarazi%DF = tangenta de delta in procente

Obs: Capacitatea, tangenta de delta, factorul de putere si pierderile directe in watt la 10kVse pot citi direct de pe ecranul setului de test. Formulele sunt date cu titlu informativ.O crestere a valorii tangentei de delta sau a pierderilor in watt comparativ cu valorianterioare sau echipamente similare pot indica: umezeala, depuneri de saruri, portelancrapat, goluri datorate fenomenului de corodare.Descresterea valorilor masurate ale tangentei de delta sau pierderilor in watt indica:desfacerea suntului rezistiv, elemente ce manifesta defect de preionizare.

Tabelul 12: Conexiunile pentru descarcatoare

Low Voltage LeadConfiguration

TestConnections ToSurge Arrester

TestNo.

Surge ArresterSymbol

Insulation Tested

TestMode Measure

sGroun

dsGuards

Black Red

Blue Remarks

1 SA -A UST Blue Red 2 3 1 Terminal 3 Grounded

2 SA - B UST Red Blue 2 3 1 Terminal 1 Grounded

3 SA - C UST Red Blue 4 3

4 SA - D GST Red 4 3 Terminal 3 Guarded

Nota: toate testele se fac la 10 kV.

In unele cazuri izolate este necesara conversia pierderilor echivalente de la 10 kV la 2,5kV. Conversia se poate face folosind formula urmatoare, adevarata numai pentrudescarcatoare care au o caracteristica liniara cu tensiunea.

Watt pierderi kV Watt pierderi kV@ . @2 5 1016

=

DACOM IMPEX S.R.L. V4.0

113

Page 114: MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE … 2000 v4.0.pdf · MANUAL DE UTILIZARE AVTM672001 PENTRU TRUSA AUTOMATA DE MASURARE CAPACITATI SI TANGENTA DE DELTA DELTA

Manual Delta 2000 Aplicatii si exemple

LICHIDELICHIDELICHIDELICHIDE

Pentru a masura tangenta de delta a lichidelor izolatoare se foloseste o celula speciala detest pentru ulei, ca cea realizata de Biddle 670511 Oil Test Cell ce este si portabila. Esteconstruita cu electrozi ce alcatuiesc armaturile unui condensator, al carui dielectric ilconstituie lichidul izolator. Celula de test este cu trei terminale, cu electrod de pasivizare(gardare), pentru a preveni efectul de margine si efecul izolatiei suport pentru electrozi.

Esantioane de ulei se masoara in astfel de celule pentru a stabili constanta dielectrica.Raportul dintre valoarea masurata a celulei goale (dielectric aer) si a celulei pline (dielectriculei) este constanta dielectrica a uleiului testat.Instructini pentru utilizarea unei celule de test sunt date in Manualul AVTM670511.

COMPONENTE SI SUBANASAMBLECOMPONENTE SI SUBANASAMBLECOMPONENTE SI SUBANASAMBLECOMPONENTE SI SUBANASAMBLE

Cand un echipament este dezasamblat pentru reparatii si pentru a localiza defecte, testede tangenta de delta se pot efectua pentru a detecta zone cu probleme ale izolatiei, peizolatii ca: parti de lemn, fibra de sticla, ghidaje, roti de ghidare, membrane, etc. In unelecazuri existenta unei parti metalice poate fi folosita ca electrod de masura. In unele cazurieste necesar sa asiguram noi electrozi. Pot fi folosite benzi conductive; folia de aluminiu sepoate folosi cu succes. Acolo unde se foloseste material conductor asigurati-va ca existacontact ferm intre partea metalica si suprafata izolatorului testat. Se pot folosi unsorispeciale pentru a asigura un contact fizic al suprafetelor cat mai bun.Este necesar uneori sa separam pierderile de volum de cele de suparfata. Pentru aceastase poate folosi un al treilea terminal de gardare al sistemului de test. De exemplu un tubizolator, peste o bara conductoare poate fi testata pentru integritatea izolatiei. O banda(sau folie) conductoare este aplicata apoximativ pe mijlocul tubului izolator, iar alteleaditionale (garda), de o parte si de alta a benzii centrale, la distante suficiente pentru arezista tensiunii aplicate. Cu bara metalica impamantata, setul de test va masuracapacitatea si tangenta de delta a volulmului izolatiei intre banda centrala (Inalta tensiune)si bara metalica.

Comparatii dintre tangenta de delta a zonelor suspectate si a celor presupuse a fi in buneconditii sunt foarte utile pentru evaluare. Caracteristica tangenta de delta /tensiune poateindica existenta fenomenului de ionizare, prin folosirea metodei ‘tip-up’. Delaminarea intr-un material poate fi pusa in evidenta prin acesta cale. Atentie deosebita trebuie acordatatensiunii de test pentru a nu depasi tensiunea maxima de lucru.

DACOM IMPEX S.R.L. V4.0