infoelectrica 19

13

Upload: jumara-vasile

Post on 06-Aug-2015

34 views

Category:

Documents


1 download

DESCRIPTION

Revista de informatii electrice

TRANSCRIPT

Page 1: InfoElectrica 19
Page 2: InfoElectrica 19

2InfoElectrica nr. 19 - MAI 2010

Revista sponsorizata de firma

CUPRINSEditorial ....................................................................................................................................................3

Lansarea Concursului National "Electricianul Anului 2010" ...................................................................3EvEnimEntE ...............................................................................................................................................4

Construct Expo 2010......................................................................................................................................4ilUminat......................................................................................................................................................5

Proiectarea si constructia surselor de iluminat cu LED.............................................................................5ElEctrotEhnica .....................................................................................................................................7

Stadiul actual in constructia si controlul filtrelor active - Redresoare, invertoare, filtre active (contin-uare).................................................................................................................................................................7Reglarea tensiunii în instalaţiile de utilizare prin montarea în serie a condensatoarelor. ......................9tEst dE pErspicacitatE in aUtomatizari ................................................................................13

Rebusul nr 8..................................................................................................................................................13

Colectiv redactional InfoElectrica :

Ion Calota - redactor sef, [email protected] Milici - redactor Echipamente de masura, [email protected] Matei – redactor Iluminat , [email protected] Peste - redactor Energetica, [email protected] Turcu - redactor Aplicatii practice, [email protected] Morancea - redactor Electrotehnica, [email protected] Gurguiatu – redactor Calitatea energiei, [email protected] Beiu - designer, tehnoredactor, [email protected]

Conform legii, textele si materialele din aceasta revista nu pot fi reproduse sau utilizate in alte medii fara acordul

autorilor. Revista poate fi multiplicata si distribuita, doar sub forma gratuita, fara modificari aduse starii initiale.

Responsabilitatea corectitudinii datelor din articole revine doar autorilor acestora. Date complete despre firmele si

persoanele prezentate in revista le gasiti pe http://www.PortalElectric.Ro .Cei care sunt interesati de reclama in

aceasta revista sau doresc sa publice articole vor trimite mesaj redactorului sef, la adresa [email protected]

Page 3: InfoElectrica 19

In urma succesului deosebit de care s-a bucurat prima editie a Concursului National "Electricianul Anului" desfasurata in anul 2009,

AREL si-a propus sa creeze o traditie prin organizarea in fiecare an a acestui eveniment.

Acest concurs doreste sa dezvolte spiritul competitivitatii in randul electricienilor si de asemenea sa popularizeze imaginea reala a valorii

ridicate de pregatire a celor care lucreaza in domeniul electric.

Gandit in primul rand ca o sarbatoare a breslei electricienilor, acest concurs doreste sa incununeze activitatea desfasurata pe parcursul

unui an de cei mai buni reprezentanti ai acestei meserii si totodata sa atraga tineri pasionati in practicarea ei.

Concursul National "Electricianul Anului 2010" va fi lansat oficial pe 14 mai in cadrul simpozionului organizat de AREL la Construct

Expo.

In avanpremiera va prezentam in continuare regulamentul de desfasurare al acestei editii.

Ion Calota - Presedinte AREL

Editorial

Regulamentul Concursului Na-tional "Electricianul Anului 2010"

ORGANIZATOROrganizatorul�Concursului�National�"Elec-tricianul�Anului� 2010"� este�Asociatia�Ro-mana� a� Electricienilor�AREL� ,� numita� incontinuare�Organizator.�Decizia�de�derularea�concursului,�conform�regulilor�din�prezen-tul�regulament,�este�finala�si�obligatorie�pen-tru�toti�participantii.

DURATA SI LOCUL DE DESFASUR-

ARE A CONCURSULUIConcursul� se� desfasoara� in� perioada:� 15iunie�-�16�septembrie�2010.Etapa�finala�si�festivitatea�de�premiere�voravea�loc�in�cadrul�expozitiei�IEAS,�care�seva�desfasura�in�perioada�14-17�septembrie2010�la�Palatul�Parlamentului.�DK�Expo,�or-ganizatorul� IEAS,� detinand� statutul� departener�in�acest�concurs.�

DREPTUL DE PARTICIPARELa�acest�concurs�poate�participa�orice�per-soana�fizica�majora�care�are�o�calificare�indomeniul� electric.� Concurentii� trebuie� saaiba�cetatenie�romana.�Castigatorul�unui�tro-feu,�in�anii�anteriori,�de�"Electrician�al�Anu-lui"�nu�mai�poate�concura�la�acest�concurs.

INSCRIEREA LA CONCURSPentru�inscriere�in�concurs�se�vor�expedia�ur-matoarele�documente�:-copie�act�de�identitate-copie�act�de�calificare�in�domeniul�electric-CV�cat�mai�complet�cu�activitatea�desfasur-ata�in�domeniul�electric-proba�de�concurs,�reprezentand�detaliile�de-spre�o�lucrare�sau�maxim�2�lucrari,�la�careconcurentul�a�participat�efectiv�in�perioada15�iunie�2009�-�15�august�2010.�Proba�poatesa� contina� :� text� de� prezentare,� schite,scheme,�imagini,�referinte�si�recomandari�de

la�cei�care�cunosc�lucrarea�respectiva.��Lu-crarea�trebuie�sa�se�refere�la�partea�de�exe-cutie,�dar�poate�face�referire�si�la�partea�deproiectare� precum� si� verificari,� punere� infunctiune.��Poate�fi�de�orice�nivel�de�tensiunesi� putere,� din� orice� specialitate� specificaelectricienilor.Documentele�pentru�inscriere�in�concurs�sevor� primi� in� perioada� 15� iunie-15� august2010.�Ele�se�vor�expedia�prin�email�la�[email protected]�.�Partic-ipantii�au�obligatia�sa�se�asigure�telefonic�sauprin�e-mail�ca�materialele�necesare�pentru�in-scriere� au� fost� primite� .� Recomandam� in-scrierea� din� timp� pentru� a� va� asigura� camaterialele�au�ajuns�in�timp�util.�Concurentiinu�vor�plati�nici�un�fel�de�taxa�pentru�partic-ipare.

DESCALIFICAREIn� cazul� in� care� oricare� dintre� concurentilezeaza� drepturile� sau� afecteaza� imagineaOrganizatorului� sau� a� altor� concurenti,� inorice�fel,�acesta�poate�fi�eliminat�din�concurs.Documentele� inscrise� trebuie� sa� fie� con-forme�cu�realitatea.�Datele�pot�fi�verificate.In�cazul�constatarii�existentei�oricarei�tenta-tive�de�frauda�aceasta�va�conduce�la�descal-ificarea� concurentului� si� interzicereaaccesului�in�viitor�la�concursurile�organizatede�Organizator�.�Organizatoriul�nu�isi�asuma�nici-o�raspun-dere�in�cazul�in�care�lucrarile�inscrise�folos-esc� elemente� de� continut� (texte,� imagini,scheme�etc.)�care�incalca�drepturile�de�autorsau�de�securitate�a�datelor.�Intreaga�raspun-dere�apartine�celui�care�a�inscris�lucrarea.�

JURIZAREAPrima�etapa�de�jurizare�va�avea�loc�in�pe-rioada�16-31�august�2010,�cand�se�va�facepreselectia�celor�10�participanti�la�etapa�fi-nala.�Juriul�acestei�etape�va�fi�format�din�5membri�care�vor�fi�desemnati�de�ConsiliulDirector�AREL�pana� la�data�de�16�august.

Acestia�nu�trebuie�sa�fie�dintre�cei�inscrisi�laconcurs�.�Juriul�va�aprecia�:�calitatea�lucrar-ilor,�aplicarea�tehnologiilor�noi,�respectarealegislatiei� in� domeniu,� originalitatea,� efi-cienta�aplicatiei,�nivelul�de�pregatire�practicasi� teoretica,� corectitudinea� lucrarii,� re-spectarea� normelor� de� securitatea� muncii,credibilitatea�si�acuratetea�informatiilor�etc.Daca�vor�considera�necesar�membrii�juriuluipot�contacta�participantii�la�concurs�pentru�acere�completari�sau�a�verifica�veridicitateacelor�prezentate.�Etapa�finala�a�concursului�va�avea�loc�in�datade�16�septembrie,�in�cadrul�IEAS�2010,�candcei�10�finalisti�vor�raspunde�la�un�test�grilade�20�de�intrebari�de�cunostinte�generale�dindomeniu�electric.�Acesta�va�conta�in�propor-tie�de�10%�din�punctajul�final.�Un�nou�juriu,�care�va�delibera�clasamentulfinal� va� fi� numit� in� data� de� 1� septembrie2010,�de�Consiliul�Director�AREL�si�va�aveain�componenta�5�membri�.�Cele� 2� Jurii� vor� primi� documentele� con-curentilor�in�mod�anonim.Calcularea��si�anuntarea�punctajului�final�seva�realiza�in�cadrul�evenimentului�organizatde� AREL� in� data� de� 16� septembrie,� inprezenta�concurentilor,�a�organizatorilor,�asponsorilor,�a�publicului�si�a�reprezentantilorpresei�care�vor�participa�la�eveniment.�

PREMIILE OFERITEOrganizatorul�ofera�urmatoarele�premii�:-Trofeul�"Electricianul�Anului�2010"-Premiile�1,�2�si�3-6�Mentiuni�pentru�participarea�in�faza�finala.Festivitatea�de�premiere�va�avea�loc�in�datade�16�septembrie�2010,�cand�AREL�orga-nizeaza�simpozionul�tehnic�din�cadrul�IEAS.�Premiile� vor� consta� in� diplome,� trofee,echipamente�din�domeniul�electric,�sume�debani,�aparate�si�alte�obiecte�oferite�de�spon-sori� si�de�organizatori,� iar�castigatorii�vorbeneficia�si�de�promovare�mediatica.�Casti-gatorul� Trofeului� va� primi� de� asemenea

Lansarea Concursului National "Electricianul Anului 2010"

3InfoElectrica nr. 19 - MAI 2010

Page 4: InfoElectrica 19

4InfoElectrica nr. 19 - MAI 2010

diploma�si�statutul�de�Membru�de�Onoare�alAsociatiei�Romane�a�Electricienilor,�asta�in-semnand� printre� altele� ca� nu� va�mai� platitoata�viata�cotizatie�la�AREL.�Atat�juriul�catsi�organizatorii�pot�decide�acordarea�si�unoraltor�premii�sau�mentiuni�speciale�.�Organizatorul�concursului�nu�este�raspunza-tor�de�plata�taxelor�sau�a�altor�obligatii�finan-ciare�legate�de�premiile�oferite,�acestea�fiindin�sarcina�persoanelor�castigatoare.

LITIGII

Eventualele�litigii�aparute�intre�Organizatorsi�participantii�la�concurs�se�vor�rezolva�pecale�amiabila�sau,�in�cazul�in�care�aceasta�nuva�fi�posibila,�litigiile�vor�fi�solutionate�deinstantele�judecatoresti�romane�competente.

DISPOZITII FINALE

Concursul�va�putea�fi�intrerupt�doar�in�cazde�forta�majora�sau�printr-o�decizie�a�orga-nizatorului.

Regulamentul�de�participare/desfasurare�estedisponibil�in�mod�gratuit�oricarui�solicitant�.Toate�datele�furnizate�cu�ocazia�participariila�acest�concurs�pot�fi�folosite�de�Organizatorin�scopuri�publicitare.�Participand�la�acestconcurs�esti�de�acord,�ca�in�cazul�castigariiunui�premiu� imaginea� ta� sa� fie� folosita� inscopuri�publicitare,�sau�pentru�activitati�vi-itoare�de�marketing.�Prin�participarea�la�acestconcurs� se� considera� cunoscut� si� acceptatprezentul�Regulament.

In� premiera,� cu� ocazia� CONSTRUCTEXPO AMBIENT se�va�desfasura�primaeditie�a�salonului�specializat�de�piscine�si�spa,organizat�in�Romania.�Salonul�va�reuni�celemai� importante� companii� producatoare� sidistribuitoare�de�piscine,�spa-uri,�accesorii�siconsumabile�pentru�acestea.

Aceste�manifestari�expozitionale,�de�traditiepentru� ROMEXPO,� au� ajuns� la� cea� de� aXVII-editie� si� reunesc� tematici� specificedomeniului�constructiilor�si�instalatiilor:

CONSTRUCT EXPO AMBIENT:

*�produse�pentru�amenajari�interioare�siexterioare� (pardoseli-parchet,� marmura,placi�ceramice,�mobilier�de�baie,�tapet,�fere-stre�si�usi,�piscine�&�SPA);

CONSTRUCT EXPO ANTREPRENOR:

*�materiale�de�constructii�(piatra,�zidarii,structuri� beton� armat,� structuri� de� lemn,structuri�metalice,�termo�si�hidroizolatii,�in-velitori),� instalatii� electrice,� echipare� desantier;

CONSTRUCT EXPO UTILAJE:

*�utilaje�pentru�constructii,�componente�siservicii,�accesorii�si�piese�de�schimb�pentruutilaje�de�constructii

ROMTHERM:

*�echipamente�de�incalzire�si�conditionarea�aerului,�instalatii�sanitare

In�perioada�11-15�Mai�2010,�vizitatorii�care

vor�trece�pragul�Complexului�ExpozitionalROMEXPO,�vor�putea�asista�la�demontratiide�aplicare�de�tencuieli�decorative,�amena-jarea�si�decorarea�unei�incaperi�respectindprincipiile�feng-shui,�decorarea�unei�camerein�functie�de�tendintele�in�materie�de�culorisi�texturi.De� asemenea,� specialistii� interesati� suntasteptati�in�pavilionul�1�pentru�a�primi�infor-matii�legate�de�utilizarea�produselor�de�con-structii

Manifestari�conexe�organizate�in�perioada11�-15�mai�2010:

Sala�Iorga�(pavilion�18,�etaj),�11�Mai,�orele11.30�-�18.00•Conferinta�cu�tema:�“Renovarea�cladirilorrezidentiale�in�concept�de�casa�pasiva”.Organizator:� GRUPUL� DE� PRESA� RE-PORTER

Sala� Balcescu� (pavilion� 18,� etaj),� 12�mai2010,�orele�10.00-18.00•Conferinta�nationala�„Lemnul�–�un�produspentru�dezvoltarea�durabila�în�constructii”Organizator:Asociatia�Producatorilor�de�Ma-teriale� de� Constructii� din� Romania(APMCR)Parteneri:�Ministerul�Economiei,�Comertuluisi�Mediului�de�Afaceri,�Ministerul�Educatiei,Cercetarii,�Tineretului�si�Sportului�si�ROM-EXPO

Sala�Iorga�(pavilion�18,�etaj),�12�mai�2010,orele�10.00–11.00•Prima�conferinta�de�presa�a�Asociatiei�Na-tionale� a�Montatorilor� de�Acoperisuri� dinRomania�(ANMAR)

Sala�Iorga�(pavilion�18,�etaj),�12�mai�2010,orele�12.00–17.00•Seminar�„Constructia�piscinelor�publice”Organizator:� Asociatia� Patronala� pentruPiscine�si�Wellness�(APPW)

Sala�Titulescu,�13�mai�2010,�orele�10.00–18.00•„Solar�Day”�–�Conferinta�Romania-oportu-nitate�de�afaceri�in�domeniul�energiei�solareOrganizator:�Asociatia�Patronala�Surse�Noide�Energie�–�SunEParteneri:�Ministerul�Dezvoltarii�Regionalesi�Turismului�si�ROMEXPO

Sala� Cupola� (pavilion� 1,� parter),� 13� mai2010,�orele11.00–16.00•„Ziua�Arhitecturii”:�lansare�de�carte�si�re-viste�de�arhitectura�si�urbanism�•�Conferinteale�cadrelor�didactice�sub�denumirea�gener-ica�„Orasul,�cladirea,�spatiul�si�tehnologiilecontemporane”Organizator:�Universitatea�de�Arhitectura�siUrbanism�„Ion�Mincu”

Sala�Madgearu� si� Brancusi,� 13�mai� 2010,orele�10.00-16.00•Atelier�de�lucruOrganizator:�Asociatia� Distribuitorilor� deUtilaje�pentru�Constructii�(ADUC)

Sala� Cupola� (pavilion� 1,� parter),� 14� mai2010,�orele�10.00�–�14.00•Prezentarea�ghidului�în�limba�romana�de-spre�aplicarea�marmureiOrganizatori:�AIDICO�si�Asociatia�MarmolAlicante�-�Spania

Sala�Iorga�(pavilion�18,�etaj),�14�mai�2010,orele�10.00–18.00

EvEnimEntE

Construct Expo 2010

CONSTRUCTII SI INSTALATII DE LA A LA Z, IN PERIOADA 11-15 MAI 2010, LA ROMEXPO

Page 5: InfoElectrica 19

Asociatia Romana a Electricienilor aincheiat un parteneriat cu Asociatia

Romana de Electrosecuritate

5InfoElectrica nr. 19 - MAI 2010

•Forumul�Electricienilor� la�CONSTRUCTEXPO„Tehnologii� noi� în� constructia� instalatiilorelectrice”Organizator:�Asociatia�Romana�a�Electricie-nilor�(AREL)

Pavilionul 1, nivel 3.20, 15 mai 2010, orele10.00-14.00

•„Ziua culorilor”�–�demonstratii�de�aplicaretencuieli�decorativeOrganizatori:� Asociatia� Producatorilor� deMateriale� de� Constructii� din� Romania

(APMCR)�si�ROMEXPO�SA

Platforma 29, toata perioada

•„Zilele meseriasului”�-�demonstratii�privindmodalitatea�executarii�unei�sarpante�si� în-velirea�ei�cu�diverse�materiale�specifice�(tiglaceramica�/�beton�/�metalica,�sindrila�etc.)�pre-cum�si�montajul�sistemelor�conexe�(sistemulpluvial,�fereastra�de�mansarda,�panoul�solar,cosul�de�fum)Organizatori:�Asociatia�Nationala�a�Monta-torilor� de� Acoperisuri� din� Romania(ANMAR)�si�ROMEXPO

•Consultanta�pentru�utilizarea�produselor�deconstructii�(bricolaj)Organizatori:�Asociatia�Producatorilor�deMateriale� de� Constructii� din� Romania(APMCR)� si� ROMEXPO� SA

Perioada: 11 - 15 mai 2010

Programul� de� vizitare:� zilnic� intre� orele10.00-18.00,�ultima�zi,�15�mai�2010,�intreorele�10.00-16.00Pretul�biletului�de�intrare:�5�RON

Asociatia Romana a Electricienilor AREL siAsociatia Romana de Electrosecuritate ARESsunt�asociatii�profesionale�ne-guvernamentale�careau�interese�comune�in�promovarea�si�dezvoltareaelectro-securitatii,�nerespectarea�normelor�de�securtate� in� instalatiile� electrice� fiind� cauze� multorevenimente�negative�grave�in�societatea�actuala.Astfel� aceste� doua� organizatii� au� semnat� unparteneriat�pentru�orientarea�eforturilor�tehnice,�or-ganizatorice�si�financiare�care�vizeaza�interventiaeficace�în�procesul�cauzal�al�incidentelor,�acciden-telor�de�munca�si�îmbolnavirilor�profesionale�gen-

erate�de�factorii�de�risc�electric,�cauzatoare�si�dedaune�materiale�importante.Cateva�din�obiectivele�comune�ale�acestui�partene-riat�:-�Suntem�preocupati�de�crearea�si�promovarea

unei�punti�de�dialog�si�a�unei�colaborari�strânse�îndomeniul�electrosecuritatii�în�munca�cu�factorii�gu-vernamentali,�cu�organizatiile�patronal�si�sindicale;-�Suntem�angajati�în�elaborarea�unor�proiecte�de

acte�normative,�consacrate�îmbunatatirii�legislatieide�S.S.M�si�electrosecuritate;-��Acordam�servicii�de�consultanta,�pe�baza�de

contract�cadru�de�prestari�servicii,�angajatorilor�sipersoanelor�fizice,�în�domeniul�electrosecuritatiiîn�munca�si�domenii�conexe;

-� Desfasuram� activitati� didactice� privindsustinerea�de�cursuri�de�formare�profesionala�con-tinua�la�nivel�mediu�si�superior;-�Elaboram�publicatii�de�specialitate�(îndrumare,

ghiduri,�manuale,�brosuri,�fise�informative);-�Asiguram�asistenta�juridica�pentru�membrii

asociatiei,�în�litigiile�referitoare�la�respectarea�leg-islatiei�de�securitate�si�sanatate�în�munca.

prof.dr.ing Stelian Matei

ilUminat

Proiectarea si constructia surselor de iluminat cu LED

Partea 5 -Consideratii termice

Intr-un aparat de iluminat cu LED, temperatura de functionare ridicata este cauza prin-

cipala a defectarii. Intelegerea si implementarea cu succes a conceptului de manage-

ment termic pentru emitatoarele LED este absolut necesar. Acest concept implica

transferul eficient al caldurii emise cat mai departe de jonctiunea semiconductoare,

pentru a permite temperaturi reduse de functionare. Acest proces incepe cu aparatul de

iluminat in sine unde provocarea consta in reducerea caldurii retinute in interiorul

aparatului si disiparea catre exterior sau compensarea efectului ei. In caz contrar emi-

tatoarele LED isi vor deprecia eficienta luminoasa si in ultima instanta se vor defecta.

IntroducereEmitatoarele�LED�din�aparatele�de�ilumi-nat�au�un�coeficient�negativ�de�temper-atura�asemanator�diodelor�redresoare.�Caurmare,� variatiile� de� temperatura� vorafecta�si�urmatoarele�caracteristici�speci-fice�emitatorelor�LED:�-intensitatea� luminoasa� (crestereatemeperaturii�produce�descresterea�inten-sitatii).�-lungimea�de�undă�a�culorilor�de�baza�cese�traduce�prin�variatia�temperaturii�cu-lorii� (creterea� temperaturii� producecresterea�lungimii�de�unda).Această�vari-atie�este�de�aproximativ�0,02�nm/°K�pen-tru�verde,�0.1nm/°K�pentru�galben�şi�0.06nm/°K�pentru�rosu.În�prezent,�LED-uri�fabricate�sunt�specifi-cate�la�temperaturi�de�funcţionare�de�25°C,unde�variatiile�intensitatii�luminoase�suntde�aproximativ�-1.5%/°C.�In�practica,�insatemperatura� unei� jonctiuni� LED,� estecuprinsa�intre�60°C�si�90°C�ceea�ce�ar�im-plica�deci�reducerea�curentului�prin�jonc-

tiue.�Ca�urmare�intensitatea�luminoasa�vafi�diminuata�corespunzator�dar�care�poatefi� compensat� � poate� fi� compensat� prinadaugarea� unui� alt� emitator� LED.Ca�urmare�a�cestei�situatii�producatorii�decomponente�LED�au�fost�obligati�sa�real-izeze�o�noua�generatie�de�emitatoare�LEDcu�forme�si�dimensiuni��diferite�sau�subforma� de� module� sau� matrice� cu� maimulte�structuri�semiconductoare�pe�ace-lasi� suport� sau� substrat.� Reducerea� saueliminarea� degradarii� intensitatii� lumi-noase�ca�urmare�a�cresterii�temperaturi,�serealizeaza�cu�un�sistem�de�racire/disiparetermica�bazat�pe�conductie�termica�(radi-ator),�si/sau�un� �circuit� �de�compensare(unitar)�a�temperaturii.�Structurile�semi-conductoare�de�tip�cu�stratul�P�deasupra,pot�fi�tehnologic�usor�conectabile�cu�fir(wire�bond),�de�obicei�de�aur�(Fig.1),��darconductivitatea�termica�redusa�a�substrat-ului�de�safir�le�fac�nepotrivite�pentru�apli-catiile�de�putere.�Pentru�curenti�mari�insa,acest��cip�nu�poate�fi�conectat�prin�fir,�ca

Premiul "Articolul numarului 19"

Premiu sponsorizat de firma

Page 6: InfoElectrica 19

6InfoElectrica nr. 19 - MAI 2010

urmare�a�densitatiimari� de� curent.Deasemeni� estenecesar� un� mate-rial�de�substart�cuconductivitateatermica� si� trans-parenta� ridicatapentru�un�transfereficient�al�calduriisi� respecitv� a� lu-

minii�emise.�Transferul�luminii�catre�exteriorpoate� fi� si� mai� mult� imbunatatit� printr-oforma�specifica�a�peretilor�chip-lui�in�forma

de� trunchi� de� pi-ramida� raspurnata,unde�peretii�au�rolde� reflector� (Fig.2).�O�alta�tehnolo-gie�recent�folositala� emitatoareleLED�de�mare�put-ere� si� care� poartadenumirea� de

„flip-chip”,�combina�toate�aceste�avantaje�im-preuna�cu�un�substrat�metalic�cu�functiuneaata� de� radiator� cat� si� reflector.� Problematransferului� ter-mic� este� im-bunatatita� prinintroducerea�unuisubstrat� cu� con-ductivitate� ter-mica� ridicata� sicare�dirijeaza�cal-dura� spre� exte-rior,�pe�două�căidupă� cum� esteindicat� in�Figura3.� Extragerea� luminii� este� deasemni� im-bunatatiti�prin�pozitionarea�structurii�chip�in

centrul�unei�cupe�re-flectoare�(Fig.�4).Reducerea�tempera-turii�structurii,�estedeci�deosebit�de-osebit�de�importantpentru�a�evita�reduc-erea�degradari�lumi-noase,�în�special�căaceste�lămpi

funcţioneza�si�in�medii�calde,�unde�radiatiasolara�produce�în�interiorul�aparatului�tem-peraturi�ridicate.�Deasemni�materialulepoxidic�din�jurul�structurii�semiconduc-toare,�cu�functiuni�atat�optice�cat�si�protec-tive�are�limitări�termice.�În�cazul�în�careaceasta�depăşeşte�temperatura�de�tranziţiede�125�°�C,�materialul�epoxidic�începe�să�seînmoaie.�Acest�proces�este�reversibil,�mate-

rialul�intarindu-se�odata�cu�racirea�cipul-luiiar�repetarea�acestui�ciclu�va�produce�unstres�mecanic�componentei�semiconduc-toare.�În�consecinţă,�aceste�cicluri�pot�ducela�fisuri�epoxidice,�dezlipirea�structurii�sauruperea�conexiunilor.�Rezistenţa�termică�amicro�sistemului�LED�va�descrie�deci�cali-tatea�transmiterii�termice�între�joncţiune�şimediului�ambiant�(Fig.�5).�O�rezistenţă�ter-

mică�mică�poate�disipa�mai�bine�de�căldurăpoate�fi�disipată�şi�directionata�in�afarastructurii.�Rezistenta�termică�totala�jonc-tiune-mediu�înconjurător�(ambiant)�RthJAdescrie�abilitatea�sistemului�LED�de�dispain�exterior�caldura�caldura�acumulat�in�tim-pul�conversiei�de�lumina.�Ea�poate�fidespartita�în�componente�astfel�:�•�Rezistenta�termica�jonctiune-ambient�(ex-terior),

RthJ-A =�(TJ –�TA)�/�Pd

•�Rezistenta�termica�substrat�metalic�a�jonc-tiunii�la�circuit�imprimat,

Rthms -�PCB =�(Tms –�TPCB)�/�Pd

•�Rezistenta�termica�circuit�imprimat-ambient,

RthPCB�-�A =�(TPCB –�TA)�/�Pd

•�Rezistenta�termica�radiator�to�ambient,�

Rthhs�-�A =�(Ths –�TA)�/�Pd

Pentru�referinta�valorile�rezistentei�termicepentru� diferite� materiale� sunt� aratate� intabelul�urmator�:

Prin�urmare�structurile�emitaoare�pe�suportmetalic�de�cupru,�asigura�o�disipatie�termica

mult�mai�buna�in�comparatie�cu�celelalte�ma-teriale.�Temperatura� generata� în� zona� structuriisemiconductoare�este�transmisa�la�rama�su-port,�si�care�reprezinta�suprafata�spre�exteriorprin�intermediul�izolatiei�circuitului�impri-mat� la� radiator.�Temperatura� jonctiunii� nutrebuie�să�depăşească�limita�indicata�de�pro-ducator,�altfel�se�va�produce�o�îmbătrânire

precoce�sau�chiar�se�poate�sparge.�Având�învedere�că�măsurarea�temperaturii�joncţiuniieste�foarte�dificil�de�masurat�ea�este�de�regulădeterminată� de� din� rezistenţă� termică� dinecuaţia�de�mai�jos:

TJmax =�TA +�PDmax (RthJP +�RthPA)

unde:TJmax =� temperatura�maximă� a� jonctiuniiLEDTA =�temperatura�ambiantăPDmax =�puterea�maxima�disipata�admisibilaRthJS =�rezistenta�termica,�joncţiune-termi-nal�de�lipire�RthSA =�rezistenta�termica,�terminal-aerSuma� rezistentelor� termice� din� parantezereprezinta� rezistenţa� termică� totală� RthJA.Aceasta�are�o�parte�RthJS care�depinde�decomponenta�si�o�parte�RthSA care�depinde�deaplicatie� (densitatea� de� componente,suprafata�lipiturii).�Aceasta�din�urmă�este�foarte�importanta�şitrebuie� să� fie� in� atentia� proiectantului� deaparate�de�iluminat.Pentru� o� defini� rezistenţă� termică� RthJA,curentul�maxim�poate�fi�determinat�la�o�tem-peratură�maximă�a�mediului�ambiant.�Este�deremercat�faptul�ca�o�rezistenta�termica�maimica� a� emitatorului�LED� face� posibil� ali-mentarea�lui�cu�un�curent�mai�mare�la�tem-peraturi� mai� ridicate,� ceea� ce� permiteobtinerea�de�valori�mai�ridicate�ale�intensi-tatii�luminoase.�Spre�exemplu�daca�un�LEDare�10%�scaderea�intensitatii�la�un�curent�de50mA�şi�o� temperatură� ambiantă�de�85°Catunci�temperatura�jonctiunii�este�de�

TJmax =�120°C�şi�o�RthJS =�100K/W.

Fig 3. Structura semiconduc-

toare LED „flip - chip”.

Fig 4. Structura semi-

conductoare LED

„flip-chip”.

Fig 5. Micro sistem LED.

Cupru 1.46�W/°C

Aluminum 0.9�W/°C

Otel�inoxidabil� 0.1�W/°C

Plastic 0.0018�W/°C

Aer 7.3x10-5W/°C

Fig 1. Structura semiconduc-

toare LED cu conectare prin

fir.

Fig 2. Structura semiconduc-

toare LED in forma de

trunchi de piramida.

Page 7: InfoElectrica 19

7InfoElectrica nr. 19 - MAI 2010

Pentru�o�temperatura�ambiantă�maximă�de74°C�la�o�putere�disipata�de�maxim�105mW(pentru�50mA�la�2.1V),� rezistenta� termicaterminal-aer,�nu�trebuie�să�fie�mai�mare�de�

RthSA(max.) =�338�W/°C.�

Componentele� SMT� au� unele� avantaje� înceea�ce�priveşte�montarea�si�disiparea�tem-peraturii,�în�comparaţie�cu�aşa-numitele�LED"radiale"� sau� "through� hole".� Unul� dintreavantaje�este�că�LED�de�putere�SMT��pot�fimontate�pe�un�circuit�imprimat�cu�miez�demetal,�care�poate�reduce�impactul�tempera-turii� în�mod� dramatic.� Suprafeţa� necesarapentru� a� disipa� o� anumită� putere� pe� unasemenea�circuit�imprimat�este�de�aproxima-tiv�4�ori�mai�mica�decât�circuitul�obisnuit�de

tip� FR4� (Fig.� 6).� Acestlucru�înseamnă�o�disiparemai� buna� a� căldurii,� sideci�o�reducere�mai�micăa�intensitatii�luminoase�amodulului� LED.� Unmodel� termic� pentru� unemitator�LED�montat�peo�placă�de�circuit�impri-

mat�este�prezentată�în�ecuaţia�1.

TJ =�TA +�PD(J-P +�P-A)�=�TA +�PD(J-A),�(1)

Notă: temperatura terminalului este definita ca

temperatura lipiturii a terminalului catodului pe

un circuit imprimat, atunci când emitatorul LED

este in pozitie normala.

Unde:TJ =�temperature�jonctiunii�LED�TA =�temperature�ambientaPD =��puterea�disipata�(IF�inmulit�cu�VF)J-P =�rezistenta�termica,�jonctiune�to�pinulcathodeP-A =��rezistenta�termica�pin�to�aer

Atunci�când�mai�multe�LED-uri�emiţătoareLED�sunt�montate�pe�acelaşi�suport�(circuitimprimat),�rezistenta�termica�globala�va�fiafectata� din� cauza� încălzirii� suplimentareprodusa� de� emitatoarele� adiacente.� Acestlucru�va�modifica�RthPCB-A ,�deoarece�suntmontate�pe�acelaşi�suport,�iar�RthJ-MS a�maimultor�emitenţi�LED-uri�poate�fi�simplificatala�o�singura�valoare�RthJ-MS ce�reprezintarezistenta� termica� echivalenta� � in� paralel(obţinut�în�mod�similar�ca�calcul�a�rezistenţei

rezultanta� de� rezistenţe� în� paralel).�Acestmodel�este�ilustrat�în�Figura�7.Fig�7.�LED-uri�SMT-�LED�montate�pe�acelasi�circuit�im-primat.� Cand� acest� model� este� utilizat

puterea�disipata�totala�Pd�utilizata�este�cal-culata�astfel�:

Pd�total =�Pd1 +�Pd2 +�Pd3 +�……�+�Pdn

Iar�rezistenta�termica�totala�

RthJ-ms�total =�(�TJ –�Tms )�/�Pd�total

Înainte�de�a�trece�la�proiectarea�termica�pro-priu-zisa� urmatoarele� cerinţele� trebuiescprestabilite:A-Temperatura� maxima� a� camerei� undeurmeaza�sa�functioneze�(TA�max)�-�bazat�peconditia�stabilita�de�utilizator.B-Temperatura�maximă�a�jonctiunilor�LED(Tj�max)�-�pot�fi�obţinute�de�la�fişa�tehnică�aemitatorelor.�C-Puterea�maxima�disipată�pe�emiţător�LED(max.�Pd,��cazul�în�care�max�Pd =�IF�max xVF�max)�-�pot�fi�obţinute�din�fişa�tehnică�aemitatoarelor.La�proiectarea��radiatorului�trebuie�luat�inconsideratie� întotdeauna� scenariul� cel�maidefavorabil�al�sistemului.��în�considerare�ladeterminarea� necesare� cerinţa� de� căldurăscufundarea�a�sistemului.�

Fig 7. LED-uri SMT- LED montate pe acelasi

circuit imprimat.

Fig 6. SMT- LED

montat pe circuit

imprimat cu miez

de aluminiu.

Fig 8. LED-SMT si forma echivalenta de circuit

imprimat cu miez de aluminiu.

1. Redresorul trifazat de tensiune P.W.M.Invertoarele�PWM�(Pulse�Width�Modulation=�MID�Modularea�Impulsurilor�în�Durată)�detensiune� asociate� maşinilor� asincrone� tri-fazate� în�colivie�se�produc�astăzi�pe�scarăfoarte�largă,�înlocuind�cu�succes�acţionărilede�c.c.,�mai�puţin�fiabile�şi�mai�voluminoase.

În�marea�lor�majoritate,�aceste�in-vertoare�au�prevăzut�un�redresor�necomandatcu�diode�pe�partea�reţelei�pentru�producereatensiunii� de� c.c.� din� circuitul� intermediar.Aceste�tipuri�de�redresoare,�deşi�se�remarcăprin�simplitate�şi�preţ�redus,�manifestă�dinplin�deficienţe�ca:�nivel�ridicat�de�distorsiunearmonică� a� curentului� absorbit� şi� unidi-

recţionalitatea�circulaţiei�puterii.Pentru�depăşirea�acestor�deficienţe� se�uti-lizează�astăzi�filtre�de�reţea�care,�la�puterimari,� devin� prohibitiv� de� voluminoase� şicostisitoare,�iar�pentru�disiparea�energiei�defrânare�se�utilizează�rezistenţe�speciale.O�soluţie�modernă��de�eliminare�a�dezavan-tajelor� prezentate� o� constituie� convertorulMID�c.a.�-�c.c.�care�înlocuieşte�diodele�re-dresoare�cu�tranzistoare�rapide�de�comutaţie(POWER� MOSFET,� IGBT� –� Insulated� –Gate�Bipolar�Transistor)�şi�diode�antiparalelede�recuperare.�Practic,�topologia�acestui�con-vertor�este�identică�cu�cea�a�convertoarelorc.c.-c.a.� MID,� cunoscute� şi� ca� invertoare

MID,�diferenţa�majoră�constând�în�strategiade�comandă.�Se�creează�astfel�premisele�con-vertorului�dublu�MID�c.a.�-�c.c.�-�c.a..�Uti-lizarea� acestuia� în� acţionările� electricereglabile�de�c.a.�(de�exemplu�:�tracţiune�elec-trică)�conduce�la�recuperarea�în�reţea�a�en-ergiei� dezvoltată� în� timpul� frânărilor,simultan�cu�funcţionarea�la�un�factor�de�put-ere�unitar.

Model 1În�cadrul�acestui�model�s-a�considerat�ca�re-dresorul�MID�este�alimentat�la�o�reţea�trifazată�de�tensiuni�alternative�şi�simetrice(ua,�ub,�uc�)�figura.3.16.�Elementele�R�şi�L

ElEctrotEhnica

Stadiul actual in constructia si controlul filtrelor active - Redresoare, invertoare, filtre active(continuare)

drd ing. Gelu Gurguiatu

Page 8: InfoElectrica 19

8InfoElectrica nr. 19 - MAI 2010

reprezintă�parametrii�reţelei�şi�toate�induc-tivităţile�înseriate�pe��fiecare�fază.�În�paralelcu�sarcina�

convertorului�(Rs)�se�află�un�condensator�C.Legătura�dintre�curenţii�la�intrare�şi�curentulla�ieşire�se�poate�scrie�astfel:

Analizând�topologia�redresorului�se�obţine:

(3.5)

Prin�sumarea�celor�trei�ecuaţii�rezultă:

(3.6)Se�notează�căderile�de�tensiune�la�bornele�el-ementelor�L-R�pentru�cele�trei�faze�cu�

(3.7)

(3.8)

Utilizând�ecuaţia�de�sarcină�şi�aplicând�trans-formata� Laplace� se� obţine� diagrama� blocprezentată�în�figura�3.17.�Aceasta�conţine�3axe�de�modelare,�câte�una�pentru�fiecare�fază.

Model 2Modelul�prezentat�figura�3.17poate�fi�simpli-ficat�dacă�se�consideră�ca�mărimi�externe�2tensiunii�de�linie�(u1 şi�u2 ).�Acestea�provinde�la�o�reţea�trifazată�de�tensiuni.�Se�introducdoua�notaţii�noi�m1,�m2 ,�denumite�funcţiigeneratoare�de�comutaţii,�ca�fiind�diferenţa

dintre�doua�câte�doua�funcţii�de�comutaţie�înraport�cu�faza�c�considerate�ca�referinţă�decalcul:

Tensiunile�(um1 si um2)�reprezintă�de�fapttensiunile�(u1 si u2)��modulate.�Se�scrie�teo-rema�Kirchhoff� II�pe�partea�de�alimentareîntre�fazele�(a,�c)�si�(b,�c):

(3.10)

Dacă� se� înlocuieşte� în� expresiile� � (3.10)curentul��ic= - ia - ib,�se�obţine:

(3.11)

Utilizând�noile�notaţii��(m1, m2),�curentul�dela�ieşirea�redresorului�MID�ii se�poate�scrieastfel:

(3.12)

De� asemenea,� tensiunile� modulate� (um1,

um2)�de�la�intrarea�redresorului�se�pot�scrieîn�funcţie�de�(m1, m2)�şi�tensiunea�continuade�la�ieşire�(ud):

(3.13)

Pentru�calculul�tensiunii�continue�la�bornelecondensatorului�(Ud )�se�calculează�mai�întâicurentul�prin�condensatorul�C�şi�se�ţine�contde�corelaţia�curent/tensiune:

(3.14)

În�figura�3.19�s-a�prezentat�diagrama�bloc�aredresorului� trifazat�MID� pe� două� axe� demodelare.�Această�simplificare�de�model�sepoate�aplica�şi�invertoarelor�şi�a�stat�la�bazadefinirii� unui� nou� formalism� de� comandăcare� utilizează� tensiunile� de� linie� pentruobţinerea�duratelor�ciclice�de�comandă.

2. Invertoare:Invertoarele�sunt�convertoare�statice�de�put-ere�c.c.-c.a.�Ele�transformă�o�sursa�de�tensi-une� (sau� curent)� continuu� într-o� sursă� detensiune�(sau�curent)�alternativă,�de�amplitu-dine�sau/şi�frecvenţa�variabilă.�Ele�sunt�uti-lizate� ca� surse� de� tensiune� alternativă� desiguranţă�sau�pentru�alimentarea�şi�reglajulvitezei�maşinilor�electrice.În�această�secţiune�se�prezintă�modelul�matematic�şi�diagramabloc�de�simulare�pentru�invertorul�monofazatde�tensiune�în�punte�prezentat�în�figura.3.20.Utilizând� funcţiile� de� comutaţie� în� douănivele,�se�poate�obţine�tensiunea�la�ieşirea�in-vertorului� în� funcţie� de� tensiunea� de� ali-mentare:

Figura 3. 16 Schema de principiu a redresorului MID

(3.4.)

Figura 3. 17. Diagrama bloc

Figura 3. 18 Schema electrica simplificata a redresorului trifazat MID.

(3.9)

Page 9: InfoElectrica 19

9InfoElectrica nr. 19 - MAI 2010

Curentul�de�la�intrare�se�determină�înfuncţie�de�curentul�de�la�ieşire:

Luând�în�considerare�(3.15)�(3.16)�şi�con-strângerile�topologice�(legea�Kirchhoff)�aleschemei� se� obţine� tensiunea� la� bornelesarcinii�şi�curentul�de�intrare:

Prin�introducerea�unui�filtru�la�intrarea�inver-torului�rezultă�următoarele�expresii:

(3.18)

În�fine,�pentru�sarcină�se�obţine�următoarea�ecuaţie:���

(3.19)

Utilizând� transformata� Laplace� pentruecuaţia�de�mai�sus�se�obţine�diagrama�blocdin�figura�3.21.

Figura 3. 19 Diagrama bloc a redresorului trifazat de tensiune MID pe 2 axe

Figura 3. 20 Invertor monofazat de tensiune

Figura 3. 21. Diagrama bloc a invertorului monofazat de tensiune

Va urma

(3.15)

(3.16)

(3.17)

Reglarea tensiunii în instalaţiile de utilizare prin montarea în seriea condensatoarelor.

Ing. Sorin MORANCEA

1. Generalităţi

Într-un�punct�al�instalaţiei�de�utilizare,�tensi-unea�efectivă�prezintă,�de�la�un�moment�laaltul,�variaţii�cauzate�de:�-�variaţiile�tensiunii�la�bornele�generatoarelor,-�modificarea�tensiunii�la�bornele�secundareale�unor�transformatoare-�variaţia�puterilor�electrice�active�sau�reac-tive.

Într-un� anumit� interval� tensiunea� poateatinge�valoarea�minimă�sau�maximă.�Între�aceste� două� valori� se� defineşte� � tensiuneamedie�efectivă�ca�fiind�media�ponderată�atensiunilor�în�intervalul�de�timp�considerat.

unde:���T�������este�intervalul�de�timp,�în�secunde,�[s]

U������este�tensiunea�măsurată�în�intervalul�t,în�volţi,�[V]

Diferenţa�dintre�tensiunea�medie�şi�tensiuneanominală�se�numeşte�abaterea�medie�a�tensi-unii.

În�afară�de�variaţia�în�timp�a�tensiunii�într-un�punct�oarecare,�se�poate�pune�în�evidenţăo�modificare�a�tensiunii�în�lungul�circuituluideterminată�de�impendanţa�acestuia.�Practicpierderea�de�tensiune�reprezintă�diferenţa�al-gebrică�dintre� tensiunile� la� începutul� şi� lacapătul�circuitului.

U�=�U0 –�U�=�IR�cos +�IX�sin =�I(r�cos+�x�sin)�l,

unde:��U,�U0,�U,�sunt�tensiunile�pe�o�fază�a�cir-cuituluil��������este�lungimea�circuitului,R,�X�sunt�rezistenţa,�respectiv�reactanţa�pefazăr,�x��sunt�rezistenţa,�respectiv�reactanţa�pefază,�pe�unitatea�de�lungime este�unghiul�de�defazaj

Din�relaţia�de�mai�sus�se�pot�deduce�uneleprocedee� pentru� modificarea� tensiunii.� Încelel�ce�urmează�vă�propunem�o�metodă�devariaţie�a�tensiunii�prin�montarea�în�serie�aunor�capacitoare.

2. montarea în serie a condensatoarelor

Majoritatea�consumatorilor�industrial�au�uncaracter� inductiv.�Din�acest�motiv�consid-erăm�circuitul�inductiv�din�fig.�1�care,�din

[V]

Page 10: InfoElectrica 19

10InfoElectrica nr. 19 - MAI 2010

punct�de�vedere�electric,�poate�fi�echivalat�cuun�circuit�având�în�conectate�în�serie�o�rezis-tenţă�şi�o�inductanţă.�

În�acest�caz�curentul�din�circuit,�I,�va�pro-duce�o�cădere�de�tensiune�pe�elementul�derezistenţă�R��şi�o�cădere�de�tensiune�pe�in-ductivitatea�L.�Astfel�rezultă�o�cădere�de�ten-siune�U0 care�pentru�o�tensiune�U�necesarăla�capătul�circuitului,�impune�o�tensiune�in-iţiala�U0.

Dacă�în�circuitul�considerat�se�introduce,�înserie,�o�capacitate�C,�având�reactanţa�capac-itivă�XC,�reactanţa�totală�a�circuitului�se�re-duce�la�o�valoare�

XT =�XL –�XC

În� această� situaţie� căderea� de� tensiune� perezistenţă�rămâne�neschimbată�şi�egală�cu�IR,în�schimb�căderea�de�tensiune�pe�reactanţainductivă�se�va�reduce�de�la�IXL la�valoareaIXT =�I(XL –�XC),�rezultând�în�acest�caz�opierdere�de� tensiune�UR mai�mică�decâtU0.�Deci�tensiunea�U�necesară�la�capătulcircuitului,�poate�fi�asigurată�de�o�tensiuneUR mai�mică�decât�U0.�deasemenea�defaza-jul�la�capătul�circuitului�scade�de�la�0 la�R.

Se�observă�că�la�egalitatea�reactaţei�inductiveşi�a�reactaţei�capacitive�pierderea�de�tensiuneva�fi�dată�numai�de�către�căderea�de�tensiunepe�rezistenţa�circuitului.�Mărind�în�cpntin-uare� reactaţa� capacitivă,� se� ajunge� la� opierdere�de�tensiune�negativă,�adică�tensi-unea�la�capătul�circuitului�poate�fi�mai�maredecât�la�începutul�lui.

Metoda�se�poate�folosi�cu�succes�în�cazul�cir-cuitelor�cu�variaţii�bruşte�de�putere,�în�cazulcircuitelor�cu�secţiune�mare�a�conductoarelorcât�şi�la�instalaţiile�cu�factor�de�putere�scăzut(cos =�0,7�–�0,8)

3. Calculul capacităţii condensatoarelor

Tensiunea�suplimentară�de�reglaj�pe�o�fază:

Us�=�U0 –�UR =�IX�sin

Reactanţa�capacitivă�a�condensatoarelor�caretrebuie�montate�în�serie�în�circuit:

Capacitatea�condensatorului�

Puterea�reactivă�totală�a�bateriei�de�conden-satoare:

4. Concluzii

Reglajul� tensiunii� în� instalaţiile� electriceconduce� la� economii� de� energie� electricănumai�atunci�când�la�ridicarea�tensiunii�apor-tul� de� energie� rezultat� acoperă� costul�mi-jloacelor�folosite.

W�–�Wrg >Wd

Unde:��W������sunt�pierderile�de�energie�înainte�dereglaj,�[kWh/an]Wrg idem,�după�reglaj�[kWh/an]Wd consumul�de�energie�al�dispozitivuluiprin�care�se�realizează�reglajul�[kWh/an]

5. Reguli şi norme statutare

Definirea�treptelor�de�tensiune.Conform� standardelor� CEI� 60038� sinormelor� interne� I7/2002,� tensiunile�nomi,tensiunile�nominale�standardizateşi�recoman-date�sunt:�

Notă:�Tensiunea�maximă�şi�minimă�nu�vadiferi�cu�mai�mult�de� 10%�faţă�de�tensiuneanominală.

Tensiunea�nominală�a�unui�sistem�sau�a�unuiechipament� este� definită� de� CE� 60038� ca„tensiunea�la�care�un�sistem�sau�echipamenteste�proiectat��şi�pentru�care�sunt�definite�car-acteristicile�funcţionale�sigure”

Tensiunea�cea�mai�ridicată�pentru�un�echipa-ment�este�definită�de� �CE�60038�ca:�„val-oarea� maximă� a� tensiunii� la� careechipamentul�poate�fi�utilizat�,�care�apare�încondiţii��normale�de�funcţionare�,�oricând�şiîn�orice�punct�al�sistemului.�Ea�exclude�ten-siuni�tranzitorii,�cum�ar�fi�cele�datorate�pro-ceselor�de�comutaţie�şi�variaţiile�temporarede�tensiune.”�

6. Măsurători în staţia de o,4kV

Măsurătorile� s-au� efectuat� într-o� staţie� de0.4kV�aflată�în�exploatare.�Deoarece�la�dataefectuării� măsurătorilor� consumurile� eraurelativ�mici�şi�căderea�de�tensiune�a�fost�maimică.�În�mod�normal�beneficiarul�reclamascaderea�tensiunii�sub�valoarea�normată�şi�decele�mai�multe�ori�intrau�în�funcţiune�UPS-urile� sau� grupul� electrogen.�Acest� lucru� aimpus�realizarea�unui�sistem�pentru�modifi-care�tensiunii�prin�înserierea�unor�baterii�decondensatoare.

În�staţia�de�0,4kV�s-au�efectuat�măsurători�înTabloul�electric�de�distribuţie,�în�următoarelesituaţii:

-�Bateriile�de�compensare�decuplate

U

I L R

Fig. 1. Schema de principiu a unui circuit in-

ductiv

UI C

L R

Fig. 2. Schema de principiu a unui circuit in-

ductiv cu condensatoare montate în serie

[F]

[kVAR]

Sistem trifazat cu patru sau trei conduc-toare.

Sistem monofazat cu trei conduc-toare.

Tensiunea nominală (V) Tensiunea nominală (V)

50Hz 60Hz 60Hz

- 120/208 120/240

- 240

230/400 277/480

400/690 480

- 347/600

1000 600

Tensiuni standardizate cuprinse între 100 şi 1000V (CE 60038, Ediţia 6,2 2002-07)

Page 11: InfoElectrica 19

11InfoElectrica nr. 19 - MAI 2010

Număr�de�măsurători:�305măsurători

URMS Medie� :� L1 =� 415,14V;� � L2 =416,53V;��L3 =��419,05�V

VRMS Medie� :� L1 =� 239,68V;� � L2 =

240,48V;��L3 =�241,93V

cosmed =�0,65

Uthdmed =�0,61

Athdmed =�3,52

Constatări:

Tensiunile�de�linie�şi�tensiunile�de�fază�se�în-

scriu�în�limitele�de�+10%,�valori�recoman-

date�de�CE�60038.

Factorul�de�putere�este�de�0,65

Coeficientul�de�distorsiune�datorate�armoni-

cilor�Athdmed�<�5%,�regim�nedeformant.

Page 12: InfoElectrica 19

12InfoElectrica nr. 19 - MAI 2010

-��Bateriile�de�compensare�cuplate

Număr�de�măsurători:�301măsurătoriURMS� Medie� :� L1� =� 427,04V;� � L2� =428,31V;��L3�=��430,84�VVRMS� Medie� :� L1� =� 247,84V;� � L2� =246,24V;��L3�=�248,45Vcosmed =�0,96Uthdmed =�0,64Athdmed�=�7,81Constatări:

Tensiunile�de�linie�şi�tensiunile�de�fază�se�în-scriu�în�limitele�de�+10%,�valori�recoman-date�de�CE�60038.Factorul�de�putere�este�de�0,96Coeficientul�de�distorsiune�datorate�armoni-cilor�Athdmed�aproape�de�5%.�Comparand�cele�doua�seturi�de�masuratori�setrag�urmatoarele�concluzii:-�Valorile�efective�ale�tensiunilor�de�linie�si

de�faza�sunt�sub�abaterea�de�+10%

-�Se�constata�ca�dupa�conectarea�bateriilor�de

condesatoare� tensiunile� cresc� cu� aprox.

2,86%�

-�Graficul�variatiei�in�timp�a�valorilor�tensi-

unilor�este�mai�aplatizat�in�cazul�instalatiilor

de�compensare�pornite.

Page 13: InfoElectrica 19

13InfoElectrica nr. 19 - MAI 2010

Continuam�cu�traditionalul�test�de�automati-zari�ajuns�la�editia�a�8-a�propunandu-va�cade�obicei�in�finalul�revistei,�ca�relaxare,�sarezolvati�o��problema�de�automatizari�,la�careveti�primi�raspunsul�corect�in�numarul�urma-tor�al�revistei.�Cei�care�vor�sa�participe� laacest�test,�pot�scrie�raspunsul�lor�la�[email protected]��.�Cei�care�au�datraspunsul�corect�vor�fi�citati�in�numarul�viitor.

Succes�!

Testul�din�acest�numar�este�pus�la�dispozitieprin�amabilitatea�domnului�Turcu�Gheorghe.Iata�enuntul�:Sa� se� completeze� schema� astfel� incat� lainchiderea�contactului�K,�cele�5�contactoaresa�fie�actionate�pe�rand,�in�cascada,�in�or-dinea�C1,�C2,�C3,�C4,�C5�la�un�anumit�inter-

val�de�timp�intre�ele,�actionarea�fiind�tempo-rizata�de�releul�de�timp�d.Releul�de�timp�functioneaza�in�regim�de�asta-bil,�adica�atata�timp�cat�este�alimentat�bas-culeaza�continuu�contactele�dintr-o�stare�inalta.Schema�este�utila�la�pornirea�secventiala�amotoarelor�ventilatoarelor�unui�uscator�decherestea,�astfel�evitandu-se�varful�de�sarcina.

tEst dE pErspicacitatE in aUtomatizari

Rebusul nr 8

La� testul� din� numarul� trecut� au� raspunscorect� si-i� felicitam� pe� :� Cristian� Corban,Marcel�Tudor,�Avasalcai�Pavel,�Tiniuc�Ghe-orghe,�Mihai�Moise,�Valean�Lucian�Cornel,Morosanu�Stefan�Mihai,�Sin�Mihail,�SorinLupei,�Raul�Dobritoiu,�Erzsebet�Szabo,�Mi-coroi�Ioan,�Selko�Alexandru,�Victoria�Zam-canu,� Lucaci� Viorel� Marian,� NecseszanFerenc,� Balogh� Tiberiu,�Mihai�Alexandru,Rusu�Constantin,�Vasile�Cucu-Nitan,�NicolaeIonescu,�Cojan�Cornel�si��Andrei�Gardea.�Dupa�cum�se�vede�succesul�acestui�test�a�de-

venit�impresionant�de�mare,�ca�o�dovada�ev-identa�ca�avem�foarte�multi�automatisti�decalitate�,�pasionati�de�aceasta�meserie.�Astanu�poate�decat�sa�ne�incante�si�sa�ne�incite�sagasim� teste� tot� mai� interesante.� De� altfelmulti�dintre�participanti�la�acest�concurs�auinceput�sa�trimita�propriile�propuneri,�pe�carele�vom�programa�in�numerele�viitoare.Problema�din�numarul�trecut�a�fost�formulataastfel�:Sa�se�completeze�schema�de�mai�jos�cu�ori-cate�contacte�auxiliare,�astfel�incat:

-�la�apasarea�butonului�B1�sa�porneasca�mo-torul�M2;-�la�revenirea�butonului�B1�sa�porneasca�mo-torul�M1�si�M2�sa�ramana�in�functiune;-� la� o� noua� apasare� a� butonului� B1� saporneasca�M3,�sa�se�opreasca�M2�si�M1�saramana�in�functiune�(la�oricare�apasare�ulte-rioara�a�butonului�B1,�schema�va�ramane�inaceasta�ultima�stare)-�la�apasarea�butonului�B2�se�opresc�toatemotoarele�(schema�revine�in�starea�initiala)�