U.P.T. FACULTATEA DE CONSTRUCTII PROIECT DE DIPLOMA CALCULUL TERMO-HIGRO-ENERGETIC 1. DATE DE INTRARE CONDITII EXTERIOARE e 80 % em -15 C Re 0.043 CONDITII INTERIOARE i 60 % i 20 C Ri 0.123 ALCATUIRE ELEMENT (de la interior la exterior) Nr. Crt Denumire strat d [m] 1 Mortar var ciment 0.01 2 Caramida plina 0.25 3 Polistiren 0.05 4 Mortar var ciment 0.005 5 Nimic 0 6 Nimic 0 7 Nimic 0 8 Nimic 0 9 Nimic 0 10 Nimic 0 Temperatura aparitie condens es = -19 2. REZULTATE A. Verificare transfer termic R o = 1,75 [m 2 K/W] COORDONATOR: dr. ing. Ion BOGDAN 117 STUDENT: Adrian CENTEA

Upload: mihai-jurj

Post on 17-Sep-2015

227 views

Category:

Documents


0 download

DESCRIPTION

calculul termic al cladirii

TRANSCRIPT

CALCULUL PLACI LA COTA +9,12

U.P.T.FACULTATEA DE CONSTRUCTII

PROIECT DE DIPLOMA

CALCULUL TERMO-HIGRO-ENERGETIC

1. DATE DE INTRARE

CONDITII EXTERIOARE

e80%

em-15C

Re0.043

CONDITII INTERIOARE

i60%

i20C

Ri0.123

ALCATUIRE ELEMENT (de la interior la exterior)

Nr. CrtDenumire stratd [m]

1Mortar var ciment0.01

2Caramida plina0.25

3Polistiren0.05

4Mortar var ciment0.005

5Nimic0

6Nimic0

7Nimic0

8Nimic0

9Nimic0

10Nimic0

Temperatura aparitie condens

es=-19

2. REZULTATE

A.Verificare transfer termic

Ro=1,75 [m2K/W]

B.Verificarea aparitiei condensului pe suprafata interioara

NU APARE CONDENS PE SUPRAFATA INTERIOARA

C.Verificarea aparitiei condensului

Vezi grafice Pcorectat-Rv

D.Determinarea temp ext la care apare condensul

Se introduc valori pentru temp exterioara pana Pv tangent la Ps

E.Determinarea temperaturii exterioare medie de condens

es=-20

F.Determinarea duratei de timp Nw in care se produce condens

Nw=75

F.Presiunile vaporilor pt calculul masei de apa

pvi=1404Pa

pve=132Pa

In ANEXELE 1,2,3 atasate acestui capitol, sunt prezentate graficele de presiunilor vaporilor de apa din interiorul peretilor.

COORDONATOR: dr. ing. Ion BOGDAN 117 STUDENT: Adrian CENTEA